Nan Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nan Xie has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Qifeng Xu
College of Electrical Engineering and Automation, Fuzhou University, Fuzhou, China
5 shared publications - Xiangyu Shen
School of Electrical Engineering and Automation, Fuzhou University, Fuzhou, China
3 shared publications - Zhichao He
School of Electrical Engineering and Automation, Fuzhou University, Fuzhou, China
3 shared publications Jun Li
College of Electrical Engineering and Automation Fuzhou University Fuzhou China
2 shared publicationsYifan Huang
College of Electrical Engineering and Automation, Fuzhou University, Fuzhou 350116, China
2 shared publicationsYifan Lin
College of Electrical Engineering and Automation Fuzhou University Fuzhou China
2 shared publications
Latest Publications
- Open Access
- 28 January 2026
- Published by MDPI AG in Electronics
- Vol. 15 (3) , 562
Elevator Travelling Cable’s Diagnostics Based on Deep Learning Fitting and Channel Attention
The ageing of elevator travelling cables results in the breakage of inner copper strands, leading to communication and control faults in the elevator system. In this paper, a travelling cable state evaluation method based on time-frequency transformation and a deep learning fitting method is proposed. The cable diagnosis is based on the transmission line theory and finite element simulation results, which indicate that the number of broken strands of copper wires in twisted cables is positively related to the amplitude of fluctuation in the cable’s transmission spectrum. To evaluate this fluctuation with low cost and high accuracy, we acquired the 500 Msps time-domain signal after a square wave with different periods was transmitted through the detected cable; the transmission in base frequency and harmonics is calculated and combined into the total transmission spectrum. A deep learning model with a two-layer 1-D CNN and squeeze-excitation channel attention is utilized to fit the spectrum data, and cross-entropy is applied to estimate the departure between the fitting results and the experimental data, which serves as the cable’s broken-state index. Experiments demonstrate that the proposed method is able to detect minor cable faults such as one or two copper strands broken and could distinguish different broken states with a sensitivity of 16.42 ± 1.39 per break strand.
- 28 January 2026
- Published by MDPI AG in Electronics
- Vol. 15 (3) , 562
Open AccessElevator Travelling Cable’s Diagnostics Based on Deep Learning Fitting and Channel Attention
The ageing of elevator travelling cables results in the breakage of inner copper strands, leading to communication and control faults in the elevator system. In this paper, a travelling cable state evaluation method based on time-frequency transformation and a deep learning fitting method is proposed. The cable diagnosis is based on the transmission line theory and finite element simulation results, which indicate that the number of broken strands of copper wires in twisted cables is positively related to the amplitude of fluctuation in the cable’s transmission spectrum. To evaluate this fluctuation with low cost and high accuracy, we acquired the 500 Msps time-domain signal after a square wave with different periods was transmitted through the detected cable; the transmission in base frequency and harmonics is calculated and combined into the total transmission spectrum. A deep learning model with a two-layer 1-D CNN and squeeze-excitation channel attention is utilized to fit the spectrum data, and cross-entropy is applied to estimate the departure between the fitting results and the experimental data, which serves as the cable’s broken-state index. Experiments demonstrate that the proposed method is able to detect minor cable faults such as one or two copper strands broken and could distinguish different broken states with a sensitivity of 16.42 ± 1.39 per break strand.
- Open Access
- 30 July 2025
- Published by IOP Publishing in Machine Learning: Engineering
- Vol. 1 (1) , 015001
Real-time detection of insulator defects based on improved wavelet scattering convolutional network
- 30 July 2025
- Published by IOP Publishing in Machine Learning: Engineering
- Vol. 1 (1) , 015001
Open AccessReal-time detection of insulator defects based on improved wavelet scattering convolutional network
- 17 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (5) , 2683-2695
Ultra-Low Power Electronic Current Transducer Based on 4-Level Encoding and Weak-Light Commutation
The power supply solutions for the high-voltage side of active electronic current transducers (ECTs) suffer from dead zones in low currents, low energy conversion efficiency and so on. This paper proposes an ECT with a power consumption less than 4 milliwatts (mW) on the high-voltage side, which employs a battery-powered scheme to solve the problems. This scheme utilizes Light-emitting Diodes (LEDs) operating in a weak light mode with 1.8 V driving voltage and effective duty cycle of 0.16. A low-power driver, composed of double half-bridge, is adopted to merge two digital signals into a single 4-level one, halving the power consumption of the LEDs. A 4-level anti-interference decoding method integrating support vector machine and recurrent neural network is employed in the low voltage side. The experimental results demonstrate that the power consumption on the high-voltage side of ECT has a maximum value of 3.14 mW, with accuracy class of 0.2 S. The combined algorithm can correctly decode all the 4-level experimental datasets, as well as the expanded dataset generated by autoencoder and generative adversarial networks. Furthermore, it also exhibits excellent generalization capabilities and resistance to noise interference.
