    Knowledge‐based deep residual U‐Net (DRU) for synthetic CT generation using a single MR volume for frameless radiosurgery

    by Xiwen Shu, Ke Lu, Jingtong Zhao, John Ginn, Yongbok Kim, Zhenyu Yang, Justus Adamson, Trey Mullikin, Chunhao Wang

    Purpose: To develop a knowledge‐based deep model for sCT generation from a single MR volume in LINAC‐based frameless SRS, enabling the MR‐only workflow without extra CT simulation. Methods: A total of 139 patients were included in the study, with 120 used for training and 19 for testing. A Deep Residual U‐Net(DRU) was developed to generate sCT from patient‐specific high‐resolution T1 + Contrast MR volume, complemented by a healthy brain CT volume from the Visible Human Project that provides CT‐specific anatomical knowledge. To simulate treatment conditions, a template immobilization mask was deformed to align with the patient‐specific sCT anatomy, thereby creating a full sCT F volume. Four metrics, including PSNR, SSIM, RMSE, and MAE were derived to evaluate Hounsfield units(HU) accuracy of sCT compared to the ground‐truth CT without immobilization masks. Single isocenter multi‐target SRS plans developed with volumetric modulated arc therapy (VMAT) technique were recalculated within sCT F volumes to produce simulated dose distributions, which were compared with clinical plan dose distributions using the mean dose difference in the planning target volume(PTV) and gamma index evaluation. Results: In the test set, the generated sCT (statistics are reported as mean ± standard deviation) achieved a PSNR(Peak Signal‐to‐Noise Ratio) of 75 ± 4 dB, Structural Similarity Index (SSIM) of 0.99 ± 0.01, root mean square error (RMSE) of 11.9 ± 5.8 HU, and mean average error (MAE) of 1.4 ± 0.8 HU for brain tissues. When comparing sCT F dose calculation results against the original plans, gamma index passing rates were 95.8 ± 4.2% for the entire volume and 84.4 ± 15.0% within PTVs, using 3%/1 mm/15% threshold criteria. The median/ interquartile range of PTV dose differences were –2.0% and 2.3%, with all discrepancies below –5.0%. Conclusion: This study successfully demonstrated the generation and validation of sCT images from single‐modality MRI using a knowledge‐based deep model. The results confirm that single‐modality MRI without simulation CT scan effectively supports frameless SRS planning and integrates seamlessly into current clinical workflows.

  • An Explainable Deep Model for Risk Scoring and Accurate Radionecrosis Identification Following Brain Metastasis Stereotactic Radiosurgery

    by Jingtong Zhao, Eugene Vaios, Evan Calabrese, Zhenyu Yang, John Ginn, Ariel Gonzalez, Scott Floyd, Zachary J. Reitman, Peter Fecci, John Kirkpatrick, et al.

  • Open Access

    A Radiogenomic Deep Ensemble Learning Model for Identifying Radionecrosis Following Brain Metastases (BM) Stereotactic Radiosurgery in Patients With Non-small Cell Lung Cancer BM

    by Jingtong Zhao, Eugene Vaios, Evan Calabrese, Zhenyu Yang, Scott Robertson, John Ginn, Ke Lu, Fang-Fang Yin, Zachary Reitman, John Kirkpatrick, et al.


  • Open Access

    Quality Management for Radiation Oncology In-House Software Products

    by Sua Yoo, Phillip Antoine, Chunhao Wang, Yang Sheng, Q. Jackie Wu, Joseph Kowalski, Qiuwen Wu, Fang-Fang Yin, William Giles

    (1) Objective: To develop and implement an in-house software quality management (ISQM) program to ensure the continuous, consistent quality of in-house software products. (2) Methods: The ISQM program consists of two key components: quality assurance (QA) and comprehensive documentation. The QA component involves code review, acceptance testing, commissioning, and routine quality checks. Documentation requirements encompass a product report, user manual, QA procedures and reports, release notes, version control, and logs. For each software product, the QA process must be completed, and all required documentation must be finalized before clinical deployment. (3) Results: The ISQM program was successfully developed and retrospectively implemented for existing software products. Future software products will adhere to the ISQM framework, ensuring compliance before clinical release. (4) Conclusions: This study demonstrates the successful development and implementation of the ISQM program—a standardized framework for managing the quality of in-house software products. The ISQM program ensures continuous and consistent oversight, playing a critical role in guaranteeing safe and high-quality patient care in the field of radiation oncology.


