Heiner Denker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Heiner Denker has a total of 126 co-authors. Here are the top co-authors by number of shared publications:
- Christian Lisdat
Physikalisch-Technische Bundesanstalt
2 shared publications - Christian Voigt
GFZ German Research Centre for Geosciences, Section 1.2 Global Geomonitoring and Gravity Field, Telegrafenberg, 14473 Potsdam, Germany
2 shared publications - Ekkehard Peik
Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, Germany
2 shared publications Gérard Petit
Bureau International des Poids et Mesures (BIPM)
2 shared publications- Helen S. Margolis
National Physical Laboratory
2 shared publications - Johannes Ihde
Federal Agency for Cartography and Geodesy (BKG)
2 shared publications
Latest Publications
- Open Access
- 7 October 2026
- Published by Springer Nature in Nature
- Vol. 658 (8137) , 897-902
A thorium-229 optical nuclear clock with feedback loop
The laser-accessible nuclear transition in the thorium-229 isotope has been identified as a candidate for realizing an optical nuclear clock 1 that might outperform current optical clocks based on electron-shell transitions in atoms or ions 2 . It is expected to be more robust against external perturbations 3,4 and to provide enhanced sensitivity in clock-based tests of the fundamental principles of physics 5,6 . Here we realize a thorium-229 nuclear clock by stabilizing a continuous-wave laser to the 148-nm nuclear transition with rapid feedback based on absorption spectroscopy 7 . The thorium-229 nuclei are embedded in a millimetre-sized, room-temperature calcium fluoride crystal. A subharmonic of the 148-nm radiation is continuously compared with a Yb + single-ion clock. The nuclear clock shows a shot-noise-limited fractional frequency instability of $$3\times 1{0}^{-12}/\sqrt{\tau /{\rm{s}}}$$ where τ is the averaging time, approaching 10 −15 instabilities over 1 day of operation. Improvements to the instability by several orders of magnitude are projected for future devices. We use the nuclear clock to constrain models of ultralight dark matter by searching for periodic fluctuations and slow drifts in the nuclear transition energy, on timescales between 20 s and 1 day. Benefitting from the enhanced sensitivity of the thorium-229 transition, these constraints compete with the best atomic clocks concerning dark matter coupling to photons and go beyond previous measurements regarding coupling to the strong force.- 7 October 2026
- Published by Springer Nature in Nature
- Vol. 658 (8137) , 897-902
Open AccessA thorium-229 optical nuclear clock with feedback loop
The laser-accessible nuclear transition in the thorium-229 isotope has been identified as a candidate for realizing an optical nuclear clock 1 that might outperform current optical clocks based on electron-shell transitions in atoms or ions 2 . It is expected to be more robust against external perturbations 3,4 and to provide enhanced sensitivity in clock-based tests of the fundamental principles of physics 5,6 . Here we realize a thorium-229 nuclear clock by stabilizing a continuous-wave laser to the 148-nm nuclear transition with rapid feedback based on absorption spectroscopy 7 . The thorium-229 nuclei are embedded in a millimetre-sized, room-temperature calcium fluoride crystal. A subharmonic of the 148-nm radiation is continuously compared with a Yb + single-ion clock. The nuclear clock shows a shot-noise-limited fractional frequency instability of $$3\times 1{0}^{-12}/\sqrt{\tau /{\rm{s}}}$$ where τ is the averaging time, approaching 10 −15 instabilities over 1 day of operation. Improvements to the instability by several orders of magnitude are projected for future devices. We use the nuclear clock to constrain models of ultralight dark matter by searching for periodic fluctuations and slow drifts in the nuclear transition energy, on timescales between 20 s and 1 day. Benefitting from the enhanced sensitivity of the thorium-229 transition, these constraints compete with the best atomic clocks concerning dark matter coupling to photons and go beyond previous measurements regarding coupling to the strong force. - Open Access
- 12 June 2025
- Published by Optica Publishing Group in Optica
- Vol. 12 (6) , 843
Coordinated international comparisons between optical clocks connected via fiber and satellite links
Optical clocks provide ultraprecise frequency references that are vital for international metrology as well as for tests of fundamental physics. To investigate the level of agreement between different clocks, we simultaneously measured the frequency ratios between ten optical clocks in six different countries, using fiber and satellite links. This is the largest coordinated comparison to date, from which we present a subset of 38 optical frequency ratios and an evaluation of the correlations between them. Four ratios were measured directly for the first time to our knowledge, while others had significantly lower uncertainties than previously achieved, supporting the advance toward a redefinition of the second and the use of optical standards for international time scales.
