GLGilad Liberman

Gilad Liberman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gilad Liberman has a total of 60 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Optimized multi‐axis spiral projection MR fingerprinting with subspace reconstruction for rapid whole‐brain high‐isotropic‐resolution quantitative imaging

    by Xiaozhi Cao, Congyu Liao, Siddharth Srinivasan Iyer, Zhixing Wang, Zihan Zhou, Erpeng Dai, Gilad Liberman, Zijing Dong, Ting Gong, Hongjian He, et al.

    Purpose: To improve image quality and accelerate the acquisition of 3D MR fingerprinting (MRF).Methods: Building on the multi‐axis spiral‐projection MRF technique, a subspace reconstruction with locally low‐rank constraint and a modified spiral‐projection spatiotemporal encoding scheme called tiny golden‐angle shuffling were implemented for rapid whole‐brain high‐resolution quantitative mapping. Reconstruction parameters such as the locally low‐rank regularization parameter and the subspace rank were tuned using retrospective in vivo data and simulated examinations. B0 inhomogeneity correction using multifrequency interpolation was incorporated into the subspace reconstruction to further improve the image quality by mitigating blurring caused by off‐resonance effect.Results: The proposed MRF acquisition and reconstruction framework yields high‐quality 1‐mm isotropic whole‐brain quantitative maps in 2 min at better quality compared with 6‐min acquisitions of prior approaches. The proposed method was validated to not induce bias in T1 and T2 mapping. High‐quality whole‐brain MRF data were also obtained at 0.66‐mm isotropic resolution in 4 min using the proposed technique, where the increased resolution was shown to improve visualization of subtle brain structures.Conclusions: The proposed tiny golden‐angle shuffling, MRF with optimized spiral‐projection trajectory and subspace reconstruction enables high‐resolution quantitative mapping in ultrafast acquisition time.


  • Diffusion‐weighted breast MRI of malignancies with submillimeter resolution and immunity to artifacts by spatiotemporal encoding at 3T

    by Eddy Solomon, Gilad Liberman, Noam Nissan, Edna Furman‐Haran, Miri Sklair‐Levy, Lucio Frydman

    Purpose: Diffusion weighted imaging (DWI) is increasingly used in evaluating breast cancer, as complement to DCE measurements of superior spatial resolution. Extracting fine morphological features in DWI is complicated by limitations that sequences such as EPI face, when applied to heterogeneous organs. This study investigates the ability of spatiotemporal encoding (SPEN) MRI to screen breast cancers and define diffusivity features at mm and sub‐mm resolutions on a 3T scannerMethods: Twenty‐one patients with biopsy‐confirmed breast cancer lesions were examined by T2‐weighted and DCE protocols, by EPI‐based DWI, and by SPEN‐based protocols optimized for SNR, robustness and spatial resolution, respectively.Results: Excellent agreement was found between the diffusivity parameters measured by all SPEN protocols and by EPI, with the lower ADCs characteristic of tumors being readily detected. SPEN provided systematically better SNR and improved qualitative results, particularly when dealing with small lesions surrounded by fatty tissue, or lesions close to tissue/air interfaces. SPEN‐derived ADC maps collected at sub‐mm in‐plane resolutions recapitulated the high‐resolution morphology shown by lesions using more sensitive DCE protocols.Conclusion: Measurements on a patient cohort validated SPEN’s ability to quantify the diffusivity changes associated with the presence of breast cancers, while imaging the lesions with reduced distortions at sub‐mm resolutions.


  • Dynamic T2 mapping by multi‐spin‐echo spatiotemporal encoding

    by Qingjia Bao, Lingceng Ma, Gilad Liberman, Eddy Solomon, Ricardo P. Martinho, Lucio Frydman

