Olga García-Menéndez
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Olga García-Menéndez has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Bruno José Ballesteros Navarro
Instituto Geológico y Minero de España (CN IGME–CSIC), 28003 Madrid, Spain
4 shared publications - Arianna Renau-Pruñonosa
Department of Botany and Geology, Faculty of Biological Sciences, University of Valencia, Burjassot, Spain
3 shared publications Ignacio Morell
Coastal Aquifers Research Group, Research Institute for Pesticides and Water, Universitat Jaume I, Avda. Sos Baynat s/n, 12071, Castellón, Spain
2 shared publicationsAlejandra Renau-Llorens
1 shared publicationArianna Renau-Pruñonosa
Coastal Aquifers Research Group, Research Institute for Pesticides and Water, Universitat Jaume I, Avda. Sos Baynat s/n, 12071, Castellón, Spain
1 shared publicationCarlos Camuñas Palencia
Ctr Nacl Inst Geol & Minero Espana, Dept Aguas & Cambio Global, C Rios Rosas 23, Madrid 28003, Spain
1 shared publication
Latest Publications
- Open Access
- 28 September 2026
- Published by Taylor & Francis in International Journal of River Basin Management
- p. 1-16
A method for assessing short- to mid-term groundwater status: application to the Duero River Basin
1 Increasing water demands for human activities and ecosystem preservation make effective water management essential to ensure adequate water availability, particularly for critical uses such as do...
- 28 September 2026
- Published by Taylor & Francis in International Journal of River Basin Management
- p. 1-16
Open AccessA method for assessing short- to mid-term groundwater status: application to the Duero River Basin
1 Increasing water demands for human activities and ecosystem preservation make effective water management essential to ensure adequate water availability, particularly for critical uses such as do...
- Open Access
- 30 September 2022
- Published by Instituto Geologico y Minero de Espana in BOLETÍN GEOLÓGICO Y MINERO
- Vol. 133 (3) , 7-26
Deep aquifers as strategic groundwater reservoir in Spain
The objective of this paper is to establish a definition of deep aquifers, develop a methodological proposal to help select them as strategic groundwater reserves and develop a first inventory of deep aquifers in peninsular Spain, organized by hydrographic districts. The basic premises followed to consider a permeable formation as a deep aquifer are: water table depth greater than 300 m in free aquifers or the top of the permeable formation in the case of confined aquifers. A deep aquifer is also considered to be the lower horizon of very thick aquifers (from 300 m), from which the most superficial horizon is used. The definition of the potentially favorable areas and the initial characterization is based on a compilation and synthesis of geological and hydrogeological information, structured in 5 large blocks: location and identification, geology, hydrogeology, current status and bibliography. For its evaluation, a flowchart has been proposed with the basic lines of the evaluation process. The relevant aspects for suitability would be: stratigraphy and structural geology, prior knowledge of the conceptual model and water renewal, quality, viability of exploitation, effects, final knowledge, and management and governance. The final result allows the aquifer to be classified into three categories: strategic groundwater reserve, punctual reserve or non-viable reserve. The inventory carried out encompasses a total of 64 deep aquifers located in 13 basin districts. Finally, as example, three deep aquifers are presented: Amblés Valley, Madrid detritic aquifer and El Maestrazgo.
- 30 September 2022
- Published by Instituto Geologico y Minero de Espana in BOLETÍN GEOLÓGICO Y MINERO
- Vol. 133 (3) , 7-26
Open AccessDeep aquifers as strategic groundwater reservoir in Spain
The objective of this paper is to establish a definition of deep aquifers, develop a methodological proposal to help select them as strategic groundwater reserves and develop a first inventory of deep aquifers in peninsular Spain, organized by hydrographic districts. The basic premises followed to consider a permeable formation as a deep aquifer are: water table depth greater than 300 m in free aquifers or the top of the permeable formation in the case of confined aquifers. A deep aquifer is also considered to be the lower horizon of very thick aquifers (from 300 m), from which the most superficial horizon is used. The definition of the potentially favorable areas and the initial characterization is based on a compilation and synthesis of geological and hydrogeological information, structured in 5 large blocks: location and identification, geology, hydrogeology, current status and bibliography. For its evaluation, a flowchart has been proposed with the basic lines of the evaluation process. The relevant aspects for suitability would be: stratigraphy and structural geology, prior knowledge of the conceptual model and water renewal, quality, viability of exploitation, effects, final knowledge, and management and governance. The final result allows the aquifer to be classified into three categories: strategic groundwater reserve, punctual reserve or non-viable reserve. The inventory carried out encompasses a total of 64 deep aquifers located in 13 basin districts. Finally, as example, three deep aquifers are presented: Amblés Valley, Madrid detritic aquifer and El Maestrazgo.
