FDFranck Diaz-Garelli

Franck Diaz-Garelli

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Franck Diaz-Garelli has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Using Continuous Glucose Monitoring Values for Bolus Size Calculation in Smart Multiple Daily Injection Systems: No Negative Impact on Post-bolus Glycemic Outcomes Found in Real-World Data

    by Franck Diaz-Garelli, Aakash Shah, Arthur Mikhno, Pratik Agrawal, Amanda Kinnischtzke, Robert A. Vigersky

    Background: Recent evidence shows that it may be safe to estimate bolus sizes based on continuous glucose monitoring (CGM) rather than blood glucose (BG) values using glycemic trend-adjusted bolus calculators. Users may already be doing this in the real world, though it is unclear whether this is safe or effective for calculators not employing trend adjustment. Methods: We assessed real-world data from a smart multiple daily injections (MDIs) device users with a CGM system, hypothesizing that four-hour post-bolus outcomes using CGM values are not inferior to those using BG values. Our data set included 184 users and spanned 18 months with 79 000 bolus observations. We tested differences using logistic regression predicting CGM or BG value usage based on outcomes and confirmed initial results using a mixed model regression accounting for within-subject correlations. Results: Comparing four-hour outcomes for bolus events using CGM and BG values revealed no differences using our initial approach ( P > .183). This finding was confirmed by our mixed model regression approach in all cases ( P > .199), except for times below range outcomes. Higher times below range were predictive of lower odds of CGM-based bolus calculations (OR = 0.987, P < .0001 and OR = 0.987, P = .0276, for time below 70 and 54 mg/dL, respectively). Conclusions: We found no differences in four-hour post-bolus glycemic outcomes when using CGM or BG except for time below range, which showed evidence of being lower for CGM. Though preliminary, our results confirm prior findings showing non-inferiority of using CGM values for bolus calculation compared with BG usage in the real world.


  • What Oncologists Want: Identifying Challenges and Preferences on Diagnosis Data Entry to Reduce EHR-Induced Burden and Improve Clinical Data Quality

    by Franck Diaz-Garelli, Roy Strowd, Tamjeed Ahmed, Thomas W. Lycan, Sean Daley, Brian J. Wells, Umit Topaloglu

    PURPOSE: Accurate recording of diagnosis (DX) data in electronic health records (EHRs) is important for clinical practice and learning health care. Previous studies show statistically stable patterns of data entry in EHRs that contribute to inaccurate DX, likely because of a lack of data entry support. We conducted qualitative research to characterize the preferences of oncological care providers on cancer DX data entry in EHRs during clinical practice. METHODS: We conducted semistructured interviews and focus groups to uncover common themes on DX data entry preferences and barriers to accurate DX recording. Then, we developed a survey questionnaire sent to a cohort of oncologists to verify the generalizability of our initial findings. We constrained our participants to a single specialty and institution to ensure similar clinical backgrounds and clinical experience with a single EHR system. RESULTS: A total of 12 neuro-oncologists and thoracic oncologists were involved in the interviews and focus groups. The survey developed from these two initial thrusts was distributed to 19 participants yielding a 94.7% survey response rate. Clinicians reported similar user interface experiences, barriers, and dissatisfaction with current DX entry systems including repetitive entry operations, difficulty in finding specific DX options, time-consuming interactions, and the need for workarounds to maintain efficiency. The survey revealed inefficient DX search interfaces and challenging entry processes as core barriers. CONCLUSION: Oncologists seem to be divided between specific DX data entry and time efficiency because of current interfaces and feel hindered by the burdensome and repetitive nature of EHR data entry. Oncologists' top concern for adopting data entry support interventions is ensuring that it provides significant time-saving benefits and increasing workflow efficiency. Future interventions should account for time efficiency, beyond ensuring data entry effectiveness.


  • Open Access

    Vascular mild cognitive impairment and its relationship to hemoglobin A1c levels and apolipoprotein E genotypes in the Dominican Republic

    by Martin Medrano, Gelanys Castro-Tejada, Rafael Lantigua, Gretel Silvestre, Sergio Diaz, Patricia Mota, Franck Diaz-Garelli

    Dementia and vascular mild cognitive impairment (VaMCI) currently impose a tremendous human and economic burden on patients from aging populations and their families worldwide. Understanding the interplay of cardiometabolic risk factors and apolipoprotein E (APOE) may direct us to a more personalized medicine and preventative care in MCI and dementia. Objective: To evaluate the relationship of cardiometabolic risk factors with MCI and assess the APOE genotype’s role in an elderly cohort in the Dominican Republic. Methods: We studied a cohort of 180 participants 65 years of age and older using a combined assessment of cardiometabolic risk factors, neuropsychological battery tests, and APOE genotyping. We used the number of failed tests as a proxy to predict MCI. Results: We found that patients with the ε3-ε4 APOE genotype had 2.91 higher number of failed cognitive tests (p=0.027) compared to patients with the ε3-ε3 genotyped. The rate of test failures increased 10% (p=0.025) per unit increase in HbA1c percentage. Conclusions: Increased Hemoglobin A1c levels and ε3-ε4 APOE genotypes seem to have an association with the development of VaMCI.


