Tao Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tao Yang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Zhenzhen Wu
Department of Periodontology and Implantology, Stomatological Hospital, Southern Medical University, Guangzhou, China
2 shared publicationsAi Meng
School of Stomatology, Tianjin Medical University, China No.12, Qixiangtai Rd. Heping District, Tianjin 610041, China
1 shared publicationBinxin Xu
1 shared publicationHuanzhong Ji
Hospital of Stomatology, Guanghua School of Stomatology, Guangdong Provincial Key Laboratory of Stomatology, Sun Yat‐sen University Guangzhou China
1 shared publication- Jian Wang
State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, Sichuan, China
1 shared publication Jiaqian You
1 shared publication
Latest Publications
- 17 June 2026
- Published by Wiley in European Journal of Dental Education
Evaluating the Performance of GPT ‐4.0 in Generating and Refining Multiple‐Choice Questions for Dental Education
Purpose: The integration of large‐language models into medical education assessment holds transformative potential, yet rigorous evaluation of their capabilities in generating specialized examination content remains underexplored. This study aims to explore the performance of GPT‐4.0 in crafting multiple‐choice questions (MCQs) within the domain of oral and maxillofacial surgery (OMFS), benchmarking it against GPT‐3.5 and GPT‐4o, and evaluates its capacity to assess and revise defective items. Methods: 100 MCQs generated by GPT‐4.0 were evaluated on six aspects with 5‐point scales. Comparative analyses were conducted among ChatGPT 4.0, ChatGPT 3.5, and ChatGPT 4o. Additionally, 43 defective MCQs generated by GPTs were input into GPT‐4.0 to assess its capabilities in detecting and providing modification suggestions. Inter‐rater reliability between the two expert reviewers was assessed using Cohen's kappa coefficient. Results: GPT‐4.0 generated questions rapidly and efficiently, with 87% of them being of high quality. However, 6% required replacement due to issues such as interdisciplinary ambiguity, flawed distractors, or item duplication, while an additional 7% needed minor revisions before use. The comparative analysis highlighted GPT‐4.0's marked advantage over GPT‐3.5, which exhibited higher defect rates and disciplinary misalignments. Notably, GPT‐4.0's ability to detect and revise defective questions proved limited, excelling only in identifying duplicate items but faltering in recognizing disciplinary overlaps or erroneous answers. Conclusion: GPT‐4.0 proves to be a highly capable tool for generating high‐quality OMFS MCQs, outperforming both GPT‐3.5 and GPT‐4o. Nevertheless, its limited capacity to detect nuanced medical flaws and distinguish between closely related disciplines necessitates mandatory human expert oversight to ensure the accuracy and validity of medical assessments.
- 17 June 2026
- Published by Wiley in European Journal of Dental Education
Evaluating the Performance of GPT ‐4.0 in Generating and Refining Multiple‐Choice Questions for Dental Education
Purpose: The integration of large‐language models into medical education assessment holds transformative potential, yet rigorous evaluation of their capabilities in generating specialized examination content remains underexplored. This study aims to explore the performance of GPT‐4.0 in crafting multiple‐choice questions (MCQs) within the domain of oral and maxillofacial surgery (OMFS), benchmarking it against GPT‐3.5 and GPT‐4o, and evaluates its capacity to assess and revise defective items. Methods: 100 MCQs generated by GPT‐4.0 were evaluated on six aspects with 5‐point scales. Comparative analyses were conducted among ChatGPT 4.0, ChatGPT 3.5, and ChatGPT 4o. Additionally, 43 defective MCQs generated by GPTs were input into GPT‐4.0 to assess its capabilities in detecting and providing modification suggestions. Inter‐rater reliability between the two expert reviewers was assessed using Cohen's kappa coefficient. Results: GPT‐4.0 generated questions rapidly and efficiently, with 87% of them being of high quality. However, 6% required replacement due to issues such as interdisciplinary ambiguity, flawed distractors, or item duplication, while an additional 7% needed minor revisions before use. The comparative analysis highlighted GPT‐4.0's marked advantage over GPT‐3.5, which exhibited higher defect rates and disciplinary misalignments. Notably, GPT‐4.0's ability to detect and revise defective questions proved limited, excelling only in identifying duplicate items but faltering in recognizing disciplinary overlaps or erroneous answers. Conclusion: GPT‐4.0 proves to be a highly capable tool for generating high‐quality OMFS MCQs, outperforming both GPT‐3.5 and GPT‐4o. Nevertheless, its limited capacity to detect nuanced medical flaws and distinguish between closely related disciplines necessitates mandatory human expert oversight to ensure the accuracy and validity of medical assessments.
- 13 March 2026
- Published by Elsevier in Chinese Chemical Letters
- Vol. 38 (3)
Immunomodulatory and antioxidant tannic acid-modified concentrated growth factor dressings to enhance soft tissue regeneration
- 13 March 2026
- Published by Elsevier in Chinese Chemical Letters
- Vol. 38 (3)
Immunomodulatory and antioxidant tannic acid-modified concentrated growth factor dressings to enhance soft tissue regeneration
- Open Access
- 11 October 2021
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 9
A Rapid and Convenient Approach to Construct Porous Collagen Membranes via Bioskiving and Sonication-Feasible for Mineralization to Induce Bone Regeneration
Porous mineralized collagen membranes efficiently promote bone regeneration. To generate them, we need to fabricate collagen membranes that are porous. However, the current fabrication method is primarily based on a bottom-up strategy, with certain limitations, such as a long manufacturing process, collagen denaturation, and failure to control fibril orientation. Using a top-down approach, we explore a novel method for constructing porous collagen membranes via the combined application of bioskiving and sonication. Numerous collagen membranes with well-aligned fibril structures were rapidly fabricated by bioskiving and then sonicated at 30, 60, 90, and 120 W for 20 min. This treatment allowed us to study the effect of power intensity on the physicochemical traits of collagen membranes. Subsequently, the prepared collagen membranes were immersed in amorphous calcium phosphate to evaluate the feasibility of mineralization. Additionally, the bioactivities of the membranes were assessed using preosteoblast cells. Tuning the power intensity was shown to modulate fibril orientation, and the porous membrane without denatured collagen could be obtained by a 20-min sonication treatment at 90 W. The prepared collagen membrane could also be further mineralized to enhance osteogenesis. Overall, this study offers a rapid and convenient approach for fabricating porous collagen membranes via bioskiving and sonication.
