Joshua Scott Niedzielski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Joshua Scott Niedzielski has a total of 149 co-authors. Here are the top co-authors by number of shared publications:
- Laurence Edward Court
Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX
10 shared publications Zhongxing Liao
10 shared publicationsLaurence E. Court
Department of Radiation Physics, The University of Texas MD Anderson Cancer Center
7 shared publications- Jinzhong Yang
Department of Radiation Physics The University of Texas MD Anderson Cancer Center Houston Texas USA
6 shared publications Daniel R. Gomez
Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY, USA
5 shared publicationsSaurabh S. Nair
Department of Radiation Physics, The University of Texas MD Anderson Cancer Center
5 shared publications
Latest Publications
- Open Access
- 1 April 2026
- Published by UT MD Anderson Cancer Center Research Medical Library in Advances in Cancer Education and Quality Improvement
- Vol. 2 (1) , 1
TOM: Treatment Outcome Monitor - A Web-Based Tool Designed Specifically for Clinics With Limited Resources
Background: Although three-fourths of cancer deaths are expected to occur in low- and middle-income countries (LMICs) by 2030, most cancer research still comes from high-income countries. One barrier to cancer research in LMICs is lack of infrastructure for systematic data collection, including electronic medical record systems. We developed Treatment Outcome Monitor (TOM), a cloud-based tool for tracking cancer patient outcomes, designed specifically for resource-limited settings. Methods: TOM was developed through iterative design cycles with continuous feedback from health care providers from across the world. We focused on creating a simple, web-based solution that addresses real-world challenges in resource-limited settings. The platform includes questionnaire creation, patient data tracking, and automated patient communication via text or email. We created detailed user instructions for 9 core tasks and conducted usability testing. Six health care professionals (4 radiation oncologists, 1 oncology surgeon, and 1 medical physicist) completed all tasks and rated their confidence and ease of use on a 5-point Likert scale (1 = lowest, 5 = highest). Results: During development, end users identified critical requirements that shaped the platform. Key features included cloud-based architecture to eliminate local IT infrastructure needs, printable questionnaires for offline use during internet outages, patient messaging to address poor clinic follow-up rates, and integration of standardized patient-reported outcome measures. The platform achieved high usability scores. Five users (83%) rated all tasks as 4 or 5 for both confidence and ease of use. One user gave lower ratings for some tasks (ratings of 3). Overall, 92% of all responses (99 of 108 total ratings across all users and tasks) scored 4 or 5, indicating high usability. Conclusions: We successfully developed a user-friendly, cloud-based platform for cancer outcome monitoring and data collection in resource-limited settings. Through collaborative design with end users, TOM addresses practical barriers including limited IT infrastructure, unreliable internet, and poor patient follow-up. The high usability scores demonstrate that thoughtful, user-centered design can create tools that are both technically sound and appropriate for resource-limited contexts. By simplifying systematic data collection, TOM may help enable clinics in LMICs to participate more fully in cancer research.
- 1 April 2026
- Published by UT MD Anderson Cancer Center Research Medical Library in Advances in Cancer Education and Quality Improvement
- Vol. 2 (1) , 1
Open AccessTOM: Treatment Outcome Monitor - A Web-Based Tool Designed Specifically for Clinics With Limited Resources
Background: Although three-fourths of cancer deaths are expected to occur in low- and middle-income countries (LMICs) by 2030, most cancer research still comes from high-income countries. One barrier to cancer research in LMICs is lack of infrastructure for systematic data collection, including electronic medical record systems. We developed Treatment Outcome Monitor (TOM), a cloud-based tool for tracking cancer patient outcomes, designed specifically for resource-limited settings. Methods: TOM was developed through iterative design cycles with continuous feedback from health care providers from across the world. We focused on creating a simple, web-based solution that addresses real-world challenges in resource-limited settings. The platform includes questionnaire creation, patient data tracking, and automated patient communication via text or email. We created detailed user instructions for 9 core tasks and conducted usability testing. Six health care professionals (4 radiation oncologists, 1 oncology surgeon, and 1 medical physicist) completed all tasks and rated their confidence and ease of use on a 5-point Likert scale (1 = lowest, 5 = highest). Results: During development, end users identified critical requirements that shaped the platform. Key features included cloud-based architecture to eliminate local IT infrastructure needs, printable questionnaires for offline use during internet outages, patient messaging to address poor clinic follow-up rates, and integration of standardized patient-reported outcome measures. The platform achieved high usability scores. Five users (83%) rated all tasks as 4 or 5 for both confidence and ease of use. One user gave lower ratings for some tasks (ratings of 3). Overall, 92% of all responses (99 of 108 total ratings across all users and tasks) scored 4 or 5, indicating high usability. Conclusions: We successfully developed a user-friendly, cloud-based platform for cancer outcome monitoring and data collection in resource-limited settings. Through collaborative design with end users, TOM addresses practical barriers including limited IT infrastructure, unreliable internet, and poor patient follow-up. The high usability scores demonstrate that thoughtful, user-centered design can create tools that are both technically sound and appropriate for resource-limited contexts. By simplifying systematic data collection, TOM may help enable clinics in LMICs to participate more fully in cancer research.