- Open Access
Identification of Aquifer Recharge Sources as the Origin of Emerging Contaminants in Intensive Agricultural Areas. La Plana de Castellón, Spain
In urban, industrial, and agricultural areas, a vast array of contaminants may be found because they are introduced into the aquifers by different recharge sources. The emerging contaminants (ECs) correspond to unregulated contaminants, which may be candidates for future regulation depending on the results of research into their potential effects on health and on monitoring data regarding their occurrence. ECs frequently found in wastewater, such as acetaminophen, carbamazepine, primidone, and sulfamethoxazole, may be good indicators of the introduction of the reclaimed water to the aquifers. The resistance of the ECs to removal in wastewater treatment plants (WWTPs) causes them to be appropriate sewage markers. Plana de Castellón (Spain) is a coastal area that has been characterized by intensive citrus agriculture since the 1970s. Traditionally, in the southern sector of Plana de Castellón, 100% of irrigation water comes from groundwater. In recent years, local farmers have been using a mixture of groundwater and reclaimed water from wastewater treatment plants (WWTPs) to irrigate the citrus. The aims of the present study were: (i) to assess the occurrences, spatial distributions, and concentrations of selected ECs, including 32 antibiotics, 8 UV filters, and 2 nonsteroidal anti-inflammatory drugs, in groundwater in a common agricultural context; (ii) to identify the recharge (pollution) sources acting as the origin of the ECs, and (iii) to suggest ECs as indicators of reclaimed water arrival in detrital heterogeneous aquifers. The obtained data provided relevant information for the management of water resources and elucidated the fate and behavior of emerging contaminants in similar contexts.
Open AccessIdentification of Aquifer Recharge Sources as the Origin of Emerging Contaminants in Intensive Agricultural Areas. La Plana de Castellón, Spain
In urban, industrial, and agricultural areas, a vast array of contaminants may be found because they are introduced into the aquifers by different recharge sources. The emerging contaminants (ECs) correspond to unregulated contaminants, which may be candidates for future regulation depending on the results of research into their potential effects on health and on monitoring data regarding their occurrence. ECs frequently found in wastewater, such as acetaminophen, carbamazepine, primidone, and sulfamethoxazole, may be good indicators of the introduction of the reclaimed water to the aquifers. The resistance of the ECs to removal in wastewater treatment plants (WWTPs) causes them to be appropriate sewage markers. Plana de Castellón (Spain) is a coastal area that has been characterized by intensive citrus agriculture since the 1970s. Traditionally, in the southern sector of Plana de Castellón, 100% of irrigation water comes from groundwater. In recent years, local farmers have been using a mixture of groundwater and reclaimed water from wastewater treatment plants (WWTPs) to irrigate the citrus. The aims of the present study were: (i) to assess the occurrences, spatial distributions, and concentrations of selected ECs, including 32 antibiotics, 8 UV filters, and 2 nonsteroidal anti-inflammatory drugs, in groundwater in a common agricultural context; (ii) to identify the recharge (pollution) sources acting as the origin of the ECs, and (iii) to suggest ECs as indicators of reclaimed water arrival in detrital heterogeneous aquifers. The obtained data provided relevant information for the management of water resources and elucidated the fate and behavior of emerging contaminants in similar contexts.
