Lisa D. Olsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lisa D. Olsen has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
John S. Zogorski
2 shared publications- Kenneth Belitz
U.S. Geological Survey – Emeritus Carlisle MA
2 shared publications - Miranda S. Fram
US Geological Survey, Sacramento, CA 95819, USA
2 shared publications - Angela P. Paul
Nevada Water Science Center, US Geological Survey, Carson City, USA
1 shared publication - Athena P. Clark1 shared publication
- Brian A. Bergamaschi
U.S. Geological Survey, California Water Science Center, Sacramento, CA 95819, USA
1 shared publication
Latest Publications
- 9 July 2019
- Published by Elsevier in Journal of Hydrology
- Vol. 577, 123939
Comment on “Suspended-sediment concentrations and loads in the lower Mississippi and Atchafalaya Rivers decreased by half between 1980 and 2015” by Scott V. Mize, Jennifer C. Murphy, Timothy H. Diehl, and Dennis K. Demcheck, Journal of Hydrology 564 (2018) 1–11
- 9 July 2019
- Published by Elsevier in Journal of Hydrology
- Vol. 577, 123939
Comment on “Suspended-sediment concentrations and loads in the lower Mississippi and Atchafalaya Rivers decreased by half between 1980 and 2015” by Scott V. Mize, Jennifer C. Murphy, Timothy H. Diehl, and Dennis K. Demcheck, Journal of Hydrology 564 (2018) 1–11
- 1 January 2019
- Published by US Geological Survey
Revisions to suspended-sediment concentration, percent smaller than 0.063 millimeter, and instantaneous suspended-sediment discharge reported for a cooperative program between the U.S. Geological Survey and the U.S. Army Corps of Engineers in the lower Mississippi-Atchafalaya River Basin, October 1989 to February 2015
This report presents revised results for four parameters reported for suspended-sediment samples that were collected in the lower Mississippi-Atchafalaya River Basin as part of a cooperative program between the U.S. Army Corps of Engineers, Mississippi Valley Division, New Orleans District and the U.S. Geological Survey (USGS). The cooperative program has been active since 1973 at seven sites: two sites on the main stem of the Mississippi River, three sites on the Atchafalaya River, one site on the Old River Outflow Channel, and one site on the lower Red River above the confluence with the Old River Outflow Channel. The four parameters—suspended-sediment concentration, percent by mass of the sediment that passes through a 0.063-millimeter (US 230) sieve, instantaneous stream discharge, and instantaneous suspended-sediment discharge—reported for 2,895 samples have been modified to reflect the findings of a full review of the cooperative program, which was initiated by both agencies in January 2015. The revised results are for samples collected from October 1989 through February 2015. Ninety-four percent of the revised values for suspended-sediment concentration are lower than their corresponding original reported values, indicating that less suspended sediment moves through the lower Mississippi River system than was previously reported. For example, the median revised instantaneous suspended-sediment discharge at the Mississippi River at Tarbert Landing, Miss. (USGS station 07295100), was 315,000 short tons per day, compared to 378,000 short tons per day as originally reported. At the Atchafalaya River at Simmesport, La. (USGS station 07381490), the median revised suspended-sediment discharge was 105,000 short tons per day, compared to 143,000 short tons per day as originally reported. The systematic downward revision in instantaneous suspended-sediment discharge values was due to a systematic downward revision in the suspended fine (less than 0.063 millimeter) sediment concentration. The effect of the revision on the suspended-sand concentration and instantaneous suspended-sand discharge was weaker. Any model of sediment load or transport processes in the basin that uses data from the affected samples should be reevaluated on the basis of the revised results.
- 1 January 2019
- Published by US Geological Survey
Revisions to suspended-sediment concentration, percent smaller than 0.063 millimeter, and instantaneous suspended-sediment discharge reported for a cooperative program between the U.S. Geological Survey and the U.S. Army Corps of Engineers in the lower Mississippi-Atchafalaya River Basin, October 1989 to February 2015
This report presents revised results for four parameters reported for suspended-sediment samples that were collected in the lower Mississippi-Atchafalaya River Basin as part of a cooperative program between the U.S. Army Corps of Engineers, Mississippi Valley Division, New Orleans District and the U.S. Geological Survey (USGS). The cooperative program has been active since 1973 at seven sites: two sites on the main stem of the Mississippi River, three sites on the Atchafalaya River, one site on the Old River Outflow Channel, and one site on the lower Red River above the confluence with the Old River Outflow Channel. The four parameters—suspended-sediment concentration, percent by mass of the sediment that passes through a 0.063-millimeter (US 230) sieve, instantaneous stream discharge, and instantaneous suspended-sediment discharge—reported for 2,895 samples have been modified to reflect the findings of a full review of the cooperative program, which was initiated by both agencies in January 2015. The revised results are for samples collected from October 1989 through February 2015. Ninety-four percent of the revised values for suspended-sediment concentration are lower than their corresponding original reported values, indicating that less suspended sediment moves through the lower Mississippi River system than was previously reported. For example, the median revised instantaneous suspended-sediment discharge at the Mississippi River at Tarbert Landing, Miss. (USGS station 07295100), was 315,000 short tons per day, compared to 378,000 short tons per day as originally reported. At the Atchafalaya River at Simmesport, La. (USGS station 07381490), the median revised suspended-sediment discharge was 105,000 short tons per day, compared to 143,000 short tons per day as originally reported. The systematic downward revision in instantaneous suspended-sediment discharge values was due to a systematic downward revision in the suspended fine (less than 0.063 millimeter) sediment concentration. The effect of the revision on the suspended-sand concentration and instantaneous suspended-sand discharge was weaker. Any model of sediment load or transport processes in the basin that uses data from the affected samples should be reevaluated on the basis of the revised results.