- Open Access
- 4 February 2026
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 15, 1731259
Novel pencil-beam scanning proton lattice radiation therapy for the treatment of bulky liver cancer: dosimetric comparison with VMAT-lattice radiotherapy
Background: Spatially fractionated radiotherapy (SFRT) delivered as lattice radiotherapy (LRT) creates high-dose ‘vertex’ subvolumes (VTVH) embedded within low-dose ‘valley’ regions (VTVL) to intensify intratumoral dose while minimizing radiation dose and toxicity to organs at risk (OARs). We developed a pencil-beam scanning (PBS) intensity modulated proton therapy (IMPT) LRT planning approach and dosimetrically compared it directly with contemporary photon-based volume modulated arc therapy (VMAT) LRT for liver cancer with bulky tumors. Methods: Twenty-one retrospective liver cases were replanned in RayStation to a single fraction of 20 Gy to VTVH with explicit VTVL sparing (mean dose <5Gy). Primary dosimetric endpoints were VTVH D80 and VTVL mean dose (analogous to mean valley dose), with secondary endpoints of VTVH/VTVL ratios (PVDR-like metrics at D80/D90/D100), VTVL D5/D80, GTV D10/D90, and planning risk volume (PRV) 0.03 cm³ hotspots. Statistical analysis consisted of paired tests (t-test or Wilcoxon signed-rank) after assessing data normality (Shapiro-Wilk tests) and using α=0.05 for significance. Results: Compared with photon VMAT-LRT, IMPT-LRT significantly reduced VTVL mean dose (p<0.00001) and increased VTVH D80 (p<0.00001), yielding higher VTVH/VTVL ratios at D80/D90/D100 (all p<0.00001). Gross tumor volume (GTV) heterogeneity (D20/D80) significantly increased with proton-LRT (p<0.00001) and OAR hot-spot metrics (PRV D0.03cc) were comparable between both modalities (p=0.71). Conclusions: A robust PBS proton-LRT planning approach was developed and compared to photon VMAT-LRT for large liver tumors. Our IMPT-LRT approach maximizes peak-to-valley separation and simultaneously maintains target coverage while significantly reducing valley dose, as compared to traditional VMAT-LRT. These findings support future prospective clinical evaluation.
- 4 February 2026
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 15, 1731259
Open AccessNovel pencil-beam scanning proton lattice radiation therapy for the treatment of bulky liver cancer: dosimetric comparison with VMAT-lattice radiotherapy
Background: Spatially fractionated radiotherapy (SFRT) delivered as lattice radiotherapy (LRT) creates high-dose ‘vertex’ subvolumes (VTVH) embedded within low-dose ‘valley’ regions (VTVL) to intensify intratumoral dose while minimizing radiation dose and toxicity to organs at risk (OARs). We developed a pencil-beam scanning (PBS) intensity modulated proton therapy (IMPT) LRT planning approach and dosimetrically compared it directly with contemporary photon-based volume modulated arc therapy (VMAT) LRT for liver cancer with bulky tumors. Methods: Twenty-one retrospective liver cases were replanned in RayStation to a single fraction of 20 Gy to VTVH with explicit VTVL sparing (mean dose <5Gy). Primary dosimetric endpoints were VTVH D80 and VTVL mean dose (analogous to mean valley dose), with secondary endpoints of VTVH/VTVL ratios (PVDR-like metrics at D80/D90/D100), VTVL D5/D80, GTV D10/D90, and planning risk volume (PRV) 0.03 cm³ hotspots. Statistical analysis consisted of paired tests (t-test or Wilcoxon signed-rank) after assessing data normality (Shapiro-Wilk tests) and using α=0.05 for significance. Results: Compared with photon VMAT-LRT, IMPT-LRT significantly reduced VTVL mean dose (p<0.00001) and increased VTVH D80 (p<0.00001), yielding higher VTVH/VTVL ratios at D80/D90/D100 (all p<0.00001). Gross tumor volume (GTV) heterogeneity (D20/D80) significantly increased with proton-LRT (p<0.00001) and OAR hot-spot metrics (PRV D0.03cc) were comparable between both modalities (p=0.71). Conclusions: A robust PBS proton-LRT planning approach was developed and compared to photon VMAT-LRT for large liver tumors. Our IMPT-LRT approach maximizes peak-to-valley separation and simultaneously maintains target coverage while significantly reducing valley dose, as compared to traditional VMAT-LRT. These findings support future prospective clinical evaluation.
