MDMarkus Dietmannsberger

Markus Dietmannsberger

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Markus Dietmannsberger has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Quantitative comparison of costs and emissions of fossil-fuelled and electric heating in electric bus systems

    by T. Dahlmann, C. Horn, M. Dietmannsberger

    When converting bus fleets from fossil-fuelled to emission-free drives, transport companies have to face major challenges in optimum system design. One approach for bridging the gap so far is using auxiliary fossil-fuelled heating in electric buses in order to increase the available range to the required minimum. However, this can only be a short-term solution on the way to emission-free transport systems until batteries provide enough range even with electric heating. This paper provides a modelling and evaluation approach to compare several batteryelectric bus systems with either fossil-fuelled or electric heating with regard to vehicle demand, costs and CO2 emissions. For this purpose vehicles, required infrastructure, bus operation and fuel or electricity consumption are modelled for costs and emissions respectively. The use of data derived from several years of bus operation with different propulsion systems and batteryelectric buses, in particular, allows results with a certain validity to be optained, although assumptions were still made in both cost and emission analyses. It is shown that in some cases, a shift to electric heating can be accomplished without additional vehicle demand, only a few percent of additional costs and a significant reduction of emissions. But depending on the vehicle and battery type, the additional emissions for increased vehicle demand sometimes almost overcompensate the emissions saved from heating and hence, overall savings are very small. This paper discusses the dependencies and interactions between the gains and losses when shifting to electric heating and throws a spotlight on the critical questions that need to be investigated and answered before making such a decision. Another finding is that emission-free bus systems with electric heating are only economical compared to diesel buses at a price of about 800 to 1,200 euros per ton CO2. The current CO2 price for consumers and industry in Germany in 2021 is 25 euros per ton. Thus, CO2 pricing needs to be changed radically in order to give economic incentives for a transition to emission-free bus systems.

  • Modelling and Assessment of System Costs and CO2-Emissions for Electrification of Bus Fleets

    by Markus Dietmannsberger, Jorg Burkhardt

    The transition of mobility from fossil-fuelled to emission-free drives is gaining speed in public transport. Transport companies have to face challenges in increased complexity when identifying an optimum system approach and choosing the most suitable technology. A modelling and evaluation approach is introduced to compare the diesel to several battery-electric bus systems and permits the assessment of the importance of each of the system components. Although the modelling is quite simple, the use of data derived from several years of bus operation provides reliable results that show annualized costs are about 30 percent higher and that the main cost drivers are the high investment costs for buses and batteries. CO 2 emissions have been reduced by at least two-thirds whereas the remaining emissions mainly result from the manufacturing of the batteries. Sensitivity analyses show that a carefully thought out matching of bus and battery lifetime is crucial in order to optimize both annual costs and emission savings. Due to the simplicity of the model, it can easily be adopted by other transport companies and yet high quality of results can be ensured while still relying on data derived from bus operation.


  • Restoration of Low-Voltage Distribution Systems With Inverter-Interfaced DG Units

    by Markus Dietmannsberger, Xiongfei Wang, Frede Blaabjerg, Detlef Schulz

    The increasing share of distributed generation (DG) offers new chances in grid restoration of low-voltage distribution grids. Instead of relying on the transmission or high- and medium-voltage levels, establishing islanding operation in low-voltage grids might be a good option after a wide-area voltage collapse. This paper proposes a restoration strategy from zero voltage conditions for inverter-interfaced DG under islanded conditions. In the approach, a flexible and scalable Master DG inverter concept is introduced for distributed generations, where no communication is needed and an outage of the Master can be balanced by other DG inverters. The control strategy ensures the tracking of nominal values of the system voltage and frequency without zero steady-state error. The influences of non-controllable DG are also taken into account in the strategy with an effective countermeasure developed. Experimental results verify the effectiveness of the proposed approach.


  • Impacts of Low-Voltage Distribution Grid Codes on Ancillary Services and Anti-Islanding Detection of Inverter-Based Generation

    by Markus Dietmannsberger, Detlef Schulz

    The capacity to provide ancillary services has become more and more important for generators in the distribution grid. New grid codes have been implemented which regulate inverter behavior regarding different aspects of system safety and stability. This mainly includes the frequency-dependent power reduction or the allocation of reactive power. These standards affect mains monitoring because the power control directly changes penetration after the generator has islanded. In this paper, equations for active and reactive power balance are set up and developed further. Non-Detection Zones for different control methods are shown. These are then described and interpreted in detail to show how different effects that result from grid codes interfere with one another. Frequency-dependent power reduction was found to change the size and shape of the Non-Detection Zones. Reactive power control results in a shift of the Non-Detection Zones. In fact, even the initial operating point before loss of mains has an impact on inverter behavior after islanding. Islanding operating points are sometimes undefined which leads to oscillation. An interpretation of the results and advice for future revisions of grid codes conclude the paper.


  • Ancillary services and dynamic behavior of inverters connected to the low voltage grid

    by Markus Dietmannsberger, Detlef Schulz

    Small generators connected to the low voltage grid must be able to provide ancillary services in order to support system stability nowadays and in the future. Grid codes have been implemented that demand for load-frequency control and reactive power control. Together with anti-islanding-detection, these control algorithms mainly affect the dynamic behavior of the inverters in case of loss of mains. In this paper, an inverter model is presented that complies with the major grid codes. Islanding tests show new effects that arise because of the interaction between different control algorithms. Oscillating operating points may occur under special circumstances. This leads to further investigations on frequency dynamics. The additional benefit of rate-of-change-of-frequency (ROCOF) monitoring is numbered in a quantitative analysis and simulation. Not only steady state, but dynamic behavior is investigated with respect to the Non-Detection-Zone (NDZ). It is shown, that using frequency dynamics, scales down NDZs of passive anti-islanding methods significantly.