Herman G. J. Smit
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Herman G. J. Smit has a total of 956 co-authors. Here are the top co-authors by number of shared publications:
- Roeland Van Malderen
Royal Meteorological Institute of Belgium, Brussels, Belgium
46 shared publications - Anne Mee Thompson
Earth Sciences Division, NASA Goddard Space Flight Center, Greenbelt, Maryland, USA
42 shared publications Bryan J. Johnson
NOAA Global Monitoring Laboratory, Boulder, CO, USA
39 shared publications- Ryan Michael Stauffer
Earth Sciences Division, NASA/Goddard Space Flight Center, Greenbelt, MD, USA
36 shared publications Debra E. Kollonige
Atmospheric Chemistry and Dynamics Laboratory, NASA Goddard Space Flight Center, Greenbelt, MD, USA
28 shared publications- Jane Liu
Department of Geography and Planning, University of Toronto, Toronto, Canada
23 shared publications
Latest Publications
- Open Access
- 14 March 2026
- Published by Copernicus GmbH
Insights into Potential Contrail Cirrus Regions During Surface Temperature Extremes from Three Decades of Airborne Measurements
Contrails and contrail cirrus, induced by civil aviation and posing a radiative warming threat to the climate, form and persist at high altitudes in the upper troposphere in regions characterized by low temperatures and high relative humidity with respect to ice (RHice). Both temperature and humidity are critical variables controlling the formation of contrails and contrail cirrus. Variability in RHice in the upper troposphere is intrinsically associated with changes in ambient temperature. Recent years have seen record-breaking surface temperatures, particularly across continental regions. However, the relationship between upper-tropospheric temperature and humidity and surface temperatures remains poorly understood.This work uses 30 years of airborne temperature and relative humidity measurements from the European Research Infrastructure IAGOS to investigate changes in Potential Contrail Cirrus Regions (PCCRs) in relation to surface temperature extremes (heatwaves and cold waves) over Europe. Surface temperature extremes are identified for each season using temperature measurements in the planetary boundary layer (
- 14 March 2026
- Published by Copernicus GmbH
Open AccessInsights into Potential Contrail Cirrus Regions During Surface Temperature Extremes from Three Decades of Airborne Measurements
Contrails and contrail cirrus, induced by civil aviation and posing a radiative warming threat to the climate, form and persist at high altitudes in the upper troposphere in regions characterized by low temperatures and high relative humidity with respect to ice (RHice). Both temperature and humidity are critical variables controlling the formation of contrails and contrail cirrus. Variability in RHice in the upper troposphere is intrinsically associated with changes in ambient temperature. Recent years have seen record-breaking surface temperatures, particularly across continental regions. However, the relationship between upper-tropospheric temperature and humidity and surface temperatures remains poorly understood.This work uses 30 years of airborne temperature and relative humidity measurements from the European Research Infrastructure IAGOS to investigate changes in Potential Contrail Cirrus Regions (PCCRs) in relation to surface temperature extremes (heatwaves and cold waves) over Europe. Surface temperature extremes are identified for each season using temperature measurements in the planetary boundary layer (
- Open Access
- 1 October 2025
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 18 (19) , 4985-5001
Intercomparison of IAGOS-CORE, IAGOS-CARIBIC and WMO/GAW-WCCOS Ozone Instruments at the Environmental Simulation Facility at Jülich, Germany
As part of the Quality Assurance (QA) plan of the In-service Aircraft for a Global Observation System (IAGOS), IAGOS-CORE and IAGOS-CARIBIC UV-photometer instruments have been compared with the dual-beam UV- Ozone (O3) PhotoMeter (OPM) of the World Calibration Center of Ozone Sondes (WCCOS) at the Forschungszentrum Jülich in an environmental simulation chamber. The WCCOS is established since about 30 years ago as part of the WMO-GAW measurement quality program of the global ozonesonde network, in which the OPM instrument serves as the ozone reference standard. In the simulation chamber, pressure, temperature, and ozone concentration can be controlled at quasi-realistic flight conditions between the Earth surface (∼ 1000 hPa) and ∼ 35 km altitude (5 hPa). During the intercomparison, different ascent/descent and cruise altitude profiles of ozone, pressure and temperature have been simulated between the surface and ∼ 12.5 km altitude (200 hPa). In general, the two O3 instruments P1-O3 (IAGOS-CORE) and CAR-O3 (IAGOS-CARIBIC) showed good agreement with the OPM reference standard within 5 %–6 %. At a pressure of 400–500 hPa the agreement was even within 2 %. The observed differences are small but systematic and reproducible during this experiment. CAR-O3 showed a small, pressure-independent deviation of −2 ± 1.5 % compared to the OPM. P1-O3 revealed O3 deviation to the OPM which changes with pressure of about +2 % at 1000 hPa to −3 % at 400 hPa, which might be an artefact on the experimental set-up and subject for further investigations. This intercomparison is a first step of the long-term goal to make the global ozone sonde data (GAW-NDACC-SHADOZ-GRUAN) and IAGOS-O3 (CORE: P1-O3, CARIBIC: CAR-O3) data traceable to one common reference, the OPM instrument of WCCOS. Recommendations are made for further regular (every two to three years) intercomparison of the operational instruments to ensure external consistency in general and specifically towards the synergy of IAGOS-O3 and ozonesonde data. An important gap in such intercomparison studies is the lack of a reference ozone instrument operated at reduced pressures at any National Metrological Institute in the world. For observation networks measuring vertical ozone profiles, it is essential to close this gap to enable the traceability of ozone measurements from different platforms to one reference standard. This is crucial to harmonize long-term ozone records to detect any changes of ozone in the free atmosphere.
