Darach O. H-Ici
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Darach O. H-Ici has a total of 90 co-authors. Here are the top co-authors by number of shared publications:
- Felix Berger
Department of Congenital Heart Disease—Pediatric Cardiology, Deutsches Herzzentrum der Charité, Augustenburger Platz 1, 13353 Berlin, Germany
9 shared publications Titus Kuehne
German Heart Institute Berlin, Department of Congenital Heart Disease and Pediatric Cardiology, Berlin, Germany
8 shared publicationsJérôme Garot
7 shared publications- Daniel R. Messroghli
Deutsches Herzzentrum Berlin
6 shared publications Thomas Hovasse
5 shared publicationsBrian Zakhem
Centre for Cardiovascular Therapeutics, Melbourne, Australia
4 shared publications
Latest Publications
- Open Access
- 1 January 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 18 (1) , 19-7
Myocardial T1 maps reflect histological findings in acute and chronic stages of myocarditis in a rat model
- 1 January 2016
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 18 (1) , 19-7
Open AccessMyocardial T1 maps reflect histological findings in acute and chronic stages of myocarditis in a rat model
- 7 October 2015
- Published by Wiley in NMR in Biomedicine
- Vol. 28 (12) , 1625-1633
Alterations in creatine metabolism observed in experimental autoimmune myocarditis using ex vivo proton magic angle spinning MRS
Experimental autoimmune myocarditis (EAM) in rodents is an accepted model of myocarditis and dilated cardiomyopathy (DCM). Altered metabolism is thought to play an important role in the pathogenesis of DCM and heart failure (HF). Study of the metabolism may provide new diagnostic information and insights into the mechanisms of myocarditis and HF. Proton MRS (1H‐MRS) has not yet been used to study the changes occurring in myocarditis and subsequent HF. We aimed to explore the changes in creatine metabolism using this model and compare them with the findings in healthy animals.Myocardial function of male young Lewis rats with EAM was quantified by performing left ventricular ejection fraction (LVEF) analysis in short‐axis cine images throughout the whole heart. Inflammatory cellular infiltrate was assessed by immunohistochemistry. Myocardial tissue was analyzed using ex vivo proton magic angle spinning MRS (1H‐MAS‐MRS).Myocarditis was confirmed histologically by the presence of an inflammatory cellular infiltrate and CD68 positive staining. A significant increase in the metabolic ratio of Tau/tCr (taurine/total creatine) obtained by 1H‐MAS‐MRS was observed in myocarditis compared with healthy controls (21 d acute EAM, 4.38 (±0.23); 21 d control, 2.84 (±0.08); 35 d chronic EAM, 4.47 (±0.83); 35 d control, 2.59 (±0.38); P < 0.001). LVEF was reduced in diseased animals (EAM, 55.2% (±11.3%); control, 72.6% (±3.8%); P < 0.01) and correlated with Tau/tCr ratio (R = 0.937, P < 0.001).Metabolic alterations occur acutely with the development of myocarditis. Myocardial Tau/tCr ratio as detected by 1H‐MRS correlates with LVEF and is able to differentiate between healthy myocardium and myocardium from rats with EAM. Copyright © 2015 John Wiley & Sons, Ltd.