- Open Access
- 27 November 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (12) , e70386
Monte Carlo simulations of geometric deformation of Harrison–Anderson–Mick applicators used in intraoperative radiation therapy
Background: The Harrison–Anderson–Mick (HAM) applicator is a high‐dose‐rate intraoperative radiotherapy (HDR‐IORT) applicator used to position Ir‐192 brachytherapy sources over surgically‐accessed tumor volumes or post‐resection tumor beds. Because of the lack of a 3D imaging system, dwell times are optimized pre‐surgery by a TG‐43–based treatment planning system (TPS) that assumes a perfectly flat applicator surface surrounded by an infinite water phantom. These assumed conditions are disparate from typical treatment conditions, especially in the pelvic regions, which often involve uneven patient surfaces and superficial irradiations with little to no backscatter material. Purpose: Develop and validate a Monte Carlo (MC) model of HDR‐IORT treatment with a HAM applicator and use this validated model to quantify inaccuracies in the dose calculations due to the simplified conditions assumed in the planning process. Methods: The Oncentra Brachy TPS was used to optimize dwell times and calculate the delivered relative dose distribution for a 6‐catheter, 8‐cm HAM applicator with 0.5‐cm dwell steps and 1.0‐cm catheter spacing. A TOPAS (v.3.9) MC model of this treatment was then developed and validated against the TPS dose calculations. Once validated, the TOPAS applicator model was modified to calculate the difference in doses due to changes in backscatter conditions, the incorporation of the actual applicator materials, and curvature of the applicator. Dose distributions were characterized using dose to the prescription point, percent depth doses, and two‐dimensional isodose curves. Results: Validation between the MC and TPS calculations was successful within 1.5% over a depth of 5.0 cm in water. Negligible dose differences were calculated when assuming the applicator is made completely of water versus modeling all the individual applicator components. Conversely, semi‐infinite phantom geometry had more than 5% loss in dose to the prescription point due to the absence of backscatter. Most severely, curvature radii in the range of 5.4 cm (shallow curvature) to 0.9 cm (steep curvature) had dose differences of 5%–25%, regardless of whether the curvature was along the catheter length or transverse to it. Conclusions: This study quantified the changes in dose due to material and geometric differences that are currently not accounted for by the TPS. While not accounting for the material of the applicator contributes to negligibly, the presence of backscattering material can contribute up to 5%. The radius of the bending of the applicator was found to potentially have the largest impact on the dosimetry of the central plane, with deviations up to 25%.