  • Total brain dose estimation in single‐isocenter‐multiple‐targets (SIMT) radiosurgery via a novel deep neural network with spherical convolutions

    by Zhenyu Yang, Mercedeh Khazaieli, Eugene Vaios, Rihui Zhang, Jingtong Zhao, Trey Mullikin, Albert Yang, Fang‐Fang Yin, Chunhao Wang

    Background and Purpose: Accurate prediction of normal brain dosimetric parameters is crucial for the quality control of single‐isocenter multi‐target (SIMT) stereotactic radiosurgery (SRS) treatment planning. Reliable dose estimation of normal brain tissue is one of the great indicators to evaluate plan quality and is used as a reference in clinics to improve potentially SIMT SRS treatment planning quality consistency. This study aimed to develop a spherical coordinate‐defined deep learning model to predict the dose to a normal brain for SIMT SRS treatment planning. Methods: By encapsulating the human brain within a sphere, 3D volumetric data of planning target volume (PTVs) can be projected onto this geometry as a 2D spherical representation (in azimuthal and polar angles). A novel deep learning model spherical convolutional neural network (SCNN) was developed based on spherical convolution to predict brain dosimetric evaluators from spherical representation. Utilizing 106 SIMT cases, the model was trained to predict brain V50%, V60%, and V66.7%, corresponding to V10Gy and V12Gy, as key dosimetric indicators. The model prediction performance was evaluated using the coefficient of determination ( R 2 ), mean absolute error (MAE), and mean absolute percentage error (MAPE). Results: The SCNN accurately predicted normal brain dosimetric values from the modeled spherical PTV representation, with R 2 scores of 0.92 ± 0.05/0.94 ± 0.10/0.93 ± 0.09 for V50%/V60%/V66.7%, respectively. MAEs values were 1.94 ± 1.61 cc/1.23 ± 0.98 cc/1.13 ± 0.99 cc, and MAPEs were 19.79 ± 20.36%/20.79 ± 21.07%/21.15 ± 22.24%, respectively. Conclusions: The deep learning model provides treatment planners with accurate prediction of dose to normal brain, enabling improved consistency in treatment planning quality. This method can be extended to other brain‐related analyses as an efficient data dimension reduction method.

  • Open Access

    Uncertainty quantification in multi-parametric MRI-based meningioma radiotherapy target segmentation

    by Lana Wang, Zhenyu Yang, Dominic LaBella, Zachary Reitman, John Ginn, Jingtong Zhao, Justus Adamson, Kyle Lafata, Evan Calabrese, John Kirkpatrick, et al.

