Jubing Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jubing Chen has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
- Chen Sun
Department of Engineering Mechanics, Shanghai Jiao Tong University, Shanghai, China
17 shared publications Jun Yao
Shanghai Jiao Tong University, Department of Engineering Mechanics, Shanghai
6 shared publicationsChen Sun
Shanghai Jiao Tong University
4 shared publications- Keming Zhang
Department of Engineering Foundation, School of Mechanical Engineering, University of Shanghai for Science and Technology
4 shared publications Yihao Zhou
Department of Engineering Mechanics, Shanghai Jiao Tong University, Room 208, Lab center of Engineering Mechanics, 800, Dong Chuan Rd., Shanghai, 200240, CHINA
4 shared publicationsYing Tang
Shanghai Jiao Tong University
4 shared publications
Latest Publications
- 1 September 2026
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 65 (09) , 1-14
Backward ray tracing based cross-window imaging model and in situ calibration method for 3D shape measurement through observation windows of aircraft
Accurate optical three-dimensional (3D) shape measurement through aircraft observation windows is hindered by refractive distortions and the limitations of conventional calibration. We present a binocular imaging model and a corresponding in situ calibration method to address these issues. The model utilizes backway ray tracing and Snell’s law to map the light path through a planar-curved window, quantifying refraction-induced deviations. The calibration method formulates an optimization function constrained by the known spacing between adjacent calibration board features and the planarity of the board, enabling the estimation of model parameters without requiring a priori knowledge of the board’s spatial position. Only a single-frame image of a freely moved calibration board is required in this method, which is a highly desired feature in online and in situ calibration. A series of experiments is carried out, and the effectiveness of the proposed methods is quantitatively discussed. Results demonstrate that the proposed method achieves a relative error of 0.58% in the measurement of a curve surface through a complex observation window, showing a notable improvement in accuracy over the conventional method. The measurement result of the proposed method closely approaches those achieved without the observation window, indicating that the proposed imaging model accurately reconstructs the true light propagation process through complex structures and the proposed calibration method precisely identifies the model parameters.
- 1 September 2026
- Published by SPIE-Intl Soc Optical Eng in Optical Engineering
- Vol. 65 (09) , 1-14
Backward ray tracing based cross-window imaging model and in situ calibration method for 3D shape measurement through observation windows of aircraft
Accurate optical three-dimensional (3D) shape measurement through aircraft observation windows is hindered by refractive distortions and the limitations of conventional calibration. We present a binocular imaging model and a corresponding in situ calibration method to address these issues. The model utilizes backway ray tracing and Snell’s law to map the light path through a planar-curved window, quantifying refraction-induced deviations. The calibration method formulates an optimization function constrained by the known spacing between adjacent calibration board features and the planarity of the board, enabling the estimation of model parameters without requiring a priori knowledge of the board’s spatial position. Only a single-frame image of a freely moved calibration board is required in this method, which is a highly desired feature in online and in situ calibration. A series of experiments is carried out, and the effectiveness of the proposed methods is quantitatively discussed. Results demonstrate that the proposed method achieves a relative error of 0.58% in the measurement of a curve surface through a complex observation window, showing a notable improvement in accuracy over the conventional method. The measurement result of the proposed method closely approaches those achieved without the observation window, indicating that the proposed imaging model accurately reconstructs the true light propagation process through complex structures and the proposed calibration method precisely identifies the model parameters.
- 21 May 2026
- Published by Springer Nature in Acta Mechanica Solida Sinica
- Vol. 39 (6) , 745-746
Preface to the Special Issue in Celebration of Professor Zhenbang Kuang’s 90th Birthday
- 21 May 2026
- Published by Springer Nature in Acta Mechanica Solida Sinica
- Vol. 39 (6) , 745-746
Preface to the Special Issue in Celebration of Professor Zhenbang Kuang’s 90th Birthday
- 27 September 2025
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 195
Full-field adaptive specular projection moiré method for high-precision three-dimensional surface measurement
- 27 September 2025
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 195
Full-field adaptive specular projection moiré method for high-precision three-dimensional surface measurement
- 24 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 37 (21) , 1241-1244
Fringe-Aided Specular Projection Moiré Method for Multi-Area 3D Morphology Measurement
The specular surfaces often exist as multi-areas in industries and require high-precision morphology measurement. This letter proposes a fringe-aided specular projection moiré method for multi-area specular morphology measurement. A strategy for moiré component selection is developed to generate the optimized moiré pattern for different types of mirrors. Additionally, an identification method based on windowed Fourier transform is introduced to detect specular regions. Thus, the principle of the fringe-aided specular projection moiré method is proposed. An experiment is carried out to validate the method’s performance, where a mirror array consisting of two concave and one convex is measured. The results show that the proposed method is able to recognize specular areas and extract the wanted moiré patterns for different mirrors, and the method achieves micron-level precision in morphology measurements.
