Mikulas Mlcek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mikulas Mlcek has a total of 197 co-authors. Here are the top co-authors by number of shared publications:
- Otomar Kittnar
Institute of Physiology, First Faculty of Medicine, Charles University in Prague, Czech Republic
10 shared publications - Stepan Havranek
2nd Department of Medicine—Department of Cardiovascular Medicine of the 1st Faculty of Medicine, Charles University and General University Hospital in Prague
10 shared publications - Jan Belohlavek
General University Hospital and First Faculty of Medicine, Charles University , Prague
9 shared publications - Jaroslav Kudlicka
3rd Department of Internal Medicine, General University Hospital and 1st Faculty of Medicine, Charles University , Prague, Czech Republic
8 shared publications O. Kittnar
8 shared publications- Petr Neuzil
Na Homolce Hospital , Prague, Czechia
8 shared publications
Latest Publications
- Open Access
- 12 March 2026
- Published by Elsevier in SSRN Electronic Journal
Blood Gas Parameters During Cardio-Pulmonary Resuscitation in a Post hoc analysis- porcine study with data pooled from two studies: Increased Acidosis With Repeated Adrenaline Injections Compared to a Control Group During Prolonged Advanced Life Support
Background: Cardiopulmonary resuscitation (CPR) guidelines recommend an injection of 1 mg of adrenaline (ADR) every 3–5 minutes in a cardiac arrest (CA)-situation. ADR increases return of spontaneous circulation (ROSC) and induce a more acidotic state in CA situations. Blood gas analysis is a useful tool to assess the metabolic state during CPR.Most experimental studies have been conducted with a single injection of ADR. However, little is known about how blood gas parameters are affected by repeated ADR injections during prolonged CPR.Methods: This was a pooled post-hoc analysis from two studies, in which repeated injections of ADR and saline (NaCl) as a control were administered during 16- or 21-minutes of CPR according to current guidelines. Sixty pigs were induced with CA, randomised to either ADR or NaCl. Arterial blood gases were drawn at baseline, after the second and fourth injection of ADR/NaCl, and after 5 and 10 minutes of ROSC. The analysis included pH, Base excess (BE), Bicarbonate (HCO3-), lactate, partial pressure of carbon dioxide (pCO2), partial pressure of oxygen, oxygen saturation, Hb, and potassium (K+).Results: Sixteen animals (66.7%) obtained ROSC in the control group and 17 (47.2%) in the ADR group (ns). ADR resulted in significantly lower pH; BE and HCO3- higher lactate; pCO2, Hb and K+, compared to a control-group among animals that achieved ROSC, but not in non-ROSC groups.Conclusion: Repeated ADR injections led to a more acidotic state and higher K+ and Hb levels in animals that achieved ROSC during prolonged CPR compared with the control-group.
- 12 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessBlood Gas Parameters During Cardio-Pulmonary Resuscitation in a Post hoc analysis- porcine study with data pooled from two studies: Increased Acidosis With Repeated Adrenaline Injections Compared to a Control Group During Prolonged Advanced Life Support
Background: Cardiopulmonary resuscitation (CPR) guidelines recommend an injection of 1 mg of adrenaline (ADR) every 3–5 minutes in a cardiac arrest (CA)-situation. ADR increases return of spontaneous circulation (ROSC) and induce a more acidotic state in CA situations. Blood gas analysis is a useful tool to assess the metabolic state during CPR.Most experimental studies have been conducted with a single injection of ADR. However, little is known about how blood gas parameters are affected by repeated ADR injections during prolonged CPR.Methods: This was a pooled post-hoc analysis from two studies, in which repeated injections of ADR and saline (NaCl) as a control were administered during 16- or 21-minutes of CPR according to current guidelines. Sixty pigs were induced with CA, randomised to either ADR or NaCl. Arterial blood gases were drawn at baseline, after the second and fourth injection of ADR/NaCl, and after 5 and 10 minutes of ROSC. The analysis included pH, Base excess (BE), Bicarbonate (HCO3-), lactate, partial pressure of carbon dioxide (pCO2), partial pressure of oxygen, oxygen saturation, Hb, and potassium (K+).Results: Sixteen animals (66.7%) obtained ROSC in the control group and 17 (47.2%) in the ADR group (ns). ADR resulted in significantly lower pH; BE and HCO3- higher lactate; pCO2, Hb and K+, compared to a control-group among animals that achieved ROSC, but not in non-ROSC groups.Conclusion: Repeated ADR injections led to a more acidotic state and higher K+ and Hb levels in animals that achieved ROSC during prolonged CPR compared with the control-group.
