Robert J. McDonald
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Robert J. McDonald has a total of 97 co-authors. Here are the top co-authors by number of shared publications:
David F. Kallmes
From the Departments of Radiology (R.J.M., J.S.M., D.D., D.S., R.K., L.J.E., D.F.K.), Laboratory Medicine and Pathology (M.E.J., D.L.M.), and Neurosurgery (D.F.K.), College of Medicine, Mayo Clinic, 200 1st St SW, Rochester, MN 55905
8 shared publications- David F. Kallmes
Department of Radiology, Mayo Clinic, 200 First St SW, Rochester, MN 55905
7 shared publications - Jennifer S. McDonald
Department of Radiology, Mayo Clinic, Rochester, Minnesota
6 shared publications Jennifer S. McDonald
From the Departments of Radiology (R.J.M., J.S.M., D.D., D.S., R.K., L.J.E., D.F.K.), Laboratory Medicine and Pathology (M.E.J., D.L.M.), and Neurosurgery (D.F.K.), College of Medicine, Mayo Clinic, 200 1st St SW, Rochester, MN 55905
5 shared publicationsD.F. Kallmes
Department of Radiology (R.J.M., J.S.M., D.F.K., H.J.C.)
3 shared publicationsH.J. Cloft
Department of Radiology (R.J.M., J.S.M., D.F.K., H.J.C.)
3 shared publications
Latest Publications
- 1 August 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (4) , e260067
First-in-Human Safety and Feasibility of Nodal and Pedal MR Lymphangiography with Gadopiclenol
Dynamic gadopiclenol-enhanced nodal and pedal MR lymphangiography was safe, with no adverse events, and feasible for imaging peripheral and central conducting lymphatic anatomy.
- 1 August 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (4) , e260067
First-in-Human Safety and Feasibility of Nodal and Pedal MR Lymphangiography with Gadopiclenol
Dynamic gadopiclenol-enhanced nodal and pedal MR lymphangiography was safe, with no adverse events, and feasible for imaging peripheral and central conducting lymphatic anatomy.
- 20 November 2025
- Published by Elsevier in Annals of Allergy, Asthma & Immunology
- Vol. 136 (3) , 308-314.e1
Biphasic, refractory, and life-threatening anaphylactic reactions to iodinated contrast media
- 20 November 2025
- Published by Elsevier in Annals of Allergy, Asthma & Immunology
- Vol. 136 (3) , 308-314.e1
Biphasic, refractory, and life-threatening anaphylactic reactions to iodinated contrast media
- 20 February 2025
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (9) , 1925-1930
Evaluation of Spontaneous Intracranial Hypotension Probabilistic Brain MRI Scoring Systems in Normal Patients
BACKGROUND AND PURPOSE: Probabilistic brain MRI scoring systems have been introduced to stratify the likelihood of identifying a CSF leak at myelography in spontaneous intracranial hypotension (SIH). The Bern scoring system by Dobrocky et al. is now well recognized, with a scoring system by Benson et al. introduced more recently (referred to as the “Mayo” score in this study). Neither of these scoring systems have been thoroughly evaluated in patients without SIH. The goal of this study was to evaluate these scoring systems in patients without SIH to understand the specificity of these MRI findings. MATERIALS AND METHODS: We retrospectively reviewed normal brain MRIs performed in patients without clinically suspected SIH. Each examination was reviewed by one of four board-certified neuroradiologists with extensive experience in SIH, and all criteria of both scoring systems were evaluated and recorded. RESULTS: 90 patients were included. Bern score was low probability in 78% and intermediate probability in 22%. Mayo score was low probability in 100%. Relatively high rates of positivity were seen in three specific Bern score parameters, including prepontine cistern effacement 5.0 mm or less (53%), decreased mammilopontine distance 6.5 mm or less (40%), and suprasellar cistern effacement 4.0 mm or less (28%). All intermediate probability Bern scores were due to suprasellar cistern effacement plus either or both prepontine cistern effacement and decreased mammilopontine distance. All other parameters of both scoring systems were either never or very rarely positive. CONCLUSIONS: All intermediate probability Bern scores were due to decreased CSF cistern measurements, which had relatively high positivity rates in our non-SIH patient cohort. Due to substantial overlap with normals, these measurements are not specific indicators of “brain sag”, a hallmark imaging finding for SIH, and are not specific for SIH when the only “positive” brain MRI finding(s). The Mayo score is likely more specific for SIH with low probability scores in all patients in our cohort. ABBREVIATIONS: SIH, spontaneous intracranial hypotension; DSM, digital subtraction myelography; CTM, CT myelography; PC-CTM, photon counting CT myelography; CVF, CSF-venous fistula; ICC, intraclass correlation coefficient.