- 27 November 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 26 (12) , e70386
Open AccessMonte Carlo simulations of geometric deformation of Harrison–Anderson–Mick applicators used in intraoperative radiation therapy
Background: The Harrison–Anderson–Mick (HAM) applicator is a high‐dose‐rate intraoperative radiotherapy (HDR‐IORT) applicator used to position Ir‐192 brachytherapy sources over surgically‐accessed tumor volumes or post‐resection tumor beds. Because of the lack of a 3D imaging system, dwell times are optimized pre‐surgery by a TG‐43–based treatment planning system (TPS) that assumes a perfectly flat applicator surface surrounded by an infinite water phantom. These assumed conditions are disparate from typical treatment conditions, especially in the pelvic regions, which often involve uneven patient surfaces and superficial irradiations with little to no backscatter material. Purpose: Develop and validate a Monte Carlo (MC) model of HDR‐IORT treatment with a HAM applicator and use this validated model to quantify inaccuracies in the dose calculations due to the simplified conditions assumed in the planning process. Methods: The Oncentra Brachy TPS was used to optimize dwell times and calculate the delivered relative dose distribution for a 6‐catheter, 8‐cm HAM applicator with 0.5‐cm dwell steps and 1.0‐cm catheter spacing. A TOPAS (v.3.9) MC model of this treatment was then developed and validated against the TPS dose calculations. Once validated, the TOPAS applicator model was modified to calculate the difference in doses due to changes in backscatter conditions, the incorporation of the actual applicator materials, and curvature of the applicator. Dose distributions were characterized using dose to the prescription point, percent depth doses, and two‐dimensional isodose curves. Results: Validation between the MC and TPS calculations was successful within 1.5% over a depth of 5.0 cm in water. Negligible dose differences were calculated when assuming the applicator is made completely of water versus modeling all the individual applicator components. Conversely, semi‐infinite phantom geometry had more than 5% loss in dose to the prescription point due to the absence of backscatter. Most severely, curvature radii in the range of 5.4 cm (shallow curvature) to 0.9 cm (steep curvature) had dose differences of 5%–25%, regardless of whether the curvature was along the catheter length or transverse to it. Conclusions: This study quantified the changes in dose due to material and geometric differences that are currently not accounted for by the TPS. While not accounting for the material of the applicator contributes to negligibly, the presence of backscattering material can contribute up to 5%. The radius of the bending of the applicator was found to potentially have the largest impact on the dosimetry of the central plane, with deviations up to 25%.
- Open Access
- 31 October 2025
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 15, 1680342
Novel volumetric modulated arc therapy approach for lattice radiation therapy for bulky liver tumors
Purpose: Lattice radiation therapy (LRT) is a type of spatially fractionated radiation therapy that has emerged as an effective treatment approach for bulky solid tumors. RapidArc Dynamic (RAD) is a novel beam delivery approach that may be advantageous for LRT. The purpose of this in silico study was to evaluate and compare a novel RAD-based LRT approach (RAD-LRT) with conventional volumetric modulated arc therapy (VMAT)-based LRT (VMAT-LRT). Methods: Twenty patients with bulky liver tumors treated with RT were retrospectively identified. VMAT-LRT and RAD-LRT plans were generated for all patients. Lattice spheres were placed in a standardized hexagonal pattern with alternating high-dose spheres (vertex tumor volume high [VTVH], analogous to the peak dose) and low-dose control spheres (vertex tumor volume low [VTVL], analogous to the valley dose). Gross tumor volumes (GTVs)3 and GTVs ≥1,000 cm 3 were planned with 1.0-cm-diameter spheres (n=10) and 1.5-cm-diameter sphere (n=10), respectively. A prescription dose of 20 Gy to 80% of the VTVH was utilized. LRT dose metrics (e.g., peak-to-valley dose ratios, VTVH D80, VTVL D mean ) were calculated and were compared using paired Wilcoxon sign-ranked test. Planning efficiency was assessed by evaluating planning structures, planning time, and number of treatment fields. Results: For all 20 cases, RAD-LRT achieved superior plan quality than VMAT-LRT, indicated by similar prescription dose coverage (group mean, VTVH D80: 20.40 Gy for VMAT-LRT, 20.50 Gy for RAD-LRT) but significantly lower valley dose (group mean, VTVL mean dose: 3.40 Gy for VMAT-LRT, 2.20 Gy for RAD-LRT, p<0.0001). Compared to VMAT-LRT, RAD-LRT required fewer planning structures (mean ± SD, 9 ± 1 for VMAT-LRT, 4 ± 1 for RAD-LRT), less planning time (26 ± 8 min for VMAT-LRT, 18 ± 11 min for RAD-LRT), and fewer treatment beams (5 ± 1 arcs for VMAT-LRT, 1 arc with 4 ± 1 static ports for RAD-LRT). RAD-LRT also had significantly higher peak-to-valley dose ratios (group mean, VTVH/VTVL D90 ratio: 8.92 for VMAT-LRT, 18.20 for RAD-LRT, p<0.0001). Conclusion: RAD may offer a unique approach to Lattice RT. RAD-LRT generated high quality plans with notable treatment planning efficiency, allowing for creation of quality plans without extensive planning time and LRT expertise.
