Zhimin Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Zhimin Wang has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Hui-Min Gao
State Key Laboratory for Quality Ensurance and Sustainable Use of Dao-di Herbs, Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing 100700, China
22 shared publications Qiwei Zhang
16 shared publicationsMin Li
Institute of High Energy Physics, Beijing, China
11 shared publications- Wei-Li Zhong
Institute of High Energy Physics, Beijing
11 shared publications - Chang-Gen Yang
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
10 shared publications Changgen Yang
Institute of High Energy Physics, Beijing, China
9 shared publications
Latest Publications
- Open Access
- 18 July 2026
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 141 (7) , 834
Correction: PMT charge uncertainty with artificial correlated pulses
- 18 July 2026
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 141 (7) , 834
Open AccessCorrection: PMT charge uncertainty with artificial correlated pulses
- 15 March 2026
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 10 (5) , 1073-1085
Non-cyclic prototype of JUNO-TAO VETO water tank with 3-inch PMTs
- 15 March 2026
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 10 (5) , 1073-1085
Non-cyclic prototype of JUNO-TAO VETO water tank with 3-inch PMTs
- 9 January 2026
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 10 (5) , 944-955
Comparison of waveform analysis using fast Fourier transform and moving average for 20-inch PMT
- 9 January 2026
- Published by Springer Nature in Radiation Detection Technology and Methods
- Vol. 10 (5) , 944-955
Comparison of waveform analysis using fast Fourier transform and moving average for 20-inch PMT
- Open Access
- 1 December 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (12) , P12013
JUNO 20-inch PMT and electronics system characterization using large pulses of PMT dark counts at the Pan-Asia testing platform
The main goal of the JUNO experiment is to determine the neutrino mass ordering with a 20 kt liquid-scintillator detector. The 20-inch PMT and its 1F3 (one for three) electronics are crucial to realize the excellent energy resolution of at least 3% at 1 MeV. The knowledge on the PMT and 1F3 electronics response is critical for detector performance understanding. A study of the JUNO 20-inch PMT and 1F3 electronics system characterization is presented using large pulses of PMT dark count at the Pan-Asia testing platform in China. Thanks to its broad amplitude range and high rate, the large pulse signals are also used to investigate the PMT after pulse response.
- 1 December 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (12) , P12013
Open AccessJUNO 20-inch PMT and electronics system characterization using large pulses of PMT dark counts at the Pan-Asia testing platform
The main goal of the JUNO experiment is to determine the neutrino mass ordering with a 20 kt liquid-scintillator detector. The 20-inch PMT and its 1F3 (one for three) electronics are crucial to realize the excellent energy resolution of at least 3% at 1 MeV. The knowledge on the PMT and 1F3 electronics response is critical for detector performance understanding. A study of the JUNO 20-inch PMT and 1F3 electronics system characterization is presented using large pulses of PMT dark count at the Pan-Asia testing platform in China. Thanks to its broad amplitude range and high rate, the large pulse signals are also used to investigate the PMT after pulse response.
- 1 September 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (09) , P09007
Dark count rate stability of JUNO 20-inch PMTs in mass testing
The Jiangmen Underground Neutrino Observatory (JUNO) is an ambitious multipurpose neutrino experiment designed to determine the neutrino mass ordering, with an impressive energy resolution goal of at least 3% at 1 MeV. To achieve a photon detection coverage of approximately 75%, JUNO will utilize two types of 20-inch photomultiplier tubes (PMTs): the large PMT (LPMT) and the microchannel plate PMT (MCP-PMT). A significant concern in high-precision neutrino measurements is the dark count rate (DCR) of PMTs, which introduces noise that can adversely affect energy measurement accuracy. During the mass testing phase of the JUNO 20-inch PMTs, comprehensive measurements of the DCR were undertaken. These measurements not only captured the DCR values of individual PMTs but also examined the stability and temperature dependence of the DCR at an operating gain of (1 × 107). This paper presents a detailed characterization of the DCR of the JUNO 20-inch PMTs, investigating factors such as cooling time, temperature variations, and long-term stability using the JUNO Pan-Asia PMT testing facilities. The results reveal distinct DCR characteristics between the two types of PMTs, providing valuable insights into the nature of DCR and its implications for JUNO's scientific objectives. In addition to performance characterization, we implemented a monitoring system to track DCR stability over time. Notably, several spikes in DCR were identified, prompting a preliminary investigation into their causes. Potential factors contributing to these spikes, such as flasher events, were explored using coincidence rate analysis and complementary imaging techniques. The findings from this study are crucial for optimizing the performance of PMTs in JUNO, ultimately aiding the experiment in achieving its goals related to neutrino physics.
