HZHao Zhang

Hao Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hao Zhang has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Leveraging Digital Health Technologies to Assess Older Adults’ Frailty and Nutritional Status: Two Cross-Sectional Studies

    by Nunzio Camerlingo, Madisen Wicker, Dimitrios J Psaltos, Nina Shaafi-Kabiri, Hao Zhang, Andrew Messere, Isabelle Messina, Zachary Hayden, Meredith Kelly, Gauri Kamat, et al.

    Background: With the rising prevalence of aging worldwide, there is a necessity for reliable and frequent assessments of older individuals’ health status to manage and potentially prevent age-related complications. Digital health technologies (DHTs), such as wearable devices, provide an opportunity to gather objective, continuous, and unobtrusive measurements, enabling effective health management in everyday life. Objective: We aimed to evaluate the relationship between digital endpoints and frailty, nutritional status, and patient-reported outcomes (PROs) in older individuals, as well as quantified their compliance and comfort with DHTs. Methods: In two cross-sectional studies, namely the Geriatric Anorexia Studies 1 and 2, including three in-clinic visits and 2-3 weeks of at-home monitoring, 94 participants (mean age 72.98 years, SD 6.28 years) were stratified based on their frailty status (n=39, 41%, nonfrail; n=45, 48%, prefrail; and n=10, 11%, frail) and nutritional status (n=70, 74%, with normal nutrition and n=24, 26%, at risk for malnutrition), as assessed in a clinical setting using the Fried Frailty Score and the Simplified Nutritional Appetite Questionnaire, respectively. We remotely monitored older adults using different DHTs. At home, participants were monitored with a wrist accelerometer for physical activity, continuous glucose monitoring (CGM) for glucose concentration, a digital body scale for weight and body composition, and a digital nutritional scale for meal tracking. Compliance with devices was assessed via wear time and correct at-home usage, while comfort was evaluated using questionnaires. The association between digital endpoints and frailty/nutritional status was investigated via linear regression, followed by ANOVA, and the relationship between digital endpoints collected at home and PROs was evaluated via Spearman’s ρ. Weight and body composition were also assessed during in-clinic visits with a research-grade scale, used to validate the at-home digital body scale measurements, via the intraclass correlation coefficient, Pearson’s R, and Bland-Altman plots with mean bias. Results: Physical activity digital endpoints collected at home were significantly different across frailty and nutritional groups and significantly correlated with self-reported appetite, fatigue, and physical function (eg, for mean daily activity in the maximum 60 minutes of activity, ρ=0.28, –0.23, and 0.47, respectively). More than 80% of participants reported that all devices were mostly to very acceptable to wear/use: 95% (88/93) for the body scale, 86% (43/50) for CGM, 80% (40/50) for the nutrition scale, and 91% (84/93) for the wrist accelerometer. Compliance ranged from 60% of monitoring days for the digital nutrition scale to 90% for the wrist accelerometer. Conclusions: Physical activity digital endpoints show clear prognostic significance for frailty and malnutrition in older individuals and reflect self-reported measures. DHTs can be reliably deployed at home for older individuals to measure their physical activity, weight and body composition, glucose concentration, and meal intakes, thus enabling patient-centric, data-centric clinical trials. Trial Registration: ClinicalTrials.gov NCT04858932; https://clinicaltrials.gov/study/NCT04858932; ClinicalTrials.gov NCT05211973; https://clinicaltrials.gov/study/NCT05211973

  • Open Access

    Leveraging Digital Health Technologies to Assess Older Adults’ Frailty and Nutritional Status: Two Cross-Sectional Studies (Preprint)

    by Nunzio Camerlingo, Madisen Wicker, Dimitrios J Psaltos, Nina Shaafi-Kabiri, Hao Zhang, Andrew Messere, Isabelle Messina, Zachary Hayden, Meredith Kelly, Gauri Kamat, et al.