- 1 October 2025
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 18 (19) , 4985-5001
Open AccessIntercomparison of IAGOS-CORE, IAGOS-CARIBIC and WMO/GAW-WCCOS Ozone Instruments at the Environmental Simulation Facility at Jülich, Germany
As part of the Quality Assurance (QA) plan of the In-service Aircraft for a Global Observation System (IAGOS), IAGOS-CORE and IAGOS-CARIBIC UV-photometer instruments have been compared with the dual-beam UV- Ozone (O3) PhotoMeter (OPM) of the World Calibration Center of Ozone Sondes (WCCOS) at the Forschungszentrum Jülich in an environmental simulation chamber. The WCCOS is established since about 30 years ago as part of the WMO-GAW measurement quality program of the global ozonesonde network, in which the OPM instrument serves as the ozone reference standard. In the simulation chamber, pressure, temperature, and ozone concentration can be controlled at quasi-realistic flight conditions between the Earth surface (∼ 1000 hPa) and ∼ 35 km altitude (5 hPa). During the intercomparison, different ascent/descent and cruise altitude profiles of ozone, pressure and temperature have been simulated between the surface and ∼ 12.5 km altitude (200 hPa). In general, the two O3 instruments P1-O3 (IAGOS-CORE) and CAR-O3 (IAGOS-CARIBIC) showed good agreement with the OPM reference standard within 5 %–6 %. At a pressure of 400–500 hPa the agreement was even within 2 %. The observed differences are small but systematic and reproducible during this experiment. CAR-O3 showed a small, pressure-independent deviation of −2 ± 1.5 % compared to the OPM. P1-O3 revealed O3 deviation to the OPM which changes with pressure of about +2 % at 1000 hPa to −3 % at 400 hPa, which might be an artefact on the experimental set-up and subject for further investigations. This intercomparison is a first step of the long-term goal to make the global ozone sonde data (GAW-NDACC-SHADOZ-GRUAN) and IAGOS-O3 (CORE: P1-O3, CARIBIC: CAR-O3) data traceable to one common reference, the OPM instrument of WCCOS. Recommendations are made for further regular (every two to three years) intercomparison of the operational instruments to ensure external consistency in general and specifically towards the synergy of IAGOS-O3 and ozonesonde data. An important gap in such intercomparison studies is the lack of a reference ozone instrument operated at reduced pressures at any National Metrological Institute in the world. For observation networks measuring vertical ozone profiles, it is essential to close this gap to enable the traceability of ozone measurements from different platforms to one reference standard. This is crucial to harmonize long-term ozone records to detect any changes of ozone in the free atmosphere.
- Open Access
- 5 September 2025
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 25 (17) , 9905-9935
Ground-based tropospheric ozone measurements: regional tropospheric ozone column trends from the TOAR-II/HEGIFTOM homogenized datasets
Quantifying long-term free-tropospheric ozone trends is essential for understanding the impact of human activities and climate change on atmospheric chemistry. However, this is complicated by two key challenges: the differences among existing satellite-derived tropospheric ozone products, which are not yet fully understood or reconciled, and the limited temporal and spatial coverage of ground-based reference measurements. Here, we explore if a more consistent understanding of the geographical distribution of tropospheric ozone column (TrOC) trends can be obtained by focusing on regional trends from ground-based measurements. Regions were determined with a correlation analysis between modeled TrOCs at the site locations. For those regions, TrOC trends were estimated with quantile regression for the Trajectory-mapped Ozonesonde dataset for the Stratosphere and Troposphere (TOST) and with a linear mixed-effects modeling (LMM) approach to calculate synthesized trends from homogenized HEGIFTOM (Harmonization and Evaluation of Ground-based Instruments for Free-Tropospheric Ozone Measurements) individual site trends. For different periods (1990–2021/22, 1995–2021/22, 2000–2021/22), both approaches give increasing (partial) tropospheric ozone column amounts over almost all Asian regions (median confidence) and negative trends over Arctic regions (very high confidence). Trends over Europe and North America are mostly weakly positive (LMM) or negative (TOST). For both approaches, the 2000–2021/22 trends decreased in magnitude compared to 1995–2021/22 for most regions; and for all time periods and regions, the pre-COVID trends are larger than the post-COVID trends. Our results enable the validation of global satellite TrOC trends and assessment of the performance of atmospheric chemistry models to represent the distribution and variation of TrOC.