    Purpose: This work investigates the use of a spherical projection-based U-Net (SPU-Net) segmentation model to improve meningioma segmentation performance and allow for uncertainty quantification.Methods: A total of 76 supratentorial meningioma patients treated with radiotherapy were studied. Gross tumor volumes (GTVs) were contoured by a single experienced radiation oncologist on high-resolution contrast-enhanced T1 MRI scans (T1ce), and both T1 and T1ce images were utilized for segmentation. SPU-Net, an adaptation of U-Net incorporating spherical image projection to map 2D images onto a spherical surface, was proposed. As an equivalence of a nonlinear image transform, projections enhance locoregional details while maintaining the global field of view. By employing multiple projection centers, SPU-Net generates various GTV segmentation predictions, the variance indicating the model’s uncertainty. This uncertainty is quantified on a pixel-wise basis using entropy calculations and aggregated through Otsu’s method for a final segmentation.Results/conclusion: The SPU-Net model poses an advantage over traditional U-Net models by providing a quantitative method of displaying segmentation uncertainty. Regarding segmentation performance, SPU-Net demonstrated comparable results to a traditional U-Net in sensitivity (0.758 vs. 0.746), Dice similarity coefficient (0.760 vs. 0.742), reduced mean Hausdorff distance (mHD) (0.612 cm vs 0.744 cm), and reduced 95% Hausdorff distance (HD95) (2.682 cm vs 2.912 cm). SPU-Net not only is comparable to U-Net in segmentation performance but also offers a significant advantage by providing uncertainty quantification. The added SPU-Net uncertainty mapping revealed low uncertainty in accurate segments (e.g., within GTV or healthy tissue) and higher uncertainty in problematic areas (e.g., GTV boundaries, dural tail), providing valuable insights for potential manual corrections. This advancement is particularly valuable given the complex extra-axial nature of meningiomas and involvement with dural tissue. The capability to quantify uncertainty makes SPU-Net a more advanced and informative tool for segmentation, without sacrificing performance.


  • Dose-Incorporated Deep Ensemble Learning for Improving Brain Metastasis Stereotactic Radiosurgery Outcome Prediction

    by Jingtong Zhao, Eugene Vaios, Yuqi Wang, Zhenyu Yang, Yunfeng Cui, Zachary J. Reitman, Kyle J. Lafata, Peter Fecci, John Kirkpatrick, Fang- Fang Yin, et al.


  • Prognostic value of different discretization parameters in 18fluorodeoxyglucose positron emission tomography radiomics of oropharyngeal squamous cell carcinoma

    by Breylon A. Riley, Jack B. Stevens, Xiang Li, Zhenyu Yang, Chunhao Wang, Yvonne Marie Mowery, David M. Brizel, Fang-Fang Yin, Kyle J. Lafata

    PurposeWe aim to interrogate the role of positron emission tomography (PET) image discretization parameters on the prognostic value of radiomic features in patients with oropharyngeal cancer.ApproachA prospective clinical trial (NCT01908504) enrolled patients with oropharyngeal squamous cell carcinoma (N=69; mixed HPV status) undergoing definitive radiotherapy and evaluated intra-treatment 18fluorodeoxyglucose PET as a potential imaging biomarker of early metabolic response. The primary tumor volume was manually segmented by a radiation oncologist on PET/CT images acquired two weeks into treatment (20 Gy). From this, 54 radiomic texture features were extracted. Two image discretization techniques—fixed bin number (FBN) and fixed bin size (FBS)—were considered to evaluate systematic changes in the bin number ({32, 64, 128, 256} gray levels) and bin size ({0.10, 0.15, 0.22, 0.25} bin-widths). For each discretization-specific radiomic feature space, an LASSO-regularized logistic regression model was independently trained to predict residual and/or recurrent disease. The model training was based on Monte Carlo cross-validation with a 20% testing hold-out, 50 permutations, and minor-class up-sampling to account for imbalanced outcomes data. Performance differences among the discretization-specific models were quantified via receiver operating characteristic curve analysis. A final parameter-optimized logistic regression model was developed by incorporating different settings parameterizations into the same model.ResultsFBN outperformed FBS in predicting residual and/or recurrent disease. The four FBN models achieved AUC values of 0.63, 0.61, 0.65, and 0.62 for 32, 64, 128, and 256 gray levels, respectively. By contrast, the average AUC of the four FBS models was 0.53. The parameter-optimized model, comprising features joint entropy (FBN = 64) and information measure correlation 1 (FBN = 128), achieved an AUC of 0.70. Kaplan–Meier analyses identified these features to be associated with disease-free survival (p=0.0158 and p=0.0180, respectively; log-rank test).ConclusionsOur findings suggest that the prognostic value of individual radiomic features may depend on feature-specific discretization parameter settings.


