Jorge A. Calvo-Sanz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jorge A. Calvo-Sanz has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Alfonso Arias-Puente
INCIVI, Ana Teresa, 24, Optometry and Opthalmology Department, Madrid, Spain
3 shared publicationsFrancisco Poyales
Miranza IOA, Madrid, Optometry and Opthalmology, Complutense University, Madrid, Spain
2 shared publicationsJavier Ruiz-Alcocer
Universidad Europea, Madrid, Spain
2 shared publicationsMiguel A. Sánchez-Tena
Universidad Europea de Madrid, Madrid, Spain
2 shared publicationsAlejandro Portero-Benito
Ophthalmologist, Instituto de Ciencias Visuales, INCIVI, Madrid, Spain
1 shared publicationCarlos E Tapia-Ayuga
Departamento De Física De La Atmósfera Y Astrofísica, Universidad Complutense De Madrid, Madrid, Spain
1 shared publication
Latest Publications
- Open Access
- 28 April 2022
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 70 (5) , 1586-1592
Agreement between the biometric measurements used to calculate the size of the implantable collamer lenses measured with four different technologies
Purpose: To evaluate the agreement between the biometric measurements used to calculate the size of the implantable collamer lenses (ICL) with different technologies: swept-source optical coherence tomography, spectral domain optical coherence tomography, and Scheimpflug tomography. Methods: This retrospective observational study included subjects undergoing refractive surgery with posterior chamber phakic IOL implantation to correct their myopia. The anterior chamber depth (ACD) and the horizontal white to white (WTW) or the angle to angle (ATA) distance were measured with the following four devices: the IOLMaster 700 biometer (Carl Zeiss Meditec, Jena, Germany), based on swept-source optical coherence tomography; the Cirrus and Visante optical coherence tomographs (Carl Zeiss Meditec) based on low-coherence interferometry; and the Pentacam rotating Scheimpflug camera (Oculus, Wetzlar, Germany). Results: In the horizontal corneal diameter measurements, there were statistically significant differences between Pentacam–IOLMaster 700 pair (P < 0.001) and Pentacam–Visante pair (P < 0.001). WTW from CIRRUS showed the lowest correlation when paired with Pentacam and IOLMaster 700 (R 2 = 0.452 and 0.385 for Visante and R 2 = 0.494 and 0.426 for Cirrus). Regarding the linear correlation of the ACD measurements, all pairs of devices were statistically significant and all of them showed a very good correlation index. Conclusion: There is a good agreement between the different devices under evaluation for ACD measurements. As for WTW, the values measured with the different devices showed large discrepancies with low correlation levels, especially when comparing the tomographs with the other devices under evaluation.
- 28 April 2022
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 70 (5) , 1586-1592
Open AccessAgreement between the biometric measurements used to calculate the size of the implantable collamer lenses measured with four different technologies
Purpose: To evaluate the agreement between the biometric measurements used to calculate the size of the implantable collamer lenses (ICL) with different technologies: swept-source optical coherence tomography, spectral domain optical coherence tomography, and Scheimpflug tomography. Methods: This retrospective observational study included subjects undergoing refractive surgery with posterior chamber phakic IOL implantation to correct their myopia. The anterior chamber depth (ACD) and the horizontal white to white (WTW) or the angle to angle (ATA) distance were measured with the following four devices: the IOLMaster 700 biometer (Carl Zeiss Meditec, Jena, Germany), based on swept-source optical coherence tomography; the Cirrus and Visante optical coherence tomographs (Carl Zeiss Meditec) based on low-coherence interferometry; and the Pentacam rotating Scheimpflug camera (Oculus, Wetzlar, Germany). Results: In the horizontal corneal diameter measurements, there were statistically significant differences between Pentacam–IOLMaster 700 pair (P < 0.001) and Pentacam–Visante pair (P < 0.001). WTW from CIRRUS showed the lowest correlation when paired with Pentacam and IOLMaster 700 (R 2 = 0.452 and 0.385 for Visante and R 2 = 0.494 and 0.426 for Cirrus). Regarding the linear correlation of the ACD measurements, all pairs of devices were statistically significant and all of them showed a very good correlation index. Conclusion: There is a good agreement between the different devices under evaluation for ACD measurements. As for WTW, the values measured with the different devices showed large discrepancies with low correlation levels, especially when comparing the tomographs with the other devices under evaluation.