- 20 February 2025
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (9) , 1925-1930
Evaluation of Spontaneous Intracranial Hypotension Probabilistic Brain MRI Scoring Systems in Normal Patients
BACKGROUND AND PURPOSE: Probabilistic brain MRI scoring systems have been introduced to stratify the likelihood of identifying a CSF leak at myelography in spontaneous intracranial hypotension (SIH). The Bern scoring system by Dobrocky et al. is now well recognized, with a scoring system by Benson et al. introduced more recently (referred to as the “Mayo” score in this study). Neither of these scoring systems have been thoroughly evaluated in patients without SIH. The goal of this study was to evaluate these scoring systems in patients without SIH to understand the specificity of these MRI findings. MATERIALS AND METHODS: We retrospectively reviewed normal brain MRIs performed in patients without clinically suspected SIH. Each examination was reviewed by one of four board-certified neuroradiologists with extensive experience in SIH, and all criteria of both scoring systems were evaluated and recorded. RESULTS: 90 patients were included. Bern score was low probability in 78% and intermediate probability in 22%. Mayo score was low probability in 100%. Relatively high rates of positivity were seen in three specific Bern score parameters, including prepontine cistern effacement 5.0 mm or less (53%), decreased mammilopontine distance 6.5 mm or less (40%), and suprasellar cistern effacement 4.0 mm or less (28%). All intermediate probability Bern scores were due to suprasellar cistern effacement plus either or both prepontine cistern effacement and decreased mammilopontine distance. All other parameters of both scoring systems were either never or very rarely positive. CONCLUSIONS: All intermediate probability Bern scores were due to decreased CSF cistern measurements, which had relatively high positivity rates in our non-SIH patient cohort. Due to substantial overlap with normals, these measurements are not specific indicators of “brain sag”, a hallmark imaging finding for SIH, and are not specific for SIH when the only “positive” brain MRI finding(s). The Mayo score is likely more specific for SIH with low probability scores in all patients in our cohort. ABBREVIATIONS: SIH, spontaneous intracranial hypotension; DSM, digital subtraction myelography; CTM, CT myelography; PC-CTM, photon counting CT myelography; CVF, CSF-venous fistula; ICC, intraclass correlation coefficient.
- 1 July 2024
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 223 (1)
Risk of Acute Kidney Injury Following IV Iodinated Contrast Media Exposure: 2023 Update, From the AJR Special Series on Contrast Media
Iodinated contrast material (ICM) has revolutionized the field of diagnostic radiology through improvements in diagnostic performance and expansion in clinical indications for radiographic and CT examinations. Historically, nephrotoxicity was a feared complication of ICM use, thought to be associated with a significant risk of morbidity and mortality. Such fears often precluded use of ICM in imaging evaluations, commonly at the expense of diagnostic performance and timely diagnosis. Over the past 20 years, the nephrotoxic risk of ICM has become a topic of debate, as more recent evidence from higher-quality studies now suggest that many cases of what was considered contrast-induced acute kidney injury (CI-AKI) were likely cases of mistaken causal attribution; most of these cases represented either acute kidney injury (AKI) caused by any of myriad other known factors that can adversely affect renal function and were coincidentally present at the time of contrast media exposure (contrast-associated AKI (CA-AKI)) or a manifestation of the normal variation in renal function that increases with worsening renal function. This review discusses the current state of knowledge on CI-AKI and CA-AKI including the incidence, risk factors, outcomes, and prophylactic strategies in the identification and management of these clinical conditions.
- 1 July 2024
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 223 (1)
Risk of Acute Kidney Injury Following IV Iodinated Contrast Media Exposure: 2023 Update, From the AJR Special Series on Contrast Media
Iodinated contrast material (ICM) has revolutionized the field of diagnostic radiology through improvements in diagnostic performance and expansion in clinical indications for radiographic and CT examinations. Historically, nephrotoxicity was a feared complication of ICM use, thought to be associated with a significant risk of morbidity and mortality. Such fears often precluded use of ICM in imaging evaluations, commonly at the expense of diagnostic performance and timely diagnosis. Over the past 20 years, the nephrotoxic risk of ICM has become a topic of debate, as more recent evidence from higher-quality studies now suggest that many cases of what was considered contrast-induced acute kidney injury (CI-AKI) were likely cases of mistaken causal attribution; most of these cases represented either acute kidney injury (AKI) caused by any of myriad other known factors that can adversely affect renal function and were coincidentally present at the time of contrast media exposure (contrast-associated AKI (CA-AKI)) or a manifestation of the normal variation in renal function that increases with worsening renal function. This review discusses the current state of knowledge on CI-AKI and CA-AKI including the incidence, risk factors, outcomes, and prophylactic strategies in the identification and management of these clinical conditions.
