Jorge Cesar Masini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jorge Cesar Masini has a total of 185 co-authors. Here are the top co-authors by number of shared publications:
Gilberto Abate
Departamento de Química, Universidade Federal do Paraná, Curitiba, Brazil
17 shared publicationsFernando H. Do Nascimento
Departamento de Química Fundamental, Instituto de Química, Universidade de São Paulo, Av. Prof. Lineu Prestes 748, São Paulo, 05508-000, SP, Brazil
12 shared publicationsCarlos M. C. Infante
Instituto de Química, Universidade de Brasília, Campus Universitário Darcy Ribeiro, Brasília, Brazil
7 shared publicationsJaim Lichtig
Universidade de Sao Paulo, Sao Paulo, Brasil
7 shared publicationsMarilda Rigobello-Masini
Instituto de Química, Universidade de São Paulo, São Paulo, SP, Brazil
7 shared publicationsLuciana B.O. dos Santos
Instituto de Quimica, Universidade de São Paulo, C.P. 26077, 05513-970, São Paulo, SP, Brazil
6 shared publications
Latest Publications
- 14 July 2026
- Published by Wiley in Journal of Separation Science
- Vol. 49 (7) , e70491
A Quick and Simple Chromatographic Method to Investigate the Adsorption of Glufosinate on a Subtropical Oxisol: Affinity Comparisons With Glyphosate
This work presents a fast and straightforward chromatographic method with fluorescence detection to quantify glufosinate in soil solutions. The method is based on the reaction between the primary amine group of glufosinate and o‐ phthaldialdehyde with 2‐mercaptoethanol, producing a stable fluorescent derivative in under 2 min, which remains stable for more than 70 min (relative standard deviation [RSD] = 3.6%). The method does not require automated timing systems. Glyphosate, which lacks a primary amine, does not interfere, and potential interferences from aminomethyl phosphonic acid and ammonium are effectively circumvented by chromatographic separation, as their indole derivatives are well resolved from the glufosinate derivative. An isocratic chromatographic run using 20:80 methanol:piperazine‐ N , N ′‐bis(2‐ethanesulfonic acid) buffer at 1.0 mL/min lasts 5 min. The method showed linearity over the concentration range of 0.10 and 20 µmol/L, with detection and quantification limits of 0.015 and 0.050 µmol/L, respectively. Calibration curve reproducibility is high (slope RSD < 2.1%, n = 5). The method was effectively applied to study glufosinate adsorption in an Oxisol, revealing a maximum adsorption capacity of 2.5 ± 0.2 µmol/g, significantly lower than that reported for glyphosate.
- 14 July 2026
- Published by Wiley in Journal of Separation Science
- Vol. 49 (7) , e70491
A Quick and Simple Chromatographic Method to Investigate the Adsorption of Glufosinate on a Subtropical Oxisol: Affinity Comparisons With Glyphosate
This work presents a fast and straightforward chromatographic method with fluorescence detection to quantify glufosinate in soil solutions. The method is based on the reaction between the primary amine group of glufosinate and o‐ phthaldialdehyde with 2‐mercaptoethanol, producing a stable fluorescent derivative in under 2 min, which remains stable for more than 70 min (relative standard deviation [RSD] = 3.6%). The method does not require automated timing systems. Glyphosate, which lacks a primary amine, does not interfere, and potential interferences from aminomethyl phosphonic acid and ammonium are effectively circumvented by chromatographic separation, as their indole derivatives are well resolved from the glufosinate derivative. An isocratic chromatographic run using 20:80 methanol:piperazine‐ N , N ′‐bis(2‐ethanesulfonic acid) buffer at 1.0 mL/min lasts 5 min. The method showed linearity over the concentration range of 0.10 and 20 µmol/L, with detection and quantification limits of 0.015 and 0.050 µmol/L, respectively. Calibration curve reproducibility is high (slope RSD < 2.1%, n = 5). The method was effectively applied to study glufosinate adsorption in an Oxisol, revealing a maximum adsorption capacity of 2.5 ± 0.2 µmol/g, significantly lower than that reported for glyphosate.