- 2 July 2020
- Published by Taylor & Francis in Chronobiology International
- Vol. 37 (7) , 1016-1022
Blue light emission spectra of popular mobile devices: The extent of user protection against melatonin suppression by built-in screen technology and light filtering software systems
Blue light, with wavelengths shorter than 440–450 nm, is the most energetic radiation of the visible spectrum for the human eye, and its possible multiple effects on the human nervous and other systems have become a line of research by many investigators. The use of mobile devices whose screens emit various amounts of blue light is common nowadays. This study evaluated the efficiency of the blue light screen and control software technologies of eight different mobile devices. Emitted screen spectra of the different mobile devices according to different conditions of blue light emission software control were obtained using a spectrograph, and the derived spectra were compared with the melatonin suppression action spectrum. The amount of blue light emission and predicted melatonin suppression varied according to the unique software control and screen technology of each device. AMOLED screen technology, compared with other screen technologies, achieved better control of blue light emission. The effect of blue light filters depends on the screen technology; however, the melatonin suppression index of mobile devices is not reduced sufficiently by the use of blue light-attenuating software.
- 2 July 2020
- Published by Taylor & Francis in Chronobiology International
- Vol. 37 (7) , 1016-1022
Blue light emission spectra of popular mobile devices: The extent of user protection against melatonin suppression by built-in screen technology and light filtering software systems
Blue light, with wavelengths shorter than 440–450 nm, is the most energetic radiation of the visible spectrum for the human eye, and its possible multiple effects on the human nervous and other systems have become a line of research by many investigators. The use of mobile devices whose screens emit various amounts of blue light is common nowadays. This study evaluated the efficiency of the blue light screen and control software technologies of eight different mobile devices. Emitted screen spectra of the different mobile devices according to different conditions of blue light emission software control were obtained using a spectrograph, and the derived spectra were compared with the melatonin suppression action spectrum. The amount of blue light emission and predicted melatonin suppression varied according to the unique software control and screen technology of each device. AMOLED screen technology, compared with other screen technologies, achieved better control of blue light emission. The effect of blue light filters depends on the screen technology; however, the melatonin suppression index of mobile devices is not reduced sufficiently by the use of blue light-attenuating software.
- Open Access
- 1 January 2020
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 68 (6) , 1073-1078
Clinical application of bicylindric intraocular lens power calculation method
Purpose: To analyze the reliability of the refractive results prediction obtained in intraocular lens (IOL) calculation using bicylindric power calculation method, with the use of steep and flat keratometry readings compared with the classical mean keratometry calculation method. Methods: Fifty-seven eyes of 57 subjects who underwent cataract surgery were included in this prospective study. Optical biometry was performed with IOLMaster 700 and IOL power calculation was performed using both keratometry readings and the surgically induced astigmatism. Four weeks after surgery, subjective refraction was done. Finally, results obtained with both IOL calculation methods were compared. Results: Mean spherical equivalent using bicylindric IOL power calculation method was -0.082 ± 0.296D, and achieved mean spherical equivalent using classical IOL power method with Haigis formula was -0.088 ± 0.405D. Achieved mean spherical equivalent obtained in subjective refraction after surgery was -0.101 ± 0.265D. Linear correlation between bicylindric method spherical equivalent calculation and achieved spherical equivalent was statistically significant (r = 0.761, P < 0.001), also correlation between Haigis spherical equivalent calculation and achieved spherical equivalent was statistically significant (r = 0.339, P = 0.010). Emmetropia was achieved in 49 of 57 (85.86%) subjects and bicylindric method calculated that 49 of 57 (85.86%) of subjects would get emmetropia (P = 1.000). Classical IOL power calculation estimated that 38/57 subjects would get emmetropia (66.67%) (P = 0.026). Conclusion: The IOL power calculation including both keratometry readings and surgically induced astigmatism seems to be more accurate and provides more precision in refractive prediction than classical calculation method.