- 17 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (5) , 2683-2695
Ultra-Low Power Electronic Current Transducer Based on 4-Level Encoding and Weak-Light Commutation
The power supply solutions for the high-voltage side of active electronic current transducers (ECTs) suffer from dead zones in low currents, low energy conversion efficiency and so on. This paper proposes an ECT with a power consumption less than 4 milliwatts (mW) on the high-voltage side, which employs a battery-powered scheme to solve the problems. This scheme utilizes Light-emitting Diodes (LEDs) operating in a weak light mode with 1.8 V driving voltage and effective duty cycle of 0.16. A low-power driver, composed of double half-bridge, is adopted to merge two digital signals into a single 4-level one, halving the power consumption of the LEDs. A 4-level anti-interference decoding method integrating support vector machine and recurrent neural network is employed in the low voltage side. The experimental results demonstrate that the power consumption on the high-voltage side of ECT has a maximum value of 3.14 mW, with accuracy class of 0.2 S. The combined algorithm can correctly decode all the 4-level experimental datasets, as well as the expanded dataset generated by autoencoder and generative adversarial networks. Furthermore, it also exhibits excellent generalization capabilities and resistance to noise interference.
- Open Access
Suppression and Regulation of Thermal Birefringence in Optical Voltage Sensor with Isomerism Electrodes and Arbitrary Electric Field Direction Modulation
The insufficient stability and reliability of Optical Voltage Sensor is primarily caused by thermal stress induced birefringence. In this paper, a method based on arbitrary electric field direction modulation and isomerism electrodes is proposed to suppress or regulate it. With the aid of multi-physics Finite Element Method, Jones Matrix and the theory of photoelastic effect, it is found that metal or transparent isomerism electrodes can generate a special thermal stress distribution, which regulates the birefringence in the optical path and their induced measurement error. The experiment is conducted on a 10mm cubic bismuth germanite crystal, with cutting directions 110, -110 and 001. The experiment result shows that Cu isomerism electrodes with electric field angle of 59.9 degrees could generate 37% less birefringence error compared to parallel plate electrodes, in the temperature range from 25 degrees Celsius to 40 degrees Celsius. However, the Indium Tin Oxide electrodes with field angle of 29.6 degrees produces approximately 7 times error because of its bad ductility and thermal conduction. The proposed modeling and suppression method for birefringence is beneficial to design of high accuracy optical voltage sensor or electro-optical modulator.
Open AccessSuppression and Regulation of Thermal Birefringence in Optical Voltage Sensor with Isomerism Electrodes and Arbitrary Electric Field Direction Modulation
The insufficient stability and reliability of Optical Voltage Sensor is primarily caused by thermal stress induced birefringence. In this paper, a method based on arbitrary electric field direction modulation and isomerism electrodes is proposed to suppress or regulate it. With the aid of multi-physics Finite Element Method, Jones Matrix and the theory of photoelastic effect, it is found that metal or transparent isomerism electrodes can generate a special thermal stress distribution, which regulates the birefringence in the optical path and their induced measurement error. The experiment is conducted on a 10mm cubic bismuth germanite crystal, with cutting directions 110, -110 and 001. The experiment result shows that Cu isomerism electrodes with electric field angle of 59.9 degrees could generate 37% less birefringence error compared to parallel plate electrodes, in the temperature range from 25 degrees Celsius to 40 degrees Celsius. However, the Indium Tin Oxide electrodes with field angle of 29.6 degrees produces approximately 7 times error because of its bad ductility and thermal conduction. The proposed modeling and suppression method for birefringence is beneficial to design of high accuracy optical voltage sensor or electro-optical modulator.
- Open Access
- 12 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Noncontact Three-phase Voltage Reconstruction with Dual-signal Input and Autoencoder model
The integral current signals obtained from metal sensors can reconstruct transmission line voltage. However, due to the approximate limitations of the integral current and the instability of the voltage-dividing capacitance measurement structure, the reconstructed signals suffer from waveform distortion, drift, and loss of high-frequency component information. To solve these problems, this paper proposes using both voltage signals and integral current signals as input. A 3D-printed structure simulates underground cables, accommodating up to nine copper foil sensors, shielded by aluminum foil. An autoencoder neural network with five-layer encoder and decoder, and a central layer of 800 neurons, learns the reconstruction function. The model training is facilitated by a home-made arbitrary three-phase high-voltage generator, which produces datasets of training three-phase voltages and sensor signals, and the three-phase voltages can be balanced or unbalanced sinusoidal waveforms or three-line voltage waveforms containing harmonics. Results show the model can reconstruct various three-phase waveforms with an error of less than 2.2%.