- Open Access
- 4 February 2025
- Published by Elsevier in Resuscitation Plus
- Vol. 22, 100893
Adrenaline has a limited effect on myocardial microvascular blood flow: A randomised experimental study in a porcine cardiac arrest model
- 4 February 2025
- Published by Elsevier in Resuscitation Plus
- Vol. 22, 100893
Open AccessAdrenaline has a limited effect on myocardial microvascular blood flow: A randomised experimental study in a porcine cardiac arrest model
- Top Cited Papers
- 1 June 2024
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 17 (6) , e012765
Hemolysis After Pulsed Field Ablation: Impact of Lesion Number and Catheter-Tissue Contact
- 1 June 2024
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 17 (6) , e012765
Top Cited PapersHemolysis After Pulsed Field Ablation: Impact of Lesion Number and Catheter-Tissue Contact
- Open Access
- 28 December 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (1) , 493
Acute Severe Heart Failure Reduces Heart Rate Variability: An Experimental Study in a Porcine Model
There are substantial differences in autonomic nervous system activation among heart (cardiac) failure (CF) patients. The effect of acute CF on autonomic function has not been well explored. The aim of our study was to assess the effect of experimental acute CF on heart rate variability (HRV). Twenty-four female pigs with a mean body weight of 45 kg were used. Acute severe CF was induced by global myocardial hypoxia. In each subject, two 5-min electrocardiogram segments were analyzed and compared: before the induction of myocardial hypoxia and >60 min after the development of severe CF. HRV was assessed by time-domain, frequency-domain and nonlinear analytic methods. The induction of acute CF led to a significant decrease in cardiac output, left ventricular ejection fraction and an increase in heart rate. The development of acute CF was associated with a significant reduction in the standard deviation of intervals between normal beats (50.8 [20.5–88.1] ms versus 5.9 [2.4–11.7] ms, p < 0.001). Uniform HRV reduction was also observed in other time-domain and major nonlinear analytic methods. Similarly, frequency-domain HRV parameters were significantly changed. Acute severe CF induced by global myocardial hypoxia is associated with a significant reduction in HRV.
- 28 December 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (1) , 493
Open AccessAcute Severe Heart Failure Reduces Heart Rate Variability: An Experimental Study in a Porcine Model
There are substantial differences in autonomic nervous system activation among heart (cardiac) failure (CF) patients. The effect of acute CF on autonomic function has not been well explored. The aim of our study was to assess the effect of experimental acute CF on heart rate variability (HRV). Twenty-four female pigs with a mean body weight of 45 kg were used. Acute severe CF was induced by global myocardial hypoxia. In each subject, two 5-min electrocardiogram segments were analyzed and compared: before the induction of myocardial hypoxia and >60 min after the development of severe CF. HRV was assessed by time-domain, frequency-domain and nonlinear analytic methods. The induction of acute CF led to a significant decrease in cardiac output, left ventricular ejection fraction and an increase in heart rate. The development of acute CF was associated with a significant reduction in the standard deviation of intervals between normal beats (50.8 [20.5–88.1] ms versus 5.9 [2.4–11.7] ms, p < 0.001). Uniform HRV reduction was also observed in other time-domain and major nonlinear analytic methods. Similarly, frequency-domain HRV parameters were significantly changed. Acute severe CF induced by global myocardial hypoxia is associated with a significant reduction in HRV.