- 12 June 2025
- Published by Optica Publishing Group in Optica
- Vol. 12 (6) , 843
Open AccessCoordinated international comparisons between optical clocks connected via fiber and satellite links
Optical clocks provide ultraprecise frequency references that are vital for international metrology as well as for tests of fundamental physics. To investigate the level of agreement between different clocks, we simultaneously measured the frequency ratios between ten optical clocks in six different countries, using fiber and satellite links. This is the largest coordinated comparison to date, from which we present a subset of 38 optical frequency ratios and an evaluation of the correlations between them. Four ratios were measured directly for the first time to our knowledge, while others had significantly lower uncertainties than previously achieved, supporting the advance toward a redefinition of the second and the use of optical standards for international time scales.
- Top Cited PapersOpen Access
- 3 June 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 21 (6) , L061001
Long-distance chronometric leveling with a portable optical clock
We have measured the geopotential difference between two locations separated by 457 km by comparison of two optical lattice clocks via an interferometric fiber link, utilizing the gravitational redshift of the clock transition frequency. The clocks have been compared side-by-side before and after one of the clocks was moved to the remote location. The chronometrically measured geopotential difference of agrees with an independent geodetic determination of . The uncertainty of the chronometric geopotential difference is equivalent to an uncertainty of in height.- 3 June 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 21 (6) , L061001
Top Cited PapersOpen AccessLong-distance chronometric leveling with a portable optical clock
We have measured the geopotential difference between two locations separated by 457 km by comparison of two optical lattice clocks via an interferometric fiber link, utilizing the gravitational redshift of the clock transition frequency. The clocks have been compared side-by-side before and after one of the clocks was moved to the remote location. The chronometrically measured geopotential difference of agrees with an independent geodetic determination of . The uncertainty of the chronometric geopotential difference is equivalent to an uncertainty of in height. - 19 September 2018
- Published by Springer Nature in Journal of Geodesy
- Vol. 93 (5) , 723-747
On the computation of gravitational effects for tesseroids with constant and linearly varying density
- 19 September 2018
- Published by Springer Nature in Journal of Geodesy
- Vol. 93 (5) , 723-747
On the computation of gravitational effects for tesseroids with constant and linearly varying density
- Open Access
- 12 December 2017
- Published by Springer Nature in Journal of Geodesy
- Vol. 92 (5) , 487-516
Geodetic methods to determine the relativistic redshift at the level of 10−18 in the context of international timescales: a review and practical results
- 12 December 2017
- Published by Springer Nature in Journal of Geodesy
- Vol. 92 (5) , 487-516
Open AccessGeodetic methods to determine the relativistic redshift at the level of 10−18 in the context of international timescales: a review and practical results
- 31 July 2012
- Published by Springer Nature
- p. 185-291
Regional Gravity Field Modeling: Theory and Practical Results
- 31 July 2012
- Published by Springer Nature
- p. 185-291
Regional Gravity Field Modeling: Theory and Practical Results
- 9 April 2010
- Published by Springer Nature
- p. 277-296
Validation of Satellite Gravity Field Models by Regional Terrestrial Data Sets
- 9 April 2010
- Published by Springer Nature
- p. 277-296
Validation of Satellite Gravity Field Models by Regional Terrestrial Data Sets
- 26 February 2010
- Published by Springer Nature
- p. 315-320
EUVN_DA: Realization of the European Continental GPS/leveling Network
- 26 February 2010
- Published by Springer Nature
- p. 315-320
EUVN_DA: Realization of the European Continental GPS/leveling Network