- 5 September 2025
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 25 (17) , 9905-9935
Open AccessGround-based tropospheric ozone measurements: regional tropospheric ozone column trends from the TOAR-II/HEGIFTOM homogenized datasets
Quantifying long-term free-tropospheric ozone trends is essential for understanding the impact of human activities and climate change on atmospheric chemistry. However, this is complicated by two key challenges: the differences among existing satellite-derived tropospheric ozone products, which are not yet fully understood or reconciled, and the limited temporal and spatial coverage of ground-based reference measurements. Here, we explore if a more consistent understanding of the geographical distribution of tropospheric ozone column (TrOC) trends can be obtained by focusing on regional trends from ground-based measurements. Regions were determined with a correlation analysis between modeled TrOCs at the site locations. For those regions, TrOC trends were estimated with quantile regression for the Trajectory-mapped Ozonesonde dataset for the Stratosphere and Troposphere (TOST) and with a linear mixed-effects modeling (LMM) approach to calculate synthesized trends from homogenized HEGIFTOM (Harmonization and Evaluation of Ground-based Instruments for Free-Tropospheric Ozone Measurements) individual site trends. For different periods (1990–2021/22, 1995–2021/22, 2000–2021/22), both approaches give increasing (partial) tropospheric ozone column amounts over almost all Asian regions (median confidence) and negative trends over Arctic regions (very high confidence). Trends over Europe and North America are mostly weakly positive (LMM) or negative (TOST). For both approaches, the 2000–2021/22 trends decreased in magnitude compared to 1995–2021/22 for most regions; and for all time periods and regions, the pre-COVID trends are larger than the post-COVID trends. Our results enable the validation of global satellite TrOC trends and assessment of the performance of atmospheric chemistry models to represent the distribution and variation of TrOC.
- Top Cited PapersOpen Access
- 11 July 2025
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 25 (13) , 7187-7225
Global ground-based tropospheric ozone measurements: reference data and individual site trends (2000–2022) from the TOAR-II/HEGIFTOM project
Tropospheric ozone trends from models and satellites are found to diverge. Ground-based (GB) observations are used to reference models and satellites, but GB data themselves might display station biases and discontinuities. Reprocessing with uniform procedures, the TOAR-II working group Harmonization and Evaluation of Ground-based Instruments for Free-Tropospheric Ozone Measurements (HEGIFTOM) homogenized public data from five networks: ozonesondes, In-service Aircraft for a Global Observing System (IAGOS) profiles, solar absorption Fourier transform infrared (FTIR) spectrometer measurements, lidar observations, and Dobson Umkehr data. Amounts and uncertainties for total tropospheric ozone (TrOC; surface to 300 hPa), as well as free- and lower-tropospheric ozone, are calculated for each network. We report trends (2000 to 2022) for these segments using quantile regression (QR) and multiple linear regression (MLR) for 55 datasets, including six multi-instrument stations. The findings are that (1) median TrOC trends computed with QR and MLR trends are essentially the same; (2) pole-to-pole, across all longitudes, TrOC trends fall within +3 to −3 ppbv per decade, equivalent to (−4 % to +8 %) per decade depending on site; (3) the greatest fractional increases occur over most tropical and subtropical sites, with decreases at northern high latitudes, but these patterns are not uniform; (4) post-COVID trends are smaller than pre-COVID trends for Northern Hemisphere mid-latitude sites. In summary, this analysis conducted in the frame of TOAR-II/HEGIFTOM shows that high-quality, multi-instrument, harmonized data over a wide range of ground sites provide clear standard references for TOAR-II models and evolving tropospheric ozone satellite products for 2000–2022.