- 31 October 2025
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 15, 1680342
Open AccessNovel volumetric modulated arc therapy approach for lattice radiation therapy for bulky liver tumors
Purpose: Lattice radiation therapy (LRT) is a type of spatially fractionated radiation therapy that has emerged as an effective treatment approach for bulky solid tumors. RapidArc Dynamic (RAD) is a novel beam delivery approach that may be advantageous for LRT. The purpose of this in silico study was to evaluate and compare a novel RAD-based LRT approach (RAD-LRT) with conventional volumetric modulated arc therapy (VMAT)-based LRT (VMAT-LRT). Methods: Twenty patients with bulky liver tumors treated with RT were retrospectively identified. VMAT-LRT and RAD-LRT plans were generated for all patients. Lattice spheres were placed in a standardized hexagonal pattern with alternating high-dose spheres (vertex tumor volume high [VTVH], analogous to the peak dose) and low-dose control spheres (vertex tumor volume low [VTVL], analogous to the valley dose). Gross tumor volumes (GTVs)3 and GTVs ≥1,000 cm 3 were planned with 1.0-cm-diameter spheres (n=10) and 1.5-cm-diameter sphere (n=10), respectively. A prescription dose of 20 Gy to 80% of the VTVH was utilized. LRT dose metrics (e.g., peak-to-valley dose ratios, VTVH D80, VTVL D mean ) were calculated and were compared using paired Wilcoxon sign-ranked test. Planning efficiency was assessed by evaluating planning structures, planning time, and number of treatment fields. Results: For all 20 cases, RAD-LRT achieved superior plan quality than VMAT-LRT, indicated by similar prescription dose coverage (group mean, VTVH D80: 20.40 Gy for VMAT-LRT, 20.50 Gy for RAD-LRT) but significantly lower valley dose (group mean, VTVL mean dose: 3.40 Gy for VMAT-LRT, 2.20 Gy for RAD-LRT, p<0.0001). Compared to VMAT-LRT, RAD-LRT required fewer planning structures (mean ± SD, 9 ± 1 for VMAT-LRT, 4 ± 1 for RAD-LRT), less planning time (26 ± 8 min for VMAT-LRT, 18 ± 11 min for RAD-LRT), and fewer treatment beams (5 ± 1 arcs for VMAT-LRT, 1 arc with 4 ± 1 static ports for RAD-LRT). RAD-LRT also had significantly higher peak-to-valley dose ratios (group mean, VTVH/VTVL D90 ratio: 8.92 for VMAT-LRT, 18.20 for RAD-LRT, p<0.0001). Conclusion: RAD may offer a unique approach to Lattice RT. RAD-LRT generated high quality plans with notable treatment planning efficiency, allowing for creation of quality plans without extensive planning time and LRT expertise.
- Open Access
- 23 September 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 36
Multiomic random forest toxicity modeling of radiation esophagitis
- 23 September 2025
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 36
Open AccessMultiomic random forest toxicity modeling of radiation esophagitis
- 2 July 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 210, 111011
Multiomic based Bayesian network toxicity modeling for simultaneous prediction of multiple toxicity outcomes in NSCLC
- 2 July 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 210, 111011
Multiomic based Bayesian network toxicity modeling for simultaneous prediction of multiple toxicity outcomes in NSCLC
- Open Access
Dosimetric Advantage of Scanning Beam Proton Therapy in Gynecologic Patients Receiving Adjuvant Radiotherapy
Background/Objectives: Adjuvant radiation for gynecologic malignancies often exposes organs at risk (OARs), such as the bone marrow, bowel, rectum, and bladder, to radiation, leading to toxicities that impact treatment tolerance and patient quality of life. Scanning proton beam therapy, particularly with Individual Field Simultaneous Optimization (IFSO), may offer dosimetric and biological advantages over volumetric modulated arc therapy (VMAT). This study evaluates the clinical impact of IFSO-based proton planning in post-operative gynecologic cancer patients. Materials and Methods: Fourteen patients receiving adjuvant proton therapy to 45 Gy in 25 fractions were retrospectively analyzed. Comparison VMAT plans were generated on the same datasets. Dose–volume metrics for key OARs and normal tissue complication probabilities (NTCPs) were compared using paired statistical tests. Robustness evaluations accounted for setup and range uncertainties. Results: Proton plans significantly reduced dose to bone marrow (V10Gy: 58% vs. 86%, p < 0.00001; V20Gy: 47% vs. 58%, p < 0.00001), small bowel (V20Gy: 21% vs. 56%, p < 0.00001), and femoral heads (left femoral head mean: 11Gy vs. 13Gy, p = 0.032; right femoral head mean: 11Gy vs. 13Gy, p = 0.022). NTCP modeling predicted significantly lower rates of bowel urgency (9.4% vs. 3.3%, p < 0.001) and hematologic toxicity (10.2% vs. 4.9%, p < 0.001) with proton therapy. Plans remained robust across uncertainty scenarios. Conclusions: IFSO-based scanning proton therapy provides clinically meaningful sparing of bone marrow and bowel, with the potential to reduce hematologic and gastrointestinal toxicities. These findings support its use in patients receiving adjuvant pelvic radiotherapy, particularly those undergoing extended field treatment or chemotherapy.
