Toshitaka Ikehara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Toshitaka Ikehara has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
Hiroshi Miyamoto
Department of Physiology, Institute of Health Biosciences, The University of Tokushima Graduate School, Tokushima 770-8503, Japan
19 shared publicationsHisao Yamaguchi
University of Tokushima
11 shared publicationsKeiko Hosokawa
Department of Physiology, Course of Preventive Medicine, School of Medicine, The University of Tokushima, Tokushima, Japan
11 shared publicationsTetsuhiro Sakai
7 shared publicationsYohsuke Kinouchi
Institute of Technology and Sciences, The University of Tokushima, 2-1 Minamijosanjima-cho, Tokushima 770-8506, Japan
7 shared publicationsAkira Takahashi
University of Tokushima
5 shared publications
Latest Publications
- 4 February 2021
- Published by Wiley in Bioelectromagnetics
- Vol. 42 (3) , 224-237
Evaluation of Temperature Increase From Joule Heat in Numerical Tooth Model by Applying 500 kHz Current for Apical Periodontitis Treatment—Effect of Applied Voltage and Tooth Conductivity
For apical periodontitis treatments, a new method with the insertion of an electrode into the root canal of a tooth and application of a current at 500 kHz to sterilize the area by Joule heat has attracted attention. However, few studies have quantified the temperature increase in the root canal. This study aimed to investigate the basic characteristics of the temperature increase in a simple and standard tooth model when energizing a current at 500 kHz to the numerical tooth model with typical electrical and physical properties. We developed a numerical model of a standard tooth (dentin) and periodontal tissues consisting of an alveolar bone, cortical bone, and gingiva, and physiological saline in a root canal and calculated the temperature increase inside the numerical model by a coupled analysis of current and heat when a voltage was applied across the electrodes. The calculated results for the different applied voltages showed a temperature increase at the apical portion of the root canal, which increased with the applied voltage even for the same total supplied energy. The temperature increase occurred at the apical portion of the root canal as the tooth conductivity decreased. When the tooth conductivity was high, a current passed through the dentin, which led to a decrease in the temperature at the apical portion of the root canal. However, a chemical solution with a higher conductivity in the root canal tended to increase the temperature at the apical portion of the root canal, regardless of the tooth conductivity. More efficient approaches for increasing the spatial and temporal temperature for the tooth model target are needed. © 2021 Bioelectromagnetics Society.
- 4 February 2021
- Published by Wiley in Bioelectromagnetics
- Vol. 42 (3) , 224-237
Evaluation of Temperature Increase From Joule Heat in Numerical Tooth Model by Applying 500 kHz Current for Apical Periodontitis Treatment—Effect of Applied Voltage and Tooth Conductivity
For apical periodontitis treatments, a new method with the insertion of an electrode into the root canal of a tooth and application of a current at 500 kHz to sterilize the area by Joule heat has attracted attention. However, few studies have quantified the temperature increase in the root canal. This study aimed to investigate the basic characteristics of the temperature increase in a simple and standard tooth model when energizing a current at 500 kHz to the numerical tooth model with typical electrical and physical properties. We developed a numerical model of a standard tooth (dentin) and periodontal tissues consisting of an alveolar bone, cortical bone, and gingiva, and physiological saline in a root canal and calculated the temperature increase inside the numerical model by a coupled analysis of current and heat when a voltage was applied across the electrodes. The calculated results for the different applied voltages showed a temperature increase at the apical portion of the root canal, which increased with the applied voltage even for the same total supplied energy. The temperature increase occurred at the apical portion of the root canal as the tooth conductivity decreased. When the tooth conductivity was high, a current passed through the dentin, which led to a decrease in the temperature at the apical portion of the root canal. However, a chemical solution with a higher conductivity in the root canal tended to increase the temperature at the apical portion of the root canal, regardless of the tooth conductivity. More efficient approaches for increasing the spatial and temporal temperature for the tooth model target are needed. © 2021 Bioelectromagnetics Society.