- 26 June 2026
- Published by Wiley in Separation Science Plus
- Vol. 9 (7) , e70271
Polymeric Microbore Monolithic Column for the Fast Determination of Milk Whey Proteins in Powder Supplements by Reversed‐phase Liquid Chromatography
A rapid reversed‐phase liquid chromatographic method was developed for the separation and quantification of major whey proteins in dietary supplements using a poly(butyl methacrylate–co–ethylene dimethacrylate) monolithic column. The column structure was characterized by scanning electron microscopy, revealing a homogeneous porous network composed of ∼1 µm polymer globules and large flow‐through pores, which together provide high permeability and low backpressure, suitable for fast separations. Under a steep acetonitrile gradient, α‐lactalbumin (α‐LA), bovine serum albumin (BSA), and β‐lactoglobulin (β‐LG) were separated within 4 min, showing good peak symmetry and repeatable retention factors. The method exhibited excellent linearity ( R 2 > 0.99) over the concentration range of 0.025–0.91 mg/mL, with limits of detection ranging from 2.7 µg/mL for BSA to 6.2 µg/mL for β‐LG. Furthermore, analysis of three commercial whey protein supplements showed high intermediate precision (evaluated over three different days), with relative standard deviations below 6.0% for the major proteins (α‐LA and β‐LG) and under 12.5% for the minor component (BSA). Spike‐and‐recovery experiments confirmed the accuracy and reliability of the proposed method, yielding recovery rates ranging from 97% to 113%. β‐LG was the predominant protein, followed by α‐LA and minor amounts of BSA. The proposed approach provided fast analysis and low consumption of solvent and sample, with acceptable chromatographic efficiency, demonstrating that polymeric monolithic microbore columns constitute a potential alternative to packed columns for routine quality control of whey‐based dietary supplements.
- 26 June 2026
- Published by Wiley in Separation Science Plus
- Vol. 9 (7) , e70271
Polymeric Microbore Monolithic Column for the Fast Determination of Milk Whey Proteins in Powder Supplements by Reversed‐phase Liquid Chromatography
A rapid reversed‐phase liquid chromatographic method was developed for the separation and quantification of major whey proteins in dietary supplements using a poly(butyl methacrylate–co–ethylene dimethacrylate) monolithic column. The column structure was characterized by scanning electron microscopy, revealing a homogeneous porous network composed of ∼1 µm polymer globules and large flow‐through pores, which together provide high permeability and low backpressure, suitable for fast separations. Under a steep acetonitrile gradient, α‐lactalbumin (α‐LA), bovine serum albumin (BSA), and β‐lactoglobulin (β‐LG) were separated within 4 min, showing good peak symmetry and repeatable retention factors. The method exhibited excellent linearity ( R 2 > 0.99) over the concentration range of 0.025–0.91 mg/mL, with limits of detection ranging from 2.7 µg/mL for BSA to 6.2 µg/mL for β‐LG. Furthermore, analysis of three commercial whey protein supplements showed high intermediate precision (evaluated over three different days), with relative standard deviations below 6.0% for the major proteins (α‐LA and β‐LG) and under 12.5% for the minor component (BSA). Spike‐and‐recovery experiments confirmed the accuracy and reliability of the proposed method, yielding recovery rates ranging from 97% to 113%. β‐LG was the predominant protein, followed by α‐LA and minor amounts of BSA. The proposed approach provided fast analysis and low consumption of solvent and sample, with acceptable chromatographic efficiency, demonstrating that polymeric monolithic microbore columns constitute a potential alternative to packed columns for routine quality control of whey‐based dietary supplements.