- 1 January 2016
- Published by US Geological Survey
Potential sources of analytical bias and error in selected trace element data-quality analyses
First posted September 28, 2016 Chief, Water Science Field Team U.S. Geological Survey 520 North Park Avenue Tucson, Arizona 85721 http://az.water.usgs.gov/ Potential sources of analytical bias and error associated with laboratory analyses for selected trace elements where concentrations were greater in filtered samples than in paired unfiltered samples were evaluated by U.S. Geological Survey (USGS) Water Quality Specialists in collaboration with the USGS National Water Quality Laboratory (NWQL) and the Branch of Quality Systems (BQS). Causes for trace-element concentrations in filtered samples to exceed those in associated unfiltered samples have been attributed to variability in analytical measurements, analytical bias, sample contamination either in the field or laboratory, and (or) sample-matrix chemistry. These issues have not only been attributed to data generated by the USGS NWQL but have been observed in data generated by other laboratories. This study continues the evaluation of potential analytical bias and error resulting from matrix chemistry and instrument variability by evaluating the performance of seven selected trace elements in paired filtered and unfiltered surface-water and groundwater samples collected from 23 sampling sites of varying chemistries from six States, matrix spike recoveries, and standard reference materials. Filtered and unfiltered samples have been routinely analyzed on separate inductively coupled plasma-mass spectrometry instruments. Unfiltered samples are treated with hydrochloric acid (HCl) during an in-bottle digestion procedure; filtered samples are not routinely treated with HCl as part of the laboratory analytical procedure. To evaluate the influence of HCl on different sample matrices, an aliquot of the filtered samples was treated with HCl. The addition of HCl did little to differentiate the analytical results between filtered samples treated with HCl from those samples left untreated; however, there was a small, but noticeable, decrease in the number of instances where a particular trace-element concentration was greater in a filtered sample than in the associated unfiltered sample for all trace elements except selenium. Accounting for the small dilution effect (2 percent) from the addition of HCl, as required for the in-bottle digestion procedure for unfiltered samples, may be one step toward decreasing the number of instances where trace-element concentrations are greater in filtered samples than in paired unfiltered samples. The laboratory analyses of arsenic, cadmium, lead, and zinc did not appear to be influenced by instrument biases. These trace elements showed similar results on both instruments used to analyze filtered and unfiltered samples. The results for aluminum and molybdenum tended to be higher on the instrument designated to analyze unfiltered samples; the results for selenium tended to be lower. The matrices used to prepare calibration standards were different for the two instruments. The instrument designated for the analysis of unfiltered samples was calibrated using standards prepared in a nitric:hydrochloric acid (HNO3:HCl) matrix. The instrument designated for the analysis of filtered samples was calibrated using standards prepared in a matrix acidified only with HNO3. Matrix chemistry may have influenced the responses of aluminum, molybdenum, and selenium on the two instruments. The best analytical practice is to calibrate instruments using calibration standards prepared in matrices that reasonably match those of the samples being analyzed. Filtered and unfiltered samples were spiked over a range of trace-element concentrations from less than 1 to 58 times ambient concentrations. The greater the magnitude of the trace-element spike concentration relative to the ambient concentration, the greater the likelihood spike recoveries will be within data control guidelines (80–120 percent). Greater variability in spike recoveries occurred when trace elements were spiked at concentrations less than 10 times the ambient concentration. Spike recoveries that were considerably lower than 90 percent often were associated with spiked concentrations substantially lower than what was present in the ambient sample. Because the main purpose of spiking natural water samples with known quantities of a particular analyte is to assess possible matrix effects on analytical results, the results of this study stress the importance of spiking samples at concentrations that are reasonably close to what is expected but sufficiently high to exceed analytical variability. Generally, differences in spike recovery results between paired filtered and unfiltered samples were minimal when samples were analyzed on the same instrument. Analytical results for trace-element concentrations in ambient filtered and unfiltered samples greater than 10 and 40 μg/L, respectively, were within the data-quality objective for precision of ±25 percent. Ambient trace-element concentrations in filtered samples greater than the long-term method detection limits but less than 10 μg/L failed to meet the data-quality objective for precision for at least one trace element in about 54 percent of the samples. Similarly, trace-element concentrations in unfiltered samples greater than the long-term method detection limits but less than 40 μg/L failed to meet this data-quality objective for at least one trace-element analysis in about 58 percent of the samples. Although, aluminum and zinc were particularly problematic, limited re-analyses of filtered and unfiltered samples appeared to improve otherwise failed analytical precision. The evaluation of analytical bias using standard reference materials indicate a slight low bias for results for arsenic, cadmium, selenium, and zinc. Aluminum and molybdenum show signs of high bias. There was no observed bias, as determined using the standard reference materials, during the analysis of lead.