- 11 October 2021
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 9
Open AccessA Rapid and Convenient Approach to Construct Porous Collagen Membranes via Bioskiving and Sonication-Feasible for Mineralization to Induce Bone Regeneration
Porous mineralized collagen membranes efficiently promote bone regeneration. To generate them, we need to fabricate collagen membranes that are porous. However, the current fabrication method is primarily based on a bottom-up strategy, with certain limitations, such as a long manufacturing process, collagen denaturation, and failure to control fibril orientation. Using a top-down approach, we explore a novel method for constructing porous collagen membranes via the combined application of bioskiving and sonication. Numerous collagen membranes with well-aligned fibril structures were rapidly fabricated by bioskiving and then sonicated at 30, 60, 90, and 120 W for 20 min. This treatment allowed us to study the effect of power intensity on the physicochemical traits of collagen membranes. Subsequently, the prepared collagen membranes were immersed in amorphous calcium phosphate to evaluate the feasibility of mineralization. Additionally, the bioactivities of the membranes were assessed using preosteoblast cells. Tuning the power intensity was shown to modulate fibril orientation, and the porous membrane without denatured collagen could be obtained by a 20-min sonication treatment at 90 W. The prepared collagen membrane could also be further mineralized to enhance osteogenesis. Overall, this study offers a rapid and convenient approach for fabricating porous collagen membranes via bioskiving and sonication.
- 1 July 2021
- Published by Quintessence Publishing in The International Journal of Prosthodontics
- Vol. 34 (4) , 451-457
The Influence of Autoclaving on Diamond Burs Fabricated via Different Methods
Purpose: To evaluate the influence of repetitive autoclaving on diamond burs fabricated via different methods. Materials and Methods: A total of 96 diamond burs were divided into 12 groups according to fabrication method (single-element electroplating, multi-element electroplating, or brazing) and number of times autoclaved (0, 5, 10, or 15). The surface characteristics and components of the diamond burs were examined using scanning electron microscopy (SEM) and x-ray photoelectron spectroscopy (XPS). The cutting efficiency of the diamond burs was tested with a constant-pressure cutting appliance. Results: Compared to the nonautoclaved group, the cutting efficiency of the multi-element and single-element electroplated diamond burs decreased significantly after autoclaving 5, 10, and 15 times (P < .05). The cutting efficiency of the brazed diamond burs started to decrease significantly after 10 cycles (P < .05). Cracks appeared on the surfaces of multi-element electroplated diamond burs after 10 and 15 cycles, but were absent in the single-element electroplated and brazed diamond burs. A reduction of nickel was detected in the multi-element electroplated and brazed diamond burs, but not in the single-element electroplated diamond burs. Conclusion: Repetitive autoclaving could reduce the cutting efficiency of diamond burs. The extent of the reduction was related to fabrication method and number of autoclaving times, suggesting that used diamond burs should be separately autoclaved to avoid shortening the life spans of unused ones.
- 1 July 2021
- Published by Quintessence Publishing in The International Journal of Prosthodontics
- Vol. 34 (4) , 451-457
The Influence of Autoclaving on Diamond Burs Fabricated via Different Methods
Purpose: To evaluate the influence of repetitive autoclaving on diamond burs fabricated via different methods. Materials and Methods: A total of 96 diamond burs were divided into 12 groups according to fabrication method (single-element electroplating, multi-element electroplating, or brazing) and number of times autoclaved (0, 5, 10, or 15). The surface characteristics and components of the diamond burs were examined using scanning electron microscopy (SEM) and x-ray photoelectron spectroscopy (XPS). The cutting efficiency of the diamond burs was tested with a constant-pressure cutting appliance. Results: Compared to the nonautoclaved group, the cutting efficiency of the multi-element and single-element electroplated diamond burs decreased significantly after autoclaving 5, 10, and 15 times (P < .05). The cutting efficiency of the brazed diamond burs started to decrease significantly after 10 cycles (P < .05). Cracks appeared on the surfaces of multi-element electroplated diamond burs after 10 and 15 cycles, but were absent in the single-element electroplated and brazed diamond burs. A reduction of nickel was detected in the multi-element electroplated and brazed diamond burs, but not in the single-element electroplated diamond burs. Conclusion: Repetitive autoclaving could reduce the cutting efficiency of diamond burs. The extent of the reduction was related to fabrication method and number of autoclaving times, suggesting that used diamond burs should be separately autoclaved to avoid shortening the life spans of unused ones.
- 1 August 2014
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 471 (1-2) , 157-165
Incorporation of cisplatin into PEG-wrapped ultrapurified large-inner-diameter MWCNTs for enhanced loading efficiency and release profile
- 1 August 2014
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 471 (1-2) , 157-165
Incorporation of cisplatin into PEG-wrapped ultrapurified large-inner-diameter MWCNTs for enhanced loading efficiency and release profile