Luke Lamers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Luke Lamers has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
Alejandro Roldán-Alzate
2 shared publicationsAlexandra Erdmann
Division of Cardiology, Department of Pediatrics, University of Wisconsin-Madison, Madison, USA
2 shared publicationsChristopher J. Francois
School of Medicine and Public Health University of Wisconsin–Madison Madison Wisconsin USA
2 shared publicationsJenna Torgeson
Division of Cardiology, Department of Pediatrics, University of Wisconsin-Madison, Madison, USA
2 shared publicationsPetros V. Anagnostopoulos
Department of Cardiothoracic Surgery, University of Wisconsin School of Medicine and Public Health Madison, Wisconsin, 53792
2 shared publications- Ryan Pewowaruk
William S. Middleton Memorial Veterans Hospital
2 shared publications
Latest Publications
- Open Access
Structural and Mechanical Analysis of Treated and Untreated Aortic Coarctation in a Growing Porcine Model
Coarctation of the aorta (COA) is a congenital heart disease for which successful intervention can restore flow and reduce the blood pressure gradient, but does not ensure long-term health. Adults with successfully treated COA exhibit significantly higher incidence of hypertension. The objective of this study was to measure differences in the structure and mechanics of proximal and distal aortic tissue from a new, physiologically relevant growing porcine model of COA. This animal model also enabled the evaluation of a cutting-edge serially dilatable stent. Quantitative histologic analysis measured structural changes and the mechanical properties were investigated through uniaxial, shear lap, and peel tests of tissue from sham, control COA, and treated COA animals. Our original hypothesis that proximal aortic tissue from control and treated COA groups would be thicker and have less elastin was false. There were no significant differences in elastin content, collagen content, tissue area, lumen area, or lumen-to-tissue area between groups. Mechanically, distal tissue also exhibited no difference in either uniaxial or shear lap stiffness, failure stress, or failure strain between groups. Distal tissue from the COA control and treated COA groups however, exhibited, a lower circumferential failure peel tension, suggesting interlamellar strength was reduced. When compared with other previously published animal models of COA, a clear distinction was timing - our growing porcine model is the first for which COA was induced and treated at physiologically relevant time points. Our results indicated minimal adverse vascular remodeling in either the COA control or treated COA groups, however, it is unclear if this was due to a lack of severity, if elastinogenesis compensated for damage, or if another unknown mechanism prevented remodeling.
Open AccessStructural and Mechanical Analysis of Treated and Untreated Aortic Coarctation in a Growing Porcine Model
Coarctation of the aorta (COA) is a congenital heart disease for which successful intervention can restore flow and reduce the blood pressure gradient, but does not ensure long-term health. Adults with successfully treated COA exhibit significantly higher incidence of hypertension. The objective of this study was to measure differences in the structure and mechanics of proximal and distal aortic tissue from a new, physiologically relevant growing porcine model of COA. This animal model also enabled the evaluation of a cutting-edge serially dilatable stent. Quantitative histologic analysis measured structural changes and the mechanical properties were investigated through uniaxial, shear lap, and peel tests of tissue from sham, control COA, and treated COA animals. Our original hypothesis that proximal aortic tissue from control and treated COA groups would be thicker and have less elastin was false. There were no significant differences in elastin content, collagen content, tissue area, lumen area, or lumen-to-tissue area between groups. Mechanically, distal tissue also exhibited no difference in either uniaxial or shear lap stiffness, failure stress, or failure strain between groups. Distal tissue from the COA control and treated COA groups however, exhibited, a lower circumferential failure peel tension, suggesting interlamellar strength was reduced. When compared with other previously published animal models of COA, a clear distinction was timing - our growing porcine model is the first for which COA was induced and treated at physiologically relevant time points. Our results indicated minimal adverse vascular remodeling in either the COA control or treated COA groups, however, it is unclear if this was due to a lack of severity, if elastinogenesis compensated for damage, or if another unknown mechanism prevented remodeling.