Open AccessDosimetric Advantage of Scanning Beam Proton Therapy in Gynecologic Patients Receiving Adjuvant Radiotherapy
Background/Objectives: Adjuvant radiation for gynecologic malignancies often exposes organs at risk (OARs), such as the bone marrow, bowel, rectum, and bladder, to radiation, leading to toxicities that impact treatment tolerance and patient quality of life. Scanning proton beam therapy, particularly with Individual Field Simultaneous Optimization (IFSO), may offer dosimetric and biological advantages over volumetric modulated arc therapy (VMAT). This study evaluates the clinical impact of IFSO-based proton planning in post-operative gynecologic cancer patients. Materials and Methods: Fourteen patients receiving adjuvant proton therapy to 45 Gy in 25 fractions were retrospectively analyzed. Comparison VMAT plans were generated on the same datasets. Dose–volume metrics for key OARs and normal tissue complication probabilities (NTCPs) were compared using paired statistical tests. Robustness evaluations accounted for setup and range uncertainties. Results: Proton plans significantly reduced dose to bone marrow (V10Gy: 58% vs. 86%, p < 0.00001; V20Gy: 47% vs. 58%, p < 0.00001), small bowel (V20Gy: 21% vs. 56%, p < 0.00001), and femoral heads (left femoral head mean: 11Gy vs. 13Gy, p = 0.032; right femoral head mean: 11Gy vs. 13Gy, p = 0.022). NTCP modeling predicted significantly lower rates of bowel urgency (9.4% vs. 3.3%, p < 0.001) and hematologic toxicity (10.2% vs. 4.9%, p < 0.001) with proton therapy. Plans remained robust across uncertainty scenarios. Conclusions: IFSO-based scanning proton therapy provides clinically meaningful sparing of bone marrow and bowel, with the potential to reduce hematologic and gastrointestinal toxicities. These findings support its use in patients receiving adjuvant pelvic radiotherapy, particularly those undergoing extended field treatment or chemotherapy.
- Open Access
- 18 December 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (24) , 2851
Comparison of Vendor-Pretrained and Custom-Trained Deep Learning Segmentation Models for Head-and-Neck, Breast, and Prostate Cancers
Background/Objectives: We assessed the influence of local patients and clinical characteristics on the performance of commercial deep learning (DL) segmentation models for head-and-neck (HN), breast, and prostate cancers. Methods: Clinical computed tomography (CT) scans and clinically approved contours of 210 patients (53 HN, 49 left breast, 55 right breast, and 53 prostate cancer) were used to train and validate segmentation models integrated within a vendor-supplied DL training toolkit and to assess the performance of both vendor-pretrained and custom-trained models. Four custom models (HN, left breast, right breast, and prostate) were trained and validated with 30 (training)/5 (validation) HN, 34/5 left breast, 39/5 right breast, and 30/5 prostate patients to auto-segment a total of 24 organs at risk (OARs). Subsequently, both vendor-pretrained and custom-trained models were tested on the remaining patients from each group. Auto-segmented contours were evaluated by comparing them with clinically approved contours via the Dice similarity coefficient (DSC) and mean surface distance (MSD). The performance of the left and right breast models was assessed jointly according to ipsilateral/contralateral locations. Results: The average DSCs for all structures in vendor-pretrained and custom-trained models were as follows: 0.81 ± 0.12 and 0.86 ± 0.11 in HN; 0.67 ± 0.16 and 0.80 ± 0.11 in the breast; and 0.87 ± 0.09 and 0.92 ± 0.06 in the prostate. The corresponding average MSDs were 0.81 ± 0.76 mm and 0.76 ± 0.56 mm (HN), 4.85 ± 2.44 mm and 2.42 ± 1.49 mm (breast), and 2.17 ± 1.39 mm and 1.21 ± 1.00 mm (prostate). Notably, custom-trained models showed significant improvements over vendor-pretrained models for 14 of 24 OARs, reflecting the influence of data/contouring variations in segmentation performance. Conclusions: These findings underscore the substantial impact of institutional preferences and clinical practices on the implementation of vendor-pretrained models. We also found that a relatively small amount of institutional data was sufficient to train customized segmentation models with sufficient accuracy.
