MBMikhail E. Belov

Mikhail E. Belov

*This is an algorithmically generated author record based on publicly available information.

Mikhail E. Belov has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • MALDI-2-Enabled Oversampling for the Mass Spectrometry Imaging of Metabolites at Single-Cell Resolution

    by Jayden C. McKinnon, Rachelle Balez, Reuben S.E. Young, Mikayla L. Brown, Jeremy S. Lum, Liam Robinson, Mikhail E. Belov, Lezanne Ooi, Sara Tortorella, Todd W. Mitchell, et al.

    Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) can provide valuable insights into the metabolome of complex biological systems such as organ tissues and cells. However, obtaining metabolite data at single-cell spatial resolutions presents a few technological challenges. Generally, spatial resolution is defined by the increment the sample stage moves between laser ablation spots. Stage movements less than the diameter of the focused laser beam (i.e., oversampling) can improve spatial resolution; however, such oversampling conditions result in a reduction in sensitivity. To overcome this, we combine an oversampling approach with laser postionization (MALDI-2), which allows for both higher spatial resolution and improved analyte ionization efficiencies. This approach provides significant enhancements to sensitivity for various metabolite classes (e.g., amino acids, purines, carbohydrates etc.), with mass spectral intensities from 6 to 8 μm pixel sizes (from a laser spot size of ∼13 μm) being commensurate with or higher than those obtained by conventional MALDI at 20 μm pixel sizes for many different metabolites. This technique has been used to map the distribution of metabolites throughout mouse spinal cord tissue to observe how metabolite localizations change throughout specific anatomical regions, such as those distributed to the somatosensory area of the dorsal horn, white matter, gray matter, and ventral horn. Furthermore, this method is utilized for single-cell metabolomics of human iPSC-derived astrocytes at 10 μm pixel sizes whereby many different metabolites, including nucleotides, were detected from individual cells while providing insight into cellular localizations.


  • Design and Performance of a Soft-Landing Instrument for Fragment Ion Deposition

    by Hugo Y. Samayoa-Oviedo, Kay-Antonio Behrend, Sebastian Kawa, Harald Knorke, Pei Su, Mikhail E. Belov, Gordon Anderson, Jonas Warneke, Julia Laskin

    We report the development of a new high-flux electrospray ionization-based instrument for soft landing of mass-selected fragment ions onto surfaces. Collision-induced dissociation is performed in a collision cell positioned after the dual electrodynamic ion funnel assembly. The high duty cycle of the instrument enables high-coverage deposition of mass-selected fragment ions onto surfaces at a defined kinetic energy. This capability facilitates the investigation of the reactivity of gaseous fragment ions in the condensed phase. We demonstrate that the observed reactions of deposited fragment ions are dependent on the structure of the ion and the composition of either ionic or neutral species codeposited onto a surface. The newly developed instrument provides access to high-purity ion fragments as building blocks for the preparation of unique ionic layers.


  • Design and Performance of a Dual-Polarity Instrument for Ion Soft Landing

    by Pei Su, Hang Hu, Jonas Warneke, Mikhail E. Belov, Gordon A. Anderson, Julia Laskin

    A new apparatus for ion soft landing research was developed and is reported in this contribution. The instrument includes a dual polarity high flux electrospray ionization (ESI) interface, a tandem electrodynamic ion funnel system, a collisional flatapole, a quadrupole mass filter and a focusing lens. The instrument enables production of ionic layers by soft landing of mass-selected ions onto surfaces with balanced or imbalanced charge conditions using either layer-by-layer (LBL) or fast polarity switching modes. We present the first evidence of using weakly coordinating stable anions to protect the ionizing protons of soft-landed cations on the surface. The observed proton retention is particularly efficient when fast polarity switching of anions and cations is employed to deposit small quantities of ions in short deposition segments. Furthermore, we observe more efficient charge retention and better ionic complexation in a charge-balanced layer prepared by fast polarity switching deposition. These findings open up new opportunities for the fabrication of novel ionic assemblies using well-defined gaseous ions as building blocks.


  • Ultraviolet Photodissociation of ESI- and MALDI-Generated Protein Ions on a Q-Exactive Mass Spectrometer

    by Marialaura Dilillo, Erik L. de Graaf, Avinash Yadav, Mikhail E. Belov, Liam A. McDonnell