- Open Access
- 19 February 2026
- Published by Elsevier in SSRN Electronic Journal
Polymeric microbore monolithic column for the fast determination of milk whey proteins in powder supplements by reversed-phase liquid chromatography
A rapid and reliable reversed-phase liquid chromatographic method using a poly(butyl methacrylate–co–ethylene dimethacrylate) monolithic column was developed for the separation and quantification of major whey proteins in dietary supplements. Scanning electron microscopy showed a homogeneous monolithic structure formed by ~1 μm polymer globules and large flow-through pores, providing high permeability and low backpressure for fast separations. α-Lactalbumin, bovine serum albumin, and β-lactoglobulin were baseline-separated within 4 min using a steep acetonitrile gradient, with good peak symmetry and highly reproducible retention factors. The method exhibited excellent linearity (R² > 0.99), low limits of detection (2.7–6.2 µg/mL), and satisfactory precision and accuracy, as demonstrated by repeatability and recovery studies (97–112%). Application to commercial supplements confirmed β-lactoglobulin as the predominant protein, followed by α-lactalbumin and minor bovine serum albumin. The approach combines high throughput, robustness, and quantitative reliability, representing an efficient alternative to packed-column RPLC for routine quality control of whey protein products.
- 19 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessPolymeric microbore monolithic column for the fast determination of milk whey proteins in powder supplements by reversed-phase liquid chromatography
A rapid and reliable reversed-phase liquid chromatographic method using a poly(butyl methacrylate–co–ethylene dimethacrylate) monolithic column was developed for the separation and quantification of major whey proteins in dietary supplements. Scanning electron microscopy showed a homogeneous monolithic structure formed by ~1 μm polymer globules and large flow-through pores, providing high permeability and low backpressure for fast separations. α-Lactalbumin, bovine serum albumin, and β-lactoglobulin were baseline-separated within 4 min using a steep acetonitrile gradient, with good peak symmetry and highly reproducible retention factors. The method exhibited excellent linearity (R² > 0.99), low limits of detection (2.7–6.2 µg/mL), and satisfactory precision and accuracy, as demonstrated by repeatability and recovery studies (97–112%). Application to commercial supplements confirmed β-lactoglobulin as the predominant protein, followed by α-lactalbumin and minor bovine serum albumin. The approach combines high throughput, robustness, and quantitative reliability, representing an efficient alternative to packed-column RPLC for routine quality control of whey protein products.
- 14 September 2025
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 109 (2) , 200-207
Evaluation of Spectrophotometric Flow Injection and Microwave-Induced Plasma Optical Emission Spectrometry Methods for the Quantification of Phosphorus in Fertilizers
Background: The growing need to increase the efficiency of routine analyses in the QC laboratories of agricultural fertilizer manufacturers underscores the importance of automating official methods or developing validated alternatives to enhance analytical throughput. Phosphorus, a key nutrient in fertilizers, demands precise and rapid analytical techniques that comply with current regulatory requirements. Objective: This study aimed to evaluate flow injection analysis (FIA) methods with molecular absorption spectrophotometric detection—based on official protocols—and compare them to a more advanced technique, microwave-induced plasma optical emission spectrometry (MIP-OES), for the quantification of elemental phosphorus. Methods: Three methodologies were assessed: molecular absorption spectrophotometry based on the formation of yellow vanadophosphomolybdate, the formation of molybdenum blue, and MIP-OES. These methods were applied to fertilizer samples extracted using water and neutral ammonium citrate (NAC), as prescribed by official procedures. Results: FIA methods provided a sampling throughput of up to 120 analyses/h, while MIP-OES enabled up to 240 analyses/h. Both spectrophotometric methods had LOQ near 1.0 mg/L. However, the yellow vanadophosphomolybdate method showed better linearity, up to 40 mg/L, compared to 20 mg/L for the molybdenum blue method. MIP-OES exhibited the highest sensitivity (LOQ <0.2 mg/L) and the broadest linear range. All methods showed acceptable accuracy and precision when tested with certified reference materials. Conclusion: FIA systems are advantageous over conventional methods due to their simplicity and low cost, making them suitable for routine laboratory settings. MIP-OES, while requiring greater instrumental investment, offers higher throughput and eliminates the need for reagent preparation. Highlights: Considering their respective strengths—FIA for accessibility and MIP-OES for performance—it is recommended that both methods are included as official methods of analysis by the Brazilian Ministry of Agriculture (MAPA) and other international regulatory bodies.
