Selda Sherifova
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Selda Sherifova has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Gerhard A. Holzapfel
Institute of Biomechanics, Graz University of Technology, Graz, Austria
7 shared publications - Boyce E. Griffith
Department of Mathematics, University of North Carolina, Chapel Hill, NC, USA
2 shared publications Gerhard Sommer
Institute of Biomechanics, Graz University of Technology, Stremayrgasse 16-II, Graz 8010, Austria
2 shared publications- Gerhard Sommer
Institute of Biomechanics, Graz University of Technology, Austria
2 shared publications Abe DeAnda
Division of Cardiothoracic Surgery, University of Texas Medical Branch, Galveston, TX, USA
1 shared publication- Alexey Kamenskiy
Department of Biomechanics, University of Nebraska Omaha, Omaha, NE, USA
1 shared publication
Latest Publications
- Open Access
- 12 August 2023
- Published by Elsevier in Acta Biomaterialia
- Vol. 169, 107-117
Regional biomechanical characterization of human ascending aortic aneurysms: Microstructure and biaxial mechanical response
- 12 August 2023
- Published by Elsevier in Acta Biomaterialia
- Vol. 169, 107-117
Open AccessRegional biomechanical characterization of human ascending aortic aneurysms: Microstructure and biaxial mechanical response
- Open Access
- 3 December 2020
- Published by Elsevier in Acta Biomaterialia
- Vol. 121, 461-474
Constitutive modeling using structural information on collagen fiber direction and dispersion in human superficial femoral artery specimens of different ages
- 3 December 2020
- Published by Elsevier in Acta Biomaterialia
- Vol. 121, 461-474
Open AccessConstitutive modeling using structural information on collagen fiber direction and dispersion in human superficial femoral artery specimens of different ages
- 1 July 2020
- Published by IOP Publishing in Progress in Biomedical Engineering
- Vol. 2 (3) , 032002
Biochemomechanics of the thoracic aorta in health and disease
Aneurysms and dissections of the thoracic aorta are life threatening events with poorly understood pathophysiologies which may have genetic origins. By starting with an introduction to these pathologies, we focus on the biochemomechanics of the healthy thoracic aorta. Specifically, we describe the microstructure and the mechanics of the aortic tissue since it is known that the microstructure strongly influences the biomechanical behavior. This relationship is then complemented by providing more detailed information on the selected extracellular matrix components (collagen, elastic fibers and proteoglycans) and smooth muscle cells. More specifically, we introduce the roles smooth muscle cells play in the function of the aortic wall: actively (mechanically) with their contractile abilities and passively by regulating the composition of the extracellular matrix they are embedded in, in particular via the transforming growth factor β (TGF-β) pathway. Subsequently, we summarize the microstructural changes in thoracic aortic aneurysms and dissections in connection with selected risk factors and genetic mutations, and couple these changes with the findings on the biomechanical behavior of the pathological tissues. Finally, we provide a summary and concluding remarks.
- 1 July 2020
- Published by IOP Publishing in Progress in Biomedical Engineering
- Vol. 2 (3) , 032002
Biochemomechanics of the thoracic aorta in health and disease
Aneurysms and dissections of the thoracic aorta are life threatening events with poorly understood pathophysiologies which may have genetic origins. By starting with an introduction to these pathologies, we focus on the biochemomechanics of the healthy thoracic aorta. Specifically, we describe the microstructure and the mechanics of the aortic tissue since it is known that the microstructure strongly influences the biomechanical behavior. This relationship is then complemented by providing more detailed information on the selected extracellular matrix components (collagen, elastic fibers and proteoglycans) and smooth muscle cells. More specifically, we introduce the roles smooth muscle cells play in the function of the aortic wall: actively (mechanically) with their contractile abilities and passively by regulating the composition of the extracellular matrix they are embedded in, in particular via the transforming growth factor β (TGF-β) pathway. Subsequently, we summarize the microstructural changes in thoracic aortic aneurysms and dissections in connection with selected risk factors and genetic mutations, and couple these changes with the findings on the biomechanical behavior of the pathological tissues. Finally, we provide a summary and concluding remarks.