- 7 October 2015
- Published by Wiley in NMR in Biomedicine
- Vol. 28 (12) , 1625-1633
Alterations in creatine metabolism observed in experimental autoimmune myocarditis using ex vivo proton magic angle spinning MRS
Experimental autoimmune myocarditis (EAM) in rodents is an accepted model of myocarditis and dilated cardiomyopathy (DCM). Altered metabolism is thought to play an important role in the pathogenesis of DCM and heart failure (HF). Study of the metabolism may provide new diagnostic information and insights into the mechanisms of myocarditis and HF. Proton MRS (1H‐MRS) has not yet been used to study the changes occurring in myocarditis and subsequent HF. We aimed to explore the changes in creatine metabolism using this model and compare them with the findings in healthy animals.Myocardial function of male young Lewis rats with EAM was quantified by performing left ventricular ejection fraction (LVEF) analysis in short‐axis cine images throughout the whole heart. Inflammatory cellular infiltrate was assessed by immunohistochemistry. Myocardial tissue was analyzed using ex vivo proton magic angle spinning MRS (1H‐MAS‐MRS).Myocarditis was confirmed histologically by the presence of an inflammatory cellular infiltrate and CD68 positive staining. A significant increase in the metabolic ratio of Tau/tCr (taurine/total creatine) obtained by 1H‐MAS‐MRS was observed in myocarditis compared with healthy controls (21 d acute EAM, 4.38 (±0.23); 21 d control, 2.84 (±0.08); 35 d chronic EAM, 4.47 (±0.83); 35 d control, 2.59 (±0.38); P < 0.001). LVEF was reduced in diseased animals (EAM, 55.2% (±11.3%); control, 72.6% (±3.8%); P < 0.01) and correlated with Tau/tCr ratio (R = 0.937, P < 0.001).Metabolic alterations occur acutely with the development of myocarditis. Myocardial Tau/tCr ratio as detected by 1H‐MRS correlates with LVEF and is able to differentiate between healthy myocardium and myocardium from rats with EAM. Copyright © 2015 John Wiley & Sons, Ltd.
- 23 February 2015
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 26 (2) , 306-314
Cardiac MRI in patients with complex CHD following primary or secondary implantation of MRI-conditional pacemaker system
Objectives: In patients with CHD, cardiac MRI is often indicated for functional and anatomical assessment. With the recent introduction of MRI-conditional pacemaker systems, cardiac MRI has become accessible for patients with pacemakers. The present clinical study aims to evaluate safety, susceptibility artefacts, and image reading of cardiac MRI in patients with CHD and MRI-conditional pacemaker systems.Material and methods: CHD patients with MRI-conditional pacemaker systems and a clinical need for cardiac MRI were examined with a 1.5-T MRI system. Lead function was tested before and after MRI. Artefacts and image readings were evaluated using a four-point grading scale.Results: A total of nine patients with CHD (mean age 34.0 years, range 19.5–53.6 years) received a total of 11 cardiac MRI examinations. Owing to clinical indications, seven patients had previously been converted from conventional to MRI-conditional pacemaker systems. All MRI examinations were completed without adverse effects. Device testing immediately after MRI and at follow-up showed no alteration of pacemaker device and lead function. Clinical questions could be addressed and answered in all patients.Conclusion: Cardiac MRI can be performed safely with high certainty of diagnosis in CHD patients with MRI-conditional pacemaker systems. In case of clinically indicated lead and box changing, CHD patients with non-MRI-conditional pacemaker systems should be considered for complete conversion to MRI-conditional systems.
- 23 February 2015
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 26 (2) , 306-314
Cardiac MRI in patients with complex CHD following primary or secondary implantation of MRI-conditional pacemaker system
Objectives: In patients with CHD, cardiac MRI is often indicated for functional and anatomical assessment. With the recent introduction of MRI-conditional pacemaker systems, cardiac MRI has become accessible for patients with pacemakers. The present clinical study aims to evaluate safety, susceptibility artefacts, and image reading of cardiac MRI in patients with CHD and MRI-conditional pacemaker systems.Material and methods: CHD patients with MRI-conditional pacemaker systems and a clinical need for cardiac MRI were examined with a 1.5-T MRI system. Lead function was tested before and after MRI. Artefacts and image readings were evaluated using a four-point grading scale.Results: A total of nine patients with CHD (mean age 34.0 years, range 19.5–53.6 years) received a total of 11 cardiac MRI examinations. Owing to clinical indications, seven patients had previously been converted from conventional to MRI-conditional pacemaker systems. All MRI examinations were completed without adverse effects. Device testing immediately after MRI and at follow-up showed no alteration of pacemaker device and lead function. Clinical questions could be addressed and answered in all patients.Conclusion: Cardiac MRI can be performed safely with high certainty of diagnosis in CHD patients with MRI-conditional pacemaker systems. In case of clinically indicated lead and box changing, CHD patients with non-MRI-conditional pacemaker systems should be considered for complete conversion to MRI-conditional systems.