- 1 January 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 302 (2) , 270-273
Symptoms Associated with Gadolinium Exposure (SAGE): A Suggested Term
The American College of Radiology Committee on Drugs and Contrast Media proposes new nomenclature for Symptoms Associated with Gadolinium Exposure, or SAGE. The purpose is to assist researchers and... In this article, members of the American College of Radiology Committee on Drugs and Contrast Media propose a new term for symptoms reported after intravascular exposure to gadolinium-based contras...
- 1 January 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 302 (2) , 270-273
Symptoms Associated with Gadolinium Exposure (SAGE): A Suggested Term
The American College of Radiology Committee on Drugs and Contrast Media proposes new nomenclature for Symptoms Associated with Gadolinium Exposure, or SAGE. The purpose is to assist researchers and... In this article, members of the American College of Radiology Committee on Drugs and Contrast Media propose a new term for symptoms reported after intravascular exposure to gadolinium-based contras...
- 21 December 2021
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 302 (3) , 676-683
Neurologic Effects of Gadolinium Retention in the Brain after Gadolinium-based Contrast Agent Administration
There was no evidence of differences in clinical or histopathologic neurotoxicity parameters between rats exposed to supradiagnostic human dose equivalents of commercially available gadolinium-base... Background Concerns over the neurotoxic potential of retained gadolinium in brain tissues after intravenous gadolinium-based contrast agent (GBCA) administration have led to pronounced worldwide us...
- 21 December 2021
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 302 (3) , 676-683
Neurologic Effects of Gadolinium Retention in the Brain after Gadolinium-based Contrast Agent Administration
There was no evidence of differences in clinical or histopathologic neurotoxicity parameters between rats exposed to supradiagnostic human dose equivalents of commercially available gadolinium-base... Background Concerns over the neurotoxic potential of retained gadolinium in brain tissues after intravenous gadolinium-based contrast agent (GBCA) administration have led to pronounced worldwide us...
- 1 October 2021
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 301 (1) , 133-140
Prevention of Allergic-like Reactions at Repeat CT: Steroid Pretreatment versus Contrast Material Substitution
The study findings do not support the efficacy of steroid premedication (oral methylprednisolone at 12 and 2 hours) for preventing repeat allergic-like reactions in high-risk patients. Background It is unclear whether steroid premedication is an effective means of preventing repeat allergic-like reactions in high-risk patients with a previous allergic-like reaction to iodinated c...
- 1 October 2021
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 301 (1) , 133-140
Prevention of Allergic-like Reactions at Repeat CT: Steroid Pretreatment versus Contrast Material Substitution
The study findings do not support the efficacy of steroid premedication (oral methylprednisolone at 12 and 2 hours) for preventing repeat allergic-like reactions in high-risk patients. Background It is unclear whether steroid premedication is an effective means of preventing repeat allergic-like reactions in high-risk patients with a previous allergic-like reaction to iodinated c...
- 1 July 2020
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 296 (1) , 131-133
Signal Intensity Changes at MRI Following GBCA Exposure: Incidental Finding or Cause for Concern?
- 1 July 2020
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 296 (1) , 131-133
Signal Intensity Changes at MRI Following GBCA Exposure: Incidental Finding or Cause for Concern?
- 1 November 2017
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 285 (2) , 536-545
Comparison of Gadolinium Concentrations within Multiple Rat Organs after Intravenous Administration of Linear versus Macrocyclic Gadolinium Chelates
Intravenous administration of high doses of gadolinium-based contrast agents (GBCAs) is associated with extensive multiorgan deposition that is reduced but not eliminated by use of macrocyclic GBCA chelates in lieu of linear chelates. Purpose To compare gadolinium tissue concentrations of multiple linear and macrocyclic chelates in a rat model to better understand the scope and extent of tissue deposition following multiple intravenous doses of gadolinium-based contrast agent (GBCA). Materials and Methods In this Institutional Animal Care and Use Committee-approved study, healthy rats received 20 intravenous injections of 2.5 mmol gadolinium per kilogram (gadolinium-exposed group) or saline (control group) over a 26-day period. Unenhanced T1 signal intensities of the dentate nucleus were measured from magnetic resonance (MR) images obtained prior to GBCA injection and 3 days after final injection. Rat brain and renal, hepatic, and splenic tissues were harvested 7 days after final injection and subjected to inductively coupled plasma mass spectrometry and transmission electron microscopy for quantification and characterization of gadolinium deposits. Results Gadolinium deposition in brain tissue significantly varied with GBCA type (F = ...
