Paola Verde
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Paola Verde has a total of 108 co-authors. Here are the top co-authors by number of shared publications:
- Pietro Varilone
Dipartimento di Ingegneria Elettrica e dell’Informazione, Università di Cassino e del LM, 03043 Cassino, Italy
34 shared publications - Pierluigi Caramia
Department of Engineering, University of Napoli Parthenope, Naples, Italy
30 shared publications - Guido Carpinelli
University of Naples Federico II, Naples, Italy
27 shared publications - Angela Russo
Energy Department, Politecnico di Torino, 10129 Torino, Italy
15 shared publications P. Caramia
Dip. di Ingegneria, Univ. Parthenope, Napoli, Italia
9 shared publications- Michele De Santis
Department of Engineering, University of Campania Luigi Vanvitelli, 81031 Aversa, Italy
8 shared publications
Latest Publications
- Open Access
- 6 January 2026
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 174
Orthogonal arrays-based method for the probabilistic voltage stability analysis of unbalanced power systems
- 6 January 2026
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 174
Open AccessOrthogonal arrays-based method for the probabilistic voltage stability analysis of unbalanced power systems
- Open Access
- 1 January 2026
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2026 (1) , 5771828
Polynomial Normal Transformations and Quasi‐Monte Carlo Method for Probabilistic Voltage Stability Analysis
The inherent randomness of renewable and demand powers has significantly increased the importance of probabilistic techniques in the operation and planning of power systems. In this context, the paper introduces a novel approach for probabilistic voltage stability analysis in unbalanced power systems. We employ the polynomial normal transformations (PNTs) to accurately model input variable uncertainties. PNT’s versatility allows it to represent a wide range of probability distributions and effectively handle complex correlations among random variables. To enhance computational efficiency without sacrificing essential statistical information, the PNT is integrated with quasi‐Monte Carlo simulation, which usually offers a significantly faster convergence rate compared to Monte Carlo methods. To quantify the operational limits of voltage stability, a nonlinear optimization model subject to a set of constraints is utilized. The model (i) employs complementarity constraints to manage the PV‐to‐PQ transition resulting from generator reactive power saturation and (ii) incorporates the direction of load power increments, thereby capturing the specific pattern of load demand growth across the network. Numerical simulations on a representative system validate the proposed method’s effectiveness. A series of analyses were conducted, varying both the representation of the random input data (using predefined probability distributions like normal and Weibull as well as measured input data) and the PNT order to find the most adequate one. Comparisons against the classical Monte Carlo approach and the point estimate method confirm the robust performance of the adopted methodology.
- 1 January 2026
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2026 (1) , 5771828
Open AccessPolynomial Normal Transformations and Quasi‐Monte Carlo Method for Probabilistic Voltage Stability Analysis
The inherent randomness of renewable and demand powers has significantly increased the importance of probabilistic techniques in the operation and planning of power systems. In this context, the paper introduces a novel approach for probabilistic voltage stability analysis in unbalanced power systems. We employ the polynomial normal transformations (PNTs) to accurately model input variable uncertainties. PNT’s versatility allows it to represent a wide range of probability distributions and effectively handle complex correlations among random variables. To enhance computational efficiency without sacrificing essential statistical information, the PNT is integrated with quasi‐Monte Carlo simulation, which usually offers a significantly faster convergence rate compared to Monte Carlo methods. To quantify the operational limits of voltage stability, a nonlinear optimization model subject to a set of constraints is utilized. The model (i) employs complementarity constraints to manage the PV‐to‐PQ transition resulting from generator reactive power saturation and (ii) incorporates the direction of load power increments, thereby capturing the specific pattern of load demand growth across the network. Numerical simulations on a representative system validate the proposed method’s effectiveness. A series of analyses were conducted, varying both the representation of the random input data (using predefined probability distributions like normal and Weibull as well as measured input data) and the PNT order to find the most adequate one. Comparisons against the classical Monte Carlo approach and the point estimate method confirm the robust performance of the adopted methodology.
