    Investigating the Clinical Value in Relation to Implementation and Use of an AI-Generated Fracture Algorithm Tool to Support Clinical Decision-Making

    by Mie Strandby Jul, Malene Dybdahl, Janni Jensen, Malene Roland Vils Pedersen, Jane Stigaard, Helle Precht, Ane Simony

    Background/Objectives : The use of artificial intelligence (AI) in imaging departments is increasing in Europe. This study assesses the clinical value of an AI fracture algorithm by assessing ease of use, clinicians’ trust, and perceived barriers and benefits of this decision support tool in daily practice across two emergency departments (EDs) in Denmark. Methods: An online survey was distributed over four weeks (June–July 2025) to healthcare professionals interpreting radiographs in the ED at Lillebaelt Hospital. The survey included open-ended, closed-ended, and free-text questions addressing AI use. Additionally, an observational study was conducted, including workflow observations and time tracking of patient progression through the ED. Historical injury conference records from February 2023 to 2025 were reviewed to assess changes in patient management before and after AI implementation. Results: A total of 56 responses were obtained (24 male, 32 female). Most respondents reported a positive attitude toward the algorithm. Ease of use was rated satisfactory by 51 out of 56 participants, and 48 were satisfied with AI as a clinical decision support tool. Overall trust was high, with more than two thirds (n = 38) “agreeing” or “strongly agreeing” that the algorithm reliably detects fractures. However, an asymmetry in clinical trust was observed, whereby clinicians expressed greater confidence in their own assessments when the algorithm indicated the presence of a fracture than when it did not. Value stream analyses showed a delay of 6–23 min between radiograph acquisition and availability of the AI report. No differences were observed in the number of patients with treatment changes before, during, or after full implementation of the algorithm. Conclusions: In our limited study population, the AI fracture detection tool was overall well received by clinicians, although some observations indicate that implementation and workflow integration still require improvement. Larger studies are needed to validate the reported barriers and benefits of the AI fracture detection tool.

  • Open Access

    External validation of a pre-trained hybrid convolutional neural network in radiographers agreement of positioning in lateral knee radiographs

    by Simon Lysdahlgaard, J. Jensen, M.R.V. Pedersen, K.W. Kusk, S.B. Hansen, M.W. Kusk


  • Open Access

    Evaluation of femoral neck fracture migration after internal fixation with an angle stable implant compared with gold standard cannulated cancellous screws in young adults: study protocol for a clinical RCT using radiostereometric analysis

    by Michaela Manalili Hansen, Emil Toft Petersen, Per Hviid Gundtoft, Janni Jensen, Maiken Stilling, Ming Ding, Bjarke Viberg

    Hip fractures are most commonly suffered by elderly patients, but 2–11% of hip fractures affect younger patients. In young adults with femoral neck f

  • Open Access

    Protocol for Radiographer x AI led discharge

    by Rikke Bachmann, Andreas Nexmann, Janitha Mudannayake, Janni Jensen, Sigurd S. Lauvsnes, Michael Lundemann

    Introduction: Emergency Department (ED) overcrowding, often exacerbated by prolonged patient length of stay (LOS), is a global challenge. Patients presenting with suspected fractures—many of whom are triaged as low-acuity, contribute significantly to the ED burden. Radiographer-led discharge (RLD), supported by artificial intelligence (AI), presents a potential strategy to streamline care, reduce LOS, and maintain diagnostic safety. Methods: This multi-centre, retrospective study evaluates whether diagnostic radiographers, assisted by the radiological AI decision support tool RBfracture 2 . 6 , can safely discharge patients with no acute skeletal or joint injury. Fifteen radiographers from three countries will independently assess 340 retrospective radiographic examinations (300 consecutive and 40 enriched with rare findings). Referral notes and AI predictions are available. Reference standards are established by consensus among three MSK radiologists/reporting radiographers. Primary outcomes include ED workload reduction (true negatives) and false negative rate. Secondary outcomes will assess AI standalone performance and inter-country comparison. Results: The primary object is to evaluate whether diagnostic radiographers from three different countries, assisted by the AI tool Rbfracture 2.6, can safely reduce the emergency department (ED) workload by discharging patients without acute skeletal or joint injuries, specifically those referred with suspected bone fracture or joint dislocation. A secondary objective is to validate the performance of RBfracture 2.6 in detecting fractures, joint dislocations, elbow effusions, knee effusions, and knee lipohemarthrosis.