- Open Access
- 1 January 2015
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 17 (1) , 78
Cardiovascular magnetic resonance predictors of clinical outcome in patients with suspected acute myocarditis
- 1 January 2015
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 17 (1) , 78
Open AccessCardiovascular magnetic resonance predictors of clinical outcome in patients with suspected acute myocarditis
- 4 October 2014
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 31 (1) , 115-121
Closed-chest small animal model to study myocardial infarction in an MRI environment in real time
Current models for real time study of the effects of myocardial ischemia/reperfusion have major limitations and confounders. Confounders include the surgical stresses of a thoracotomy and abnormal physiology of an open chest. The need to reposition the animal interferes with the study of the early changes associated with ischemia. Direct comparison of pre-ischemia and post-ischemia images is then difficult. We developed a novel “closed chest” model of ischemia/reperfusion to overcome these issues. Following thoracotomy, we sutured a balloon occluder to the left coronary artery of male Sprague–Dawley rats. We used both visual inspection and ECG to assess for successful occlusion and reperfusion of the coronary artery at the time of operation by brief inflation and deflation of the balloon. The tubing was then placed under the skin and the incision closed. Following a recovery period (5–10 days), the animals underwent MRI. We performed baseline assessment of left ventricle function, and repeated LV measurement during a 15-min coronary occlusion and again during a 60-min reperfusion period following reopening of the coronary artery. The occluder was successfully placed in 40 of 44 animals. Four developed intraoperative complications; two large myocardial infarction, two terminal bleeding. Six died in the week following surgery, [four sudden deaths (presumed arrhythmic), one anterior infarction, one sepsis]. Cine-MRI demonstrated localised hypokinesia in 31 of the remaining 34 animals. LV ejection fraction (EF) was reduced from 63 ± 7 % at baseline, to 49 ± 9 % during coronary occlusion. LV EF recovered to 61 ± 2 %. The area at risk on staining of the heart was 41.9 ± 15.8 %. This method allows the effects of ischemia/reperfusion to be studied before, during, and after coronary occlusion. Ischemia can be caused while the animal is in the MRI. This new and clinically relevant small animal model is a valuable tool to study the effects of single or repeated coronary occlusion/reperfusion in real-time.
- 4 October 2014
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 31 (1) , 115-121
Closed-chest small animal model to study myocardial infarction in an MRI environment in real time
Current models for real time study of the effects of myocardial ischemia/reperfusion have major limitations and confounders. Confounders include the surgical stresses of a thoracotomy and abnormal physiology of an open chest. The need to reposition the animal interferes with the study of the early changes associated with ischemia. Direct comparison of pre-ischemia and post-ischemia images is then difficult. We developed a novel “closed chest” model of ischemia/reperfusion to overcome these issues. Following thoracotomy, we sutured a balloon occluder to the left coronary artery of male Sprague–Dawley rats. We used both visual inspection and ECG to assess for successful occlusion and reperfusion of the coronary artery at the time of operation by brief inflation and deflation of the balloon. The tubing was then placed under the skin and the incision closed. Following a recovery period (5–10 days), the animals underwent MRI. We performed baseline assessment of left ventricle function, and repeated LV measurement during a 15-min coronary occlusion and again during a 60-min reperfusion period following reopening of the coronary artery. The occluder was successfully placed in 40 of 44 animals. Four developed intraoperative complications; two large myocardial infarction, two terminal bleeding. Six died in the week following surgery, [four sudden deaths (presumed arrhythmic), one anterior infarction, one sepsis]. Cine-MRI demonstrated localised hypokinesia in 31 of the remaining 34 animals. LV ejection fraction (EF) was reduced from 63 ± 7 % at baseline, to 49 ± 9 % during coronary occlusion. LV EF recovered to 61 ± 2 %. The area at risk on staining of the heart was 41.9 ± 15.8 %. This method allows the effects of ischemia/reperfusion to be studied before, during, and after coronary occlusion. Ischemia can be caused while the animal is in the MRI. This new and clinically relevant small animal model is a valuable tool to study the effects of single or repeated coronary occlusion/reperfusion in real-time.