    The identification of molecular ions produced by MALDI or ESI strongly relies on their fragmentation to structurally informative fragments. The widely diffused fragmentation techniques for ESI multiply charged ions, are either incompatible (ECD and ETD) or show lower efficiency (CID, HCD), with the predominantly singly charged peptide and protein ions formed by MALDI. In source decay (ISD) has been successfully adopted to sequence MALDI generated ions, but it further increases spectral complexity and it is not compatible with Mass Spectrometry Imaging. Excellent UVPD performances, in terms of number of fragment ions and sequence coverage has been demonstrated for electrospray ionization for multiple proteomics applications. UVPD showed a much lower charge state dependence and so protein ions produced by MALDI may exhibit equal propensity to fragment. Here we report UVPD implementation on an Orbitrap Q-Exactive plus equipped with a ESI/EP-MALDI. UVPD of MALDI generated ions was benchmarked against MALDI-ISD, MALDI-HCD and ESI-UVPD. MALDI-UVPD outperformed MALDI-HCD and ISD efficiently sequencing small proteins ions. Moreover, the singly charged nature of MALDI-UVPD avoids the bioinformatics challenges associated with highly congested ESI-UVPD mass spectra. Our results demonstrate the ability of UVPD to further improve tandem mass spectrometry capabilities for MALDI generated protein ions. Data are available via ProteomeXchange with identifier PXD011526.


  • Design and Performance of a Novel Interface for Combined Matrix-Assisted Laser Desorption Ionization at Elevated Pressure and Electrospray Ionization with Orbitrap Mass Spectrometry

    by Mikhail E. Belov, Shane R. Ellis, Marialaura Dilillo, Martin R. L. Paine, William F. Danielson, Gordon A. Anderson, Erik L. de Graaf, Gert B. Eijkel, Ron M. A. Heeren, Liam A. McDonnell

    Matrix-Assisted Laser Desorption Ionization, MALDI, has been increasingly used in a variety of biomedical applications, including tissue imaging of clinical tissue samples, and in drug discovery and development. These studies strongly depend on the performance of the analytical instrumentation and would drastically benefit from improved sensitivity, reproducibility, and mass/spatial resolution. In this work, we report on a novel combined MALDI/ESI interface, which was coupled to different Orbitrap mass spectrometers (Elite and Q Exactive Plus) and extensively characterized with peptide and protein standards, and in tissue imaging experiments. In our approach, MALDI is performed in the elevated pressure regime (5–8 Torr) at a spatial resolution of 15–30 μm, while ESI-generated ions are injected orthogonally to the interface axis. We have found that introduction of the MALDI-generated ions into an electrodynamic dual-funnel interface results in increased sensitivity characterized by a limit of detection of ∼400 zmol, while providing a mass measurement accuracy of 1 ppm and a mass resolving power of 120 000 in analysis of protein digests. In tissue imaging experiments, the MALDI/ESI interface has been employed in experiments with rat brain sections and was shown to be capable of visualizing and spatially characterizing very low abundance analytes separated only by 20 mDa. Comparison of imaging data has revealed excellent agreement between the MALDI and histological images.


  • An efficient data format for mass spectrometry-based proteomics

    by Anuj R. Shah, Jennifer Davidson, Matthew E. Monroe, Anoop M. Mayampurath, William F. Danielson, Yan Shi, Aaron C. Robinson, Brian H. Clowers, Mikhail E. Belov, Gordon A. Anderson, et al.

    The diverse range of mass spectrometry (MS) instrumentation along with corresponding proprietary and nonproprietary data formats has generated a proteomics community driven call for a standardized format to facilitate management, processing, storing, visualization, and exchange of both experimental and processed data. To date, significant efforts have been extended towards standardizing XML-based formats for mass spectrometry data representation, despite the recognized inefficiencies associated with storing large numeric datasets in XML. The proteomics community has periodically entertained alternate strategies for data exchange, e.g., using a common application programming interface or a database-derived format. However, these efforts have yet to gain significant attention, mostly because they have not demonstrated significant performance benefits over existing standards, but also due to issues such as extensibility to multidimensional separation systems, robustness of operation, and incomplete or mismatched vocabulary. Here, we describe a format based on standard database principles that offers multiple benefits over existing formats in terms of storage size, ease of processing, data retrieval times, and extensibility to accommodate multidimensional separation systems.


  • A new technique for unbiased external ion accumulation in a quadrupole two‐dimensional ion trap for electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry

    by Mikhail E. Belov, Evgenii N. Nikolaev, Kim Alving, Richard D. Smith

    External ion accumulation in a two‐dimensional (2D) multipole trap has been shown to increase the sensitivity, dynamic range and duty cycle of a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer. However, it is important that trapped ions be detected without significant bias at longer accumulation times in the external 2D multipole trap. With increasing ion accumulation time pronounced m/z discrimination was observed when trapping ions in an accumulation quadrupole. In this work we show that superimposing lower rf‐amplitude dipolar excitation over the main rf‐field in the accumulation quadrupole results in disruption of the m/z discrimination and can potentially be used to achieve unbiased external ion accumulation with FTICR. Copyright © 2001 John Wiley & Sons, Ltd.