- 12 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessNoncontact Three-phase Voltage Reconstruction with Dual-signal Input and Autoencoder model
The integral current signals obtained from metal sensors can reconstruct transmission line voltage. However, due to the approximate limitations of the integral current and the instability of the voltage-dividing capacitance measurement structure, the reconstructed signals suffer from waveform distortion, drift, and loss of high-frequency component information. To solve these problems, this paper proposes using both voltage signals and integral current signals as input. A 3D-printed structure simulates underground cables, accommodating up to nine copper foil sensors, shielded by aluminum foil. An autoencoder neural network with five-layer encoder and decoder, and a central layer of 800 neurons, learns the reconstruction function. The model training is facilitated by a home-made arbitrary three-phase high-voltage generator, which produces datasets of training three-phase voltages and sensor signals, and the three-phase voltages can be balanced or unbalanced sinusoidal waveforms or three-line voltage waveforms containing harmonics. Results show the model can reconstruct various three-phase waveforms with an error of less than 2.2%.
- 17 July 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (10) , 105202
Half-wave voltage controllable optical voltage sensor with arbitrary electric field direction modulation*
An optical voltage sensor with an arbitrary electric field direction modulation (AEFDM) mode is proposed to increase the half-wave voltage. The mode is realized by heterogeneous electrodes arranged in a center-symmetric way, and generates an electric field with a direction at an arbitrary angle to the light propagation direction. The finite element method and coupling wave theory are used to design and optimize the electrodes and field distribution. The experimental results show that heterogeneous electrodes and AEFDM mode are able to regulate the sensor’s half-wave voltage in a range from 1 to 30 times (47–1409 kV), with 0.5 class accuracy and 99.99% linearity. This novel AEFDM method proposes a new electrode shape and position, reducing temperature drift to 50% compared to solid-state voltage divider method.
- 17 July 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (10) , 105202
Half-wave voltage controllable optical voltage sensor with arbitrary electric field direction modulation*
An optical voltage sensor with an arbitrary electric field direction modulation (AEFDM) mode is proposed to increase the half-wave voltage. The mode is realized by heterogeneous electrodes arranged in a center-symmetric way, and generates an electric field with a direction at an arbitrary angle to the light propagation direction. The finite element method and coupling wave theory are used to design and optimize the electrodes and field distribution. The experimental results show that heterogeneous electrodes and AEFDM mode are able to regulate the sensor’s half-wave voltage in a range from 1 to 30 times (47–1409 kV), with 0.5 class accuracy and 99.99% linearity. This novel AEFDM method proposes a new electrode shape and position, reducing temperature drift to 50% compared to solid-state voltage divider method.
- 19 May 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (8) , 085107
Linear phase delay detection method for optical voltage transformer based on S-wave plate
To achieve linear measurement of electro-optic phase delay and improve the accuracy and measurement range of the optical voltage transducer (OVT), this paper proposes a linear phase delay detection method for an optical voltage transformer based on a strip S-wave plate. Using the strip S-wave plate, the phase delay can be directly converted into the displacement of the dark stripe of the strip spot, and the displacement is located by the dual-quadrant detector. Using the Jones matrix, we confirm the linear relationship between the position of the dark stripe and the phase delay, and propose a positioning method and error compensation scheme of the dark stripe and set up an experimental system to verify its performance. The experimental results show that the OVT realizes the measurement of the electro-optic phase delay; the measuring range of the phase delay is up to ±40°, and the measurement error is less than 0.5%.
- 19 May 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (8) , 085107
Linear phase delay detection method for optical voltage transformer based on S-wave plate
To achieve linear measurement of electro-optic phase delay and improve the accuracy and measurement range of the optical voltage transducer (OVT), this paper proposes a linear phase delay detection method for an optical voltage transformer based on a strip S-wave plate. Using the strip S-wave plate, the phase delay can be directly converted into the displacement of the dark stripe of the strip spot, and the displacement is located by the dual-quadrant detector. Using the Jones matrix, we confirm the linear relationship between the position of the dark stripe and the phase delay, and propose a positioning method and error compensation scheme of the dark stripe and set up an experimental system to verify its performance. The experimental results show that the OVT realizes the measurement of the electro-optic phase delay; the measuring range of the phase delay is up to ±40°, and the measurement error is less than 0.5%.