- Open Access
- 18 September 2024
- Published by Elsevier in JACC: Case Reports
- Vol. 29 (18) , 102556
Polyvalvular Dysplasia and Vascular Abnormalities in a Neonate With an FLNA Variant
- 18 September 2024
- Published by Elsevier in JACC: Case Reports
- Vol. 29 (18) , 102556
Open AccessPolyvalvular Dysplasia and Vascular Abnormalities in a Neonate With an FLNA Variant
- 25 June 2024
- Published by Springer Nature in Pediatric Cardiology
- Vol. 46 (5) , 1320-1327
Reducing Adverse Events Associated with Pediatric Cardiac Catheterization: A Quality Improvement Project Focusing on Decreasing Catheterization-Associated Blood Transfusions
The objective of this study is to describe interventions and outcomes of a quality improvement (QI) project to reduce red blood cell transfusion (RBCT) within 72 h of pediatric cardiac catheterization. Using Plan-Do-Study-Act (PDSA) methodology, we applied interventions including (1). Intraprocedural—to reduce hemodilution, blood loss, and excessive anticoagulation, (2). Standardization of institutional transfusion criteria, and (3). “Hard stop” requiring QI team consultation prior to elective post-catheterization RBCT. Primary outcome measures were frequency of RBCT from IMPACT quarterly reports and cases between transfusions (CBT). Length of stay (LOS) was the primary countermeasure. Characteristics of patients who did and did not receive RBCT were compared. 698 pediatric cardiac catheterizations occurred between 4/2017 and 8/2023. Intraprocedural interventions did not alter frequency of RBCT or CBT. Standardized transfusion guidelines followed by the “hard stop” decreased RBCT frequency from 10 to 1.9% and increased CBT without increasing LOS. Patients requiring RBCT were younger (medians 0.31 vs 2.4 years), smaller (5.2 vs 11.8 kg), and had longer procedures (2.24 vs 1.57 h) all p < 0.001. Single ventricle patients were more likely to have RBCT than simple biventricular patients (14.1% vs 3.1%; RR = 4.57, 95% CI 2.29–10.4; p < 0.001). Procedure type (diagnostic vs. intervention) and starting hemoglobin concentration were comparable between groups. Programmatic adherence to standardized peri-procedural transfusion guidelines successfully decreased RBCT without compromising patient care or increasing LOS. Younger age, lower weight, procedure length, and single ventricle physiology were all associated with RBCT risk.
- 25 June 2024
- Published by Springer Nature in Pediatric Cardiology
- Vol. 46 (5) , 1320-1327
Reducing Adverse Events Associated with Pediatric Cardiac Catheterization: A Quality Improvement Project Focusing on Decreasing Catheterization-Associated Blood Transfusions
The objective of this study is to describe interventions and outcomes of a quality improvement (QI) project to reduce red blood cell transfusion (RBCT) within 72 h of pediatric cardiac catheterization. Using Plan-Do-Study-Act (PDSA) methodology, we applied interventions including (1). Intraprocedural—to reduce hemodilution, blood loss, and excessive anticoagulation, (2). Standardization of institutional transfusion criteria, and (3). “Hard stop” requiring QI team consultation prior to elective post-catheterization RBCT. Primary outcome measures were frequency of RBCT from IMPACT quarterly reports and cases between transfusions (CBT). Length of stay (LOS) was the primary countermeasure. Characteristics of patients who did and did not receive RBCT were compared. 698 pediatric cardiac catheterizations occurred between 4/2017 and 8/2023. Intraprocedural interventions did not alter frequency of RBCT or CBT. Standardized transfusion guidelines followed by the “hard stop” decreased RBCT frequency from 10 to 1.9% and increased CBT without increasing LOS. Patients requiring RBCT were younger (medians 0.31 vs 2.4 years), smaller (5.2 vs 11.8 kg), and had longer procedures (2.24 vs 1.57 h) all p < 0.001. Single ventricle patients were more likely to have RBCT than simple biventricular patients (14.1% vs 3.1%; RR = 4.57, 95% CI 2.29–10.4; p < 0.001). Procedure type (diagnostic vs. intervention) and starting hemoglobin concentration were comparable between groups. Programmatic adherence to standardized peri-procedural transfusion guidelines successfully decreased RBCT without compromising patient care or increasing LOS. Younger age, lower weight, procedure length, and single ventricle physiology were all associated with RBCT risk.