- Open Access
Probabilistic Estimation of During-Fault Voltages of Unbalanced Active Distribution: Methods and Tools
In low-voltage (LV) distribution networks, system operating conditions are always unbalanced due to the unpredictability of the load demand in each phase, coupled with a potentially asymmetrical network structure due to different phase conductors’ sizes and lengths. The widespread diffusion of distributed generators (DGs) among network users has significantly contributed to reducing the overall load of the electrical system, but at the cost of making voltages slightly more unbalanced. In this article, an LV distribution test network equipped with several single-phase DGs has been considered, and all During-Fault Voltages (DFVs) have been studied, according to each possible type of short circuit. To provide a measure of the asymmetry of unsymmetrical voltage dips, three different indices based on the symmetrical components of the voltages have been considered; moreover, the Monte Carlo simulation (MCS) method has allowed for studying faults and asymmetries in a probabilistic manner. Through the probability density functions (pdfs) of the DFVs, it has been possible to assess the impact of single-phase DGs on the asymmetry of bus voltages due to short-circuits.
Open AccessProbabilistic Estimation of During-Fault Voltages of Unbalanced Active Distribution: Methods and Tools
In low-voltage (LV) distribution networks, system operating conditions are always unbalanced due to the unpredictability of the load demand in each phase, coupled with a potentially asymmetrical network structure due to different phase conductors’ sizes and lengths. The widespread diffusion of distributed generators (DGs) among network users has significantly contributed to reducing the overall load of the electrical system, but at the cost of making voltages slightly more unbalanced. In this article, an LV distribution test network equipped with several single-phase DGs has been considered, and all During-Fault Voltages (DFVs) have been studied, according to each possible type of short circuit. To provide a measure of the asymmetry of unsymmetrical voltage dips, three different indices based on the symmetrical components of the voltages have been considered; moreover, the Monte Carlo simulation (MCS) method has allowed for studying faults and asymmetries in a probabilistic manner. Through the probability density functions (pdfs) of the DFVs, it has been possible to assess the impact of single-phase DGs on the asymmetry of bus voltages due to short-circuits.
- Open Access
- 25 July 2025
- Published by UK Zhende Publishing Limited Company in Renewable Energy and Power Quality Journal
- Vol. 23 (3) , 104-109
On the Aggregated Modelling of Large-Scale Wind Farms for Harmonic Studies
In this paper, the aggregated modelling of large-scalewind farms for harmonic studies is considered. The limitations of the harmonic emission assessment based on the IEC 61000-3-6 summation rule are analysed in a probabilistic framework. An iterative probabilistic procedure based on the Quasi Monte Carlo technique is proposed and applied to a simplified electromagnetic transient model of an exemplary wind power plant. Then, detailed results obtained are used to quantify the above mentioned limitations of the summation rule.
- 25 July 2025
- Published by UK Zhende Publishing Limited Company in Renewable Energy and Power Quality Journal
- Vol. 23 (3) , 104-109
Open AccessOn the Aggregated Modelling of Large-Scale Wind Farms for Harmonic Studies
In this paper, the aggregated modelling of large-scalewind farms for harmonic studies is considered. The limitations of the harmonic emission assessment based on the IEC 61000-3-6 summation rule are analysed in a probabilistic framework. An iterative probabilistic procedure based on the Quasi Monte Carlo technique is proposed and applied to a simplified electromagnetic transient model of an exemplary wind power plant. Then, detailed results obtained are used to quantify the above mentioned limitations of the summation rule.
- Open Access
- 20 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 34409-34434
Modeling and Control of AC Microgrids Under Unbalanced Utility Grid Voltage Using the Invariant-Ellipsoid Method
The increasing penetration of renewable microgrids (MGs) into utility grids (UGs) has introduced new stability and power quality challenges, especially under the unbalanced voltage of the utility grid. This paper presents a novel approach for modelling and controlling AC microgrids (MGs) influenced by unbalanced utility grid voltages, emphasizing inverter-based resources (IBRs). The proposed control design is based on the application of the invariant-ellipsoid method for disturbance rejection. In the presence of asymmetrical power exchange between the microgrid and utility grid, a negative-sequence rejection strategy is applied to ensure that the power transactions remain balanced. This study investigates two operational modes: (1) the MG feeds power to the UG (grid forming), and (2) the opposite mode (grid feeding). A simulation verification was conducted to assess the performance of the invariant-ellipsoid disturbance rejection method. Additionally, a comparison between the proposed invariant-ellipsoid tracker and a traditional H∞ control strategy highlights the efficacy of the former in mitigating UG unbalanced voltage issues while reducing computational complexity. The results demonstrate that the invariant-ellipsoid approach provides robust performance under various unbalanced scenarios with improved dynamic response and reduced oscillations in the delivered power.