- 1 December 2010
- Published by Elsevier in Biochimica et Biophysica Acta (BBA) - General Subjects
- Vol. 1800 (12) , 1221-1230
Effects of exposure to a time-varying 1.5 T magnetic field on the neurotransmitter-activated increase in intracellular Ca2+ in relation to actin fiber and mitochondrial functions in bovine adrenal chromaffin cells
- 1 December 2010
- Published by Elsevier in Biochimica et Biophysica Acta (BBA) - General Subjects
- Vol. 1800 (12) , 1221-1230
Effects of exposure to a time-varying 1.5 T magnetic field on the neurotransmitter-activated increase in intracellular Ca2+ in relation to actin fiber and mitochondrial functions in bovine adrenal chromaffin cells
- 3 November 2007
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 45 (12) , 1237-1241
Development of a new water sterilization device with a 365 nm UV-LED
Ultraviolet (UV) irradiation is an effective disinfection method. In sterilization equipment, a low-pressure mercury lamp emitting an effective germicidal UVC (254 nm) is used as the light source. However, the lamp, which contains mercury, must be disposed of at the end of its lifetime or following damage due to physical shock or vibration. We investigated the suitability of an ultraviolet light-emitting diode at an output wavelength of 365 nm (UVA-LED) as a sterilization device, comparing with the other wavelength irradiation such as 254 nm (a low-pressure mercury lam) and 405 nm (LED). We used a commercially available UVA-LED that emitted light at the shortest wavelength and at the highest output energy. The new sterilization system using the UVA-LED was able to inactivate bacteria, such as Escherichia coli DH5α, Enteropathogenic E. coli, Vibrio parahaemolyticus, Staphylococcus aureus, and Salmonella enterica serovar Enteritidis. The inactivations of the bacteria were dependent on the accumulation of UVA irradiation. Taking advantage of the safety and compact size of LED devices, we expect that the UVA-LED sterilization device can be developed as a new type of water sterilization device
- 3 November 2007
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 45 (12) , 1237-1241
Development of a new water sterilization device with a 365 nm UV-LED
Ultraviolet (UV) irradiation is an effective disinfection method. In sterilization equipment, a low-pressure mercury lamp emitting an effective germicidal UVC (254 nm) is used as the light source. However, the lamp, which contains mercury, must be disposed of at the end of its lifetime or following damage due to physical shock or vibration. We investigated the suitability of an ultraviolet light-emitting diode at an output wavelength of 365 nm (UVA-LED) as a sterilization device, comparing with the other wavelength irradiation such as 254 nm (a low-pressure mercury lam) and 405 nm (LED). We used a commercially available UVA-LED that emitted light at the shortest wavelength and at the highest output energy. The new sterilization system using the UVA-LED was able to inactivate bacteria, such as Escherichia coli DH5α, Enteropathogenic E. coli, Vibrio parahaemolyticus, Staphylococcus aureus, and Salmonella enterica serovar Enteritidis. The inactivations of the bacteria were dependent on the accumulation of UVA irradiation. Taking advantage of the safety and compact size of LED devices, we expect that the UVA-LED sterilization device can be developed as a new type of water sterilization device
- 27 August 2003
- Published by Wiley in Bioelectromagnetics
- Vol. 24 (7) , 457-464
Effects of ELF magnetic field on membrane protein structure of living HeLa cells studied by Fourier transform infrared spectroscopy
The effects of exposure to a 50 Hz magnetic field (maximum of 41.7 to 43.6 mT) on the membrane protein structures of living HeLa cells were studied using attenuated total reflection infrared spectroscopy. One min of such exposure shifted peak absorbance of the amide I band to a smaller wave number, reduced peak absorbance of the amide II band, and increased absorbance at around 1600 cm−1. These results suggest that exposure to the ELF magnetic field has reversible effects on the N–H inplane bending and C–N stretching vibrations of peptide linkages, and changes the secondary structures of α‐helix and β‐sheet in cell membrane proteins. Bioelectromagnetics 24:457–464, 2003.