- 16 October 2020
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 96 (7) , 1454-1464
Pulmonary artery and lung parenchymal growth following early versus delayed stent interventions in a swine pulmonary artery stenosis model
Objectives: Compare lung parenchymal and pulmonary artery (PA) growth and hemodynamics following early and delayed PA stent interventions for treatment of unilateral branch PA stenosis (PAS) in swine.Background: How the pulmonary circulation remodels in response to different durations of hypoperfusion and how much growth and function can be recovered with catheter directed interventions at differing time periods of lung development is not understood.Methods: A total of 18 swine were assigned to four groups: Sham (n = 4), untreated left PAS (LPAS) (n = 4), early intervention (EI) (n = 5), and delayed intervention (DI) (n = 5). EI had left pulmonary artery (LPA) stenting at 5 weeks (6 kg) with redilation at 10 weeks. DI had stenting at 10 weeks. All underwent right heart catheterization, computed tomography, magnetic resonance imaging, and histology at 20 weeks (55 kg).Results: EI decreased the extent of histologic changes in the left lung as DI had marked alveolar septal and bronchovascular abnormalities (p = .05 and p < .05 vs. sham) that were less prevalent in EI. EI also increased left lung volumes and alveolar counts compared to DI. EI and DI equally restored LPA pulsatility, R heart pressures, and distal LPA growth. EI and DI improved, but did not normalize LPA stenosis diameter (LPA/DAo ratio: Sham 1.27 ± 0.11 mm/mm, DI 0.88 ± 0.10 mm/mm, EI 1.01 ± 0.09 mm/mm) and pulmonary blood flow distributions (LPA‐flow%: Sham 52 ± 5%, LPAS 7 ± 2%, DI 44 ± 3%, EI 40 ± 2%).Conclusion: In this surgically created PAS model, EI was associated with improved lung parenchymal development compared to DI. Longer durations of L lung hypoperfusion did not detrimentally affect PA growth and R heart hemodynamics. Functional and anatomical discrepancies persist despite successful stent interventions that warrant additional investigation.
- 16 October 2020
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 96 (7) , 1454-1464
Pulmonary artery and lung parenchymal growth following early versus delayed stent interventions in a swine pulmonary artery stenosis model
Objectives: Compare lung parenchymal and pulmonary artery (PA) growth and hemodynamics following early and delayed PA stent interventions for treatment of unilateral branch PA stenosis (PAS) in swine.Background: How the pulmonary circulation remodels in response to different durations of hypoperfusion and how much growth and function can be recovered with catheter directed interventions at differing time periods of lung development is not understood.Methods: A total of 18 swine were assigned to four groups: Sham (n = 4), untreated left PAS (LPAS) (n = 4), early intervention (EI) (n = 5), and delayed intervention (DI) (n = 5). EI had left pulmonary artery (LPA) stenting at 5 weeks (6 kg) with redilation at 10 weeks. DI had stenting at 10 weeks. All underwent right heart catheterization, computed tomography, magnetic resonance imaging, and histology at 20 weeks (55 kg).Results: EI decreased the extent of histologic changes in the left lung as DI had marked alveolar septal and bronchovascular abnormalities (p = .05 and p < .05 vs. sham) that were less prevalent in EI. EI also increased left lung volumes and alveolar counts compared to DI. EI and DI equally restored LPA pulsatility, R heart pressures, and distal LPA growth. EI and DI improved, but did not normalize LPA stenosis diameter (LPA/DAo ratio: Sham 1.27 ± 0.11 mm/mm, DI 0.88 ± 0.10 mm/mm, EI 1.01 ± 0.09 mm/mm) and pulmonary blood flow distributions (LPA‐flow%: Sham 52 ± 5%, LPAS 7 ± 2%, DI 44 ± 3%, EI 40 ± 2%).Conclusion: In this surgically created PAS model, EI was associated with improved lung parenchymal development compared to DI. Longer durations of L lung hypoperfusion did not detrimentally affect PA growth and R heart hemodynamics. Functional and anatomical discrepancies persist despite successful stent interventions that warrant additional investigation.