- 5 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (6) , 7532-7540
A Linear Optical Current Transducer Implemented With a Strip Aluminum Polarization Grating
There are some significant defects in the existing optical current transducers (OCTs), such as optical power dependence, non-linear demodulation with Malus law, linear birefringence, etc. These defects severely hurt the reliability, stability, and accuracy of OCTs in long-term applications. The main idea to become free of these defects is to have a linear sense of the Faraday rotation angle. To this end, the paper presents a linear OCT based on a strip aluminum polarization grating, which directly converts the Faraday rotation angle into a synchronous line movement of a light spot. It then positions the spot to measure the current. It has no optical power dependence, realizes a linear sense of the Faraday rotation angle, reduces the effect of temperature drift, almost eliminates linear birefringence, improves long-term stability, and achieves a 0.2S class accuracy.
- 5 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (6) , 7532-7540
A Linear Optical Current Transducer Implemented With a Strip Aluminum Polarization Grating
There are some significant defects in the existing optical current transducers (OCTs), such as optical power dependence, non-linear demodulation with Malus law, linear birefringence, etc. These defects severely hurt the reliability, stability, and accuracy of OCTs in long-term applications. The main idea to become free of these defects is to have a linear sense of the Faraday rotation angle. To this end, the paper presents a linear OCT based on a strip aluminum polarization grating, which directly converts the Faraday rotation angle into a synchronous line movement of a light spot. It then positions the spot to measure the current. It has no optical power dependence, realizes a linear sense of the Faraday rotation angle, reduces the effect of temperature drift, almost eliminates linear birefringence, improves long-term stability, and achieves a 0.2S class accuracy.
- 19 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (21) , 9748-9754
Optimization of Electric Field Distributions in OVS With Hybrid Algorithm
The optimization of electric field distributions in the optical voltage sensor (OVS) are mostly based on the finite element calculations and the exhaustive search method. It is unable to map complicated and nonlinear relationships between the electric field distribution and the sensing structure. Moreover, these methods turn out to be time-consuming, inefficient, and easy to fall into local traps. A hybrid optimization algorithm based on PSO (Particle Swarm Optimization) and SVM (Support Vector Machine) is developed to fix these issues in which the PSO-SVM establishes an electric field model for the electro-optic crystal and then the model is modulated by the PSO to achieve optimization. The medium attaching structure is taken as an example to test and verify the job, and the simulations and experiments show that the uniformity of electric field distributions is improved by 58% and the training time is saved by 87%.
- 19 July 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (21) , 9748-9754
Optimization of Electric Field Distributions in OVS With Hybrid Algorithm
The optimization of electric field distributions in the optical voltage sensor (OVS) are mostly based on the finite element calculations and the exhaustive search method. It is unable to map complicated and nonlinear relationships between the electric field distribution and the sensing structure. Moreover, these methods turn out to be time-consuming, inefficient, and easy to fall into local traps. A hybrid optimization algorithm based on PSO (Particle Swarm Optimization) and SVM (Support Vector Machine) is developed to fix these issues in which the PSO-SVM establishes an electric field model for the electro-optic crystal and then the model is modulated by the PSO to achieve optimization. The medium attaching structure is taken as an example to test and verify the job, and the simulations and experiments show that the uniformity of electric field distributions is improved by 58% and the training time is saved by 87%.
- 6 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (17) , 7041-7046
A Linear Optical Current Transducer Based on Newton’s Ring Sub-Wavelength Grating
This paper presents a novel optical current transducer based on Newton's ring sub-wavelength grating. It converts the Faraday rotation angle into synchronized rotation of the spot image and locates the spot with a four-quadrant detector to achieve real-time linear measurement of the current. The Newton's ring grating is used instead of a radial grating as a polarization detection device so the extinction ratio is distributed uniformly in the radial directions and the polarization characteristics have no change with the radial direction, thereby a higher measurement accuracy has been achieved. The angle measurement range can reach ±40 degrees which breaks through the limitations of the intensity demodulation mode. The performance of the transducer has been verified by experiments and a 0.2 S class accuracy achieved with a linear measurement, no interference of optical power fluctuation, and minimized the effect of birefringence.
- 6 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 18 (17) , 7041-7046
A Linear Optical Current Transducer Based on Newton’s Ring Sub-Wavelength Grating
This paper presents a novel optical current transducer based on Newton's ring sub-wavelength grating. It converts the Faraday rotation angle into synchronized rotation of the spot image and locates the spot with a four-quadrant detector to achieve real-time linear measurement of the current. The Newton's ring grating is used instead of a radial grating as a polarization detection device so the extinction ratio is distributed uniformly in the radial directions and the polarization characteristics have no change with the radial direction, thereby a higher measurement accuracy has been achieved. The angle measurement range can reach ±40 degrees which breaks through the limitations of the intensity demodulation mode. The performance of the transducer has been verified by experiments and a 0.2 S class accuracy achieved with a linear measurement, no interference of optical power fluctuation, and minimized the effect of birefringence.