- 11 July 2025
- Published by Copernicus GmbH in Atmospheric Chemistry and Physics
- Vol. 25 (13) , 7187-7225
Top Cited PapersOpen AccessGlobal ground-based tropospheric ozone measurements: reference data and individual site trends (2000–2022) from the TOAR-II/HEGIFTOM project
Tropospheric ozone trends from models and satellites are found to diverge. Ground-based (GB) observations are used to reference models and satellites, but GB data themselves might display station biases and discontinuities. Reprocessing with uniform procedures, the TOAR-II working group Harmonization and Evaluation of Ground-based Instruments for Free-Tropospheric Ozone Measurements (HEGIFTOM) homogenized public data from five networks: ozonesondes, In-service Aircraft for a Global Observing System (IAGOS) profiles, solar absorption Fourier transform infrared (FTIR) spectrometer measurements, lidar observations, and Dobson Umkehr data. Amounts and uncertainties for total tropospheric ozone (TrOC; surface to 300 hPa), as well as free- and lower-tropospheric ozone, are calculated for each network. We report trends (2000 to 2022) for these segments using quantile regression (QR) and multiple linear regression (MLR) for 55 datasets, including six multi-instrument stations. The findings are that (1) median TrOC trends computed with QR and MLR trends are essentially the same; (2) pole-to-pole, across all longitudes, TrOC trends fall within +3 to −3 ppbv per decade, equivalent to (−4 % to +8 %) per decade depending on site; (3) the greatest fractional increases occur over most tropical and subtropical sites, with decreases at northern high latitudes, but these patterns are not uniform; (4) post-COVID trends are smaller than pre-COVID trends for Northern Hemisphere mid-latitude sites. In summary, this analysis conducted in the frame of TOAR-II/HEGIFTOM shows that high-quality, multi-instrument, harmonized data over a wide range of ground sites provide clear standard references for TOAR-II models and evolving tropospheric ozone satellite products for 2000–2022.
- Open Access
- 8 July 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-28
Reply on RC2
In the frame of the Quality Assurance (QA) plan of the In-service Aircraft for a Global Observation System (IAGOS), IAGOS-CORE and IAGOS-CARIBIC UV-photometer instruments have been compared with the dual-beam UV- Ozone (O3) PhotoMeter (OPM) of the World Calibration Center of Ozone Sondes (WCCOS) at the Forschungszentrum Jülich in an environmental simulation chamber. The WCCOS is established as part of the WMO-GAW measurement quality program of the global ozonesonde network for more than 30 years, in which the OPM instrument serves as the ozone reference standard. In the simulation chamber, pressure, temperature, and ozone concentration can be controlled at quasi-realistic flight conditions between the Earth surface (~1000 hPa) and ~35 km altitude (5 hPa). During the intercomparison, different ascent/descent and cruise altitude profiles of ozone, pressure and temperature have been simulated between the surface and ~12 km altitude (200 hPa). In general, the two O3 instruments P1-O3 (IAGOS-CORE) and CAR-O3 (IAGOS-CARIBIC) showed good agreement with the OPM reference standard within 5–6 %. At a pressure of 400–500 hPa the agreement was even within 2 %. The observed differences are small but systematic and reproducible during this experiment. CAR-O3 showed a small, but pressure independent deviation of -(1.5–2.5) % ± 1.5 % compared to the OPM. P1-O3 revealed O3 deviation to the OPM which changes with pressure of about +2 % at 1000 hPa to -3 % at 400 hPa, which might be an artefact on the experimental set-up and subject for further investigations. This intercomparison is a first step of the long-term goal to get the global ozone sonde data (GAW-NDACC-SHADOZ-GRUAN) and IAGOS-O3 (CORE: P1-O3, CARIBIC: CAR-O3) data traceable to one common reference, the OPM instrument of WCCOS. Recommendations are given for further regular validation of the flown instruments on external consistency in general and specifically towards the synergy of IAGOS-O3 and ozonesonde data.
- 8 July 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-28
Open AccessReply on RC2
In the frame of the Quality Assurance (QA) plan of the In-service Aircraft for a Global Observation System (IAGOS), IAGOS-CORE and IAGOS-CARIBIC UV-photometer instruments have been compared with the dual-beam UV- Ozone (O3) PhotoMeter (OPM) of the World Calibration Center of Ozone Sondes (WCCOS) at the Forschungszentrum Jülich in an environmental simulation chamber. The WCCOS is established as part of the WMO-GAW measurement quality program of the global ozonesonde network for more than 30 years, in which the OPM instrument serves as the ozone reference standard. In the simulation chamber, pressure, temperature, and ozone concentration can be controlled at quasi-realistic flight conditions between the Earth surface (~1000 hPa) and ~35 km altitude (5 hPa). During the intercomparison, different ascent/descent and cruise altitude profiles of ozone, pressure and temperature have been simulated between the surface and ~12 km altitude (200 hPa). In general, the two O3 instruments P1-O3 (IAGOS-CORE) and CAR-O3 (IAGOS-CARIBIC) showed good agreement with the OPM reference standard within 5–6 %. At a pressure of 400–500 hPa the agreement was even within 2 %. The observed differences are small but systematic and reproducible during this experiment. CAR-O3 showed a small, but pressure independent deviation of -(1.5–2.5) % ± 1.5 % compared to the OPM. P1-O3 revealed O3 deviation to the OPM which changes with pressure of about +2 % at 1000 hPa to -3 % at 400 hPa, which might be an artefact on the experimental set-up and subject for further investigations. This intercomparison is a first step of the long-term goal to get the global ozone sonde data (GAW-NDACC-SHADOZ-GRUAN) and IAGOS-O3 (CORE: P1-O3, CARIBIC: CAR-O3) data traceable to one common reference, the OPM instrument of WCCOS. Recommendations are given for further regular validation of the flown instruments on external consistency in general and specifically towards the synergy of IAGOS-O3 and ozonesonde data.