  • Open Access

    Ulnar variance – Reliability of three different methods of measurement

    by Asger Jepsen, Benjamin S. Rasmussen, Ole Graumann, Meinhard Reinert Hansen, Hans B. Tromborg, Janni Jensen

    Objectives: Ulnar variance (UV), i.e., the length of the ulna relative to the radius is a radiographic measurement commonly used to estimate fracture compression of distal radius fractures. Different methods for measuring UV have been described in the literature. The aim of this study was to assess the inter- and intra-rater reliability of three different methods of measuring UV among raters with different professional backgrounds and levels of experience. Material and Methods: Nine raters, one musculoskeletal radiologist, three radiology residents, one PhD student, one medical student, and three reporting radiographers, participated in the study. They measured UV on 21 radiographs using three different measurement methods: The method of central reference point (CRP), the lateral method (LM), and the method of perpendiculars (MoP). Inter-rater reliability was assessed using the intra-class correlation coefficient (ICC), while intra-rater agreement was estimated using Bland–Altman (BA) analysis with limits of agreement (LoA). Results: Inter-rater reliability estimated by ICCs was 0.91, 0.96, and 0.97 for the methods of CRP, LM, and MoP, respectively. Intra-rater agreement, assessed by BA LoA for rater1/rater2, was ±2.94/±1.45, ±1.92/±2.36, and ±2.14/±1.33 for the methods of CRP, LM, and MoP, respectively. Conclusion: All three methods of measurement displayed excellent reliability with ICCs ranging from 0.91 to 0.97. The findings suggest that UV measurements can be reliably obtained across raters with different professional backgrounds and levels of experience using all three methods of measuring.

  • Open Access

    Distal radius fracture – Supination underestimates dorsal tilt in distal radius fracture radiographs: a case report

    by Sebastian P. L. Clark, Maria Ilsø, Jens C. Werlinrud, Benjamin S. Rasmussen, Janni Jensen

    Distal radius fractures are one of the most prevalent fracture types. Dorsal tilt of the articular surface of the distal radius as assessed on the lateral radiograph is often used in determining the correct treatment method. This report seeks to highlight the importance of correct forearm positioning when obtaining distal radius radiographs, and the effects of pronation and supination on dorsal tilt measurements of the radius. It presents a case of a 35-year-old male with a malaligned left-sided distal radius fracture sustained during a sports-related fall.

  • Open Access

    Standardisation and Optimisation of Chest and Pelvis X-Ray Imaging Protocols Across Multiple Radiography Systems in a Radiology Department

    by Ahmed Jibril Abdi, Kasper Rørdam Jensen, Pia Iben Pietersen, Janni Jensen, Rune Lau Hovgaard, Ask Kristian Aas Holmboe, Sofie Gregersen