- 1 November 2017
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 285 (2) , 536-545
Comparison of Gadolinium Concentrations within Multiple Rat Organs after Intravenous Administration of Linear versus Macrocyclic Gadolinium Chelates
Intravenous administration of high doses of gadolinium-based contrast agents (GBCAs) is associated with extensive multiorgan deposition that is reduced but not eliminated by use of macrocyclic GBCA chelates in lieu of linear chelates. Purpose To compare gadolinium tissue concentrations of multiple linear and macrocyclic chelates in a rat model to better understand the scope and extent of tissue deposition following multiple intravenous doses of gadolinium-based contrast agent (GBCA). Materials and Methods In this Institutional Animal Care and Use Committee-approved study, healthy rats received 20 intravenous injections of 2.5 mmol gadolinium per kilogram (gadolinium-exposed group) or saline (control group) over a 26-day period. Unenhanced T1 signal intensities of the dentate nucleus were measured from magnetic resonance (MR) images obtained prior to GBCA injection and 3 days after final injection. Rat brain and renal, hepatic, and splenic tissues were harvested 7 days after final injection and subjected to inductively coupled plasma mass spectrometry and transmission electron microscopy for quantification and characterization of gadolinium deposits. Results Gadolinium deposition in brain tissue significantly varied with GBCA type (F = ...
- Top Cited Papers
- 1 November 2017
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 285 (2) , 546-554
Gadolinium Deposition in Human Brain Tissues after Contrast-enhanced MR Imaging in Adult Patients without Intracranial Abnormalities
Our findings demonstrate that gadolinium deposition in neuronal tissues occurs even in the absence of intracranial abnormalities among patients exposed to multiple gadolinium-enhanced MR examinations. Purpose To determine whether gadolinium deposits in neural tissues of patients with intracranial abnormalities following intravenous gadolinium-based contrast agent (GBCA) exposure might be related to blood-brain barrier integrity by studying adult patients with normal brain pathologic characteristics. Materials and Methods After obtaining antemortem consent and institutional review board approval, the authors compared postmortem neuronal tissue samples from five patients who had undergone four to 18 gadolinium-enhanced magnetic resonance (MR) examinations between 2005 and 2014 (contrast group) with samples from 10 gadolinium-naive patients who had undergone at least one MR examination during their lifetime (control group). All patients in the contrast group had received gadodiamide. Neuronal tissues from the dentate nuclei, pons, globus pallidus, and thalamus were harvested and analyzed with inductively coupled plasma mass spectrometry (ICP-MS), transmission electron microscopy with energy-dispersive x-r...
- 1 November 2017
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 285 (2) , 546-554
Top Cited PapersGadolinium Deposition in Human Brain Tissues after Contrast-enhanced MR Imaging in Adult Patients without Intracranial Abnormalities
Our findings demonstrate that gadolinium deposition in neuronal tissues occurs even in the absence of intracranial abnormalities among patients exposed to multiple gadolinium-enhanced MR examinations. Purpose To determine whether gadolinium deposits in neural tissues of patients with intracranial abnormalities following intravenous gadolinium-based contrast agent (GBCA) exposure might be related to blood-brain barrier integrity by studying adult patients with normal brain pathologic characteristics. Materials and Methods After obtaining antemortem consent and institutional review board approval, the authors compared postmortem neuronal tissue samples from five patients who had undergone four to 18 gadolinium-enhanced magnetic resonance (MR) examinations between 2005 and 2014 (contrast group) with samples from 10 gadolinium-naive patients who had undergone at least one MR examination during their lifetime (control group). All patients in the contrast group had received gadodiamide. Neuronal tissues from the dentate nuclei, pons, globus pallidus, and thalamus were harvested and analyzed with inductively coupled plasma mass spectrometry (ICP-MS), transmission electron microscopy with energy-dispersive x-r...