- Open Access
- 8 July 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-28
Reply on RC1
In the frame of the Quality Assurance (QA) plan of the In-service Aircraft for a Global Observation System (IAGOS), IAGOS-CORE and IAGOS-CARIBIC UV-photometer instruments have been compared with the dual-beam UV- Ozone (O3) PhotoMeter (OPM) of the World Calibration Center of Ozone Sondes (WCCOS) at the Forschungszentrum Jülich in an environmental simulation chamber. The WCCOS is established as part of the WMO-GAW measurement quality program of the global ozonesonde network for more than 30 years, in which the OPM instrument serves as the ozone reference standard. In the simulation chamber, pressure, temperature, and ozone concentration can be controlled at quasi-realistic flight conditions between the Earth surface (~1000 hPa) and ~35 km altitude (5 hPa). During the intercomparison, different ascent/descent and cruise altitude profiles of ozone, pressure and temperature have been simulated between the surface and ~12 km altitude (200 hPa). In general, the two O3 instruments P1-O3 (IAGOS-CORE) and CAR-O3 (IAGOS-CARIBIC) showed good agreement with the OPM reference standard within 5–6 %. At a pressure of 400–500 hPa the agreement was even within 2 %. The observed differences are small but systematic and reproducible during this experiment. CAR-O3 showed a small, but pressure independent deviation of -(1.5–2.5) % ± 1.5 % compared to the OPM. P1-O3 revealed O3 deviation to the OPM which changes with pressure of about +2 % at 1000 hPa to -3 % at 400 hPa, which might be an artefact on the experimental set-up and subject for further investigations. This intercomparison is a first step of the long-term goal to get the global ozone sonde data (GAW-NDACC-SHADOZ-GRUAN) and IAGOS-O3 (CORE: P1-O3, CARIBIC: CAR-O3) data traceable to one common reference, the OPM instrument of WCCOS. Recommendations are given for further regular validation of the flown instruments on external consistency in general and specifically towards the synergy of IAGOS-O3 and ozonesonde data.
- 8 July 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-28
Open AccessReply on RC1
In the frame of the Quality Assurance (QA) plan of the In-service Aircraft for a Global Observation System (IAGOS), IAGOS-CORE and IAGOS-CARIBIC UV-photometer instruments have been compared with the dual-beam UV- Ozone (O3) PhotoMeter (OPM) of the World Calibration Center of Ozone Sondes (WCCOS) at the Forschungszentrum Jülich in an environmental simulation chamber. The WCCOS is established as part of the WMO-GAW measurement quality program of the global ozonesonde network for more than 30 years, in which the OPM instrument serves as the ozone reference standard. In the simulation chamber, pressure, temperature, and ozone concentration can be controlled at quasi-realistic flight conditions between the Earth surface (~1000 hPa) and ~35 km altitude (5 hPa). During the intercomparison, different ascent/descent and cruise altitude profiles of ozone, pressure and temperature have been simulated between the surface and ~12 km altitude (200 hPa). In general, the two O3 instruments P1-O3 (IAGOS-CORE) and CAR-O3 (IAGOS-CARIBIC) showed good agreement with the OPM reference standard within 5–6 %. At a pressure of 400–500 hPa the agreement was even within 2 %. The observed differences are small but systematic and reproducible during this experiment. CAR-O3 showed a small, but pressure independent deviation of -(1.5–2.5) % ± 1.5 % compared to the OPM. P1-O3 revealed O3 deviation to the OPM which changes with pressure of about +2 % at 1000 hPa to -3 % at 400 hPa, which might be an artefact on the experimental set-up and subject for further investigations. This intercomparison is a first step of the long-term goal to get the global ozone sonde data (GAW-NDACC-SHADOZ-GRUAN) and IAGOS-O3 (CORE: P1-O3, CARIBIC: CAR-O3) data traceable to one common reference, the OPM instrument of WCCOS. Recommendations are given for further regular validation of the flown instruments on external consistency in general and specifically towards the synergy of IAGOS-O3 and ozonesonde data.