- Open Access
- 27 April 2022
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 13, 881658
New Porcine Model of Arteriovenous Fistula Documents Increased Coronary Blood Flow at the Cost of Brain Perfusion
Background: Arteriovenous fistulas (AVF) represent a low resistant circuit. It is known that their opening leads to decreased systemic vascular resistance, increased cardiac output and other hemodynamic changes. Possible competition of AVF and perfusion of other organs has been observed before, however the specific impact of AVF has not been elucidated yet. Previous animal models studied long-term changes associated with a surgically created high flow AVF. The aim of this study was to create a simple AVF model for the analysis of acute hemodynamic changes.Methods: Domestic female pigs weighing 62.6 ± 5.2 kg were used. All the experiments were held under general anesthesia. The AVF was created using high-diameter ECMO cannulas inserted into femoral artery and vein. Continuous hemodynamic monitoring was performed throughout the protocol. Near-infrared spectroscopy sensors, flow probes and flow wires were inserted to study brain and heart perfusion.Results: AVF blood flow was 2.1 ± 0.5 L/min, which represented around 23% of cardiac output. We observed increase in cardiac output (from 7.02 ± 2.35 L/min to 9.19 ± 2.99 L/min, p = 0.0001) driven dominantly by increased heart rate, increased pulmonary artery pressure, and associated right ventricular work. Coronary artery flow velocity rose. On the contrary, carotid artery flow and brain and muscle tissue oxygenation measured by NIRS decreased significantly.Conclusions: Our new non-surgical AVF model is reproducible and demonstrated an acute decrease of brain and muscle perfusion.
- 27 April 2022
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 13, 881658
Open AccessNew Porcine Model of Arteriovenous Fistula Documents Increased Coronary Blood Flow at the Cost of Brain Perfusion
Background: Arteriovenous fistulas (AVF) represent a low resistant circuit. It is known that their opening leads to decreased systemic vascular resistance, increased cardiac output and other hemodynamic changes. Possible competition of AVF and perfusion of other organs has been observed before, however the specific impact of AVF has not been elucidated yet. Previous animal models studied long-term changes associated with a surgically created high flow AVF. The aim of this study was to create a simple AVF model for the analysis of acute hemodynamic changes.Methods: Domestic female pigs weighing 62.6 ± 5.2 kg were used. All the experiments were held under general anesthesia. The AVF was created using high-diameter ECMO cannulas inserted into femoral artery and vein. Continuous hemodynamic monitoring was performed throughout the protocol. Near-infrared spectroscopy sensors, flow probes and flow wires were inserted to study brain and heart perfusion.Results: AVF blood flow was 2.1 ± 0.5 L/min, which represented around 23% of cardiac output. We observed increase in cardiac output (from 7.02 ± 2.35 L/min to 9.19 ± 2.99 L/min, p = 0.0001) driven dominantly by increased heart rate, increased pulmonary artery pressure, and associated right ventricular work. Coronary artery flow velocity rose. On the contrary, carotid artery flow and brain and muscle tissue oxygenation measured by NIRS decreased significantly.Conclusions: Our new non-surgical AVF model is reproducible and demonstrated an acute decrease of brain and muscle perfusion.
- Open Access
- 1 December 2021
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 14 (24) , 2698-2707
Atrial Septostomy for Left Ventricular Unloading During Extracorporeal Membrane Oxygenation for Cardiogenic Shock
- 1 December 2021
- Published by Elsevier in JACC: Cardiovascular Interventions
- Vol. 14 (24) , 2698-2707
Open AccessAtrial Septostomy for Left Ventricular Unloading During Extracorporeal Membrane Oxygenation for Cardiogenic Shock
- Open Access
- 24 April 2021
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 21 (1) , 1-7
Targeted lateral positioning decreases lung collapse and overdistension in COVID-19-associated ARDS
Background: Among the challenges for personalizing the management of mechanically ventilated patients with coronavirus disease (COVID-19)-associated acute respiratory distress syndrome (ARDS) are the effects of different positive end-expiratory pressure (PEEP) levels and body positions in regional lung mechanics. Right-left lung aeration asymmetry and poorly recruitable lungs with increased recruitability with alternating body position between supine and prone have been reported. However, real-time effects of changing body position and PEEP on regional overdistension and collapse, in individual patients, remain largely unknown and not timely monitored. The aim of this study was to individualize PEEP and body positioning in order to reduce the mechanisms of ventilator-induced lung injury: collapse and overdistension. Methods: We here report a series of five consecutive mechanically ventilated patients with COVID-19-associated ARDS in which sixteen decremental PEEP titrations were performed in the first days of mechanical ventilation (8 titration pairs: supine position immediately followed by 30° targeted lateral