    X-ray imaging protocols in radiology departments often exhibit variability in exposure parameters and geometric setups, leading to inconsistencies in image quality and potential variations in patient dose. Objectives: This study aimed to harmonise and optimise chest and pelvis X-ray imaging protocols by standardising exposure parameters and geometric setups across departmental systems, minimising radiation dose while ensuring adequate image quality for accurate diagnosis. Methods: The image quality of five pelvic and three chest protocols across different radiographic systems was evaluated both quantitatively and visually. Visual image quality for both chest and pelvis protocols was assessed by radiologists and radiographers using the Visual Grading Analysis (VGA) method. Additionally, the quantitative image quality figure inverse (IQFinv) metric for all protocols was determined using the CDRAD image quality phantom. Moreover, the patient radiation dose for both chest and pelvis protocols was evaluated using dose area product (DAP) values measured by the systems’ built-in DAP metres. Results: Different quantitative image quality and radiation dose to patients were achieved in various protocol settings for both chest and pelvis examinations, but the visual image quality assessment showed satisfactory image quality for all observers in both the pelvis and chest protocols. The selected protocols for harmonising chest radiography across all imaging systems result in reduced radiation exposure for patients while maintaining adequate image quality compared to the previously used system-specific protocol. Conclusions: The clinical protocol for chest and pelvis radiography has been standardised and optimised in accordance with patient radiation exposure and image quality. This approach aligns with the ALARA (As Low As Reasonably Achievable) principle, ensuring optimal diagnostic information while minimising the radiation risks.


  • Open Access

    Quantitative Evaluation of Image Quality and Radiation Dose Using Novel Intelligent Noise Reduction (INR) Software in Chest Radiography: A Phantom Study

    by Ahmed Jibril Abdi, Helle Precht, Claus Bjørn Outzen, Janni Jensen

    Background/Objectives: This study quantitatively evaluates the novel Intelligent Noise Reduction (INR) software NE 3.10.0.15 across three chest radiography protocols, namely, physical anti-scatter grid, non-grid, and virtual anti-scatter grid, to optimise the patient radiation dose while maintaining sufficient image quality. Methods: Quantitative image quality and radiation dose were evaluated using a CDRAD phantom with 20 cm PMMA to simulate the patient across three chest protocol settings at INR levels of 0, 5, and 8 for both PA and LAT projections. Effective doses were estimated using PCXMC Monte Carlo simulation software 2.0. Results: The findings revealed significant improvements in image quality with increasing INR levels, with INR8 consistently outperforming INR5 and non-INR settings. Protocols employing virtual or no grid achieved substantial radiation dose reductions of 77–82% compared to the physical grid. The virtual grid did enhance the quantitative image quality by 6–9% compared to non-grid configurations. Conclusions: INR software, particularly when combined with virtual anti-scatter grids, offers a promising solution for improving image quality while significantly reducing the patient radiation dose in chest radiography. Future clinical validation, incorporating subjective visual assessments by radiologists, is recommended to confirm these findings and facilitate the integration of INR closer to clinical practice.


  • Open Access

    Clinical Application of the EOS Imaging System—The Broader Horizon

    by Karen Brage, Bo Mussmann, Malene Roland Pedersen, Marcus Nissen, Oliver Brage, Svea Deppe Mørup, Mats Geijer, Palle Larsen, Janni Jensen

    Purpose: The purpose of this scoping review was to systematically identify and summarize the existing literature on non-spinal clinical applications of EOS imaging and identify related evidence gaps. Method: The study followed the PRISMA-ScR guidelines. A systematic literature search was conducted in Embase, MEDLINE, CINAHL, Scopus, Cochrane, Academic Search Premier, and OpenGrey databases in November 2022 and updated in December 2023. Original research from 2003 to 2023 was eligible if in English, Danish, French, German, Norwegian, or Swedish. Two authors screened articles by title and abstract, while data extraction from full texts was performed by seven authors using a structured template. Results: A total of 8176 articles were identified, with 1350 selected for full-text review and 268 included in data extraction. Among adults, 187 articles were included, with 88 focused on surgical applications like hip arthroplasty or osteotomy. In pediatrics, 68 general and 13 surgery-related articles were included. Lower extremity analysis was the most frequent topic, with other uses identified, such as rib cage geometry, patellar dislocation, and X-linked hypophosphatemia. Conclusions: Key clinical applications of EOS imaging include lower extremity analysis, e.g., leg length assessment and knee/hip arthroplasty planning), pelvic and spinal alignment studies, and emerging uses in rib cage geometry. Evidence gaps include limited research on the diagnostic accuracy of EOS for cerebral shunt placement, reliability in bone age estimation, and an unclear role in foot and ankle morphology.