    Purpose: To develop a pulse sequence for acquiring robust, quantitative T2 relaxation maps in real time.Methods: The pulse scheme relies on fully refocused spatiotemporally encoded multi‐spin‐echo trains, which provide images that are significantly less distorted than spin‐echo echo planar imaging‐based counterparts. This enables single‐shot T2 mapping in inhomogeneity‐prone regions. Another advantage of these schemes stems from their ability to interleave multiple scans in a reference‐free manner, providing an option to increase sensitivity and spatial resolution with minimal motional artifacts.Results: The method was implemented in preclinical and clinical scanners, where single‐shot acquisitions delivered reliable T2 maps in ≤200 ms with ≈250 µm and ≈3 mm resolutions, respectively. Ca. 4 times higher spatial resolutions were achieved for the motion‐compensated interleaved versions of these acquisitions, delivering T2 maps in ca. 10 s per slice. These maps were nearly indistinguishable from multi‐scan relaxometric maps requiring orders‐of‐magnitude longer acquisitions; this was confirmed by mice head and real‐time mice abdomen 7T scans performed following contrast‐agent injections, as well as by 3T human brain and breast scans.Conclusion: This study introduced and demonstrated a new approach for acquiring rapid and quantitative T2 data, which is particularly reliable when operating at high fields and/or targeting heterogeneous organs or regions.


  • Open Access

    Minimal Linear Networks for Magnetic Resonance Image Reconstruction

    by Gilad Liberman, Benedikt A. Poser

    Modern sequences for Magnetic Resonance Imaging (MRI) trade off scan time with computational challenges, resulting in ill-posed inverse problems and the requirement to account for more elaborated signal models. Various deep learning techniques have shown potential for image reconstruction from reduced data, outperforming compressed sensing, dictionary learning and other advanced techniques based on regularization, by characterization of the image manifold. In this work we suggest a framework for reducing a “neural” network to the bare minimum required by the MR physics, reducing the network depth and removing all non-linearities. The networks performed well both on benchmark simulated data and on arterial spin labeling perfusion imaging, showing clear images while preserving sensitivity to the minute signal changes. The results indicate that the deep learning framework plays a major role in MR image reconstruction, and suggest a concrete approach for probing into the contribution of additional elements.


  • Israel’s ‘Voluntary’ Return Policy to Expel Refugees:

    by Yael Agur Orgal, Gilad Liberman, Sigal Kook Avivi


  • A regularized reconstruction pipeline for high‐definition diffusion MRI in challenging regions incorporating a per‐shot image correction

    by Samuel F. Cousin, Gilad Liberman, Eddy Solomon, Martins Otikovs, Lucio Frydman

    Purpose: Diffusion MRI is of interest for clinical research and diagnosis. Whereas high‐ resolution DWI/DTI is hard to achieve by single‐shot methods, interleaved acquisitions can deliver these if motion and/or folding artefacts are overcome. Thanks to its ability to provide zoomed, folding‐free images, spatially encoded MRI can fulfill these requirements. This is here coupled with a regularized reconstruction and parallel receive methods, to deliver a robust scheme for human DWI/DTI at mm and sub‐mm resolutions.Methods: Each shot along the spatially encoded dimension was reconstructed separately to retrieve per‐shot phase maps. These shots, together with coil sensitivities, were combined with spatially encoded quadratic phase‐encoding matrices associated to each shot, into single global operators. Their originating images were then iteratively computed aided by l1 and l2 regularization methods. When needed, motion‐corrupted shots were discarded and replaced by redundant information arising from parallel imaging.Results: Full‐brain DTI experiments at 1 mm and restricted brain DTIs with 0.75 mm nominal in‐plane resolutions were acquired and reconstructed successfully by the new scheme. These 3 Tesla spetiotemporally encoded results compared favorably with EPI counterparts based on segmented and selective excitation schemes provided with the scanner.Conclusion: A new procedure for achieving high‐definition diffusion‐based MRI was developed and demonstrated.


  • Repeatability of dynamic contrast enhanced vp parameter in healthy subjects and patients with brain tumors

    by Moran Artzi, Gilad Liberman, Deborah T. Blumenthal, Felix Bokstein, Orna Aizenstein, Dafna Ben Bashat

    To study the repeatability of plasma volume (vp) extracted from dynamic-contrast-enhanced (DCE) MRI in order to define threshold values for significant longitudinal changes, and to assess changes in patients with high-grade-glioma (HGG).


