Anton Arndt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Anton Arndt has a total of 118 co-authors. Here are the top co-authors by number of shared publications:
A. Lundberg
7 shared publicationsArne Lundberg
Karolinska Institute , Stockholm , Sweden
3 shared publicationsI. Ekenman
3 shared publications- Olga Tarassova
The Swedish School of Sport and Health Sciences
3 shared publications P. Westblad
3 shared publications- Aharon S. Finestone
Gray Faculty of Medical & Health Sciences, Tel Aviv University, Tel Aviv 6997801, Israel
2 shared publications
Latest Publications
- Open Access
- 12 October 2026
- Published by Wiley in European Journal of Sport Science
- Vol. 26 (11) , e70266
Advanced Footwear Technology in Distance Running: What We Know, What We Don't Know, and Future Directions
Over the past decade, running shoes have undergone substantial innovation with the emergence of Advanced Footwear Technology (AFT). Shoes with AFT are typically characterized by highly compliant (deformable) and resilient (high energy return) midsole foams, embedded curved stiffening elements, low mass, and a rockered longitudinal geometry. This expert statement aims to synthesize established knowledge, remaining uncertainties and key directions for future research on AFT in middle‐ and long‐distance running. Current literature demonstrates robust improvements in running economy and performance with AFT, with reported metabolic savings of approximately 2%–4%, and corresponding performance improvements of 1%–3%. These benefits likely arise from a combination of “acute” and possibly “long‐term” mechanisms. Proposed acute mechanisms include decreased muscle force production due to higher positive work from energy‐returning foams, lower muscle force production to accommodate mechanical running demands due to compliant midsoles, and improved mechanical efficiency associated with greater longitudinal bending stiffness and curved geometry. Importantly, AFT features have a synergistic effect, with the relative importance of each mechanism differing depending on the context. Emerging evidence also suggests potential reductions in muscle damage/inflammation and soreness, which could support better physiological resilience, and higher training volumes/quality. From a biomechanical injury risk perspective, AFT can redistribute loading, potentially increasing metatarsal and tarsal stress while reducing tibia and possibly Achilles tendon loading. However, injury risk associated with AFT use remains equivocal, with limited high‐quality data. Notably, substantial inter‐individual variability has been observed, influencing both running economy and potential injury risk although the determinants of this variability remain unclear.
- 12 October 2026
- Published by Wiley in European Journal of Sport Science
- Vol. 26 (11) , e70266
Open AccessAdvanced Footwear Technology in Distance Running: What We Know, What We Don't Know, and Future Directions
Over the past decade, running shoes have undergone substantial innovation with the emergence of Advanced Footwear Technology (AFT). Shoes with AFT are typically characterized by highly compliant (deformable) and resilient (high energy return) midsole foams, embedded curved stiffening elements, low mass, and a rockered longitudinal geometry. This expert statement aims to synthesize established knowledge, remaining uncertainties and key directions for future research on AFT in middle‐ and long‐distance running. Current literature demonstrates robust improvements in running economy and performance with AFT, with reported metabolic savings of approximately 2%–4%, and corresponding performance improvements of 1%–3%. These benefits likely arise from a combination of “acute” and possibly “long‐term” mechanisms. Proposed acute mechanisms include decreased muscle force production due to higher positive work from energy‐returning foams, lower muscle force production to accommodate mechanical running demands due to compliant midsoles, and improved mechanical efficiency associated with greater longitudinal bending stiffness and curved geometry. Importantly, AFT features have a synergistic effect, with the relative importance of each mechanism differing depending on the context. Emerging evidence also suggests potential reductions in muscle damage/inflammation and soreness, which could support better physiological resilience, and higher training volumes/quality. From a biomechanical injury risk perspective, AFT can redistribute loading, potentially increasing metatarsal and tarsal stress while reducing tibia and possibly Achilles tendon loading. However, injury risk associated with AFT use remains equivocal, with limited high‐quality data. Notably, substantial inter‐individual variability has been observed, influencing both running economy and potential injury risk although the determinants of this variability remain unclear.