- 14 September 2025
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 109 (2) , 200-207
Evaluation of Spectrophotometric Flow Injection and Microwave-Induced Plasma Optical Emission Spectrometry Methods for the Quantification of Phosphorus in Fertilizers
Background: The growing need to increase the efficiency of routine analyses in the QC laboratories of agricultural fertilizer manufacturers underscores the importance of automating official methods or developing validated alternatives to enhance analytical throughput. Phosphorus, a key nutrient in fertilizers, demands precise and rapid analytical techniques that comply with current regulatory requirements. Objective: This study aimed to evaluate flow injection analysis (FIA) methods with molecular absorption spectrophotometric detection—based on official protocols—and compare them to a more advanced technique, microwave-induced plasma optical emission spectrometry (MIP-OES), for the quantification of elemental phosphorus. Methods: Three methodologies were assessed: molecular absorption spectrophotometry based on the formation of yellow vanadophosphomolybdate, the formation of molybdenum blue, and MIP-OES. These methods were applied to fertilizer samples extracted using water and neutral ammonium citrate (NAC), as prescribed by official procedures. Results: FIA methods provided a sampling throughput of up to 120 analyses/h, while MIP-OES enabled up to 240 analyses/h. Both spectrophotometric methods had LOQ near 1.0 mg/L. However, the yellow vanadophosphomolybdate method showed better linearity, up to 40 mg/L, compared to 20 mg/L for the molybdenum blue method. MIP-OES exhibited the highest sensitivity (LOQ <0.2 mg/L) and the broadest linear range. All methods showed acceptable accuracy and precision when tested with certified reference materials. Conclusion: FIA systems are advantageous over conventional methods due to their simplicity and low cost, making them suitable for routine laboratory settings. MIP-OES, while requiring greater instrumental investment, offers higher throughput and eliminates the need for reagent preparation. Highlights: Considering their respective strengths—FIA for accessibility and MIP-OES for performance—it is recommended that both methods are included as official methods of analysis by the Brazilian Ministry of Agriculture (MAPA) and other international regulatory bodies.
- 26 June 2025
- Published by Elsevier in Food Chemistry
- Vol. 492 (Pt 1) , 145306
Bentonite-modified glassy carbon electrode for the voltammetric determination of caffeine in beverages
- 26 June 2025
- Published by Elsevier in Food Chemistry
- Vol. 492 (Pt 1) , 145306
Bentonite-modified glassy carbon electrode for the voltammetric determination of caffeine in beverages
- Open Access
Adsorption of Caffeine and Demethylated Metabolites on Na+-Exchanged Bentonite
Clay minerals are promising candidates for caffeine removal due to their environmental friendliness and natural abundance. In this study, a commercially available bentonite was modified by Na+ exchange and characterized using Fourier transform infrared spectroscopy, X-ray diffractometry, scanning electron microscopy, zeta potential measurements, and specific surface area analysis. Caffeine adsorption was rapid, reaching equilibrium within 15 min. Adsorption isotherms for caffeine and its metabolites (theobromine, paraxanthine, and theophylline) in pure water were analyzed at 25.0 ± 0.5 °C using Langmuir and Freundlich models, both individually and in mixtures. Only caffeine exhibited favorable adsorption behavior, fitting the Langmuir equation, which allowed for the determination of a maximum adsorption capacity of 20 ± 3 mg/g, regardless of metabolite presence. The removal exceeded 85% of the caffeine from a 5.0 mg/L solution. The adsorption affinity of the studied compounds toward Na+-exchanged bentonite followed the order: caffeine >>> theobromine > paraxanthine ~ theophylline. The modified bentonite was then tested for caffeine removal from beverages and synthetic urine, achieving removal efficiencies exceeding 87%. To our knowledge, this is the first study investigating the effect of major caffeine metabolites on adsorption rates across different sample matrices, such as artificial urine, cola soda, soluble coffee, energy drinks, green tea, and yerba mate.