position). The choice of lateral tilt was based on X-Ray. This targeted lateral position strategy was defined by selecting the less aerated lung to be positioned up and the more aerated lung to be positioned down. For each PEEP level, global and regional collapse and overdistension maps and percentages were measured by electrical impedance tomography. Additionally, we present the incidence of lateral asymmetry in a cohort of forty-four patients. Results: The targeted lateral position strategy resulted in significantly smaller amounts of overdistension and collapse when compared with the supine one: less collapse along the PEEP titration was found within the left lung in targeted lateral (P = 0.014); and less overdistension along the PEEP titration was found within the right lung in targeted lateral (P = 0.005). Regarding collapse within the right lung and overdistension within the left lung: no differences were found for position. In the cohort of forty-four patients, ventilation inequality of > 65/35% was observed in 15% of cases. Conclusions: Targeted lateral positioning with bedside personalized PEEP provided a selective attenuation of overdistension and collapse in mechanically ventilated patients with COVID-19-associated ARDS and right-left lung aeration/ventilation asymmetry. Trial registration: Trial registration number: NCT04460859
- 24 April 2021
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 21 (1) , 1-7
Open AccessTargeted lateral positioning decreases lung collapse and overdistension in COVID-19-associated ARDS
Background: Among the challenges for personalizing the management of mechanically ventilated patients with coronavirus disease (COVID-19)-associated acute respiratory distress syndrome (ARDS) are the effects of different positive end-expiratory pressure (PEEP) levels and body positions in regional lung mechanics. Right-left lung aeration asymmetry and poorly recruitable lungs with increased recruitability with alternating body position between supine and prone have been reported. However, real-time effects of changing body position and PEEP on regional overdistension and collapse, in individual patients, remain largely unknown and not timely monitored. The aim of this study was to individualize PEEP and body positioning in order to reduce the mechanisms of ventilator-induced lung injury: collapse and overdistension. Methods: We here report a series of five consecutive mechanically ventilated patients with COVID-19-associated ARDS in which sixteen decremental PEEP titrations were performed in the first days of mechanical ventilation (8 titration pairs: supine position immediately followed by 30° targeted lateral position). The choice of lateral tilt was based on X-Ray. This targeted lateral position strategy was defined by selecting the less aerated lung to be positioned up and the more aerated lung to be positioned down. For each PEEP level, global and regional collapse and overdistension maps and percentages were measured by electrical impedance tomography. Additionally, we present the incidence of lateral asymmetry in a cohort of forty-four patients. Results: The targeted lateral position strategy resulted in significantly smaller amounts of overdistension and collapse when compared with the supine one: less collapse along the PEEP titration was found within the left lung in targeted lateral (P = 0.014); and less overdistension along the PEEP titration was found within the right lung in targeted lateral (P = 0.005). Regarding collapse within the right lung and overdistension within the left lung: no differences were found for position. In the cohort of forty-four patients, ventilation inequality of > 65/35% was observed in 15% of cases. Conclusions: Targeted lateral positioning with bedside personalized PEEP provided a selective attenuation of overdistension and collapse in mechanically ventilated patients with COVID-19-associated ARDS and right-left lung aeration/ventilation asymmetry. Trial registration: Trial registration number: NCT04460859
- 25 June 2020
- Published by Institute of Physiology of the Czech Academy of Sciences in Physiological Research
- Vol. 69 (4) , 609-620
Increasing veno-arterial extracorporeal membrane oxygenation flow reduces electrical impedance of the lung regions in porcine acute heart failure
Veno-arterial extracorporeal membrane oxygenation (VA ECMO) is a technique used in patients with severe heart failure. The aim of this study was to evaluate its effects on left ventricular afterload and fluid accumulation in lungs with electrical impedance tomography (EIT). In eight swine, incremental increases of extracorporeal blood flow (EBF) were applied before and after the induction of ischemic heart failure. Hemodynamic parameters were continuously recorded and computational analysis of EIT was used to determine lung fluid accumulation. With an increase in EBF from 1 to 4 l/min in acute heart failure the associated increase of arterial pressure (raised by 44 %) was accompanied with significant decrease of electrical impedance of lung regions. Increasing EBF in healthy circulation did not cause lung impedance changes. Our findings indicate that in severe heart failure EIT may reflect fluid accumulation in lungs due to increasing EBF.