- 1 January 2020
- Published by Medknow in Indian Journal Of Ophthalmology
- Vol. 68 (6) , 1073-1078
Open AccessClinical application of bicylindric intraocular lens power calculation method
Purpose: To analyze the reliability of the refractive results prediction obtained in intraocular lens (IOL) calculation using bicylindric power calculation method, with the use of steep and flat keratometry readings compared with the classical mean keratometry calculation method. Methods: Fifty-seven eyes of 57 subjects who underwent cataract surgery were included in this prospective study. Optical biometry was performed with IOLMaster 700 and IOL power calculation was performed using both keratometry readings and the surgically induced astigmatism. Four weeks after surgery, subjective refraction was done. Finally, results obtained with both IOL calculation methods were compared. Results: Mean spherical equivalent using bicylindric IOL power calculation method was -0.082 ± 0.296D, and achieved mean spherical equivalent using classical IOL power method with Haigis formula was -0.088 ± 0.405D. Achieved mean spherical equivalent obtained in subjective refraction after surgery was -0.101 ± 0.265D. Linear correlation between bicylindric method spherical equivalent calculation and achieved spherical equivalent was statistically significant (r = 0.761, P < 0.001), also correlation between Haigis spherical equivalent calculation and achieved spherical equivalent was statistically significant (r = 0.339, P = 0.010). Emmetropia was achieved in 49 of 57 (85.86%) subjects and bicylindric method calculated that 49 of 57 (85.86%) of subjects would get emmetropia (P = 1.000). Classical IOL power calculation estimated that 38/57 subjects would get emmetropia (66.67%) (P = 0.026). Conclusion: The IOL power calculation including both keratometry readings and surgically induced astigmatism seems to be more accurate and provides more precision in refractive prediction than classical calculation method.
- Open Access
- 1 January 2020
- Published by Elsevier in Journal of Optometry
- Vol. 13 (1) , 35-40
Characterization of optical performance with defocusing curve: Analysis of two refractive intraocular lens models with high and medium addition
- 1 January 2020
- Published by Elsevier in Journal of Optometry
- Vol. 13 (1) , 35-40
Open AccessCharacterization of optical performance with defocusing curve: Analysis of two refractive intraocular lens models with high and medium addition
- Open Access
- 1 July 2018
- Published by Elsevier in Journal of Optometry
- Vol. 11 (3) , 192-197
Accuracy of Cirrus HD-OCT and Topcon SP-3000P for measuring central corneal thickness
- 1 July 2018
- Published by Elsevier in Journal of Optometry
- Vol. 11 (3) , 192-197
Open AccessAccuracy of Cirrus HD-OCT and Topcon SP-3000P for measuring central corneal thickness
- Open Access
- 1 July 2018
- Published by Elsevier in Journal of Optometry
- Vol. 11 (3) , 199
Reply to: Central corneal thickness measurement with Cirrus HD-OCT and Topcon SP-3000P
- 1 July 2018
- Published by Elsevier in Journal of Optometry
- Vol. 11 (3) , 199
Open AccessReply to: Central corneal thickness measurement with Cirrus HD-OCT and Topcon SP-3000P
- Open Access
- 23 March 2018
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 28 (5) , 559-565
Intraocular lens bicylindric power calculation method: Using both flat and steep K readings to improve intraocular lens power prediction