- Open Access
- 1 November 2019
- Published by Elsevier in Acta Biomaterialia
- Vol. 99, 443-456
Failure properties and microstructure of healthy and aneurysmatic human thoracic aortas subjected to uniaxial extension with a focus on the media
- 1 November 2019
- Published by Elsevier in Acta Biomaterialia
- Vol. 99, 443-456
Open AccessFailure properties and microstructure of healthy and aneurysmatic human thoracic aortas subjected to uniaxial extension with a focus on the media
- Top Cited Papers
- 1 November 2019
- Published by Elsevier in Acta Biomaterialia
- Vol. 99, 1-17
Biomechanics of aortic wall failure with a focus on dissection and aneurysm: A review
- 1 November 2019
- Published by Elsevier in Acta Biomaterialia
- Vol. 99, 1-17
Top Cited PapersBiomechanics of aortic wall failure with a focus on dissection and aneurysm: A review
- Open Access
- 3 April 2019
- Published by The Royal Society in Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 475 (2224) , 20180736
On fibre dispersion modelling of soft biological tissues: a review
Collagen fibres within fibrous soft biological tissues such as artery walls, cartilage, myocardiums, corneas and heart valves are responsible for their anisotropic mechanical behaviour. It has recently been recognized that the dispersed orientation of these fibres has a significant effect on the mechanical response of the tissues. Modelling of the dispersed structure is important for the prediction of the stress and deformation characteristics in (patho)physiological tissues under various loading conditions. This paper provides a timely and critical review of the continuum modelling of fibre dispersion, specifically, the angular integration and the generalized structure tensor models. The models are used in representative numerical examples to fit sets of experimental data that have been obtained from mechanical tests and fibre structural information from second-harmonic imaging. In particular, patches of healthy and diseased aortic tissues are investigated, and it is shown that the predictions of the models fit very well with the data. It is straightforward to use the models described herein within a finite-element framework, which will enable more realistic (and clinically relevant) boundary-value problems to be solved. This also provides a basis for further developments of material models and points to the need for additional mechanical and microstructural data that can inform further advances in the material modelling.
- 3 April 2019
- Published by The Royal Society in Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 475 (2224) , 20180736
Open AccessOn fibre dispersion modelling of soft biological tissues: a review
Collagen fibres within fibrous soft biological tissues such as artery walls, cartilage, myocardiums, corneas and heart valves are responsible for their anisotropic mechanical behaviour. It has recently been recognized that the dispersed orientation of these fibres has a significant effect on the mechanical response of the tissues. Modelling of the dispersed structure is important for the prediction of the stress and deformation characteristics in (patho)physiological tissues under various loading conditions. This paper provides a timely and critical review of the continuum modelling of fibre dispersion, specifically, the angular integration and the generalized structure tensor models. The models are used in representative numerical examples to fit sets of experimental data that have been obtained from mechanical tests and fibre structural information from second-harmonic imaging. In particular, patches of healthy and diseased aortic tissues are investigated, and it is shown that the predictions of the models fit very well with the data. It is straightforward to use the models described herein within a finite-element framework, which will enable more realistic (and clinically relevant) boundary-value problems to be solved. This also provides a basis for further developments of material models and points to the need for additional mechanical and microstructural data that can inform further advances in the material modelling.
- 1 August 2016
- Published by Elsevier in Journal of Biomechanics
- Vol. 49 (12) , 2374-2382
Mechanical strength of aneurysmatic and dissected human thoracic aortas at different shear loading modes
- 1 August 2016
- Published by Elsevier in Journal of Biomechanics
- Vol. 49 (12) , 2374-2382
Mechanical strength of aneurysmatic and dissected human thoracic aortas at different shear loading modes