- 25 June 2020
- Published by Institute of Physiology of the Czech Academy of Sciences in Physiological Research
- Vol. 69 (4) , 609-620
Increasing veno-arterial extracorporeal membrane oxygenation flow reduces electrical impedance of the lung regions in porcine acute heart failure
Veno-arterial extracorporeal membrane oxygenation (VA ECMO) is a technique used in patients with severe heart failure. The aim of this study was to evaluate its effects on left ventricular afterload and fluid accumulation in lungs with electrical impedance tomography (EIT). In eight swine, incremental increases of extracorporeal blood flow (EBF) were applied before and after the induction of ischemic heart failure. Hemodynamic parameters were continuously recorded and computational analysis of EIT was used to determine lung fluid accumulation. With an increase in EBF from 1 to 4 l/min in acute heart failure the associated increase of arterial pressure (raised by 44 %) was accompanied with significant decrease of electrical impedance of lung regions. Increasing EBF in healthy circulation did not cause lung impedance changes. Our findings indicate that in severe heart failure EIT may reflect fluid accumulation in lungs due to increasing EBF.
- Open Access
- 24 September 2018
- Published by Springer Nature in Intensive Care Medicine Experimental
- Vol. 6 (1) , 36
Validation of new marker of fluid responsiveness based on Doppler assessment of blood flow velocity in superior vena cava in mechanically ventilated pigs
We studied a novel approach for the evaluation and management of volemia: minimally invasive monitoring of respiratory blood flow variations in the superior vena cava (SVC). We performed an experiment with 10 crossbred (Landrace × large white) female pigs (Sus scrofa domestica). Hypovolemia was induced by bleeding from a femoral artery, in six stages. This was followed by blood return and then an infusion of 1000 ml saline, resulting in hypervolemia. Flow in the SVC was measured by Flowire (Volcano corp., USA), located in a distal channel of a triple-lumen central venous catheter. The key parameters measured were venous return variation index (VRV)—a new index for fluid responsiveness, calculated from the maximal and minimal velocity time intervals during controlled ventilation—and systolic peak velocity (defined as peak velocity of a systolic wave using the final end-expiratory beat). A Swan–Ganz catheter (Edwards Lifesciences, USA) was introduced into the pulmonary artery to measure pulmonary arterial pressure, pulmonary capillary wedge pressure, and continuous cardiac output measurements, using the Vigilance monitor (Edwards Lifesciences, USA). We analyzed 44 VRV index measurements during defined hemodynamic status events. The curves of VRV indexes for volume responders and volume non-responders intersected at a VRV value of 27, with 10% false negativity and 2% false positivity. We compared the accuracy of VRV and pulse pressure variations (PPV) for separation of fluid responders and fluid non-responders using receiver operating characteristic (ROC) curves. VRV was better (AUCROC 0.96) than PPV (AUCROC 0.85) for identification of fluid responders. The VRV index exhibited the highest relative change during both hypovolemia and hypervolemia, compared to standard hemodynamic measurement. The VRV index provides a real-time method for continuous assessment of fluid responsiveness. It combines the advantages of echocardiography-based methods with a direct and continuous assessment of right ventricular filling during mechanical ventilation.
- 24 September 2018
- Published by Springer Nature in Intensive Care Medicine Experimental
- Vol. 6 (1) , 36
Open AccessValidation of new marker of fluid responsiveness based on Doppler assessment of blood flow velocity in superior vena cava in mechanically ventilated pigs
We studied a novel approach for the evaluation and management of volemia: minimally invasive monitoring of respiratory blood flow variations in the superior vena cava (SVC). We performed an experiment with 10 crossbred (Landrace × large white) female pigs (Sus scrofa domestica). Hypovolemia was induced by bleeding from a femoral artery, in six stages. This was followed by blood return and then an infusion of 1000 ml saline, resulting in hypervolemia. Flow in the SVC was measured by Flowire (Volcano corp., USA), located in a distal channel of a triple-lumen central venous catheter. The key parameters measured were venous return variation index (VRV)—a new index for fluid responsiveness, calculated from the maximal and minimal velocity time intervals during controlled ventilation—and systolic peak velocity (defined as peak velocity of a systolic wave using the final end-expiratory beat). A Swan–Ganz catheter (Edwards Lifesciences, USA) was introduced into the pulmonary artery to measure pulmonary arterial pressure, pulmonary capillary wedge pressure, and continuous cardiac output measurements, using the Vigilance monitor (Edwards Lifesciences, USA). We analyzed 44 VRV index measurements during defined hemodynamic status events. The curves of VRV indexes for volume responders and volume non-responders intersected at a VRV value of 27, with 10% false negativity and 2% false positivity. We compared the accuracy of VRV and pulse pressure variations (PPV) for separation of fluid responders and fluid non-responders using receiver operating characteristic (ROC) curves. VRV was better (AUCROC 0.96) than PPV (AUCROC 0.85) for identification of fluid responders. The VRV index exhibited the highest relative change during both hypovolemia and hypervolemia, compared to standard hemodynamic measurement. The VRV index provides a real-time method for continuous assessment of fluid responsiveness. It combines the advantages of echocardiography-based methods with a direct and continuous assessment of right ventricular filling during mechanical ventilation.