Purpose: To compare and analyze the accuracy of the refractive outcomes obtained in intraocular lens power calculation using the classical calculation method with mean keratometry (K) and the calculation method with both K meridians presented in this article. Methods: A total of 62 eyes of 62 subjects who were undergoing cataract surgery were included in this study. Optical biometry was performed using mean K and Haigis formula for classical intraocular lens calculation methods to achieve intraocular lens power; 4 weeks after surgery, prior to medical discharge, subjective refraction was made. Alternatively, intraocular lens power was calculated with bicylindric method using both keratometry readings, obtaining spherocylindrical refractive expected outcomes. Finally, results obtained with intraocular lens calculation methods, bicylindric method, and Haigis formula were compared. Results: Spherical equivalent calculated by classical intraocular lens calculation methods using Haigis formula (H-SE) was −0.027 ± 0.115 D and using bicylindric method (B-SE) was −0.080 ± 0.222 D. Achieved spherical equivalent obtained 4 weeks after surgery (A-SE) was −0.144 ± 0.268 D. Difference between H-SE and A-SE was −0.117 D (p = 0.002). Difference between B-SE and A-SE was not significant (−0.054 D, p = 0.109). Analysis in refraction groups showed a positive correlation between A-SE confronted to B-SE and H-SE (r = 0.313; p = 0.013 and r = 0.562; p < 0.001, respectively). This indicated a reliability in ametropic group prediction of 0.767 in H-SE and 0.843 in B-SE. Conclusion: Intraocular lens calculation with bicylindric method could be more accurate and had more reliability than classical intraocular lens calculation method. Bicylindric method adds astigmatism control and provides a reliable expected spherocylindrical refraction.
- 23 March 2018
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 28 (5) , 559-565
Open AccessIntraocular lens bicylindric power calculation method: Using both flat and steep K readings to improve intraocular lens power prediction
Purpose: To compare and analyze the accuracy of the refractive outcomes obtained in intraocular lens power calculation using the classical calculation method with mean keratometry (K) and the calculation method with both K meridians presented in this article. Methods: A total of 62 eyes of 62 subjects who were undergoing cataract surgery were included in this study. Optical biometry was performed using mean K and Haigis formula for classical intraocular lens calculation methods to achieve intraocular lens power; 4 weeks after surgery, prior to medical discharge, subjective refraction was made. Alternatively, intraocular lens power was calculated with bicylindric method using both keratometry readings, obtaining spherocylindrical refractive expected outcomes. Finally, results obtained with intraocular lens calculation methods, bicylindric method, and Haigis formula were compared. Results: Spherical equivalent calculated by classical intraocular lens calculation methods using Haigis formula (H-SE) was −0.027 ± 0.115 D and using bicylindric method (B-SE) was −0.080 ± 0.222 D. Achieved spherical equivalent obtained 4 weeks after surgery (A-SE) was −0.144 ± 0.268 D. Difference between H-SE and A-SE was −0.117 D (p = 0.002). Difference between B-SE and A-SE was not significant (−0.054 D, p = 0.109). Analysis in refraction groups showed a positive correlation between A-SE confronted to B-SE and H-SE (r = 0.313; p = 0.013 and r = 0.562; p < 0.001, respectively). This indicated a reliability in ametropic group prediction of 0.767 in H-SE and 0.843 in B-SE. Conclusion: Intraocular lens calculation with bicylindric method could be more accurate and had more reliability than classical intraocular lens calculation method. Bicylindric method adds astigmatism control and provides a reliable expected spherocylindrical refraction.