- Open Access
- 23 February 2014
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 15 (6) , 597-602
T1 mapping in ischaemic heart disease
A unique feature of cardiac magnetic resonance is its ability to characterize myocardium. Proton relaxation times, T1, T2, and T2* are a reflection of the composition of individual tissues, and change in the presence of disease. Research into T1 mapping has largely been focused in the study of cardiomyopathies, but T1 mapping also shows huge potential in the study of ischaemic heart disease. In fact, the first cardiac T1 maps were used to characterize myocardial infarction. Robust high-resolution myocardial T1 mapping is now available for use as a clinical tool. This quantitative technique is simple to perform and analyse, minimally subjective, and highly reproducible. This review aims to summarize the present state of research on the topic, and to show the clinical potential of this method to aid the diagnosis and treatment of patients with ischaemic heart disease.
- 23 February 2014
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 15 (6) , 597-602
Open AccessT1 mapping in ischaemic heart disease
A unique feature of cardiac magnetic resonance is its ability to characterize myocardium. Proton relaxation times, T1, T2, and T2* are a reflection of the composition of individual tissues, and change in the presence of disease. Research into T1 mapping has largely been focused in the study of cardiomyopathies, but T1 mapping also shows huge potential in the study of ischaemic heart disease. In fact, the first cardiac T1 maps were used to characterize myocardial infarction. Robust high-resolution myocardial T1 mapping is now available for use as a clinical tool. This quantitative technique is simple to perform and analyse, minimally subjective, and highly reproducible. This review aims to summarize the present state of research on the topic, and to show the clinical potential of this method to aid the diagnosis and treatment of patients with ischaemic heart disease.
- 11 January 2014
- Published by Wiley in Acta Physiologica
- Vol. 210 (4) , 889-898
Mortality and morbidity in different immunization protocols for experimental autoimmune myocarditis in rats
Aim We aimed to investigate the histological and clinical presentations of experimental autoimmune myocarditis (EAM) induced by different immunization schemes. Methods Male young Lewis rats were divided into five groups immunized by porcine myocardial myosin: subcutaneously (SC) 2 mg (in two 1‐mg doses on day 0 and 7), 0 mg (sham group) subcutaneously into rear footpads (RF), 0.25 mg RF, 0.5 mg RF or 1 mg RF (all RF once on day 0). On day 21, left ventricular (LV) function was assessed by cardiac magnetic resonance imaging and cardiac catheterization. The type and degree of myocardial inflammatory infiltrates were determined by conventional histology and immunohistochemistry. Results In the SC immunized rats and in the RF sham group, we observed 0% mortality, while in the actively RF immunized rats, mortality was 20, 20 and 44% for the 0.25 mg, 0.5 mg and 1 mg myosin doses respectively. Morbidity as defined by inflammatory infiltrates on haematoxylin and eosin (HE) staining was 22% in the SC immunized rats, 0% in the RF sham group and 100% in all actively RF immunized groups. We observed augmented relative ventricle weight and spleen weight, increased LV end‐diastolic pressure, reduced LV developed pressure and reduced LV ejection fraction in all with myosin‐immunized RF groups without any systematic dose effect. Conclusion Subcutaneous immunization to the neck and flanks did not induce a reproducible EAM, while RF myosin administration reliably led to EAM. Lower myosin doses seem to induce the complete histological and clinical picture of EAM while being associated with lower mortality, non‐specific symptoms and animal distress.