- 24 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 37 (21) , 1241-1244
Fringe-Aided Specular Projection Moiré Method for Multi-Area 3D Morphology Measurement
The specular surfaces often exist as multi-areas in industries and require high-precision morphology measurement. This letter proposes a fringe-aided specular projection moiré method for multi-area specular morphology measurement. A strategy for moiré component selection is developed to generate the optimized moiré pattern for different types of mirrors. Additionally, an identification method based on windowed Fourier transform is introduced to detect specular regions. Thus, the principle of the fringe-aided specular projection moiré method is proposed. An experiment is carried out to validate the method’s performance, where a mirror array consisting of two concave and one convex is measured. The results show that the proposed method is able to recognize specular areas and extract the wanted moiré patterns for different mirrors, and the method achieves micron-level precision in morphology measurements.
- 10 June 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (6) , 065015
Dynamic refractive index measurement method for droplets based on digital image correlation and inverse method
The measurement and analysis of the refractive index of droplets is a crucial aspect of exploring liquid compositions and studying the physicochemical properties of liquids. The optical measurement techniques currently used to determine the refractive index of transparent droplets are impeded by the substantial liquid volume requirements, making the accurate measurement of the refractive index of micro-scale droplets a significant challenge. To address this issue, the present study proposes a non-contact method for measuring the refractive index of droplets based on digital image correlation (DIC) and inverse method, to achieve high-precision analysis of the refractive index and concentration of micro-droplets. The proposed method designs a dual-module optical imaging system to measure the refractive index of transparent droplets precisely. A physical model is constructed to derive the mathematical mapping between the droplet’s refractive index, image displacement, and geometric contour. The segmentation-aided DIC method enables subpixel-level full-field displacement vector measurements, providing key data for the refractive index inversion model. A side-view camera captures the droplet’s contour, and edge detection algorithm extracts feature coordinates. A synchronization calibration method aligns the spatial coordinates of the dual imaging systems. Finally, the refractive index parameters are inverted using experimental data and a particle swarm optimization algorithm. Experimental results demonstrate high precision in measuring the refractive index of micro-scale droplets.
- 10 June 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (6) , 065015
Dynamic refractive index measurement method for droplets based on digital image correlation and inverse method
The measurement and analysis of the refractive index of droplets is a crucial aspect of exploring liquid compositions and studying the physicochemical properties of liquids. The optical measurement techniques currently used to determine the refractive index of transparent droplets are impeded by the substantial liquid volume requirements, making the accurate measurement of the refractive index of micro-scale droplets a significant challenge. To address this issue, the present study proposes a non-contact method for measuring the refractive index of droplets based on digital image correlation (DIC) and inverse method, to achieve high-precision analysis of the refractive index and concentration of micro-droplets. The proposed method designs a dual-module optical imaging system to measure the refractive index of transparent droplets precisely. A physical model is constructed to derive the mathematical mapping between the droplet’s refractive index, image displacement, and geometric contour. The segmentation-aided DIC method enables subpixel-level full-field displacement vector measurements, providing key data for the refractive index inversion model. A side-view camera captures the droplet’s contour, and edge detection algorithm extracts feature coordinates. A synchronization calibration method aligns the spatial coordinates of the dual imaging systems. Finally, the refractive index parameters are inverted using experimental data and a particle swarm optimization algorithm. Experimental results demonstrate high precision in measuring the refractive index of micro-scale droplets.
- 16 December 2024
- Published by World Scientific Pub Co Pte Ltd in International Journal of Applied Mechanics
- Vol. 17 (01)
Experimental and Finite Element Analysis on an Elastic–Plastic Hemispherical Asperity Contact Against a Rigid Flat in Plane Strain with Bilinear Hardening
Real surface contact occurs primarily at the asperities, whose morphologies vary based on different processing methods. To simplify this complexity, asperities are often idealized as regular geometric shapes such as spheres or hemispheres. This paper introduces a spherical asperity model under plane strain conditions, derived from finite element analysis. The model establishes relationships between interference and contact area, as well as interference and average contact pressure, which are dependent on the material properties of the asperities. Unlike many previous models that segmented asperity deformation into different stages based on the deformation state of the contact area, this model presents a unified expression that encompasses the elastic, elastic–plastic, and plastic deformation of spherical asperities. This unified approach eliminates potential discontinuities at critical points inherent in piecewise models. Additionally, due to the small contact area of asperities, accurately measuring the contact area during the deformation of a single asperity presents significant challenges. This study employs the digital image correlation (DIC) method to measure the contact area between the spherical asperity and the indenter, with model results validated against experimental data.