- 18 December 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (24) , 2851
Open AccessComparison of Vendor-Pretrained and Custom-Trained Deep Learning Segmentation Models for Head-and-Neck, Breast, and Prostate Cancers
Background/Objectives: We assessed the influence of local patients and clinical characteristics on the performance of commercial deep learning (DL) segmentation models for head-and-neck (HN), breast, and prostate cancers. Methods: Clinical computed tomography (CT) scans and clinically approved contours of 210 patients (53 HN, 49 left breast, 55 right breast, and 53 prostate cancer) were used to train and validate segmentation models integrated within a vendor-supplied DL training toolkit and to assess the performance of both vendor-pretrained and custom-trained models. Four custom models (HN, left breast, right breast, and prostate) were trained and validated with 30 (training)/5 (validation) HN, 34/5 left breast, 39/5 right breast, and 30/5 prostate patients to auto-segment a total of 24 organs at risk (OARs). Subsequently, both vendor-pretrained and custom-trained models were tested on the remaining patients from each group. Auto-segmented contours were evaluated by comparing them with clinically approved contours via the Dice similarity coefficient (DSC) and mean surface distance (MSD). The performance of the left and right breast models was assessed jointly according to ipsilateral/contralateral locations. Results: The average DSCs for all structures in vendor-pretrained and custom-trained models were as follows: 0.81 ± 0.12 and 0.86 ± 0.11 in HN; 0.67 ± 0.16 and 0.80 ± 0.11 in the breast; and 0.87 ± 0.09 and 0.92 ± 0.06 in the prostate. The corresponding average MSDs were 0.81 ± 0.76 mm and 0.76 ± 0.56 mm (HN), 4.85 ± 2.44 mm and 2.42 ± 1.49 mm (breast), and 2.17 ± 1.39 mm and 1.21 ± 1.00 mm (prostate). Notably, custom-trained models showed significant improvements over vendor-pretrained models for 14 of 24 OARs, reflecting the influence of data/contouring variations in segmentation performance. Conclusions: These findings underscore the substantial impact of institutional preferences and clinical practices on the implementation of vendor-pretrained models. We also found that a relatively small amount of institutional data was sufficient to train customized segmentation models with sufficient accuracy.
- Open Access
Daily Diagnostic Quality Computed Tomography-on-Rails (CTOR) Image Guidance for Abdominal Stereotactic Body Radiation Therapy (SBRT)
Background/Objectives: Stereotactic body radiation therapy (SBRT) for abdominal targets faces a variety of challenges, including motion caused by the respiration and digestion and a relatively poor level of contrast between the tumor and the surrounding tissues. Breath-hold treatments with computed tomography-on-rails (CTOR) image guidance is one way of addressing these challenges, allowing for both the tumor and normal tissues to be well-visualized. Using isodose lines (IDLs) from CT simulations as a guide, the anatomical information can be used to shift the alignment or trigger a replan, such that normal tissues receive acceptable doses of radiation. Methods: This study aims to describe the workflow involved when using CTOR for pancreas and liver SBRT and demonstrates its effectiveness through several case studies. Results: In these case studies, using the anatomical information gained through diagnostic-quality CT guidance to make slight adjustments to the alignment, resulted in reductions in the maximum dose to the stomach. Conclusions: High-quality imaging, such as CTOR, and the use of IDLs to estimate the doses to OARs, enable the safe delivery of SBRT, without the added complexity and resource commitment required by daily online adaptive planning.
Open AccessDaily Diagnostic Quality Computed Tomography-on-Rails (CTOR) Image Guidance for Abdominal Stereotactic Body Radiation Therapy (SBRT)
Background/Objectives: Stereotactic body radiation therapy (SBRT) for abdominal targets faces a variety of challenges, including motion caused by the respiration and digestion and a relatively poor level of contrast between the tumor and the surrounding tissues. Breath-hold treatments with computed tomography-on-rails (CTOR) image guidance is one way of addressing these challenges, allowing for both the tumor and normal tissues to be well-visualized. Using isodose lines (IDLs) from CT simulations as a guide, the anatomical information can be used to shift the alignment or trigger a replan, such that normal tissues receive acceptable doses of radiation. Methods: This study aims to describe the workflow involved when using CTOR for pancreas and liver SBRT and demonstrates its effectiveness through several case studies. Results: In these case studies, using the anatomical information gained through diagnostic-quality CT guidance to make slight adjustments to the alignment, resulted in reductions in the maximum dose to the stomach. Conclusions: High-quality imaging, such as CTOR, and the use of IDLs to estimate the doses to OARs, enable the safe delivery of SBRT, without the added complexity and resource commitment required by daily online adaptive planning.