    BACKGROUND With the rising prevalence of aging worldwide, there is a necessity for reliable and frequent assessments of older individuals’ health status to manage and potentially prevent age-related complications. Digital health technologies (DHTs), such as wearable devices, provide an opportunity to gather objective, continuous, and unobtrusive measurements, enabling effective health management in everyday life. OBJECTIVE We aimed to evaluate the relationship between digital endpoints and frailty, nutritional status, and patient-reported outcomes (PROs) in older individuals, as well as quantified their compliance and comfort with DHTs. METHODS In two cross-sectional studies, namely the Geriatric Anorexia Studies 1 and 2, including three in-clinic visits and 2-3 weeks of at-home monitoring, 94 participants (mean age 72.98 years, SD 6.28 years) were stratified based on their frailty status (n=39, 41%, nonfrail; n=45, 48%, prefrail; and n=10, 11%, frail) and nutritional status (n=70, 74%, with normal nutrition and n=24, 26%, at risk for malnutrition), as assessed in a clinical setting using the Fried Frailty Score and the Simplified Nutritional Appetite Questionnaire, respectively. We remotely monitored older adults using different DHTs. At home, participants were monitored with a wrist accelerometer for physical activity, continuous glucose monitoring (CGM) for glucose concentration, a digital body scale for weight and body composition, and a digital nutritional scale for meal tracking. Compliance with devices was assessed via wear time and correct at-home usage, while comfort was evaluated using questionnaires. The association between digital endpoints and frailty/nutritional status was investigated via linear regression, followed by ANOVA, and the relationship between digital endpoints collected at home and PROs was evaluated via Spearman’s ρ. Weight and body composition were also assessed during in-clinic visits with a research-grade scale, used to validate the at-home digital body scale measurements, via the intraclass correlation coefficient, Pearson’s R, and Bland-Altman plots with mean bias. RESULTS Physical activity digital endpoints collected at home were significantly different across frailty and nutritional groups and significantly correlated with self-reported appetite, fatigue, and physical function (eg, for mean daily activity in the maximum 60 minutes of activity, ρ=0.28, –0.23, and 0.47, respectively). More than 80% of participants reported that all devices were mostly to very acceptable to wear/use: 95% (88/93) for the body scale, 86% (43/50) for CGM, 80% (40/50) for the nutrition scale, and 91% (84/93) for the wrist accelerometer. Compliance ranged from 60% of monitoring days for the digital nutrition scale to 90% for the wrist accelerometer. CONCLUSIONS Physical activity digital endpoints show clear prognostic significance for frailty and malnutrition in older individuals and reflect self-reported measures. DHTs can be reliably deployed at home for older individuals to measure their physical activity, weight and body composition, glucose concentration, and meal intakes, thus enabling patient-centric, data-centric clinical trials. CLINICALTRIAL ClinicalTrials.gov NCT04858932; https://clinicaltrials.gov/study/NCT04858932; ClinicalTrials.gov NCT05211973; https://clinicaltrials.gov/study/NCT05211973

  • Open Access

    Assessment of Sit-to-Stand Transfers during Daily Life Using an Accelerometer on the Lower Back

    by Lukas Adamowicz, F. Isik Karahanoglu, Christopher Cicalo, Hao Zhang, Charmaine Demanuele, Mar Santamaria, Xuemei Cai, Shyamal Patel

    The ability to perform sit-to-stand (STS) transfers has a significant impact on the functional mobility of an individual. Wearable technology has the potential to enable the objective, long-term monitoring of STS transfers during daily life. However, despite several recent efforts, most algorithms for detecting STS transfers rely on multiple sensing modalities or device locations and have predominantly been used for assessment during the performance of prescribed tasks in a lab setting. A novel wavelet-based algorithm for detecting STS transfers from data recorded using an accelerometer on the lower back is presented herein. The proposed algorithm is independent of device orientation and was validated on data captured in the lab from younger and older healthy adults as well as in people with Parkinson’s disease (PwPD). The algorithm was then used for processing data captured in free-living conditions to assess the ability of multiple features extracted from STS transfers to detect age-related group differences and assess the impact of monitoring duration on the reliability of measurements. The results show that performance of the proposed algorithm was comparable or significantly better than that of a commercially available system (precision: 0.990 vs. 0.868 in healthy adults) and a previously published algorithm (precision: 0.988 vs. 0.643 in persons with Parkinson’s disease). Moreover, features extracted from STS transfers at home were able to detect age-related group differences at a higher level of significance compared to data captured in the lab during the performance of prescribed tasks. Finally, simulation results showed that a monitoring duration of 3 days was sufficient to achieve good reliability for measurement of STS features. These results point towards the feasibility of using a single accelerometer on the lower back for detection and assessment of STS transfers during daily life. Future work in different patient populations is needed to evaluate the performance of the proposed algorithm, as well as assess the sensitivity and reliability of the STS features.


  • Open Access

    The Impact of Reducing the Number of Wearable Devices on Measuring Gait in Parkinson Disease: Noninterventional Exploratory Study

    by Matthew Czech, Charmaine Demanuele, Michael Kelley Erb, Vesper Ramos, Hao Zhang, Bryan Ho, Shyamal Patel