- Open Access
- 8 May 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-28
Comment on egusphere-2024-3760
In the frame of the Quality Assurance (QA) plan of the In-service Aircraft for a Global Observation System (IAGOS), IAGOS-CORE and IAGOS-CARIBIC UV-photometer instruments have been compared with the dual-beam UV- Ozone (O3) PhotoMeter (OPM) of the World Calibration Center of Ozone Sondes (WCCOS) at the Forschungszentrum Jülich in an environmental simulation chamber. The WCCOS is established as part of the WMO-GAW measurement quality program of the global ozonesonde network for more than 30 years, in which the OPM instrument serves as the ozone reference standard. In the simulation chamber, pressure, temperature, and ozone concentration can be controlled at quasi-realistic flight conditions between the Earth surface (~1000 hPa) and ~35 km altitude (5 hPa). During the intercomparison, different ascent/descent and cruise altitude profiles of ozone, pressure and temperature have been simulated between the surface and ~12 km altitude (200 hPa). In general, the two O3 instruments P1-O3 (IAGOS-CORE) and CAR-O3 (IAGOS-CARIBIC) showed good agreement with the OPM reference standard within 5–6 %. At a pressure of 400–500 hPa the agreement was even within 2 %. The observed differences are small but systematic and reproducible during this experiment. CAR-O3 showed a small, but pressure independent deviation of -(1.5–2.5) % ± 1.5 % compared to the OPM. P1-O3 revealed O3 deviation to the OPM which changes with pressure of about +2 % at 1000 hPa to -3 % at 400 hPa, which might be an artefact on the experimental set-up and subject for further investigations. This intercomparison is a first step of the long-term goal to get the global ozone sonde data (GAW-NDACC-SHADOZ-GRUAN) and IAGOS-O3 (CORE: P1-O3, CARIBIC: CAR-O3) data traceable to one common reference, the OPM instrument of WCCOS. Recommendations are given for further regular validation of the flown instruments on external consistency in general and specifically towards the synergy of IAGOS-O3 and ozonesonde data.
- 8 May 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-28
Open AccessComment on egusphere-2024-3760
In the frame of the Quality Assurance (QA) plan of the In-service Aircraft for a Global Observation System (IAGOS), IAGOS-CORE and IAGOS-CARIBIC UV-photometer instruments have been compared with the dual-beam UV- Ozone (O3) PhotoMeter (OPM) of the World Calibration Center of Ozone Sondes (WCCOS) at the Forschungszentrum Jülich in an environmental simulation chamber. The WCCOS is established as part of the WMO-GAW measurement quality program of the global ozonesonde network for more than 30 years, in which the OPM instrument serves as the ozone reference standard. In the simulation chamber, pressure, temperature, and ozone concentration can be controlled at quasi-realistic flight conditions between the Earth surface (~1000 hPa) and ~35 km altitude (5 hPa). During the intercomparison, different ascent/descent and cruise altitude profiles of ozone, pressure and temperature have been simulated between the surface and ~12 km altitude (200 hPa). In general, the two O3 instruments P1-O3 (IAGOS-CORE) and CAR-O3 (IAGOS-CARIBIC) showed good agreement with the OPM reference standard within 5–6 %. At a pressure of 400–500 hPa the agreement was even within 2 %. The observed differences are small but systematic and reproducible during this experiment. CAR-O3 showed a small, but pressure independent deviation of -(1.5–2.5) % ± 1.5 % compared to the OPM. P1-O3 revealed O3 deviation to the OPM which changes with pressure of about +2 % at 1000 hPa to -3 % at 400 hPa, which might be an artefact on the experimental set-up and subject for further investigations. This intercomparison is a first step of the long-term goal to get the global ozone sonde data (GAW-NDACC-SHADOZ-GRUAN) and IAGOS-O3 (CORE: P1-O3, CARIBIC: CAR-O3) data traceable to one common reference, the OPM instrument of WCCOS. Recommendations are given for further regular validation of the flown instruments on external consistency in general and specifically towards the synergy of IAGOS-O3 and ozonesonde data.
- Open Access
- 16 April 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-41
Comment on egusphere-2024-3745
The quantification of long-term free-tropospheric ozone trends is essential for understanding the impact of human activities and climate change on atmospheric chemistry, but is challenged by the diversity between satellite tropospheric ozone records and the sparse temporal and spatial sampling of ground-based measurements. Here, we explore if a more consistent understanding of the geographical distribution of tropospheric ozone column (TrOC) trends can be obtained by focusing on regional trends calculated from ground-based measurements. Regions were determined with a correlation analysis between modelled TrOCs at the site locations. For those regions, TrOC trends were estimated with Quantile Regression and Dynamical Linear Modelling for the Trajectory-mapped Ozonesonde dataset for the Stratosphere and Troposphere (TOST), and with a linear mixed-effects modelling (LMM) approach to calculate synthesized trends from the homogenized HEGIFTOM (Harmonization and Evaluation of Ground-based Instruments for Free-Tropospheric Ozone Measurements) individual site trends. For different periods (1990–2021/22, 1995–2021/22, 2000–2021/22), both approaches give increasing (partial) tropospheric ozone column amounts over almost all Asian regions (median confidence), and negative trends over the Arctic regions (very high confidence). Trends over Europe and North America are mostly weakly positive (LMM method) or negative (TOST). For both approaches, the 2000–2021/22 trends decreased in magnitude compared to the 1995–2021/22 for most of the regions, and for all time periods and regions, the pre-COVID trends are larger than the post-COVID trends. Our results enable the validation of global satellite TrOC trends, and assessment of the performance of atmospheric chemistry models to represent the distribution and variation of TrOC.
