Thomas A. Berk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thomas A. Berk has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Beiping Qiang
Schulich Heart Centre, Sunnybrook Health Sciences Center, 2075 Bayview Avenue, Room D-406, Toronto, ON, M4N 3M5, Canada
2 shared publications - Bradley H. Strauss
Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5, Canada; Temerty Faculty of Medicine, University of Toronto, 1 King's College Circle, Toronto, Ontario M5S 1A8, Canada; Schulich Heart Centre, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5, Canada
2 shared publications - Graham A. Wright
Department of Medical Biophysics, University of Toronto, Toronto, Canada
2 shared publications - Michelle Ladouceur-Wodzak
Schulich Heart Centre, Sunnybrook Health Sciences Center, 2075 Bayview Avenue, Room D-406, Toronto, ON, M4N 3M5, Canada
2 shared publications Patrick T. Yang
Department of Ophthalmology and Vision Sciences, University of Toronto Toronto, ON, Canada
2 shared publications- Xiuling Qi
Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON, Canada
2 shared publications
Latest Publications
- Open Access
- 19 December 2024
- Published by Elsevier in American Journal of Ophthalmology Case Reports
- Vol. 37, 102240
Persistent bilateral sclerouveitis following bimatoprost implantation and removal
- 19 December 2024
- Published by Elsevier in American Journal of Ophthalmology Case Reports
- Vol. 37, 102240
Open AccessPersistent bilateral sclerouveitis following bimatoprost implantation and removal
- 1 June 2017
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 26 (6) , e194-e195
Prospective Comparative Analysis of 4 Different Intraocular Pressure Measurement Techniques and Their Effects on Pressure Readings
- 1 June 2017
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 26 (6) , e194-e195
Prospective Comparative Analysis of 4 Different Intraocular Pressure Measurement Techniques and Their Effects on Pressure Readings
- 1 October 2016
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 25 (10) , e897-e904
Prospective Comparative Analysis of 4 Different Intraocular Pressure Measurement Techniques and Their Effects on Pressure Readings
Purpose: To compare intraocular pressure (IOP) measurement using the Goldmann applanation tonometry (GAT) without fluorescein, with fluorescein strips, with fluorescein droplets, and IOP measurement with Tono-Pen Avia (TPA). Patients and Methods: This was a prospective comparative clinical analysis. It was performed in clinical practice. The study population consisted of 40 volunteer patients, 1 eye per patient. All patients who were 18 years and older having routine ophthalmological examination were eligible to participate. Active corneal abrasions and/or ulcers, previous glaucoma surgery, or prostheses interfering with GAT measurement were excluded. GAT IOP was measured first without fluorescein, then with fluorescein strip, then with fluorescein droplet, and finally with the TPA device. The main outcome measure was central corneal IOP. Results: Mean±SD IOP measurements for GAT without fluorescein, with fluorescein strip, with fluorescein droplet, and for TPA groups were 12.65±3.01, 14.70±2.82, 15.78±2.64, and 16.33±3.08 mm Hg, respectively. Repeated-measures analysis of variance corrected with the Greenhouse-Geisser estimate (ɛ=0.732) showed that measuring technique had a significant effect on IOP measurements (F 2.20,85.59=34.66, PP≤0.001) between all techniques except when GAT with fluorescein droplet was compared with TPA (P=0.222). The Bland-Altman analyses showed 95% limits of agreement maximum potential discrepancies in measurement ranging from 5.89 mm Hg in the GAT with fluorescein strip versus droplet compared with 11.83 mm Hg in the GAT with fluorescein strip versus TPA comparison. Conclusions: IOP measurement technique significantly impacted the values obtained. The ophthalmologist should ensure consistent measurement technique to minimize variability when following patients.