- 27 August 2003
- Published by Wiley in Bioelectromagnetics
- Vol. 24 (7) , 457-464
Effects of ELF magnetic field on membrane protein structure of living HeLa cells studied by Fourier transform infrared spectroscopy
The effects of exposure to a 50 Hz magnetic field (maximum of 41.7 to 43.6 mT) on the membrane protein structures of living HeLa cells were studied using attenuated total reflection infrared spectroscopy. One min of such exposure shifted peak absorbance of the amide I band to a smaller wave number, reduced peak absorbance of the amide II band, and increased absorbance at around 1600 cm−1. These results suggest that exposure to the ELF magnetic field has reversible effects on the N–H inplane bending and C–N stretching vibrations of peptide linkages, and changes the secondary structures of α‐helix and β‐sheet in cell membrane proteins. Bioelectromagnetics 24:457–464, 2003.
- 10 September 2002
- Published by Wiley in Bioelectromagnetics
- Vol. 23 (7) , 505-515
Effects of a time varying strong magnetic field on release of cytosolic free Ca2+ from intracellular stores in cultured bovine adrenal chromaffin cells
This study was made to explain the mechanisms for the effects of exposure to a time varying 1.51 T magnetic field on the intracellular Ca2+ signaling pathway. The exposure inhibited an increase in intracellular Ca2+ concentration ([Ca2+]i) in bovine chromaffin cells induced by addition of bradykinin (BK) to a Ca2+ free medium. The exposure did not change BK induced production of inositol 1,4,5‐trisphosphate (IP3). [Ca2+]i was markedly increased in IP3 loaded cells, and this increase was inhibited by the magnetic field exposure. A similar increase in [Ca2+]i by other drugs, which stimulated Ca2+ release from intracellular Ca2+ stores, was again inhibited by the same exposure. However, transmembrane Ca2+ fluxes caused in the presence of thapsigargin were not inhibited by the magnetic field exposure in a Ca2+ containing medium. Inhibition of the BK induced increase in [Ca2+]i by the exposure for 30 min was mostly recovered 1 h after exposure ended. Our results reveal that the magnetic field exposure inhibits Ca2+ release from intracellular Ca2+ stores, but that BK bindings to BK receptors of the cell membrane and intracellular inositol IP3 production are not influenced. Bioelectromagnetics 23:505–515, 2002.
- 10 September 2002
- Published by Wiley in Bioelectromagnetics
- Vol. 23 (7) , 505-515
Effects of a time varying strong magnetic field on release of cytosolic free Ca2+ from intracellular stores in cultured bovine adrenal chromaffin cells
This study was made to explain the mechanisms for the effects of exposure to a time varying 1.51 T magnetic field on the intracellular Ca2+ signaling pathway. The exposure inhibited an increase in intracellular Ca2+ concentration ([Ca2+]i) in bovine chromaffin cells induced by addition of bradykinin (BK) to a Ca2+ free medium. The exposure did not change BK induced production of inositol 1,4,5‐trisphosphate (IP3). [Ca2+]i was markedly increased in IP3 loaded cells, and this increase was inhibited by the magnetic field exposure. A similar increase in [Ca2+]i by other drugs, which stimulated Ca2+ release from intracellular Ca2+ stores, was again inhibited by the same exposure. However, transmembrane Ca2+ fluxes caused in the presence of thapsigargin were not inhibited by the magnetic field exposure in a Ca2+ containing medium. Inhibition of the BK induced increase in [Ca2+]i by the exposure for 30 min was mostly recovered 1 h after exposure ended. Our results reveal that the magnetic field exposure inhibits Ca2+ release from intracellular Ca2+ stores, but that BK bindings to BK receptors of the cell membrane and intracellular inositol IP3 production are not influenced. Bioelectromagnetics 23:505–515, 2002.