  • Workflow Differences Affect Data Accuracy in Oncologic EHRs: A First Step Toward Detangling the Diagnosis Data Babel

    by Franck Diaz-Garelli, Roy Strowd, Virginia L. Lawson, Maria E. Mayorga, Brian J. Wells, Thomas W. Lycan, Umit Topaloglu

    PURPOSE: Diagnosis (DX) information is key to clinical data reuse, yet accessible structured DX data often lack accuracy. Previous research hints at workflow differences in cancer DX entry, but their link to clinical data quality is unclear. We hypothesized that there is a statistically significant relationship between workflow-describing variables and DX data quality. METHODS: We extracted DX data from encounter and order tables within our electronic health records (EHRs) for a cohort of patients with confirmed brain neoplasms. We built and optimized logistic regressions to predict the odds of fully accurate (ie, correct neoplasm type and anatomic site), inaccurate, and suboptimal (ie, vague) DX entry across clinical workflows. We selected our variables based on correlation strength of each outcome variable. RESULTS: Both workflow and personnel variables were predictive of DX data quality. For example, a DX entered in departments other than oncology had up to 2.89 times higher odds of being accurate ( P < .0001) compared with an oncology department; an outpatient care location had up to 98% fewer odds of being inaccurate ( P < .0001), but had 458 times higher odds of being suboptimal ( P < .0001) compared with main campus, including the cancer center; and a DX recoded by a physician assistant had 85% fewer odds of being suboptimal ( P = .005) compared with those entered by physicians. CONCLUSION: These results suggest that differences across clinical workflows and the clinical personnel producing EHR data affect clinical data quality. They also suggest that the need for specific structured DX data recording varies across clinical workflows and may be dependent on clinical information needs. Clinicians and researchers reusing oncologic data should consider such heterogeneity when conducting secondary analyses of EHR data.


  • Open Access

    A tale of three subspecialties: Diagnosis recording patterns are internally consistent but Specialty-Dependent

    by Jose-Franck Diaz-Garelli, Roy Strowd, Tamjeed Ahmed, Brian J Wells, Rebecca Merrill, Javier Laurini, Boris Pasche, Umit Topaloglu

    Structured diagnosis (DX) are crucial for secondary use of electronic health record (EHR) data. However, they are often suboptimally recorded. Our previous work showed initial evidence of variable DX recording patterns in oncology charts even after biopsy records are available. We verified this finding’s internal and external validity. We hypothesized that this recording pattern would be preserved in a larger cohort of patients for the same disease. We also hypothesized that this effect would vary across subspecialties. We extracted DX data from EHRs of patients treated for brain, lung, and pancreatic neoplasms, identified through clinician-led chart reviews. We used statistical methods (i.e., binomial and mixed model regressions) to test our hypotheses. We found variable recording patterns in brain neoplasm DX (i.e., larger number of distinct DX—OR = 2.2, P < 0.0001, higher descriptive specificity scores—OR = 1.4, P < 0.0001—and much higher entropy after the BX—OR = 3.8 P = 0.004 and OR = 8.0, P < 0.0001), confirming our initial findings. We also found strikingly different patterns for lung and pancreas DX. Although both seemed to have much lower DX sequence entropy after the BX—OR = 0.198, P = 0.015 and OR = 0.099, P = 0.015, respectively compared to OR = 3.8 P = 0.004). We also found statistically significant differences between the brain dataset and both the lung (P < 0.0001) and pancreas (0.009<P < 0.08). Our results suggest that disease-specific DX entry patterns exist and are established differently by clinical subspecialty. These differences should be accounted for during clinical data reuse and data quality assessments but also during EHR entry system design to maximize accurate, precise and consistent data entry likelihood.


  • Open Access

    Predicting Current Glycated Hemoglobin Values in Adults: Development of an Algorithm From the Electronic Health Record

    by Brian J Wells, Kristin M Lenoir, Jose-Franck Diaz-Garelli, Wendell Futrell, Elizabeth Lockerman, Kevin M Pantalone, Michael W Kattan

    Clinical informatics, decision support for health professionals, electronic health records, and ehealth infrastructures.


  • Open Access

    Predicting Current Glycated Hemoglobin Values in Adults: Development of an Algorithm From the Electronic Health Record (Preprint)

    by Brian J Wells, Kristin M Lenoir, Jose-Franck Diaz-Garelli, Wendell Futrell, Elizabeth Lockerman, Kevin M Pantalone, Michael W Kattan

    BACKGROUND Electronic, personalized clinical decision support tools to optimize glycated hemoglobin (HbA1c) screening are lacking. Current screening guidelines are based on simple, categorical rules developed for populations of patients. Although personalized diabetes risk calculators have been created, none are designed to predict current glycemic status using structured data commonly available in electronic health records (EHRs). OBJECTIVE The goal of this project was to create a mathematical equation for predicting the probability of current elevations in HbA1c (≥5.7%) among patients with no history of hyperglycemia using readily available variables that will allow integration with EHR systems. METHODS The reduced model was compared head-to-head with calculators created by Baan and Griffin. Ten-fold cross-validation was used to calculate the bias-adjusted prediction accuracy of the new model. Statistical analyses were performed in R version 3.2.5 (The R Foundation for Statistical Computing) using the rms (Regression Modeling Strategies) package. RESULTS The final model to predict an elevated HbA1c based on 22,635 patient records contained the following variables in order from most to least importance according to their impact on the discriminating accuracy of the model: age, body mass index, random glucose, race, serum non–high-density lipoprotein, serum total cholesterol, estimated glomerular filtration rate, and smoking status. The new model achieved a concordance statistic of 0.77 which was statistically significantly better than prior models. The model appeared to be well calibrated according to a plot of the predicted probabilities versus the prevalence of the outcome at different probabilities. CONCLUSIONS The calculator created for predicting the probability of having an elevated HbA1c significantly outperformed the existing calculators. The personalized prediction model presented in this paper could improve the efficiency of HbA1c screening initiatives.