- Open Access
- 9 October 2020
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 37 (2) , 743-753
Comparison of pulmonary artery dimensions in swine obtained from catheter angiography, multi-slice computed tomography, 3D-rotational angiography and phase-contrast magnetic resonance angiography
Accurate pulmonary artery (PA) imaging is necessary for management of patients with complex congenital heart disease (CHD). The ability of newer imaging modalities such as 3D rotational angiography (3DRA) or phase-contrast magnetic resonance angiography (PC-MRA) to measure PA diameters has not been compared to established angiography techniques. Measurements of PA diameters (including PA stenosis and PA stents) from 3DRA and non-contrast-enhanced PC-MRA were compared to 2D catheter angiography (CA) and multi-slice computed tomography (MSCT) in a swine CHD model (n = 18). For all PA segments 3DRA had excellent agreement with CA and MSCT (ICC = 0.94[0.91–0.95] and 0.92[0.89–0.94]). 3DRA PA stenosis measures were similar to CA and MSCT and 3DRA was on average within 5% of 10.8 ± 1.3 mm PA stent diameters from CA and MSCT. For compliant PA segments, 3DRA was on average 3–12% less than CA (p < 0.05) and MSCT (p < 0.01) for 6–14 mm vessels. PC-MRA could not reliably visualize stents and distal PA vessels and only identified 34% of all assigned measurement sites. For measured PA segments, PC-MRA had good agreement to CA and MSCT (ICC = 0.87[0.77–0.92] and 0.83[0.72–0.90]) but PC-MRA overestimated stenosis diameters and underestimated compliant PA diameters. Excellent CA-MSCT PA diameter agreement (ICC = 0.95[0.93–0.96]) confirmed previous data in CHD patients. There was little bias in PA measurements between 3DRA, CA and MSCT in stenotic and stented PAs but 3DRA underestimates measurements of compliant PA regions. Accurate PC-MRA imaging was limited to unstented proximal PA anatomy.
- 9 October 2020
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 37 (2) , 743-753
Open AccessComparison of pulmonary artery dimensions in swine obtained from catheter angiography, multi-slice computed tomography, 3D-rotational angiography and phase-contrast magnetic resonance angiography
Accurate pulmonary artery (PA) imaging is necessary for management of patients with complex congenital heart disease (CHD). The ability of newer imaging modalities such as 3D rotational angiography (3DRA) or phase-contrast magnetic resonance angiography (PC-MRA) to measure PA diameters has not been compared to established angiography techniques. Measurements of PA diameters (including PA stenosis and PA stents) from 3DRA and non-contrast-enhanced PC-MRA were compared to 2D catheter angiography (CA) and multi-slice computed tomography (MSCT) in a swine CHD model (n = 18). For all PA segments 3DRA had excellent agreement with CA and MSCT (ICC = 0.94[0.91–0.95] and 0.92[0.89–0.94]). 3DRA PA stenosis measures were similar to CA and MSCT and 3DRA was on average within 5% of 10.8 ± 1.3 mm PA stent diameters from CA and MSCT. For compliant PA segments, 3DRA was on average 3–12% less than CA (p < 0.05) and MSCT (p < 0.01) for 6–14 mm vessels. PC-MRA could not reliably visualize stents and distal PA vessels and only identified 34% of all assigned measurement sites. For measured PA segments, PC-MRA had good agreement to CA and MSCT (ICC = 0.87[0.77–0.92] and 0.83[0.72–0.90]) but PC-MRA overestimated stenosis diameters and underestimated compliant PA diameters. Excellent CA-MSCT PA diameter agreement (ICC = 0.95[0.93–0.96]) confirmed previous data in CHD patients. There was little bias in PA measurements between 3DRA, CA and MSCT in stenotic and stented PAs but 3DRA underestimates measurements of compliant PA regions. Accurate PC-MRA imaging was limited to unstented proximal PA anatomy.