- Open Access
Performance comparison of ten state-of-the-art machine learning algorithms for outcome prediction modeling of radiation-induced toxicity
Purpose: To evaluate the efficacy of prominent machine learning algorithms in predicting normal tissue complication probability utilizing clinical data obtained from two distinct disease sites, and to create a software tool that facilitates the automatic determination of the optimal algorithm to model any given labeled dataset. Methods and Materials: We obtained 3 sets of radiation toxicity data (478 patients) from our clinic, gastrointestinal toxicity (GIT), radiation pneumonitis (RP), and radiation esophagitis (RE). These data comprised clinicopathological and dosimetric information for patients diagnosed with non-small cell lung cancer and anal squamous cell carcinoma. Each dataset was modeled using ten commonly employed machine learning algorithms (elastic net, LASSO, random forest, regression forest, support vector machine, XGBoost, k-nearest- neighbors, neural network, Bayesian-LASSO, and Bayesian neural network) by randomly dividing the dataset into a training and test set. The training set was used to create and tune the model, and the test set served to assess it by calculating performance metrics. This process was repeated 100 times by each algorithm for each dataset. Figures were generated to visually compare the performance of the algorithms. A graphical user interface was developed to automate this whole process. Results: LASSO achieved the highest area under the precision-recall curve (AUPRC) (0.807±0.067) for RE, random forest for GIT (0.726±0.096), and the neural network for RP (0.878±0.060). Area-under-the-curve was 0.754±0.069, 0.889±0.043, and 0.905±0.045, respectively. The graphical user interface was used to compare all algorithms for each dataset automatically. When averaging AUPRC across all toxicities, Bayesian-LASSO was the best model. Conclusion: Our results show that there is no best algorithm for all datasets. Therefore, it is important to compare multiple algorithms when training an outcome prediction model on a new dataset. The graphical user interface created for this study automatically compares the performance of these ten algorithms for any dataset.
Open AccessPerformance comparison of ten state-of-the-art machine learning algorithms for outcome prediction modeling of radiation-induced toxicity
Purpose: To evaluate the efficacy of prominent machine learning algorithms in predicting normal tissue complication probability utilizing clinical data obtained from two distinct disease sites, and to create a software tool that facilitates the automatic determination of the optimal algorithm to model any given labeled dataset. Methods and Materials: We obtained 3 sets of radiation toxicity data (478 patients) from our clinic, gastrointestinal toxicity (GIT), radiation pneumonitis (RP), and radiation esophagitis (RE). These data comprised clinicopathological and dosimetric information for patients diagnosed with non-small cell lung cancer and anal squamous cell carcinoma. Each dataset was modeled using ten commonly employed machine learning algorithms (elastic net, LASSO, random forest, regression forest, support vector machine, XGBoost, k-nearest- neighbors, neural network, Bayesian-LASSO, and Bayesian neural network) by randomly dividing the dataset into a training and test set. The training set was used to create and tune the model, and the test set served to assess it by calculating performance metrics. This process was repeated 100 times by each algorithm for each dataset. Figures were generated to visually compare the performance of the algorithms. A graphical user interface was developed to automate this whole process. Results: LASSO achieved the highest area under the precision-recall curve (AUPRC) (0.807±0.067) for RE, random forest for GIT (0.726±0.096), and the neural network for RP (0.878±0.060). Area-under-the-curve was 0.754±0.069, 0.889±0.043, and 0.905±0.045, respectively. The graphical user interface was used to compare all algorithms for each dataset automatically. When averaging AUPRC across all toxicities, Bayesian-LASSO was the best model. Conclusion: Our results show that there is no best algorithm for all datasets. Therefore, it is important to compare multiple algorithms when training an outcome prediction model on a new dataset. The graphical user interface created for this study automatically compares the performance of these ten algorithms for any dataset.