- 16 April 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-41
Open AccessComment on egusphere-2024-3745
The quantification of long-term free-tropospheric ozone trends is essential for understanding the impact of human activities and climate change on atmospheric chemistry, but is challenged by the diversity between satellite tropospheric ozone records and the sparse temporal and spatial sampling of ground-based measurements. Here, we explore if a more consistent understanding of the geographical distribution of tropospheric ozone column (TrOC) trends can be obtained by focusing on regional trends calculated from ground-based measurements. Regions were determined with a correlation analysis between modelled TrOCs at the site locations. For those regions, TrOC trends were estimated with Quantile Regression and Dynamical Linear Modelling for the Trajectory-mapped Ozonesonde dataset for the Stratosphere and Troposphere (TOST), and with a linear mixed-effects modelling (LMM) approach to calculate synthesized trends from the homogenized HEGIFTOM (Harmonization and Evaluation of Ground-based Instruments for Free-Tropospheric Ozone Measurements) individual site trends. For different periods (1990–2021/22, 1995–2021/22, 2000–2021/22), both approaches give increasing (partial) tropospheric ozone column amounts over almost all Asian regions (median confidence), and negative trends over the Arctic regions (very high confidence). Trends over Europe and North America are mostly weakly positive (LMM method) or negative (TOST). For both approaches, the 2000–2021/22 trends decreased in magnitude compared to the 1995–2021/22 for most of the regions, and for all time periods and regions, the pre-COVID trends are larger than the post-COVID trends. Our results enable the validation of global satellite TrOC trends, and assessment of the performance of atmospheric chemistry models to represent the distribution and variation of TrOC.
- Open Access
- 13 March 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-41
Comment on egusphere-2024-3745
The quantification of long-term free-tropospheric ozone trends is essential for understanding the impact of human activities and climate change on atmospheric chemistry, but is challenged by the diversity between satellite tropospheric ozone records and the sparse temporal and spatial sampling of ground-based measurements. Here, we explore if a more consistent understanding of the geographical distribution of tropospheric ozone column (TrOC) trends can be obtained by focusing on regional trends calculated from ground-based measurements. Regions were determined with a correlation analysis between modelled TrOCs at the site locations. For those regions, TrOC trends were estimated with Quantile Regression and Dynamical Linear Modelling for the Trajectory-mapped Ozonesonde dataset for the Stratosphere and Troposphere (TOST), and with a linear mixed-effects modelling (LMM) approach to calculate synthesized trends from the homogenized HEGIFTOM (Harmonization and Evaluation of Ground-based Instruments for Free-Tropospheric Ozone Measurements) individual site trends. For different periods (1990–2021/22, 1995–2021/22, 2000–2021/22), both approaches give increasing (partial) tropospheric ozone column amounts over almost all Asian regions (median confidence), and negative trends over the Arctic regions (very high confidence). Trends over Europe and North America are mostly weakly positive (LMM method) or negative (TOST). For both approaches, the 2000–2021/22 trends decreased in magnitude compared to the 1995–2021/22 for most of the regions, and for all time periods and regions, the pre-COVID trends are larger than the post-COVID trends. Our results enable the validation of global satellite TrOC trends, and assessment of the performance of atmospheric chemistry models to represent the distribution and variation of TrOC.
- 13 March 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-41
Open AccessComment on egusphere-2024-3745
The quantification of long-term free-tropospheric ozone trends is essential for understanding the impact of human activities and climate change on atmospheric chemistry, but is challenged by the diversity between satellite tropospheric ozone records and the sparse temporal and spatial sampling of ground-based measurements. Here, we explore if a more consistent understanding of the geographical distribution of tropospheric ozone column (TrOC) trends can be obtained by focusing on regional trends calculated from ground-based measurements. Regions were determined with a correlation analysis between modelled TrOCs at the site locations. For those regions, TrOC trends were estimated with Quantile Regression and Dynamical Linear Modelling for the Trajectory-mapped Ozonesonde dataset for the Stratosphere and Troposphere (TOST), and with a linear mixed-effects modelling (LMM) approach to calculate synthesized trends from the homogenized HEGIFTOM (Harmonization and Evaluation of Ground-based Instruments for Free-Tropospheric Ozone Measurements) individual site trends. For different periods (1990–2021/22, 1995–2021/22, 2000–2021/22), both approaches give increasing (partial) tropospheric ozone column amounts over almost all Asian regions (median confidence), and negative trends over the Arctic regions (very high confidence). Trends over Europe and North America are mostly weakly positive (LMM method) or negative (TOST). For both approaches, the 2000–2021/22 trends decreased in magnitude compared to the 1995–2021/22 for most of the regions, and for all time periods and regions, the pre-COVID trends are larger than the post-COVID trends. Our results enable the validation of global satellite TrOC trends, and assessment of the performance of atmospheric chemistry models to represent the distribution and variation of TrOC.