- 17 March 2000
- Published by Wiley in Bioelectromagnetics
- Vol. 21 (3) , 228-237
Effects on Rb+(K+) uptake of HeLa cells in a high K+ medium of exposure to a switched 1.7 tesla magnetic field
Effects of a switched, time‐varying 1.7 T magnetic field on Rb+(K+) uptake by HeLa S3 cells incubated in an isosmotic high K+ medium were examined. The magnetic flux density was varied intermittently from 0.07–1.7 T at an interval of 3 s. K+ uptake was activated by replacement of normal medium by high K+ medium. A membrane‐permeable Ca2+ chelating agent (BAPTA‐AM) and Ca2+‐de pendent K+ channel inhibitors (quinine, charibdotoxin, and iberiotoxin) were found to reduce the Rb+(K+ ) uptake by about 30–40%. Uptake of K+ that is sensitive to these drugs is possibly mediated by Ca2+‐dependent K+ channels. The intermittent magnetic field partly suppress ed the drug‐sensitive K+ uptake by about 30–40% (P < 0.05). To test the mechanism of inhibition by the magnetic fields, intracellular Ca2+ concentration ([Ca2+]c) was measured using Fura 2‐AM. When cells were placed in the high K+ ; medium, [Ca2+]c increased to about 1.4 times the original level, but exposure to the magnetic fields completely suppressed the increase (P < 0.01). Addition of a Ca2+ ionophore (ionomycin) to the high K+ medium increased [Ca2+]c to the level of control cells, regardless of exposure to the magnetic field. But the inhibition of K+ uptake by the magnetic fields was not restored by addition of ionomycin. Based on our previous results on magnetic field‐induced changes in properties of the cell membrane, these results indicate that exposure to the magnetic fields partly suppresses K+ influx, which may be mediated by Ca2+‐dependent K+ channels. The suppress ion of K+ fluxes could relate to a change in electric properties of cell surface and an inhibition of Ca2+ influx mediated by Ca2+ channels of either the cell plasma membrane or the inner vesicular membrane of intracellular Ca2+ stores. Bioelectromagnetics 21:228–237, 2000.
- 17 March 2000
- Published by Wiley in Bioelectromagnetics
- Vol. 21 (3) , 228-237
Effects on Rb+(K+) uptake of HeLa cells in a high K+ medium of exposure to a switched 1.7 tesla magnetic field
Effects of a switched, time‐varying 1.7 T magnetic field on Rb+(K+) uptake by HeLa S3 cells incubated in an isosmotic high K+ medium were examined. The magnetic flux density was varied intermittently from 0.07–1.7 T at an interval of 3 s. K+ uptake was activated by replacement of normal medium by high K+ medium. A membrane‐permeable Ca2+ chelating agent (BAPTA‐AM) and Ca2+‐de pendent K+ channel inhibitors (quinine, charibdotoxin, and iberiotoxin) were found to reduce the Rb+(K+ ) uptake by about 30–40%. Uptake of K+ that is sensitive to these drugs is possibly mediated by Ca2+‐dependent K+ channels. The intermittent magnetic field partly suppress ed the drug‐sensitive K+ uptake by about 30–40% (P < 0.05). To test the mechanism of inhibition by the magnetic fields, intracellular Ca2+ concentration ([Ca2+]c) was measured using Fura 2‐AM. When cells were placed in the high K+ ; medium, [Ca2+]c increased to about 1.4 times the original level, but exposure to the magnetic fields completely suppressed the increase (P < 0.01). Addition of a Ca2+ ionophore (ionomycin) to the high K+ medium increased [Ca2+]c to the level of control cells, regardless of exposure to the magnetic field. But the inhibition of K+ uptake by the magnetic fields was not restored by addition of ionomycin. Based on our previous results on magnetic field‐induced changes in properties of the cell membrane, these results indicate that exposure to the magnetic fields partly suppresses K+ influx, which may be mediated by Ca2+‐dependent K+ channels. The suppress ion of K+ fluxes could relate to a change in electric properties of cell surface and an inhibition of Ca2+ influx mediated by Ca2+ channels of either the cell plasma membrane or the inner vesicular membrane of intracellular Ca2+ stores. Bioelectromagnetics 21:228–237, 2000.