- 20 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 34409-34434
Open AccessModeling and Control of AC Microgrids Under Unbalanced Utility Grid Voltage Using the Invariant-Ellipsoid Method
The increasing penetration of renewable microgrids (MGs) into utility grids (UGs) has introduced new stability and power quality challenges, especially under the unbalanced voltage of the utility grid. This paper presents a novel approach for modelling and controlling AC microgrids (MGs) influenced by unbalanced utility grid voltages, emphasizing inverter-based resources (IBRs). The proposed control design is based on the application of the invariant-ellipsoid method for disturbance rejection. In the presence of asymmetrical power exchange between the microgrid and utility grid, a negative-sequence rejection strategy is applied to ensure that the power transactions remain balanced. This study investigates two operational modes: (1) the MG feeds power to the UG (grid forming), and (2) the opposite mode (grid feeding). A simulation verification was conducted to assess the performance of the invariant-ellipsoid disturbance rejection method. Additionally, a comparison between the proposed invariant-ellipsoid tracker and a traditional H∞ control strategy highlights the efficacy of the former in mitigating UG unbalanced voltage issues while reducing computational complexity. The results demonstrate that the invariant-ellipsoid approach provides robust performance under various unbalanced scenarios with improved dynamic response and reduced oscillations in the delivered power.
- Open Access
- 23 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 11, 690-702
Harmonic and Supra-Harmonic Emissions of Electric Vehicle Chargers: Modeling and Cumulative Impact Indices
The analysis of power quality disturbances in distribution systems has gained significance with the diffusion of electric vehicles (EVs). Waveform distortions are interesting since EV currents introduce distortions with spectral components in both low and high-frequency bands. This paper develops specific indices to assess cumulative emissions from single-phase EV on-board chargers, extending the aggregation and diversity factors to the supra-harmonic range. The methodology accounts for variables such as EV charging powers, upstream network impedance, and number of EVs. A simplified time-domain model of a low-power unidirectional converter, commonly used for EV battery charging, is employed to balance circuit complexity and computational effort. This model allows for sensitivity analyses of key parameters influencing charger emissions. Numerical applications are carried out for both individuals and groups of EV chargers at a charging station. Results highlight the need for careful quantification of aggregated EV emissions, showing that supra-harmonic emissions are highly sensitive to variations in the power absorbed by EV chargers. Notably, their cumulative impact is much lower when chargers operate at different power levels than when all chargers operate at the same power level. These findings underscore the importance of accurately assessing the impact of EV charging on power quality.
- 23 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 11, 690-702
Open AccessHarmonic and Supra-Harmonic Emissions of Electric Vehicle Chargers: Modeling and Cumulative Impact Indices
The analysis of power quality disturbances in distribution systems has gained significance with the diffusion of electric vehicles (EVs). Waveform distortions are interesting since EV currents introduce distortions with spectral components in both low and high-frequency bands. This paper develops specific indices to assess cumulative emissions from single-phase EV on-board chargers, extending the aggregation and diversity factors to the supra-harmonic range. The methodology accounts for variables such as EV charging powers, upstream network impedance, and number of EVs. A simplified time-domain model of a low-power unidirectional converter, commonly used for EV battery charging, is employed to balance circuit complexity and computational effort. This model allows for sensitivity analyses of key parameters influencing charger emissions. Numerical applications are carried out for both individuals and groups of EV chargers at a charging station. Results highlight the need for careful quantification of aggregated EV emissions, showing that supra-harmonic emissions are highly sensitive to variations in the power absorbed by EV chargers. Notably, their cumulative impact is much lower when chargers operate at different power levels than when all chargers operate at the same power level. These findings underscore the importance of accurately assessing the impact of EV charging on power quality.
- Open Access
- 24 October 2024
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 162
Optimal siting and sizing of battery energy storage systems in unbalanced distribution systems: A multi objective problem under uncertainty
- 24 October 2024
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 162
Open AccessOptimal siting and sizing of battery energy storage systems in unbalanced distribution systems: A multi objective problem under uncertainty
- Open Access
- 6 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 11, 231-240
Measured Rare Voltage Sags and Clusters of Sags: Prediction Models Driven by the Intermittence Indices
The field measurement campaigns have revealed that voltage sags also occur as clusters and not only as rare phenomena. The clusters of sags represent a stochastic process due to their time dependence; the rare satisfy the requirements for a Poisson distribution process. To forecast both kinds of sags using the statistics of the measurements, different approaches are required. In this study, a general method for predicting both types of sags is proposed with a procedure that can be implemented automatically. The method uses intermittent indices to distinguish between the sites that have a prevalent number of rare sags and the sites where rare sags and clusters occurred. Based on this means of identification, the technique offers two distinct models for predicting each kind of sag. The final goal is to implement the procedure in a measurement system that can automatically pre-analyze the recorded sags and choose the best technique for prediction depending on the type of sag. The first results were satisfying with forecast errors reduced in comparison with those obtained without the proposed procedure.