- 3 October 2026
- Published by Elsevier in Physical Therapy in Sport
- Vol. 82
Sex- and age-specific normative values for lower-limb field tests in elite TeamGym gymnasts
- 3 October 2026
- Published by Elsevier in Physical Therapy in Sport
- Vol. 82
Sex- and age-specific normative values for lower-limb field tests in elite TeamGym gymnasts
- 15 September 2026
- Published by Elsevier in Annals of Anatomy - Anatomischer Anzeiger
- Vol. 269
Anatomical-histological study of the Achilles tendon: The search for subtendons
- 15 September 2026
- Published by Elsevier in Annals of Anatomy - Anatomischer Anzeiger
- Vol. 269
Anatomical-histological study of the Achilles tendon: The search for subtendons
- Open Access
- 20 March 2026
- Published by Wolters Kluwer Health in American Journal of Physical Medicine & Rehabilitation
- Vol. 105 (12) , 1173-1180
Para-cycling Classification in the Bicycle and Tricycle Divisions
Objective: The current classification system in para-cycling needs to be investigated to comply with the requirements of the International Paralympic Committee (IPC) to provide evidence-based classification in all Paralympic sports. The aim was to investigate consensus on issues within the current para-cycling classification system and identify future research priorities within para-cycling classification. Design: Three rounds of online questionnaires were sent to an international expert panel (n=51, representing 6 continents) consisting of para-cyclists (n=27, 52.9%), para-cycling coaches and team managers (n=5, 9.8%), classifiers (n=8, 15.7%), para-sport researchers (n=5, 9.8%), and other roles in para-cycling (n=6, 11.7%). Each new round was based on the responses of the previous round. Results: Consensus was reached on the following main issues: adjust current muscle strength assessment in classification (76%), redefine the minimum impairment criteria for the lower (97%) and upper (76%) body, athletes cycling with one leg should compete separately from athletes cycling with two legs (81%), athletes with musculoskeletal impairments should compete separately from athletes with coordination impairments (77%). Conclusions: The panel’s views revealed directions to revise the para-cycling classification system, and that future para-cycling research should focus on leg muscle strength assessments, upper-body impairments, and the cut-off between bicycling and tricycling (C- and T-divisions).
- 20 March 2026
- Published by Wolters Kluwer Health in American Journal of Physical Medicine & Rehabilitation
- Vol. 105 (12) , 1173-1180
Open AccessPara-cycling Classification in the Bicycle and Tricycle Divisions
Objective: The current classification system in para-cycling needs to be investigated to comply with the requirements of the International Paralympic Committee (IPC) to provide evidence-based classification in all Paralympic sports. The aim was to investigate consensus on issues within the current para-cycling classification system and identify future research priorities within para-cycling classification. Design: Three rounds of online questionnaires were sent to an international expert panel (n=51, representing 6 continents) consisting of para-cyclists (n=27, 52.9%), para-cycling coaches and team managers (n=5, 9.8%), classifiers (n=8, 15.7%), para-sport researchers (n=5, 9.8%), and other roles in para-cycling (n=6, 11.7%). Each new round was based on the responses of the previous round. Results: Consensus was reached on the following main issues: adjust current muscle strength assessment in classification (76%), redefine the minimum impairment criteria for the lower (97%) and upper (76%) body, athletes cycling with one leg should compete separately from athletes cycling with two legs (81%), athletes with musculoskeletal impairments should compete separately from athletes with coordination impairments (77%). Conclusions: The panel’s views revealed directions to revise the para-cycling classification system, and that future para-cycling research should focus on leg muscle strength assessments, upper-body impairments, and the cut-off between bicycling and tricycling (C- and T-divisions).