- Open Access
- 3 August 2018
- Published by Universitat Jaume I
Evaluación multiparamétrica de un esquema MAR (Managed Aquifer Recharge) en un acuífero costero salinizado (Plana de Castellón, España)
- 3 August 2018
- Published by Universitat Jaume I
Open AccessEvaluación multiparamétrica de un esquema MAR (Managed Aquifer Recharge) en un acuífero costero salinizado (Plana de Castellón, España)
- 27 January 2018
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 190 (2) , 100
Using electrical resistivity tomography to assess the effectiveness of managed aquifer recharge in a salinized coastal aquifer
Over 40 years, the detrital aquifer of the Plana de Castellón (Spanish Mediterranean coast) has been subjected to seawater intrusion because of long dry periods combined with intensive groundwater exploitation. Against this backdrop, a managed artificial recharge (MAR) scheme was implemented to improve the groundwater quality. The large difference between the electrical conductivity (EC) of the ambient groundwater (brackish water due to marine intrusion) and the recharge water (freshwater) meant that there was a strong contrast between the resistivities of the brackish water saturated zone and the freshwater saturated zone. Electrical resistivity tomography (ERT) can be used for surveying similar settings to evaluate the effectiveness of artificial recharge schemes. By integrating geophysical data with lithological information, EC logs from boreholes, and hydrochemical data, we can interpret electrical resistivity (ER) with groundwater EC values and so identify freshwater saturated zones. Using this approach, ERT images provided a high-resolution spatial characterization and an accurate picture of the shape and extent of the recharge plume of the MAR site. After 5 months of injection, a freshwater plume with an EC of 400–600 μS/cm had formed that extended 400 m in the W-E direction, 250 m in the N-S direction, and to a depth of 40 m below piezometric level. This study also provides correlations between ER values with different lithologies and groundwater EC values that can be used to support other studies.
- 27 January 2018
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 190 (2) , 100
Using electrical resistivity tomography to assess the effectiveness of managed aquifer recharge in a salinized coastal aquifer
Over 40 years, the detrital aquifer of the Plana de Castellón (Spanish Mediterranean coast) has been subjected to seawater intrusion because of long dry periods combined with intensive groundwater exploitation. Against this backdrop, a managed artificial recharge (MAR) scheme was implemented to improve the groundwater quality. The large difference between the electrical conductivity (EC) of the ambient groundwater (brackish water due to marine intrusion) and the recharge water (freshwater) meant that there was a strong contrast between the resistivities of the brackish water saturated zone and the freshwater saturated zone. Electrical resistivity tomography (ERT) can be used for surveying similar settings to evaluate the effectiveness of artificial recharge schemes. By integrating geophysical data with lithological information, EC logs from boreholes, and hydrochemical data, we can interpret electrical resistivity (ER) with groundwater EC values and so identify freshwater saturated zones. Using this approach, ERT images provided a high-resolution spatial characterization and an accurate picture of the shape and extent of the recharge plume of the MAR site. After 5 months of injection, a freshwater plume with an EC of 400–600 μS/cm had formed that extended 400 m in the W-E direction, 250 m in the N-S direction, and to a depth of 40 m below piezometric level. This study also provides correlations between ER values with different lithologies and groundwater EC values that can be used to support other studies.
- 13 July 2016
- Published by Springer Nature in Water Resources Management
- Vol. 30 (13) , 4513-4527
A Standardized Index for Assessing Seawater Intrusion in Coastal Aquifers: The SITE Index
- 13 July 2016
- Published by Springer Nature in Water Resources Management
- Vol. 30 (13) , 4513-4527
A Standardized Index for Assessing Seawater Intrusion in Coastal Aquifers: The SITE Index
- Open Access
- 25 April 2016
- Published by Springer Nature in Environmental Earth Sciences
- Vol. 75 (9) , 1-18
Spatial characterization of the seawater upconing process in a coastal Mediterranean aquifer (Plana de Castellón, Spain): evolution and controls
- 25 April 2016
- Published by Springer Nature in Environmental Earth Sciences
- Vol. 75 (9) , 1-18
Open AccessSpatial characterization of the seawater upconing process in a coastal Mediterranean aquifer (Plana de Castellón, Spain): evolution and controls