- 1 January 2016
- Published by US Geological Survey
Potential sources of analytical bias and error in selected trace element data-quality analyses
First posted September 28, 2016 Chief, Water Science Field Team U.S. Geological Survey 520 North Park Avenue Tucson, Arizona 85721 http://az.water.usgs.gov/ Potential sources of analytical bias and error associated with laboratory analyses for selected trace elements where concentrations were greater in filtered samples than in paired unfiltered samples were evaluated by U.S. Geological Survey (USGS) Water Quality Specialists in collaboration with the USGS National Water Quality Laboratory (NWQL) and the Branch of Quality Systems (BQS). Causes for trace-element concentrations in filtered samples to exceed those in associated unfiltered samples have been attributed to variability in analytical measurements, analytical bias, sample contamination either in the field or laboratory, and (or) sample-matrix chemistry. These issues have not only been attributed to data generated by the USGS NWQL but have been observed in data generated by other laboratories. This study continues the evaluation of potential analytical bias and error resulting from matrix chemistry and instrument variability by evaluating the performance of seven selected trace elements in paired filtered and unfiltered surface-water and groundwater samples collected from 23 sampling sites of varying chemistries from six States, matrix spike recoveries, and standard reference materials. Filtered and unfiltered samples have been routinely analyzed on separate inductively coupled plasma-mass spectrometry instruments. Unfiltered samples are treated with hydrochloric acid (HCl) during an in-bottle digestion procedure; filtered samples are not routinely treated with HCl as part of the laboratory analytical procedure. To evaluate the influence of HCl on different sample matrices, an aliquot of the filtered samples was treated with HCl. The addition of HCl did little to differentiate the analytical results between filtered samples treated with HCl from those samples left untreated; however, there was a small, but noticeable, decrease in the number of instances where a particular trace-element concentration was greater in a filtered sample than in the associated unfiltered sample for all trace elements except selenium. Accounting for the small dilution effect (2 percent) from the addition of HCl, as required for the in-bottle digestion procedure for unfiltered samples, may be one step toward decreasing the number of instances where trace-element concentrations are greater in filtered samples than in paired unfiltered samples. The laboratory analyses of arsenic, cadmium, lead, and zinc did not appear to be influenced by instrument biases. These trace elements showed similar results on both instruments used to analyze filtered and unfiltered samples. The results for aluminum and molybdenum tended to be higher on the instrument designated to analyze unfiltered samples; the results for selenium tended to be lower. The matrices used to prepare calibration standards were different for the two instruments. The instrument designated for the analysis of unfiltered samples was calibrated using standards prepared in a nitric:hydrochloric acid (HNO3:HCl) matrix. The instrument designated for the analysis of filtered samples was calibrated using standards prepared in a matrix acidified only with HNO3. Matrix chemistry may have influenced the responses of aluminum, molybdenum, and selenium on the two instruments. The best analytical practice is to calibrate instruments using calibration standards prepared in matrices that reasonably match those of the samples being analyzed. Filtered and unfiltered samples were spiked over a range of trace-element concentrations from less than 1 to 58 times ambient concentrations. The greater the magnitude of the trace-element spike concentration relative to the ambient concentration, the greater the likelihood spike recoveries will be within data control guidelines (80–120 percent). Greater variability in spike recoveries occurred when trace elements were spiked at concentrations less than 10 times the ambient concentration. Spike recoveries that were considerably lower than 90 percent often were associated with spiked concentrations substantially lower than what was present in the ambient sample. Because the main purpose of spiking natural water samples with known quantities of a particular analyte is to assess possible matrix effects on analytical results, the results of this study stress the importance of spiking samples at concentrations that are reasonably close to what is expected but sufficiently high to exceed analytical variability. Generally, differences in spike recovery results between paired filtered and unfiltered samples were minimal when samples were analyzed on the same instrument. Analytical results for trace-element concentrations in ambient filtered and unfiltered samples greater than 10 and 40 μg/L, respectively, were within the data-quality objective for precision of ±25 percent. Ambient trace-element concentrations in filtered samples greater than the long-term method detection limits but less than 10 μg/L failed to meet the data-quality objective for precision for at least one trace element in about 54 percent of the samples. Similarly, trace-element concentrations in unfiltered samples greater than the long-term method detection limits but less than 40 μg/L failed to meet this data-quality objective for at least one trace-element analysis in about 58 percent of the samples. Although, aluminum and zinc were particularly problematic, limited re-analyses of filtered and unfiltered samples appeared to improve otherwise failed analytical precision. The evaluation of analytical bias using standard reference materials indicate a slight low bias for results for arsenic, cadmium, selenium, and zinc. Aluminum and molybdenum show signs of high bias. There was no observed bias, as determined using the standard reference materials, during the analysis of lead.