Open AccessAdsorption of Caffeine and Demethylated Metabolites on Na+-Exchanged Bentonite
Clay minerals are promising candidates for caffeine removal due to their environmental friendliness and natural abundance. In this study, a commercially available bentonite was modified by Na+ exchange and characterized using Fourier transform infrared spectroscopy, X-ray diffractometry, scanning electron microscopy, zeta potential measurements, and specific surface area analysis. Caffeine adsorption was rapid, reaching equilibrium within 15 min. Adsorption isotherms for caffeine and its metabolites (theobromine, paraxanthine, and theophylline) in pure water were analyzed at 25.0 ± 0.5 °C using Langmuir and Freundlich models, both individually and in mixtures. Only caffeine exhibited favorable adsorption behavior, fitting the Langmuir equation, which allowed for the determination of a maximum adsorption capacity of 20 ± 3 mg/g, regardless of metabolite presence. The removal exceeded 85% of the caffeine from a 5.0 mg/L solution. The adsorption affinity of the studied compounds toward Na+-exchanged bentonite followed the order: caffeine >>> theobromine > paraxanthine ~ theophylline. The modified bentonite was then tested for caffeine removal from beverages and synthetic urine, achieving removal efficiencies exceeding 87%. To our knowledge, this is the first study investigating the effect of major caffeine metabolites on adsorption rates across different sample matrices, such as artificial urine, cola soda, soluble coffee, energy drinks, green tea, and yerba mate.
- 24 June 2024
- Published by Wiley in Separation Science Plus
- Vol. 7 (8)
A Green Liquid Chromatography Method for Simultaneous Quantification of Caffeine and its Three Major Metabolites in Urine, Drinks, and Herbal Products
A green reversed‐phase liquid chromatography method was developed to determine caffeine (CF), theobromine (TB), theophylline (TP), and paraxanthine (PX). The stationary phase was a silica‐based C18 monolithic column (100 × 3.0 mm 2 i.d.), eluted with a gradient from 6% to 10% (v/v) of ethanol in water, at a flow rate of 0.75 mL/min (35°C) and UV detection at 272 nm. The compounds were separated in less than 6 min, with a total time of 10 min for column reconditioning. The effect of gradient composition, flow rate, injection volume, and column temperature was evaluated in the separation efficiency, especially regarding the critical pair PX/TP, for which the best resolution was 1.37. The linear range was between 0.5 and 100 µg/mL. The LODs were 0.065, 0.057, 0.040, and 0.044 mg/mL for TP, TB, PX, and CF, respectively. The method was applied to green tea and yerba mate infusions, soft drinks, energy drinks, and soluble coffee. Urine samples were analyzed before and after solid‐phase extraction. The accuracy was evaluated by the spiking/recovery strategy standing in the 79.6% to 116.4% range. The separation performance and the mobile phase consumption were compared to those of another method using a gradient of methanol in water.