- Open Access
- 16 September 2024
- Published by Taylor & Francis in Sports Biomechanics
- Vol. 25 (1) , 1-21
Assessing lower extremity stiffness in countermovement jumps: a critical analysis of the differences between calculation methods
Stiffness (k) describes a material's resistance to deformation and is useful for understanding neuromuscular function, performance, and injury risk. The aim of this study is to compare the lower limb stiffness method (kLLS), which uses only force plate data, with methods combining force plate and motion capture data to calculate stiffness during the eccentric phase of a countermovement. Twelve resistance-trained males: age 24.9 (4.4) years, height 1.81 (0.05) m, weight 88.2 (14) kg) performed three maximal effort countermovement jumps (CMJ). Data were collected synchronously using three-dimensional (3D) kinematic and kinetic data (dual force plate setup). Lower limb stiffness (z), joint stiffness (x, y, and z), and leg stiffness (linear, sagittal plane, and 3D) were calculated for the eccentric phase of all CMs. kLLS showed high concurrent validity with strong correlations to kinetic-kinematic methods (r = 0.90-0.97, p < 0.05). A linear mixed model revealed no significant differences in k-values between kLLS and leg stiffness, indicating high concurrent validity. kLLS offers valid and valuable information affecting performance, injury risk, and return-to-sport decisions. The findings suggest that kLLS is a valid method for calculating stiffness in CMJs and equal to 3D leg stiffness.
- 16 September 2024
- Published by Taylor & Francis in Sports Biomechanics
- Vol. 25 (1) , 1-21
Open AccessAssessing lower extremity stiffness in countermovement jumps: a critical analysis of the differences between calculation methods
Stiffness (k) describes a material's resistance to deformation and is useful for understanding neuromuscular function, performance, and injury risk. The aim of this study is to compare the lower limb stiffness method (kLLS), which uses only force plate data, with methods combining force plate and motion capture data to calculate stiffness during the eccentric phase of a countermovement. Twelve resistance-trained males: age 24.9 (4.4) years, height 1.81 (0.05) m, weight 88.2 (14) kg) performed three maximal effort countermovement jumps (CMJ). Data were collected synchronously using three-dimensional (3D) kinematic and kinetic data (dual force plate setup). Lower limb stiffness (z), joint stiffness (x, y, and z), and leg stiffness (linear, sagittal plane, and 3D) were calculated for the eccentric phase of all CMs. kLLS showed high concurrent validity with strong correlations to kinetic-kinematic methods (r = 0.90-0.97, p < 0.05). A linear mixed model revealed no significant differences in k-values between kLLS and leg stiffness, indicating high concurrent validity. kLLS offers valid and valuable information affecting performance, injury risk, and return-to-sport decisions. The findings suggest that kLLS is a valid method for calculating stiffness in CMJs and equal to 3D leg stiffness.
- Open Access
- 17 May 2022
- Published by Taylor & Francis in Sports Biomechanics
- Vol. 24 (10) , 2799-2820
Comparison of lightweight and traditional figure skating blades, a prototype blade with integrated damping system and a running shoe in simulated figure skating landings and vertical countermovement jumps, and evaluation of dampening properties of the prototype blade
To date, there is no empirical evidence suggesting greater jump heights or cushioned landings when using figure skating (FS) blades of different mass and design. This study examined the effect of lightweight (Gold Seal Revolution from John Wilson) and traditional (Apex Supreme from Jackson Ultima and Volant from Riedell) blades, a new prototype blade with an integrated damping system (damping blade) in two different damping configurations, and running shoes (Runfalcon from Adidas) on kinetics and kinematics during simulated on-ice landings from 0.6 m and maximal countermovement jumps on synthetic ice, and measured dampening properties of the damping blade. Seventeen participants executed trials in the six footwear conditions blinded to the different blades and acted as their own control for statistical comparison. There were no differences between the lightweight and traditional blades on the maximal vertical ground reaction force during the landing. Image analysis showed a damping effect in the damping blade that significantly decreased the landing load for all participants (mean 4.38 ± 0.68 bodyweight) (p ≤ 0.006), on average between 10.1 and 14.3% compared to lightweight and traditional blades (4.87 ± 1.01 to 5.11 ± 0.88 bodyweight). The maximal jump height achieved was the same in all FS blades.