- Open Access
- 22 May 2018
- Published by SAGE Publications in Perfusion
- Vol. 33 (1_suppl) , 65-70
Brain perfusion evaluated by regional tissue oxygenation as a possible quality indicator of ongoing cardiopulmonary resuscitation. An experimental porcine cardiac arrest study
Introduction: Relationship between regional tissue oxygenation (rSO2) and microcirculatory changes during cardiac arrest (CA) are still unclear. Therefore, we designed an experimental study to correlate rSO2, microcirculation and systemic hemodynamic parameters in a porcine model of CA. Methods: Ventricular fibrillation was induced in 24 female pigs (50±3kg) and left for three minutes untreated followed by five minutes of mechanical CPR. Regional and peripheral saturations were assessed by near-infrared spectroscopy, sublingual microcirculation by Sidestream Dark Field technology and continuous hemodynamic parameters, including systemic blood pressure (MAP) and carotid blood flow (CF), during baseline, CA and CPR periods. The Wilcoxon Signed-Rank test, the Friedman test and the partial correlation method were used to compare these parameters. Results: Brain and peripheral rSO2 showed a gradual decrease during CA and only an increase of brain rSO2 during mechanical CPR (34.5 to 42.5; p=0.0001), reflected by a rapid decrease of microcirculatory and hemodynamic parameters during CA and a slight increase during CPR. Peripheral rSO2 was not changed significantly during CPR (38 to 38.5; p=0.09). We only found a moderate correlation of cerebral/peripheral rSO2 to microcirculatory parameters (PVD: r=0.53/0.46; PPV: r=0.6/0.5 and MFI: r=0.64/0.52) and hemodynamic parameters (MAP: r=0.64/0.71 and CF: 0.71/0.67). Conclusions: Our experimental study confirmed that monitoring brain and peripheral rSO2 is an easy-to-use method, well reflecting the hemodynamics during CA. However, only brain rSO2 reflects the CPR efforts and might be used as a potential quality indicator for CPR.
- 22 May 2018
- Published by SAGE Publications in Perfusion
- Vol. 33 (1_suppl) , 65-70
Open AccessBrain perfusion evaluated by regional tissue oxygenation as a possible quality indicator of ongoing cardiopulmonary resuscitation. An experimental porcine cardiac arrest study
Introduction: Relationship between regional tissue oxygenation (rSO2) and microcirculatory changes during cardiac arrest (CA) are still unclear. Therefore, we designed an experimental study to correlate rSO2, microcirculation and systemic hemodynamic parameters in a porcine model of CA. Methods: Ventricular fibrillation was induced in 24 female pigs (50±3kg) and left for three minutes untreated followed by five minutes of mechanical CPR. Regional and peripheral saturations were assessed by near-infrared spectroscopy, sublingual microcirculation by Sidestream Dark Field technology and continuous hemodynamic parameters, including systemic blood pressure (MAP) and carotid blood flow (CF), during baseline, CA and CPR periods. The Wilcoxon Signed-Rank test, the Friedman test and the partial correlation method were used to compare these parameters. Results: Brain and peripheral rSO2 showed a gradual decrease during CA and only an increase of brain rSO2 during mechanical CPR (34.5 to 42.5; p=0.0001), reflected by a rapid decrease of microcirculatory and hemodynamic parameters during CA and a slight increase during CPR. Peripheral rSO2 was not changed significantly during CPR (38 to 38.5; p=0.09). We only found a moderate correlation of cerebral/peripheral rSO2 to microcirculatory parameters (PVD: r=0.53/0.46; PPV: r=0.6/0.5 and MFI: r=0.64/0.52) and hemodynamic parameters (MAP: r=0.64/0.71 and CF: 0.71/0.67). Conclusions: Our experimental study confirmed that monitoring brain and peripheral rSO2 is an easy-to-use method, well reflecting the hemodynamics during CA. However, only brain rSO2 reflects the CPR efforts and might be used as a potential quality indicator for CPR.