- 24 June 2024
- Published by Wiley in Separation Science Plus
- Vol. 7 (8)
A Green Liquid Chromatography Method for Simultaneous Quantification of Caffeine and its Three Major Metabolites in Urine, Drinks, and Herbal Products
A green reversed‐phase liquid chromatography method was developed to determine caffeine (CF), theobromine (TB), theophylline (TP), and paraxanthine (PX). The stationary phase was a silica‐based C18 monolithic column (100 × 3.0 mm 2 i.d.), eluted with a gradient from 6% to 10% (v/v) of ethanol in water, at a flow rate of 0.75 mL/min (35°C) and UV detection at 272 nm. The compounds were separated in less than 6 min, with a total time of 10 min for column reconditioning. The effect of gradient composition, flow rate, injection volume, and column temperature was evaluated in the separation efficiency, especially regarding the critical pair PX/TP, for which the best resolution was 1.37. The linear range was between 0.5 and 100 µg/mL. The LODs were 0.065, 0.057, 0.040, and 0.044 mg/mL for TP, TB, PX, and CF, respectively. The method was applied to green tea and yerba mate infusions, soft drinks, energy drinks, and soluble coffee. Urine samples were analyzed before and after solid‐phase extraction. The accuracy was evaluated by the spiking/recovery strategy standing in the 79.6% to 116.4% range. The separation performance and the mobile phase consumption were compared to those of another method using a gradient of methanol in water.
- 26 December 2023
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1288, 342183
Porous polymer monolithic columns to investigate the interaction of humic substances with herbicides and emerging pollutants by affinity chromatography
- 26 December 2023
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1288, 342183
Porous polymer monolithic columns to investigate the interaction of humic substances with herbicides and emerging pollutants by affinity chromatography
- 3 July 2023
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part B
- Vol. 58 (7) , 539-553
Empirical adsorption kinetics: comparing linear and nonlinear regression analysis emphasizing the need for high throughput analysis
This paper evaluates linear and nonlinear regression analysis to describe the empirical adsorption kinetics using pseudo-first-order (PFO) and pseudo-second-order (PSO) models. These models have been used to characterize the performance of adsorbents for environmental remediation and environmental modeling. Data were simulated using the PFO and PSO models with 1, 2, and 5% noise levels and fitted by nonlinear and linearized PFO and PSO equations. Nonlinear regression analysis provided rate constants and adsorption capacities with better accuracy than linearization. Besides the correlation coefficient, Chi-square and residual plot analysis helped choose the proper model to describe the adsorbent efficiency and validate the results. Both models and the NLR fitting were employed to reevaluate data obtained in our research group, including the adsorption of Hg(II) on thiol-modified vermiculite, glyphosate on soils rich in aluminum and iron oxides, phosphate on Fe(III) polyhydroxy cations modified montmorillonite, and paraquat on soil and vermiculite. While fitting the simulated data indicates an unequivocal and correct kinetic model, fitting the experimental data is not straightforward, suggesting mixed models rule the adsorption and that a large number of data points, especially at the initial steps of adsorption, provided by high throughput analysis, help to improve the kinetic modeling.
- 3 July 2023
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part B
- Vol. 58 (7) , 539-553
Empirical adsorption kinetics: comparing linear and nonlinear regression analysis emphasizing the need for high throughput analysis
This paper evaluates linear and nonlinear regression analysis to describe the empirical adsorption kinetics using pseudo-first-order (PFO) and pseudo-second-order (PSO) models. These models have been used to characterize the performance of adsorbents for environmental remediation and environmental modeling. Data were simulated using the PFO and PSO models with 1, 2, and 5% noise levels and fitted by nonlinear and linearized PFO and PSO equations. Nonlinear regression analysis provided rate constants and adsorption capacities with better accuracy than linearization. Besides the correlation coefficient, Chi-square and residual plot analysis helped choose the proper model to describe the adsorbent efficiency and validate the results. Both models and the NLR fitting were employed to reevaluate data obtained in our research group, including the adsorption of Hg(II) on thiol-modified vermiculite, glyphosate on soils rich in aluminum and iron oxides, phosphate on Fe(III) polyhydroxy cations modified montmorillonite, and paraquat on soil and vermiculite. While fitting the simulated data indicates an unequivocal and correct kinetic model, fitting the experimental data is not straightforward, suggesting mixed models rule the adsorption and that a large number of data points, especially at the initial steps of adsorption, provided by high throughput analysis, help to improve the kinetic modeling.