  • Open Access

    Classification of High-Grade Glioma into Tumor and Nontumor Components Using Support Vector Machine

    by D.T. Blumenthal, M. Artzi, G. Liberman, F. Bokstein, O. Aizenstein, D. Ben Bashat

    BACKGROUND AND PURPOSE: Current imaging assessment of high-grade brain tumors relies on the Response Assessment in Neuro-Oncology criteria, which measure gross volume of enhancing and nonenhancing lesions from conventional MRI sequences. These assessments may fail to reliably distinguish tumor and nontumor. This study aimed to classify enhancing and nonenhancing lesion areas into tumor-versus-nontumor components. MATERIALS AND METHODS: A total of 140 MRI scans obtained from 32 patients with high-grade gliomas and 6 patients with brain metastases were included. Classification of lesion areas was performed using a support vector machine classifier trained on 4 components: enhancing and nonenhancing, tumor and nontumor, based on T1-weighted, FLAIR, and dynamic-contrast-enhancing MRI parameters. Classification results were evaluated by 2-fold cross-validation analysis of the training set and MR spectroscopy. Longitudinal changes of the component volumes were compared with Response Assessment in Neuro-Oncology criteria. RESULTS: Normalized T1-weighted values, FLAIR, plasma volume, volume transfer constant, and bolus-arrival-time parameters differentiated components. High sensitivity and specificity (100%) were obtained within the enhancing and nonenhancing areas. Longitudinal changes in component volumes correlated with the Response Assessment in Neuro-Oncology criteria in 27 patients; 5 patients (16%) demonstrated an increase in tumor component volumes indicating tumor progression. These changes preceded Response Assessment in Neuro-Oncology assessments by several months. Seven patients treated with bevacizumab showed a shift to an infiltrative pattern of progression. CONCLUSIONS: This study proposes an automatic classification method: segmented Response Assessment in Neuro-Oncology criteria based on advanced imaging that reliably differentiates tumor and nontumor components in high-grade gliomas. The segmented Response Assessment in Neuro-Oncology criteria may improve therapy-response assessment and provide earlier indication of progression.


  • Optimization of DCE-MRI protocol for the assessment of patients with brain tumors

    by Moran Artzi, Gilad Liberman, Guy Nadav, Deborah T. Blumenthal, Felix Bokstein, Orna Aizenstein, Dafna Ben Bashat


  • Optimization of two-compartment-exchange-model analysis for dynamic contrast-enhanced mri incorporating bolus arrival time

    by Guy Nadav, Gilad Liberman, Moran Artzi, Nahum Kiryati, Dafna Ben Bashat

    Purpose To optimize the analysis of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) under the two-compartment-exchange-model (2CXM) and to incorporate voxelwise bolus-arrival-time (BAT). Materials and Methods The accuracy of the pharmacokinetic (PK) parameters, extracted from 3T DCE-MRI using 2CXM, was tested under several conditions: eight algorithms for data estimation; correction for BAT; using model selection; different temporal resolution and scan duration. Comparisons were performed on simulated data. The best algorithm was applied to seven patients with brain tumors or following stroke. The extracted perfusion parameters were compared to those of dynamic susceptibility contrast MRI (DSC-MRI). Results ACoPeD (AIF-corrected-perfusion-DCE-MRI), an analysis using a 2nd derivative regularized-spline and incorporating BAT, achieved the most accurate estimation in simulated data, mean-relative-error: Fp, F, vp, ve: 24.8%, 41.7%, 26.4%, 27.2% vs. 76.5%, 190.8%, 78.8%, 82.39% of the direct four parameters estimation (one-sided two-sample t-test, P < 0.001). Correction for BAT increased the estimation accuracy of the PK parameters by more than 30% and provided a supertemporal resolution estimation of the BAT (higher than the acquired resolution, mean-absolute-error 0.2 sec). High temporal resolution (∼2 sec) is required to avoid biased estimation of PK parameters, and long scan duration (∼20 min) is important for reliable permeability but not for perfusion estimations, mean-error-reduction: E: ∼12%, ve: ∼6%. Using ACoPeD, PK values from normal-appearing white matter, gray matter, and lesion were extracted from patients. Preliminary results showed significant voxelwise correlations to DSC-MRI, between flow values in a patient following stroke (r = 0.49, P < 0.001), and blood volume in a patient with a brain tumor (r = 0.62, P < 0.001). Conclusion This study proposes an optimized analysis method, ACoPeD, for tissue perfusion and permeability estimation using DCE-MRI, to be used in clinical settings. Level of Evidence: 1 J. Magn. Reson. Imaging 2017;45:237–249.