  • A radiomics-incorporated deep ensemble learning model for multi-parametric MRI-based glioma segmentation

    by Yang Chen, Zhenyu Yang, Jingtong Zhao, Justus Adamson, Yang Sheng, Fang-Fang Yin, Chunhao Wang

    Objective. To develop a deep ensemble learning (DEL) model with radiomics spatial encoding execution for improved glioma segmentation accuracy using multi-parametric magnetic resonance imaging (mp-MRI). Approach. This model was developed using 369 glioma patients with a four-modality mp-MRI protocol: T1, contrast-enhanced T1 (T1-Ce), T2, and FLAIR. In each modality volume, a 3D sliding kernel was implemented across the brain to capture image heterogeneity: 56 radiomic features were extracted within the kernel, resulting in a fourth-order tensor. Each radiomic feature can then be encoded as a 3D image volume, namely a radiomic feature map (RFM). For each patient, all RFMs extracted from all four modalities were processed using principal component analysis for dimension reduction, and the first four principal components (PCs) were selected. Next, a DEL model comprised of four U-Net sub-models was trained for the segmentation of a region-of-interest: each sub-model utilizes the mp-MRI and one of the four PCs as a five-channel input for 2D execution. Last, four softmax probability results given by the DEL model were superimposed and binarized using Otsu’s method as the segmentation results. Three DEL models were trained to segment the enhancing tumor (ET), tumor core (TC), and whole tumor (WT), respectively. The segmentation results given by the proposed ensemble were compared to the mp-MRI-only U-Net results. Main Results. All three radiomics-incorporated DEL models were successfully implemented: compared to the mp-MRI-only U-net results, the dice coefficients of ET (0.777 → 0.817), TC (0.742 → 0.757), and WT (0.823 → 0.854) demonstrated improvement. The accuracy, sensitivity, and specificity results demonstrated similar patterns. Significance. The adopted radiomics spatial encoding execution enriches the image heterogeneity information that leads to the successful demonstration of the proposed DEL model, which offers a new tool for mp-MRI-based medical image segmentation.


  • Open Access

    Quantifying U-Net Uncertainty in Multi-Parametric MRI-based Glioma Segmentation by Spherical Image Projection

    by Zhenyu Yang, Kyle Lafata, Eugene Vaios, Zongsheng Hu, Trey Mullikin, Fang-Fang Yin, Chunhao Wang

    The projection of planar MRI data onto a spherical surface is equivalent to a nonlinear image transformation that retains global anatomical information. By incorporating this image transformation process in our proposed spherical projection-based U-Net (SPU-Net) segmentation model design, multiple independent segmentation predictions can be obtained from a single MRI. The final segmentation is the average of all available results, and the variation can be visualized as a pixel-wise uncertainty map. An uncertainty score was introduced to evaluate and compare the performance of uncertainty measurements. The proposed SPU-Net model was implemented on the basis of 369 glioma patients with MP-MRI scans (T1, T1-Ce, T2, and FLAIR). Three SPU-Net models were trained to segment enhancing tumor (ET), tumor core (TC), and whole tumor (WT), respectively. The SPU-Net model was compared with (1) the classic U-Net model with test-time augmentation (TTA) and (2) linear scaling-based U-Net (LSU-Net) segmentation models in terms of both segmentation accuracy (Dice coefficient, sensitivity, specificity, and accuracy) and segmentation uncertainty (uncertainty map and uncertainty score). The developed SPU-Net model successfully achieved low uncertainty for correct segmentation predictions (e.g., tumor interior or healthy tissue interior) and high uncertainty for incorrect results (e.g., tumor boundaries). This model could allow the identification of missed tumor targets or segmentation errors in U-Net. Quantitatively, the SPU-Net model achieved the highest uncertainty scores for three segmentation targets (ET/TC/WT): 0.826/0.848/0.936, compared to 0.784/0.643/0.872 using the U-Net with TTA and 0.743/0.702/0.876 with the LSU-Net (scaling factor = 2). The SPU-Net also achieved statistically significantly higher Dice coefficients, underscoring the improved segmentation accuracy.