- 17 May 2022
- Published by Taylor & Francis in Sports Biomechanics
- Vol. 24 (10) , 2799-2820
Open AccessComparison of lightweight and traditional figure skating blades, a prototype blade with integrated damping system and a running shoe in simulated figure skating landings and vertical countermovement jumps, and evaluation of dampening properties of the prototype blade
To date, there is no empirical evidence suggesting greater jump heights or cushioned landings when using figure skating (FS) blades of different mass and design. This study examined the effect of lightweight (Gold Seal Revolution from John Wilson) and traditional (Apex Supreme from Jackson Ultima and Volant from Riedell) blades, a new prototype blade with an integrated damping system (damping blade) in two different damping configurations, and running shoes (Runfalcon from Adidas) on kinetics and kinematics during simulated on-ice landings from 0.6 m and maximal countermovement jumps on synthetic ice, and measured dampening properties of the damping blade. Seventeen participants executed trials in the six footwear conditions blinded to the different blades and acted as their own control for statistical comparison. There were no differences between the lightweight and traditional blades on the maximal vertical ground reaction force during the landing. Image analysis showed a damping effect in the damping blade that significantly decreased the landing load for all participants (mean 4.38 ± 0.68 bodyweight) (p ≤ 0.006), on average between 10.1 and 14.3% compared to lightweight and traditional blades (4.87 ± 1.01 to 5.11 ± 0.88 bodyweight). The maximal jump height achieved was the same in all FS blades.
- Open Access
- 27 April 2022
- Published by Taylor & Francis in Sports Biomechanics
- Vol. 24 (10) , 2821-2835
Kinematic and kinetic performance variables during paddling among para-kayak athletes with unilateral above or below knee amputation
In para-kayak, athletes with unilateral above knee amputation (AK) and athletes with below knee amputation (BK) compete in the same class. This has been questioned since previous research have shown that the legs are important for paddling performance. The purpose was therefore to examine differences in kinematic and kinetic performance variables between AK and BK para-kayak athletes and the amputated (A) and non-amputated (NA) sides. Eleven AK and six BK athletes on international level participated. 3D kinematic and kinetic data were collected for the body, seat, footrest and paddle during kayak ergometer paddling. There were no significant differences between the groups in main performance variables such as power output or paddle force. Differences between the groups were only seen in the hip joint in flexion range of motion, flexion and extension angular velocity and flexion moment where BK demonstrated larger values. The NA side demonstrated greater values compared to the A side in posterior force at the seat and in hip flexion moment. As there were no significant differences between the groups in the majority of the examined key performance variables, the results suggest that athletes with unilateral AK and BK amputation may be able to compete in the same class.
- 27 April 2022
- Published by Taylor & Francis in Sports Biomechanics
- Vol. 24 (10) , 2821-2835
Open AccessKinematic and kinetic performance variables during paddling among para-kayak athletes with unilateral above or below knee amputation
In para-kayak, athletes with unilateral above knee amputation (AK) and athletes with below knee amputation (BK) compete in the same class. This has been questioned since previous research have shown that the legs are important for paddling performance. The purpose was therefore to examine differences in kinematic and kinetic performance variables between AK and BK para-kayak athletes and the amputated (A) and non-amputated (NA) sides. Eleven AK and six BK athletes on international level participated. 3D kinematic and kinetic data were collected for the body, seat, footrest and paddle during kayak ergometer paddling. There were no significant differences between the groups in main performance variables such as power output or paddle force. Differences between the groups were only seen in the hip joint in flexion range of motion, flexion and extension angular velocity and flexion moment where BK demonstrated larger values. The NA side demonstrated greater values compared to the A side in posterior force at the seat and in hip flexion moment. As there were no significant differences between the groups in the majority of the examined key performance variables, the results suggest that athletes with unilateral AK and BK amputation may be able to compete in the same class.