- Open Access
- 31 October 2019
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 2019, 1-7
Multicenter Assessment of Radiation Exposure during Pediatric Cardiac Catheterizations Using a Novel Imaging System
Objectives. To quantify radiation exposure during pediatric cardiac catheterizations performed by multiple operators on a new imaging platform, the Artis Q.zen (Siemens Healthcare, Forchheim, Germany), and to compare these data to contemporary benchmark values. Background. The Artis Q.zen has been shown to achieve significant radiation reduction during select types of pediatric cardiac catheterizations in small single-center studies. No large multicenter study exists quantifying patient dose exposure for a broad spectrum of procedures. Methods. Retrospective collection of Air Kerma (AK) and dose area product (DAP) for all pediatric cardiac catheterizations performed on this new imaging platform at four institutions over a two-year time period. Results. A total of 1,127 pediatric cardiac catheterizations were analyzed. Compared to dose data from earlier generation Artis Zee imaging systems, this study demonstrates 70–80% dose reduction (AK and DAP) for similar patient and procedure types. Compared to contemporary benchmark data for common interventional procedures, this study demonstrates an average percent reduction in AK and DAP from the lowest dose saving per intervention of 39% for AK and 27% for DAP for transcatheter pulmonary valve implantation up to 77% reduction in AK and 70% reduction in DAP for atrial septal defect closure. Conclusion. Use of next-generation imaging platforms for pediatric cardiac catheterizations can substantially decrease patient radiation exposure. This multicenter study defines new low-dose radiation measures achievable on a novel imaging system.
- 31 October 2019
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 2019, 1-7
Open AccessMulticenter Assessment of Radiation Exposure during Pediatric Cardiac Catheterizations Using a Novel Imaging System
Objectives. To quantify radiation exposure during pediatric cardiac catheterizations performed by multiple operators on a new imaging platform, the Artis Q.zen (Siemens Healthcare, Forchheim, Germany), and to compare these data to contemporary benchmark values. Background. The Artis Q.zen has been shown to achieve significant radiation reduction during select types of pediatric cardiac catheterizations in small single-center studies. No large multicenter study exists quantifying patient dose exposure for a broad spectrum of procedures. Methods. Retrospective collection of Air Kerma (AK) and dose area product (DAP) for all pediatric cardiac catheterizations performed on this new imaging platform at four institutions over a two-year time period. Results. A total of 1,127 pediatric cardiac catheterizations were analyzed. Compared to dose data from earlier generation Artis Zee imaging systems, this study demonstrates 70–80% dose reduction (AK and DAP) for similar patient and procedure types. Compared to contemporary benchmark data for common interventional procedures, this study demonstrates an average percent reduction in AK and DAP from the lowest dose saving per intervention of 39% for AK and 27% for DAP for transcatheter pulmonary valve implantation up to 77% reduction in AK and 70% reduction in DAP for atrial septal defect closure. Conclusion. Use of next-generation imaging platforms for pediatric cardiac catheterizations can substantially decrease patient radiation exposure. This multicenter study defines new low-dose radiation measures achievable on a novel imaging system.
- Open Access
- 17 April 2018
- Published by Springer Nature in Journal of Congenital Cardiology
- Vol. 2 (1) , 2
Case report description of a collaborative approach to thoracic duct embolization in patients with congenital heart disease
- 17 April 2018
- Published by Springer Nature in Journal of Congenital Cardiology
- Vol. 2 (1) , 2
Open AccessCase report description of a collaborative approach to thoracic duct embolization in patients with congenital heart disease
- 30 March 2018
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 92 (1) , 78-87
Consequences of an early catheter‐based intervention on pulmonary artery growth and right ventricular myocardial function in a pig model of pulmonary artery stenosis
Objective: To determine the consequences of an early catheter‐based intervention on pulmonary artery (PA) growth and right ventricular (RV) myocardial function in an animal model of branch PA stenosis.Background: Acute results and safety profiles of deliberate stent fracture within the pulmonary vasculature have been demonstrated. The long‐term impact of early stent intervention and deliberate stent fracture on PA growth and myocardial function is not understood.Methods: Implantation of small diameter stents was performed in a pig model of left PA stenosis at 6 weeks (10 kg) followed by dilations at 10 (35 kg) and 18 weeks (65 kg) with intent to fracture and implant large diameter stents. Hemodynamics, RV contractility, and 2D/3D angiography were performed with each intervention. The heart and pulmonary vasculature were histologically assessed.Results: Stent fracture occurred in 9/12 and implantation of large diameter stents was successful in 10/12 animals with no PA aneurysms or dissections. The final stented PA segment and distal left PA branch origins equaled the corresponding PA diameters of sham controls. Growth of left PA immediately beyond the stent was limited and there was diffuse fibro‐intimal proliferation within the distal left and right PA. RV contractility was diminished in the intervention group and the response to dobutamine occurred uniquely via increases in heart rate.Conclusions: Early stent intervention in this surgically created PA stenosis model was associated with improved growth of the distal PA vasculature but additional investigation of PA vessel physiology and impact on the developing heart are needed.