- Open Access
- 18 February 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-28
Comment on egusphere-2024-3760
In the frame of the Quality Assurance (QA) plan of the In-service Aircraft for a Global Observation System (IAGOS), IAGOS-CORE and IAGOS-CARIBIC UV-photometer instruments have been compared with the dual-beam UV- Ozone (O3) PhotoMeter (OPM) of the World Calibration Center of Ozone Sondes (WCCOS) at the Forschungszentrum Jülich in an environmental simulation chamber. The WCCOS is established as part of the WMO-GAW measurement quality program of the global ozonesonde network for more than 30 years, in which the OPM instrument serves as the ozone reference standard. In the simulation chamber, pressure, temperature, and ozone concentration can be controlled at quasi-realistic flight conditions between the Earth surface (~1000 hPa) and ~35 km altitude (5 hPa). During the intercomparison, different ascent/descent and cruise altitude profiles of ozone, pressure and temperature have been simulated between the surface and ~12 km altitude (200 hPa). In general, the two O3 instruments P1-O3 (IAGOS-CORE) and CAR-O3 (IAGOS-CARIBIC) showed good agreement with the OPM reference standard within 5–6 %. At a pressure of 400–500 hPa the agreement was even within 2 %. The observed differences are small but systematic and reproducible during this experiment. CAR-O3 showed a small, but pressure independent deviation of -(1.5–2.5) % ± 1.5 % compared to the OPM. P1-O3 revealed O3 deviation to the OPM which changes with pressure of about +2 % at 1000 hPa to -3 % at 400 hPa, which might be an artefact on the experimental set-up and subject for further investigations. This intercomparison is a first step of the long-term goal to get the global ozone sonde data (GAW-NDACC-SHADOZ-GRUAN) and IAGOS-O3 (CORE: P1-O3, CARIBIC: CAR-O3) data traceable to one common reference, the OPM instrument of WCCOS. Recommendations are given for further regular validation of the flown instruments on external consistency in general and specifically towards the synergy of IAGOS-O3 and ozonesonde data.
- 18 February 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-28
Open AccessComment on egusphere-2024-3760
In the frame of the Quality Assurance (QA) plan of the In-service Aircraft for a Global Observation System (IAGOS), IAGOS-CORE and IAGOS-CARIBIC UV-photometer instruments have been compared with the dual-beam UV- Ozone (O3) PhotoMeter (OPM) of the World Calibration Center of Ozone Sondes (WCCOS) at the Forschungszentrum Jülich in an environmental simulation chamber. The WCCOS is established as part of the WMO-GAW measurement quality program of the global ozonesonde network for more than 30 years, in which the OPM instrument serves as the ozone reference standard. In the simulation chamber, pressure, temperature, and ozone concentration can be controlled at quasi-realistic flight conditions between the Earth surface (~1000 hPa) and ~35 km altitude (5 hPa). During the intercomparison, different ascent/descent and cruise altitude profiles of ozone, pressure and temperature have been simulated between the surface and ~12 km altitude (200 hPa). In general, the two O3 instruments P1-O3 (IAGOS-CORE) and CAR-O3 (IAGOS-CARIBIC) showed good agreement with the OPM reference standard within 5–6 %. At a pressure of 400–500 hPa the agreement was even within 2 %. The observed differences are small but systematic and reproducible during this experiment. CAR-O3 showed a small, but pressure independent deviation of -(1.5–2.5) % ± 1.5 % compared to the OPM. P1-O3 revealed O3 deviation to the OPM which changes with pressure of about +2 % at 1000 hPa to -3 % at 400 hPa, which might be an artefact on the experimental set-up and subject for further investigations. This intercomparison is a first step of the long-term goal to get the global ozone sonde data (GAW-NDACC-SHADOZ-GRUAN) and IAGOS-O3 (CORE: P1-O3, CARIBIC: CAR-O3) data traceable to one common reference, the OPM instrument of WCCOS. Recommendations are given for further regular validation of the flown instruments on external consistency in general and specifically towards the synergy of IAGOS-O3 and ozonesonde data.