    Background: Measuring free-living gait using wearable devices may offer higher granularity and temporal resolution than the current clinical assessments for patients with Parkinson disease (PD). However, increasing the number of devices worn on the body adds to the patient burden and impacts the compliance. Objective: This study aimed to investigate the impact of reducing the number of wearable devices on the ability to assess gait impairments in patients with PD. Methods: A total of 35 volunteers with PD and 60 healthy volunteers performed a gait task during 2 clinic visits. Participants with PD were assessed in the On and Off medication state using the Movement Disorder Society version of the Unified Parkinson Disease Rating Scale (MDS-UPDRS). Gait features derived from a single lumbar-mounted accelerometer were compared with those derived using 3 and 6 wearable devices for both participants with PD and healthy participants. Results: A comparable performance was observed for predicting the MDS-UPDRS gait score using longitudinal mixed-effects model fit with gait features derived from a single (root mean square error [RMSE]=0.64; R2=0.53), 3 (RMSE=0.64; R2=0.54), and 6 devices (RMSE=0.54; R2=0.65). In addition, MDS-UPDRS gait scores predicted using all 3 models differed significantly between On and Off motor states (single device, P=.004; 3 devices, P=.004; 6 devices, P=.045). Conclusions: We observed a marginal benefit in using multiple devices for assessing gait impairments in patients with PD when compared with gait features derived using a single lumbar-mounted accelerometer. The wearability burden associated with the use of multiple devices may offset gains in accuracy for monitoring gait under free-living conditions.


  • Open Access

    The Impact of Reducing the Number of Wearable Devices on Measuring Gait in Parkinson Disease: Noninterventional Exploratory Study (Preprint)

    by Matthew Czech, Charmaine Demanuele, Michael Kelley Erb, Vesper Ramos, Hao Zhang, Bryan Ho, Shyamal Patel

    BACKGROUND Measuring free-living gait using wearable devices may offer higher granularity and temporal resolution than the current clinical assessments for patients with Parkinson disease (PD). However, increasing the number of devices worn on the body adds to the patient burden and impacts the compliance. OBJECTIVE This study aimed to investigate the impact of reducing the number of wearable devices on the ability to assess gait impairments in patients with PD. METHODS A total of 35 volunteers with PD and 60 healthy volunteers performed a gait task during 2 clinic visits. Participants with PD were assessed in the On and Off medication state using the Movement Disorder Society version of the Unified Parkinson Disease Rating Scale (MDS-UPDRS). Gait features derived from a single lumbar-mounted accelerometer were compared with those derived using 3 and 6 wearable devices for both participants with PD and healthy participants. RESULTS A comparable performance was observed for predicting the MDS-UPDRS gait score using longitudinal mixed-effects model fit with gait features derived from a single (root mean square error [RMSE]=0.64; R2=0.53), 3 (RMSE=0.64; R2=0.54), and 6 devices (RMSE=0.54; R2=0.65). In addition, MDS-UPDRS gait scores predicted using all 3 models differed significantly between On and Off motor states (single device, P=.004; 3 devices, P=.004; 6 devices, P=.045). CONCLUSIONS We observed a marginal benefit in using multiple devices for assessing gait impairments in patients with PD when compared with gait features derived using a single lumbar-mounted accelerometer. The wearability burden associated with the use of multiple devices may offset gains in accuracy for monitoring gait under free-living conditions. CLINICALTRIAL


  • A distinctive subpopulation of medial septal slow-firing neurons promote hippocampal activation and theta oscillations

    by Hao Zhang, Shih-Chieh Lin, Miguel A. L. Nicolelis

    The medial septum-vertical limb of the diagonal band of Broca (MSvDB) is important for normal hippocampal functions and theta oscillations. Although many previous studies have focused on understanding how MSVDB neurons fire rhythmic bursts to pace hippocampal theta oscillations, a significant portion of MSVDB neurons are slow-firing and thus do not pace theta oscillations. The function of these MSVDB neurons, especially their role in modulating hippocampal activity, remains unknown. We recorded MSVDB neuronal ensembles in behaving rats, and identified a distinct physiologically homogeneous subpopulation of slow-firing neurons (overall firing 1) much higher firing rate during rapid eye movement sleep than during slow-wave (SW) sleep; 2) temporary activation associated with transient arousals during SW sleep; 3) brief responses (latency 15∼30 ms) to auditory stimuli. Analysis of the fine temporal relationship of their spiking and theta oscillations showed that unlike the theta-pacing neurons, the firing of these “pro-arousal” neurons follows theta oscillations. However, their activity precedes short-term increases in hippocampal oscillation power in the theta and gamma range lasting for a few seconds. Together, these results suggest that these pro-arousal slow-firing MSvDB neurons may function collectively to promote hippocampal activation.