- 30 March 2018
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 92 (1) , 78-87
Consequences of an early catheter‐based intervention on pulmonary artery growth and right ventricular myocardial function in a pig model of pulmonary artery stenosis
Objective: To determine the consequences of an early catheter‐based intervention on pulmonary artery (PA) growth and right ventricular (RV) myocardial function in an animal model of branch PA stenosis.Background: Acute results and safety profiles of deliberate stent fracture within the pulmonary vasculature have been demonstrated. The long‐term impact of early stent intervention and deliberate stent fracture on PA growth and myocardial function is not understood.Methods: Implantation of small diameter stents was performed in a pig model of left PA stenosis at 6 weeks (10 kg) followed by dilations at 10 (35 kg) and 18 weeks (65 kg) with intent to fracture and implant large diameter stents. Hemodynamics, RV contractility, and 2D/3D angiography were performed with each intervention. The heart and pulmonary vasculature were histologically assessed.Results: Stent fracture occurred in 9/12 and implantation of large diameter stents was successful in 10/12 animals with no PA aneurysms or dissections. The final stented PA segment and distal left PA branch origins equaled the corresponding PA diameters of sham controls. Growth of left PA immediately beyond the stent was limited and there was diffuse fibro‐intimal proliferation within the distal left and right PA. RV contractility was diminished in the intervention group and the response to dobutamine occurred uniquely via increases in heart rate.Conclusions: Early stent intervention in this surgically created PA stenosis model was associated with improved growth of the distal PA vasculature but additional investigation of PA vessel physiology and impact on the developing heart are needed.
- 10 March 2018
- Published by Springer Nature in Pediatric Cardiology
- Vol. 39 (5) , 884-891
Intraoperative Completion Angiogram May Be Superior to Transesophageal Echocardiogram for Detection of Pulmonary Artery Residual Lesions in Congenital Heart Surgery
The purpose of this study was to assess the diagnostic capabilities of transesophageal echocardiography (TEE) compared to completion angiography for detection of residual post-operative pulmonary artery lesions. This is a retrospective review of 19 consecutive surgical cases involving the pulmonary arteries that had post-operative TEE and completion angiography from 2014 to 2017. The echocardiograms were reviewed by 2 blinded examiners and categorized as adequate or inadequate visualization of the surgical repair. Based on TEE images, the surgical repair was graded as no revision necessary, residual lesion present requiring revision, or unable to assess. TEE was compared to completion angiography to determine the ability of each method to detect residual pulmonary artery lesions. Fifty-three percent of TEE imaging was graded as inadequate. Based on TEE, surgical revision was indicated in 2 of 19 cases. Completion angiography documented 4 additional residual lesions resulting in surgical revision in 6 of 19 patients. TEE sensitivity for detecting residual pulmonary artery lesions was 40%. One Glenn patient with adequate image quality and repair by TEE had moderate left pulmonary artery stenosis by completion angiography. All other discrepancies occurred in patients with inadequate TEE imaging. No patient with pulmonary artery abnormalities had hemodynamic instability or excessive desaturations. Completion angiography-related complications included three transient arrhythmias with no increased incidence of acute kidney injury. Completion angiography may be more effective than TEE at detecting post-operative pulmonary artery lesions even in patients not manifesting clinical symptoms. Documentation of residual lesions with completion angiography allows immediate surgical revision potentially limiting necessity for future interventions.