- 16 December 2024
- Published by World Scientific Pub Co Pte Ltd in International Journal of Applied Mechanics
- Vol. 17 (01)
Experimental and Finite Element Analysis on an Elastic–Plastic Hemispherical Asperity Contact Against a Rigid Flat in Plane Strain with Bilinear Hardening
Real surface contact occurs primarily at the asperities, whose morphologies vary based on different processing methods. To simplify this complexity, asperities are often idealized as regular geometric shapes such as spheres or hemispheres. This paper introduces a spherical asperity model under plane strain conditions, derived from finite element analysis. The model establishes relationships between interference and contact area, as well as interference and average contact pressure, which are dependent on the material properties of the asperities. Unlike many previous models that segmented asperity deformation into different stages based on the deformation state of the contact area, this model presents a unified expression that encompasses the elastic, elastic–plastic, and plastic deformation of spherical asperities. This unified approach eliminates potential discontinuities at critical points inherent in piecewise models. Additionally, due to the small contact area of asperities, accurately measuring the contact area during the deformation of a single asperity presents significant challenges. This study employs the digital image correlation (DIC) method to measure the contact area between the spherical asperity and the indenter, with model results validated against experimental data.
- 26 November 2024
- Published by Springer Nature in Acta Mechanica Solida Sinica
- Vol. 39 (6) , 755-765
Modeling and Characterization of Residual Stress Distribution of Thin Film/Substrate Structure with Non-negligible Film Thickness from Morphology
- 26 November 2024
- Published by Springer Nature in Acta Mechanica Solida Sinica
- Vol. 39 (6) , 755-765
Modeling and Characterization of Residual Stress Distribution of Thin Film/Substrate Structure with Non-negligible Film Thickness from Morphology
- 19 June 2024
- Published by Elsevier in Measurement
- Vol. 236
Modeling and compensation of phase error in projection moiré
- 19 June 2024
- Published by Elsevier in Measurement
- Vol. 236
Modeling and compensation of phase error in projection moiré
- 7 May 2024
- Published by Springer Nature in Acta Mechanica Sinica
- Vol. 40 (5) , 1-13
Characterization of elastic-plastic contact between wavy surfaces formed by different machining methods
- 7 May 2024
- Published by Springer Nature in Acta Mechanica Sinica
- Vol. 40 (5) , 1-13
Characterization of elastic-plastic contact between wavy surfaces formed by different machining methods
- 22 December 2023
- Published by Wiley in Journal of Applied Mechanics
- Vol. 91 (5) , 1-12
A Theoretical Analysis for Arbitrary Residual Stress of Thin Film/Substrate System With Nonnegligible Film Thickness
Stoney formula is widely used in advanced devices to estimate the residual stress of thin film/substrate system by measuring surface curvature. Many hypotheses including that thin film thickness is ignored are required, thus bringing significant error in characterizing the inhomogeneous residual stress distribution. In this article, arbitrary residual stresses on thin film/substrate structures with nonnegligible film thickness are modeled and characterized. We introduce nonuniform misfit strain and establish the governing equations including mismatched strain, displacements, and interfacial stresses based on the basic elastic theory. The parameterization method and the method of constant variation are used in the process of equation decoupling. The expressions between displacements, surface curvatures, and misfit strain are determined through decoupling calculations. By substituting misfit strain, residual stresses are expressed by parametric equation related to surface curvature. It further indicates that there is a “non-local” part between the film stress and curvature at the same point. Compared to neglecting the film thickness, the proposed method eliminate relative errors up to 58.3%, which is of great significance for stress measurement of thin films and substrates.
- 22 December 2023
- Published by Wiley in Journal of Applied Mechanics
- Vol. 91 (5) , 1-12
A Theoretical Analysis for Arbitrary Residual Stress of Thin Film/Substrate System With Nonnegligible Film Thickness
Stoney formula is widely used in advanced devices to estimate the residual stress of thin film/substrate system by measuring surface curvature. Many hypotheses including that thin film thickness is ignored are required, thus bringing significant error in characterizing the inhomogeneous residual stress distribution. In this article, arbitrary residual stresses on thin film/substrate structures with nonnegligible film thickness are modeled and characterized. We introduce nonuniform misfit strain and establish the governing equations including mismatched strain, displacements, and interfacial stresses based on the basic elastic theory. The parameterization method and the method of constant variation are used in the process of equation decoupling. The expressions between displacements, surface curvatures, and misfit strain are determined through decoupling calculations. By substituting misfit strain, residual stresses are expressed by parametric equation related to surface curvature. It further indicates that there is a “non-local” part between the film stress and curvature at the same point. Compared to neglecting the film thickness, the proposed method eliminate relative errors up to 58.3%, which is of great significance for stress measurement of thin films and substrates.