- 1 October 1999
- Published by Elsevier in Life Sciences
- Vol. 65 (21) , PL247-PL252
Stimulatory effect of enkephalins on calcium efflux from bovine adrenal chromaffin cells in culture
- 1 October 1999
- Published by Elsevier in Life Sciences
- Vol. 65 (21) , PL247-PL252
Stimulatory effect of enkephalins on calcium efflux from bovine adrenal chromaffin cells in culture
- 1 March 1995
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 70 (3) , 234-239
Blood flow velocity in the common carotid artery in humans during graded exercise on a treadmill
Cerebral blood volume flow and flow velocity have been reported to increase during dynamic exercise, but whether the two increase in parallel and whether both increases occur as functions of exercise intensity remain unsettled. In this study, blood flow velocity in the common carotid artery was measured using the Doppler ultrasound method in eight healthy male students during graded treadmill exercise. The exercise consisted of stepwise progressive increases and decreases in exercise intensity. The peak intensity corresponded to approximately 85% of maximal oxygen consumption. During this exercise, the heart rate (fc), mean blood pressure (BP) in the brachial artery and mean blood flow velocity (νcc) in the common carotid artery increased as functions of exercise intensity. At the peak exercise intensity, (fc), BP and νcc increased by 134.5%, 20.5% and 51.8% over the control levels before exercise (P < 0.01), respectively. The resistance index (RI) and pulsatility index (PI) were determined from the velocity profile and were expected to reflect the distal cerebral blood flow resistance. The RI and PI increased during the graded exercise, but tended to decrease at the highest levels of exercise intensity. As νcc increased with increases in exercise intensity it would be expected that cerebral blood flow would also increase at these higher intensities. It is also suggested that blood flow velocity in the cerebral artery does not proportionately reflect the cerebral blood flow during dynamic exercise, since the cerebral blood flow resistance changes.
- 1 March 1995
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 70 (3) , 234-239
Blood flow velocity in the common carotid artery in humans during graded exercise on a treadmill
Cerebral blood volume flow and flow velocity have been reported to increase during dynamic exercise, but whether the two increase in parallel and whether both increases occur as functions of exercise intensity remain unsettled. In this study, blood flow velocity in the common carotid artery was measured using the Doppler ultrasound method in eight healthy male students during graded treadmill exercise. The exercise consisted of stepwise progressive increases and decreases in exercise intensity. The peak intensity corresponded to approximately 85% of maximal oxygen consumption. During this exercise, the heart rate (fc), mean blood pressure (BP) in the brachial artery and mean blood flow velocity (νcc) in the common carotid artery increased as functions of exercise intensity. At the peak exercise intensity, (fc), BP and νcc increased by 134.5%, 20.5% and 51.8% over the control levels before exercise (P < 0.01), respectively. The resistance index (RI) and pulsatility index (PI) were determined from the velocity profile and were expected to reflect the distal cerebral blood flow resistance. The RI and PI increased during the graded exercise, but tended to decrease at the highest levels of exercise intensity. As νcc increased with increases in exercise intensity it would be expected that cerebral blood flow would also increase at these higher intensities. It is also suggested that blood flow velocity in the cerebral artery does not proportionately reflect the cerebral blood flow during dynamic exercise, since the cerebral blood flow resistance changes.