- 6 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 11, 231-240
Open AccessMeasured Rare Voltage Sags and Clusters of Sags: Prediction Models Driven by the Intermittence Indices
The field measurement campaigns have revealed that voltage sags also occur as clusters and not only as rare phenomena. The clusters of sags represent a stochastic process due to their time dependence; the rare satisfy the requirements for a Poisson distribution process. To forecast both kinds of sags using the statistics of the measurements, different approaches are required. In this study, a general method for predicting both types of sags is proposed with a procedure that can be implemented automatically. The method uses intermittent indices to distinguish between the sites that have a prevalent number of rare sags and the sites where rare sags and clusters occurred. Based on this means of identification, the technique offers two distinct models for predicting each kind of sag. The final goal is to implement the procedure in a measurement system that can automatically pre-analyze the recorded sags and choose the best technique for prediction depending on the type of sag. The first results were satisfying with forecast errors reduced in comparison with those obtained without the proposed procedure.
- Open Access
- 26 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 10, 349-350
Editorial Special Section on “Power Quality in the Energy Transition: Selected Papers From ICHQP 2022”
Electrical power quality is a vital aspect when designing or assessing the operation of all modern power systems and forms an important part of the ongoing energy transition to more efficient and multi-vector systems. However, the ongoing proliferation and changing functionality of power electronic devices, coupled with new grid operating paradigms, such as renewable energy sources integration, microgrids, low-voltage dc distribution networks, and the large-scale integration of electric vehicles, present unique opportunities and challenges for grid operators the world over and require new assessment methods and fresh perspectives on the role of power quality.
- 26 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 10, 349-350
Open AccessEditorial Special Section on “Power Quality in the Energy Transition: Selected Papers From ICHQP 2022”
Electrical power quality is a vital aspect when designing or assessing the operation of all modern power systems and forms an important part of the ongoing energy transition to more efficient and multi-vector systems. However, the ongoing proliferation and changing functionality of power electronic devices, coupled with new grid operating paradigms, such as renewable energy sources integration, microgrids, low-voltage dc distribution networks, and the large-scale integration of electric vehicles, present unique opportunities and challenges for grid operators the world over and require new assessment methods and fresh perspectives on the role of power quality.
- 20 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (2) , 1252-1263
Indices of Intermittence to Improve the Forecasting of the Voltage Sags Measured in Real Systems
This paper provides a means of forecasting the future average performance a regional electric power system in terms of sags per year based on data accumulated over a four-year period. The paper also presents statistical analyses of the measured data. The sags measured in real systems consist of both rare voltage sags and grouped voltage sags (clusters); clusters are stochastic events that must be detected and removed to allow the estimation of the future performance based on a Poisson process. To detect and remove the clusters, new site indices of intermittence are proposed. These indices were measured in every site at which clusters were present, and the measurements included the frequency, time of grouping, and the large number of sags that constituted them. The performance of the forecast was evaluated by comparing the results obtained using the proposed indices with the results derived using a time filter equal for every site. The results showed that the forecast of the rare voltage using a few years' worth of field data had acceptable errors and was not prohibitive. The main aspect, which must be investigated further, is related to the choice of the best threshold on the intermittence site indices.
- 20 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (2) , 1252-1263
Indices of Intermittence to Improve the Forecasting of the Voltage Sags Measured in Real Systems
This paper provides a means of forecasting the future average performance a regional electric power system in terms of sags per year based on data accumulated over a four-year period. The paper also presents statistical analyses of the measured data. The sags measured in real systems consist of both rare voltage sags and grouped voltage sags (clusters); clusters are stochastic events that must be detected and removed to allow the estimation of the future performance based on a Poisson process. To detect and remove the clusters, new site indices of intermittence are proposed. These indices were measured in every site at which clusters were present, and the measurements included the frequency, time of grouping, and the large number of sags that constituted them. The performance of the forecast was evaluated by comparing the results obtained using the proposed indices with the results derived using a time filter equal for every site. The results showed that the forecast of the rare voltage using a few years' worth of field data had acceptable errors and was not prohibitive. The main aspect, which must be investigated further, is related to the choice of the best threshold on the intermittence site indices.