- 1 October 2016
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 25 (10) , e897-e904
Prospective Comparative Analysis of 4 Different Intraocular Pressure Measurement Techniques and Their Effects on Pressure Readings
Purpose: To compare intraocular pressure (IOP) measurement using the Goldmann applanation tonometry (GAT) without fluorescein, with fluorescein strips, with fluorescein droplets, and IOP measurement with Tono-Pen Avia (TPA). Patients and Methods: This was a prospective comparative clinical analysis. It was performed in clinical practice. The study population consisted of 40 volunteer patients, 1 eye per patient. All patients who were 18 years and older having routine ophthalmological examination were eligible to participate. Active corneal abrasions and/or ulcers, previous glaucoma surgery, or prostheses interfering with GAT measurement were excluded. GAT IOP was measured first without fluorescein, then with fluorescein strip, then with fluorescein droplet, and finally with the TPA device. The main outcome measure was central corneal IOP. Results: Mean±SD IOP measurements for GAT without fluorescein, with fluorescein strip, with fluorescein droplet, and for TPA groups were 12.65±3.01, 14.70±2.82, 15.78±2.64, and 16.33±3.08 mm Hg, respectively. Repeated-measures analysis of variance corrected with the Greenhouse-Geisser estimate (ɛ=0.732) showed that measuring technique had a significant effect on IOP measurements (F 2.20,85.59=34.66, PP≤0.001) between all techniques except when GAT with fluorescein droplet was compared with TPA (P=0.222). The Bland-Altman analyses showed 95% limits of agreement maximum potential discrepancies in measurement ranging from 5.89 mm Hg in the GAT with fluorescein strip versus droplet compared with 11.83 mm Hg in the GAT with fluorescein strip versus TPA comparison. Conclusions: IOP measurement technique significantly impacted the values obtained. The ophthalmologist should ensure consistent measurement technique to minimize variability when following patients.
- 1 March 2015
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 41 (3) , 674-680
Electron microscopic evaluation of a gold glaucoma micro shunt after explantation
We present a case of an explanted gold glaucoma micro shunt (GMS Plus) and the subsequent light and electron microscopic analyses. The shunt was implanted in a patient with medically refractive glaucoma. The intraocular pressure (IOP) was stable at 12 mm Hg 6 months postoperatively but spiked to 26 mm Hg 6 months later; membranous growth was visible on the implant gonioscopically. A second gold micro shunt was placed 2 years after the first. The IOP was 7 mm Hg 1 week postoperatively but increased to 23 mm Hg 3 weeks later; similar membranous growth was visible on this implant. One of the shunts was explanted, and light and scanning electron microscopic analyses revealed encapsulation around the shunt exterior and connective tissue invasion of the microstructure. This represents the first electron microscopic analysis of an explanted gold glaucoma micro shunt and the first unequivocal images of the fibrotic pseudo-capsule traversing its microchannels and fenestrations. Dr. Ahmed is a consultant to and has received research grants from Solx, Inc. No other author has a financial or proprietary interest in any material or method mentioned.
- 1 March 2015
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 41 (3) , 674-680
Electron microscopic evaluation of a gold glaucoma micro shunt after explantation
We present a case of an explanted gold glaucoma micro shunt (GMS Plus) and the subsequent light and electron microscopic analyses. The shunt was implanted in a patient with medically refractive glaucoma. The intraocular pressure (IOP) was stable at 12 mm Hg 6 months postoperatively but spiked to 26 mm Hg 6 months later; membranous growth was visible on the implant gonioscopically. A second gold micro shunt was placed 2 years after the first. The IOP was 7 mm Hg 1 week postoperatively but increased to 23 mm Hg 3 weeks later; similar membranous growth was visible on this implant. One of the shunts was explanted, and light and scanning electron microscopic analyses revealed encapsulation around the shunt exterior and connective tissue invasion of the microstructure. This represents the first electron microscopic analysis of an explanted gold glaucoma micro shunt and the first unequivocal images of the fibrotic pseudo-capsule traversing its microchannels and fenestrations. Dr. Ahmed is a consultant to and has received research grants from Solx, Inc. No other author has a financial or proprietary interest in any material or method mentioned.
- 1 March 2015
- Published by Elsevier in Atherosclerosis
- Vol. 239 (1) , 232-239
Pharmacogenomic interaction between the Haptoglobin genotype and vitamin E on atherosclerotic plaque progression and stability
- 1 March 2015
- Published by Elsevier in Atherosclerosis
- Vol. 239 (1) , 232-239
Pharmacogenomic interaction between the Haptoglobin genotype and vitamin E on atherosclerotic plaque progression and stability
- Open Access
- 1 January 2015
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 17 (1) , 106
Distal coronary embolization following acute myocardial infarction increases early infarct size and late left ventricular wall thinning in a porcine model
- 1 January 2015
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 17 (1) , 106
Open AccessDistal coronary embolization following acute myocardial infarction increases early infarct size and late left ventricular wall thinning in a porcine model
- 1 July 2014
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 10 (3) , 329-336
Unexpected calcification after direct intravascular injection of autologous bone marrow-derived cells in a chronic total occlusion model
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 July 2014
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 10 (3) , 329-336
Unexpected calcification after direct intravascular injection of autologous bone marrow-derived cells in a chronic total occlusion model
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)