  • Relation of addiction genes to hypothalamic gene changes subserving genesis and gratification of a classic instinct, sodium appetite

    by Wolfgang B. Liedtke, Michael J. McKinley, Lesley L. Walker, Hao Zhang, Andreas R. Pfenning, John Drago, Sarah J. Hochendoner, Donald L. Hilton, Andrew J. Lawrence, Derek A. Denton

    Sodium appetite is an instinct that involves avid specific intention. It is elicited by sodium deficiency, stress-evoked adrenocorticotropic hormone (ACTH), and reproduction. Genome-wide microarrays in sodium-deficient mice or after ACTH infusion showed up-regulation of hypothalamic genes, including dopamine- and cAMP-regulated neuronal phosphoprotein 32 kDa (DARPP-32), dopamine receptors-1 and -2, α-2C- adrenoceptor, and striatally enriched protein tyrosine phosphatase (STEP). Both DARPP-32 and neural plasticity regulator activity-regulated cytoskeleton associated protein (ARC) were up-regulated in lateral hypothalamic orexinergic neurons by sodium deficiency. Administration of dopamine D1 (SCH23390) and D2 receptor (raclopride) antagonists reduced gratification of sodium appetite triggered by sodium deficiency. SCH23390 was specific, having no effect on osmotic-induced water drinking, whereas raclopride also reduced water intake. D1 receptor KO mice had normal sodium appetite, indicating compensatory regulation. Appetite was insensitive to SCH23390, confirming the absence of off-target effects. Bilateral microinjection of SCH23390 (100 nM in 200 nL) into rats’ lateral hypothalamus greatly reduced sodium appetite. Gene set enrichment analysis in hypothalami of mice with sodium appetite showed significant enrichment of gene sets previously linked to addiction (opiates and cocaine). This finding of concerted gene regulation was attenuated on gratification with perplexingly rapid kinetics of only 10 min, anteceding significant absorption of salt from the gut. Salt appetite and hedonic liking of salt taste have evolved over >100 million y (e.g., being present in Metatheria). Drugs causing pleasure and addiction are comparatively recent and likely reflect usurping of evolutionary ancient systems with high survival value by the gratification of contemporary hedonic indulgences. Our findings outline a molecular logic for instinctive behavior encoded by the brain with possible important translational–medical implications.


  • Open Access

    Spatiotemporal Coupling between Hippocampal Acetylcholine Release and Theta OscillationsIn Vivo

    by Hao Zhang, Shih-Chieh Lin, Miguel A. L. Nicolelis

    Both acetylcholine (ACh) and theta oscillations are important for learning and memory, but the dynamic interaction between these two processes remains unclear. Recent advances in amperometry techniques have revealed phasic ACh releasesin vivo. However, it is unknown whether phasic ACh release co-occurs with theta oscillations. We investigated this issue in the CA1 region of urethane-anesthetized male rats using amperometric and electrophysiological recordings. We found that ACh release was highly correlated with the appearance of both spontaneous and induced theta oscillations. Moreover, the maximal ACh release was observed around or slightly above the pyramidal layer. Interestingly, such release lagged behind theta initiation by 25–60 s. The slow ACh release profile was matched by the slow firing rate increase of a subset of medial–septal low-firing-rate neurons. Together, these results establish, for the first time, thein vivocoupling between phasic ACh release and theta oscillations on spatiotemporal scales much finer than previously known. These findings also suggest that phasic ACh is not required for theta initiation and may instead operate synergistically with theta oscillations to promote neural plasticity in the service of learning and memory.


  • Open Access

    Novel experience induces persistent sleep-dependent plasticity in the cortex but not in the hippocampus

    by Sidarta Ribeiro, Xinwu Shi, Matthew Engelhard, Yi Zhou, Hao Zhang, Damien Gervasoni, Shi-Chieh Lin, Kazuhiro Wada, Nelson A M Lemos, Miguel A L Nicolelis

    Episodic and spatial memories engage the hippocampus during acquisition but migrate to the cerebral cortex over time. We have recently proposed that the interplay between slow-wave (SWS) and rapid eye movement (REM) sleep propagates recent synaptic changes from the hippocampus to the cortex. To test this theory, we jointly assessed extracellular neuronal activity, local field potentials (LFP), and expression levels of plasticity-related immediate-early genes (IEG) arc and zif-268 in rats exposed to novel spatio-tactile experience. Post-experience firing rate increases were strongest in SWS and lasted much longer in the cortex (hours) than in the hippocampus (minutes). During REM sleep, firing rates showed strong temporal dependence across brain areas: cortical activation during experience predicted hippocampal activity in the first post-experience hour, while hippocampal activation during experience predicted cortical activity in the third post-experience hour. Four hours after experience, IEG expression was specifically upregulated during REM sleep in the cortex, but not in the hippocampus. Arc gene expression in the cortex was proportional to LFP amplitude in the spindle-range (10-14 Hz) but not to firing rates, as expected from signals more related to dendritic input than to somatic output. The results indicate that hippocampo-cortical activation during waking is followed by multiple waves of cortical plasticity as full sleep cycles recur. The absence of equivalent changes in the hippocampus may explain its mnemonic disengagement over time.