- 10 March 2018
- Published by Springer Nature in Pediatric Cardiology
- Vol. 39 (5) , 884-891
Intraoperative Completion Angiogram May Be Superior to Transesophageal Echocardiogram for Detection of Pulmonary Artery Residual Lesions in Congenital Heart Surgery
The purpose of this study was to assess the diagnostic capabilities of transesophageal echocardiography (TEE) compared to completion angiography for detection of residual post-operative pulmonary artery lesions. This is a retrospective review of 19 consecutive surgical cases involving the pulmonary arteries that had post-operative TEE and completion angiography from 2014 to 2017. The echocardiograms were reviewed by 2 blinded examiners and categorized as adequate or inadequate visualization of the surgical repair. Based on TEE images, the surgical repair was graded as no revision necessary, residual lesion present requiring revision, or unable to assess. TEE was compared to completion angiography to determine the ability of each method to detect residual pulmonary artery lesions. Fifty-three percent of TEE imaging was graded as inadequate. Based on TEE, surgical revision was indicated in 2 of 19 cases. Completion angiography documented 4 additional residual lesions resulting in surgical revision in 6 of 19 patients. TEE sensitivity for detecting residual pulmonary artery lesions was 40%. One Glenn patient with adequate image quality and repair by TEE had moderate left pulmonary artery stenosis by completion angiography. All other discrepancies occurred in patients with inadequate TEE imaging. No patient with pulmonary artery abnormalities had hemodynamic instability or excessive desaturations. Completion angiography-related complications included three transient arrhythmias with no increased incidence of acute kidney injury. Completion angiography may be more effective than TEE at detecting post-operative pulmonary artery lesions even in patients not manifesting clinical symptoms. Documentation of residual lesions with completion angiography allows immediate surgical revision potentially limiting necessity for future interventions.
- 28 July 2015
- Published by Springer Nature in Pediatric Cardiology
- Vol. 37 (1) , 24-29
Radiation Reduction Capabilities of a Next-Generation Pediatric Imaging Platform
The aims of this study were to quantify patient radiation exposure for a single interventional procedure during transition from an adult catheterization laboratory to a next-generation imaging system with pediatric settings, and to compare this radiation data to published benchmarks. Radiation exposure occurs with any X-ray-directed pediatric catheterization. Technologies and imaging techniques that limit dose while preserving image quality benefit patient care. Patient radiation dose metrics, air kerma, and dose–area product (DAP) were retrospectively obtained for patients n = 11) and a next-generation pediatric imaging system (Group 2, n = 10) with air-gap technique. Group 2 radiation dose metrics were then compared to published benchmarks. Patient demographics, procedural technique, PDA dimensions, closure devices, and fluoroscopy time were similar for the two groups. Air kerma and DAP decreased by 65–70 % in Group 2 (p values p value = 0.06); therefore, analysis of covariance (ANCOVA) was conducted that confirmed significantly lower dose measures in Group 2. This degree of dose reduction was similar when Group 2 data (Kerma 28 mGy, DAP 199 µGy m2) was compared to published benchmarks for PDA closure (Kerma 76 mGy, DAP 500 µGy m2). This is the first clinical study documenting the radiation reduction capabilities of a next-generation pediatric imaging platform. The true benefit of this dose reduction will be seen in patients requiring complex and often recurrent catheterizations.
- 28 July 2015
- Published by Springer Nature in Pediatric Cardiology
- Vol. 37 (1) , 24-29
Radiation Reduction Capabilities of a Next-Generation Pediatric Imaging Platform
The aims of this study were to quantify patient radiation exposure for a single interventional procedure during transition from an adult catheterization laboratory to a next-generation imaging system with pediatric settings, and to compare this radiation data to published benchmarks. Radiation exposure occurs with any X-ray-directed pediatric catheterization. Technologies and imaging techniques that limit dose while preserving image quality benefit patient care. Patient radiation dose metrics, air kerma, and dose–area product (DAP) were retrospectively obtained for patients n = 11) and a next-generation pediatric imaging system (Group 2, n = 10) with air-gap technique. Group 2 radiation dose metrics were then compared to published benchmarks. Patient demographics, procedural technique, PDA dimensions, closure devices, and fluoroscopy time were similar for the two groups. Air kerma and DAP decreased by 65–70 % in Group 2 (p values p value = 0.06); therefore, analysis of covariance (ANCOVA) was conducted that confirmed significantly lower dose measures in Group 2. This degree of dose reduction was similar when Group 2 data (Kerma 28 mGy, DAP 199 µGy m2) was compared to published benchmarks for PDA closure (Kerma 76 mGy, DAP 500 µGy m2). This is the first clinical study documenting the radiation reduction capabilities of a next-generation pediatric imaging platform. The true benefit of this dose reduction will be seen in patients requiring complex and often recurrent catheterizations.