- 1 December 1993
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 67 (6) , 486-491
Changes in carotid blood flow and electrocardiogram in humans during and after walking on a treadmill
Blood flow velocity in the common carotid artery and the electrocardiogram were measured simultaneously by telemetry in seven male subjects during 20-min walking on a treadmill at an exercise intensity corresponding to a mean oxygen uptake of 26.0 (SD 2.9) ml · kg −1 · min −1. The mean cardiac cycle was shortened from 0.814 (SD 0.103) s to 0.452 (SD 0.054) s during this exercise. Of this shortening, 73% was due to shortening of the diastolic period and 27% to shortening of the systolic period. In the relatively small shortening of the mean systolic period [from 0.377 (SD 0.043) s to 0.268 (SD 0.029) s], the isovolumetric contraction time was shortened by 56%. During exercise, the heart rate (fc) increased by 79.4% [from 74.3 (SD 9.3) beats · min −1 to 133.3 (SD 14.8) beats · min −1], and the peak blood velocity (S1) in the common carotid artery increased by 56.1% [from 0.82 (SD 0.10) m · s−1 to 1.28 (SD 0.11) m · s−1]. After exercise, the S1 decreased rapidly to the resting level. The fc decreased more slowly, still being higher than the initial resting level 5 min after exercise. The diastolic velocity wave and the end-diastolic foot decreased during exercise. The blood flow rate in the carotid artery increased transiently by 13.5% at the beginning of exercise [from 5.62 (SD 0.63) ml · s−1 to 6.38 (SD 0.85) ml · s−1] and by 26.5% at the end of the exercise period [from 5.62 (SD 0.63) ml · s−1 to 7.11 (SD 1.34) ml · s−1]. The increase of blood flow in the carotid artery at the onset of exercise may have been mainly related to cerebral activation, and partly to an increase of blood flow to the skin of the head. The physiological significance for cerebral function of the increase of blood flow in the artery after the end of exercise is unknown.
- 1 December 1993
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 67 (6) , 486-491
Changes in carotid blood flow and electrocardiogram in humans during and after walking on a treadmill
Blood flow velocity in the common carotid artery and the electrocardiogram were measured simultaneously by telemetry in seven male subjects during 20-min walking on a treadmill at an exercise intensity corresponding to a mean oxygen uptake of 26.0 (SD 2.9) ml · kg −1 · min −1. The mean cardiac cycle was shortened from 0.814 (SD 0.103) s to 0.452 (SD 0.054) s during this exercise. Of this shortening, 73% was due to shortening of the diastolic period and 27% to shortening of the systolic period. In the relatively small shortening of the mean systolic period [from 0.377 (SD 0.043) s to 0.268 (SD 0.029) s], the isovolumetric contraction time was shortened by 56%. During exercise, the heart rate (fc) increased by 79.4% [from 74.3 (SD 9.3) beats · min −1 to 133.3 (SD 14.8) beats · min −1], and the peak blood velocity (S1) in the common carotid artery increased by 56.1% [from 0.82 (SD 0.10) m · s−1 to 1.28 (SD 0.11) m · s−1]. After exercise, the S1 decreased rapidly to the resting level. The fc decreased more slowly, still being higher than the initial resting level 5 min after exercise. The diastolic velocity wave and the end-diastolic foot decreased during exercise. The blood flow rate in the carotid artery increased transiently by 13.5% at the beginning of exercise [from 5.62 (SD 0.63) ml · s−1 to 6.38 (SD 0.85) ml · s−1] and by 26.5% at the end of the exercise period [from 5.62 (SD 0.63) ml · s−1 to 7.11 (SD 1.34) ml · s−1]. The increase of blood flow in the carotid artery at the onset of exercise may have been mainly related to cerebral activation, and partly to an increase of blood flow to the skin of the head. The physiological significance for cerebral function of the increase of blood flow in the artery after the end of exercise is unknown.
- 9 November 1992
- Published by Elsevier in Biochimica et Biophysica Acta (BBA) - Biomembranes
- Vol. 1111 (2) , 151-158
Different patterns of cell volume regulation in hyposmotic media between attached and suspended HeLa cells
- 9 November 1992
- Published by Elsevier in Biochimica et Biophysica Acta (BBA) - Biomembranes
- Vol. 1111 (2) , 151-158
Different patterns of cell volume regulation in hyposmotic media between attached and suspended HeLa cells