- 1 September 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (09) , P09007
Dark count rate stability of JUNO 20-inch PMTs in mass testing
The Jiangmen Underground Neutrino Observatory (JUNO) is an ambitious multipurpose neutrino experiment designed to determine the neutrino mass ordering, with an impressive energy resolution goal of at least 3% at 1 MeV. To achieve a photon detection coverage of approximately 75%, JUNO will utilize two types of 20-inch photomultiplier tubes (PMTs): the large PMT (LPMT) and the microchannel plate PMT (MCP-PMT). A significant concern in high-precision neutrino measurements is the dark count rate (DCR) of PMTs, which introduces noise that can adversely affect energy measurement accuracy. During the mass testing phase of the JUNO 20-inch PMTs, comprehensive measurements of the DCR were undertaken. These measurements not only captured the DCR values of individual PMTs but also examined the stability and temperature dependence of the DCR at an operating gain of (1 × 107). This paper presents a detailed characterization of the DCR of the JUNO 20-inch PMTs, investigating factors such as cooling time, temperature variations, and long-term stability using the JUNO Pan-Asia PMT testing facilities. The results reveal distinct DCR characteristics between the two types of PMTs, providing valuable insights into the nature of DCR and its implications for JUNO's scientific objectives. In addition to performance characterization, we implemented a monitoring system to track DCR stability over time. Notably, several spikes in DCR were identified, prompting a preliminary investigation into their causes. Potential factors contributing to these spikes, such as flasher events, were explored using coincidence rate analysis and complementary imaging techniques. The findings from this study are crucial for optimizing the performance of PMTs in JUNO, ultimately aiding the experiment in achieving its goals related to neutrino physics.
- 1 July 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (07) , P07024
Design & optimization of the HV divider for JUNO 20-inch PMT
The Jiangmen Underground Observatory (JUNO) is a 20-kton liquid scintillator detector that employs 20,012 20-inch photomultiplier tubes (PMTs) as photon sensors, with 5,012 dynode-PMTs from HAMAMATSU Photonics K.K. (HPK), and 15,000 MCP-PMTs from North Night Vision Technology (NNVT) installed in pure water. JUNO aims to provide long-lasting and the best performance operation by utilizing a high-transparency liquid scintillator, high detection efficiency PMTs, and specially designed electronics including water-proof potting for the high voltage (HV) dividers of PMTs. In this paper, we present a summary of the design and optimization of HV dividers for both types of 20-inch PMTs, which includes collection efficiency, charge resolution, HV divider current, pulse shape, and maximum amplitude restriction. We have developed and finalized four schemes of the HV divider for different scenarios, including the final version selected by JUNO. All 20,012 20-inch PMTs have successfully undergone production and burning tests.
- 1 July 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (07) , P07024
Design & optimization of the HV divider for JUNO 20-inch PMT
The Jiangmen Underground Observatory (JUNO) is a 20-kton liquid scintillator detector that employs 20,012 20-inch photomultiplier tubes (PMTs) as photon sensors, with 5,012 dynode-PMTs from HAMAMATSU Photonics K.K. (HPK), and 15,000 MCP-PMTs from North Night Vision Technology (NNVT) installed in pure water. JUNO aims to provide long-lasting and the best performance operation by utilizing a high-transparency liquid scintillator, high detection efficiency PMTs, and specially designed electronics including water-proof potting for the high voltage (HV) dividers of PMTs. In this paper, we present a summary of the design and optimization of HV dividers for both types of 20-inch PMTs, which includes collection efficiency, charge resolution, HV divider current, pulse shape, and maximum amplitude restriction. We have developed and finalized four schemes of the HV divider for different scenarios, including the final version selected by JUNO. All 20,012 20-inch PMTs have successfully undergone production and burning tests.
- 11 April 2025
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 36 (5) , 1-12
Performance of plastic scintillator modules for top veto tracker at Taishan Antineutrino Observatory
- 11 April 2025
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 36 (5) , 1-12
Performance of plastic scintillator modules for top veto tracker at Taishan Antineutrino Observatory
- Open Access
Non-cyclic prototype of JUNO-TAO VETO water tank with 3 inch PMTs
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future reactor neutrino experiments, and to provide a benchmark measurement to test nuclear databases. A Cerenkov water tank system with a thickness of 1.2 m pure water will be located around the central detector of TAO. The water tank system designed with 300 3" PMTs (SPMT) will use the same electronics as JUNO SPMT, but with online software multiplicity trigger. The performance of a Cerenkov detector with the JUNO SPMT and electronics designed for liquid scintillator detector needs to be checked, including the software triggering. The features and the long stability of the detector without water circulation also needs to be checked as a common concern and a backup option for future JUNO-TAO running. Here we will summary the integration and testing of a prototype water tank detector system, including SPMT, electronics, data taking, simulation and measurement results.
Open AccessNon-cyclic prototype of JUNO-TAO VETO water tank with 3 inch PMTs
The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future reactor neutrino experiments, and to provide a benchmark measurement to test nuclear databases. A Cerenkov water tank system with a thickness of 1.2 m pure water will be located around the central detector of TAO. The water tank system designed with 300 3" PMTs (SPMT) will use the same electronics as JUNO SPMT, but with online software multiplicity trigger. The performance of a Cerenkov detector with the JUNO SPMT and electronics designed for liquid scintillator detector needs to be checked, including the software triggering. The features and the long stability of the detector without water circulation also needs to be checked as a common concern and a backup option for future JUNO-TAO running. Here we will summary the integration and testing of a prototype water tank detector system, including SPMT, electronics, data taking, simulation and measurement results.
- 30 April 2024
- Published by Springer Nature in Complex Analysis and Operator Theory
- Vol. 18 (4) , 1-14
Orthogonal Exponential Functions on the Three-Dimensional Sierpinski Gasket
- 30 April 2024
- Published by Springer Nature in Complex Analysis and Operator Theory
- Vol. 18 (4) , 1-14
Orthogonal Exponential Functions on the Three-Dimensional Sierpinski Gasket