- 11 January 2014
- Published by Wiley in Acta Physiologica
- Vol. 210 (4) , 889-898
Mortality and morbidity in different immunization protocols for experimental autoimmune myocarditis in rats
Aim We aimed to investigate the histological and clinical presentations of experimental autoimmune myocarditis (EAM) induced by different immunization schemes. Methods Male young Lewis rats were divided into five groups immunized by porcine myocardial myosin: subcutaneously (SC) 2 mg (in two 1‐mg doses on day 0 and 7), 0 mg (sham group) subcutaneously into rear footpads (RF), 0.25 mg RF, 0.5 mg RF or 1 mg RF (all RF once on day 0). On day 21, left ventricular (LV) function was assessed by cardiac magnetic resonance imaging and cardiac catheterization. The type and degree of myocardial inflammatory infiltrates were determined by conventional histology and immunohistochemistry. Results In the SC immunized rats and in the RF sham group, we observed 0% mortality, while in the actively RF immunized rats, mortality was 20, 20 and 44% for the 0.25 mg, 0.5 mg and 1 mg myosin doses respectively. Morbidity as defined by inflammatory infiltrates on haematoxylin and eosin (HE) staining was 22% in the SC immunized rats, 0% in the RF sham group and 100% in all actively RF immunized groups. We observed augmented relative ventricle weight and spleen weight, increased LV end‐diastolic pressure, reduced LV developed pressure and reduced LV ejection fraction in all with myosin‐immunized RF groups without any systematic dose effect. Conclusion Subcutaneous immunization to the neck and flanks did not induce a reproducible EAM, while RF myosin administration reliably led to EAM. Lower myosin doses seem to induce the complete histological and clinical picture of EAM while being associated with lower mortality, non‐specific symptoms and animal distress.
- Open Access
- 19 July 2013
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 77,p. e50397
Assessment of Cardiac Function and Myocardial Morphology Using Small Animal Look-locker Inversion Recovery (SALLI) MRI in Rats
Small animal magnetic resonance imaging is an important tool to study cardiac function and changes in myocardial tissue. The high heart rates of small animals (200 to 600 beats/min) have previously limited the role of CMR imaging. Small animal Look-Locker inversion recovery (SALLI) is a T1 mapping sequence for small animals to overcome this problem 1. T1 maps provide quantitative information about tissue alterations and contrast agent kinetics. It is also possible to detect diffuse myocardial processes such as interstitial fibrosis or edema 1-6. Furthermore, from a single set of image data, it is possible to examine heart function and myocardial scarring by generating cine and inversion recovery-prepared late gadolinium enhancement-type MR images 1. The presented video shows step-by-step the procedures to perform small animal CMR imaging. Here it is presented with a healthy Sprague-Dawley rat, however naturally it can be extended to different cardiac small animal models.
- 19 July 2013
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 77,p. e50397
Open AccessAssessment of Cardiac Function and Myocardial Morphology Using Small Animal Look-locker Inversion Recovery (SALLI) MRI in Rats
Small animal magnetic resonance imaging is an important tool to study cardiac function and changes in myocardial tissue. The high heart rates of small animals (200 to 600 beats/min) have previously limited the role of CMR imaging. Small animal Look-Locker inversion recovery (SALLI) is a T1 mapping sequence for small animals to overcome this problem 1. T1 maps provide quantitative information about tissue alterations and contrast agent kinetics. It is also possible to detect diffuse myocardial processes such as interstitial fibrosis or edema 1-6. Furthermore, from a single set of image data, it is possible to examine heart function and myocardial scarring by generating cine and inversion recovery-prepared late gadolinium enhancement-type MR images 1. The presented video shows step-by-step the procedures to perform small animal CMR imaging. Here it is presented with a healthy Sprague-Dawley rat, however naturally it can be extended to different cardiac small animal models.
- Open Access
- 1 January 2013
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 15 (1) , P28
Assessment of acute myocardial ischemia with unenhanced T1 mapping MR imaging
- 1 January 2013
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 15 (1) , P28
Open AccessAssessment of acute myocardial ischemia with unenhanced T1 mapping MR imaging
- Open Access
- 1 February 2012
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 14 (S1) , P289
Optimized assessment of both left and right ventricular parameters from multi-slice acquisitions of single orientations using reconstructed 3D cine data
- 1 February 2012
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 14 (S1) , P289
Open AccessOptimized assessment of both left and right ventricular parameters from multi-slice acquisitions of single orientations using reconstructed 3D cine data