- Open Access
- 22 March 2018
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 28 (5) , 573-581
Comparing surgically induced astigmatism calculated by means of simulated keratometry versus total corneal refractive power
Purpose: To evaluate surgically induced astigmatism as computed by means of either simulated keratometry (KSIM) or total corneal refractive power (TCRP) after temporal incisions. Methods: Prospective observational study including 36 right eyes undergoing cataract surgery. Astigmatism was measured preoperatively during the 3-month follow-up period using Pentacam. Surgically induced astigmatism was computed considering anterior corneal surface astigmatism at 3 mm with KSIM and considering both corneal surfaces with TCRP from 1 to 8 mm (TCRP3 for 3 mm). The eyes under study were divided into two balanced groups: LOW with KSIM astigmatism SIM astigmatism ≥0.90 D. Resulting surgically induced astigmatism values were compared across groups and measuring techniques by means of flattening, steepening, and torque analysis. Results: Mean surgically induced astigmatism was higher in the HIGH group (0.31 D @ 102°) than in the LOW group (0.04 D @ 16°). The temporal incision resulted in a steepening in the HIGH group of 0.15 D @ 90°, as estimated with KSIM, versus 0.28 D @ 90° with TCRP3, but no significant differences were found for the steepening in the LOW group or for the torque in either group. Differences between KSIM- and TCRP3-based surgically induced astigmatism values were negligible in LOW group. Conclusion: Surgically induced astigmatism was considerably higher in the high-astigmatism group and its value was underestimated with the KSIM approach. Eyes having low astigmatism should not be included for computing the surgically induced astigmatism because steepening would be underestimated.
- 22 March 2018
- Published by SAGE Publications in European Journal of Ophthalmology
- Vol. 28 (5) , 573-581
Open AccessComparing surgically induced astigmatism calculated by means of simulated keratometry versus total corneal refractive power
Purpose: To evaluate surgically induced astigmatism as computed by means of either simulated keratometry (KSIM) or total corneal refractive power (TCRP) after temporal incisions. Methods: Prospective observational study including 36 right eyes undergoing cataract surgery. Astigmatism was measured preoperatively during the 3-month follow-up period using Pentacam. Surgically induced astigmatism was computed considering anterior corneal surface astigmatism at 3 mm with KSIM and considering both corneal surfaces with TCRP from 1 to 8 mm (TCRP3 for 3 mm). The eyes under study were divided into two balanced groups: LOW with KSIM astigmatism SIM astigmatism ≥0.90 D. Resulting surgically induced astigmatism values were compared across groups and measuring techniques by means of flattening, steepening, and torque analysis. Results: Mean surgically induced astigmatism was higher in the HIGH group (0.31 D @ 102°) than in the LOW group (0.04 D @ 16°). The temporal incision resulted in a steepening in the HIGH group of 0.15 D @ 90°, as estimated with KSIM, versus 0.28 D @ 90° with TCRP3, but no significant differences were found for the steepening in the LOW group or for the torque in either group. Differences between KSIM- and TCRP3-based surgically induced astigmatism values were negligible in LOW group. Conclusion: Surgically induced astigmatism was considerably higher in the high-astigmatism group and its value was underestimated with the KSIM approach. Eyes having low astigmatism should not be included for computing the surgically induced astigmatism because steepening would be underestimated.
- 1 February 2018
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 256 (3) , 559-566
Efficiency and measurements agreement between swept-source OCT and low-coherence interferometry biometry systems
To compare and evaluate the agreement between the measurements obtained with a swept-source optical coherence tomography (OCT)-based biometer, the IOLMaster® 700 (IOLM), and those obtained by an optical biometer based on optical low-coherence interferometry (OLCI), the Aladdin (ALD); To evaluate the ability to perform biometric measurements in those eyes with transparency alterations.
- 1 February 2018
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 256 (3) , 559-566
Efficiency and measurements agreement between swept-source OCT and low-coherence interferometry biometry systems
To compare and evaluate the agreement between the measurements obtained with a swept-source optical coherence tomography (OCT)-based biometer, the IOLMaster® 700 (IOLM), and those obtained by an optical biometer based on optical low-coherence interferometry (OLCI), the Aladdin (ALD); To evaluate the ability to perform biometric measurements in those eyes with transparency alterations.