- Open Access
- 1 October 2021
- Published by Elsevier in Gait & Posture
- Vol. 90, 489-495
Extraction of gait parameters from marker-free video recordings of Timed Up-and-Go tests: Validity, inter- and intra-rater reliability
- 1 October 2021
- Published by Elsevier in Gait & Posture
- Vol. 90, 489-495
Open AccessExtraction of gait parameters from marker-free video recordings of Timed Up-and-Go tests: Validity, inter- and intra-rater reliability
- 1 August 2021
- Published by Elsevier in Journal of Biomechanics
- Vol. 125, 110581
ISB recommendations for skin-marker-based multi-segment foot kinematics
- 1 August 2021
- Published by Elsevier in Journal of Biomechanics
- Vol. 125, 110581
ISB recommendations for skin-marker-based multi-segment foot kinematics
- Open Access
- 1 January 2021
- Published by Wiley in BioMed Research International
- Vol. 2021 (1)
Passive Mechanical Properties of Human Medial Gastrocnemius and Soleus Musculotendinous Unit
The in vivo characterization of the passive mechanical properties of the human triceps surae musculotendinous unit is important for gaining a deeper understanding of the interactive responses of the tendon and muscle tissues to loading during passive stretching. This study sought to quantify a comprehensive set of passive muscle‐tendon properties such as slack length, stiffness, and the stress‐strain relationship using a combination of ultrasound imaging and a three‐dimensional motion capture system in healthy adults. By measuring tendon length, the cross‐section areas of the Achilles tendon subcompartments (i.e., medial gastrocnemius and soleus aspects), and the ankle torque simultaneously, the mechanical properties of each individual compartment can be specifically identified. We found that the medial gastrocnemius (GM) and soleus (SOL) aspects of the Achilles tendon have similar mechanical properties in terms of slack angle (GM: −10.96° ± 3.48°; SOL: −8.50° ± 4.03°), moment arm at 0° of ankle angle (GM: 30.35 ± 6.42 mm; SOL: 31.39 ± 6.42 mm), and stiffness (GM: 23.18 ± 13.46 Nmm-1; SOL: 31.57 ± 13.26 Nmm-1). However, maximal tendon stress in the GM was significantly less than that in SOL (GM: 2.96 ± 1.50 MPa; SOL: 4.90 ± 1.88 MPa, p = 0.024), largely due to the higher passive force observed in the soleus compartment (GM: 99.89 ± 39.50 N; SOL: 174.59 ± 79.54 N, p = 0.020). Moreover, the tendon contributed to more than half of the total muscle‐tendon unit lengthening during the passive stretch. This unequal passive stress between the medial gastrocnemius and the soleus tendon might contribute to the asymmetrical loading and deformation of the Achilles tendon during motion reported in the literature. Such information is relevant to understanding the Achilles tendon function and loading profile in pathological populations in the future.
- 1 January 2021
- Published by Wiley in BioMed Research International
- Vol. 2021 (1)
Open AccessPassive Mechanical Properties of Human Medial Gastrocnemius and Soleus Musculotendinous Unit
The in vivo characterization of the passive mechanical properties of the human triceps surae musculotendinous unit is important for gaining a deeper understanding of the interactive responses of the tendon and muscle tissues to loading during passive stretching. This study sought to quantify a comprehensive set of passive muscle‐tendon properties such as slack length, stiffness, and the stress‐strain relationship using a combination of ultrasound imaging and a three‐dimensional motion capture system in healthy adults. By measuring tendon length, the cross‐section areas of the Achilles tendon subcompartments (i.e., medial gastrocnemius and soleus aspects), and the ankle torque simultaneously, the mechanical properties of each individual compartment can be specifically identified. We found that the medial gastrocnemius (GM) and soleus (SOL) aspects of the Achilles tendon have similar mechanical properties in terms of slack angle (GM: −10.96° ± 3.48°; SOL: −8.50° ± 4.03°), moment arm at 0° of ankle angle (GM: 30.35 ± 6.42 mm; SOL: 31.39 ± 6.42 mm), and stiffness (GM: 23.18 ± 13.46 Nmm-1; SOL: 31.57 ± 13.26 Nmm-1). However, maximal tendon stress in the GM was significantly less than that in SOL (GM: 2.96 ± 1.50 MPa; SOL: 4.90 ± 1.88 MPa, p = 0.024), largely due to the higher passive force observed in the soleus compartment (GM: 99.89 ± 39.50 N; SOL: 174.59 ± 79.54 N, p = 0.020). Moreover, the tendon contributed to more than half of the total muscle‐tendon unit lengthening during the passive stretch. This unequal passive stress between the medial gastrocnemius and the soleus tendon might contribute to the asymmetrical loading and deformation of the Achilles tendon during motion reported in the literature. Such information is relevant to understanding the Achilles tendon function and loading profile in pathological populations in the future.