Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Eyad A. Feilat has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimal Hybrid Energy System Sizing for Green Hydrogen Production: Scenario-Based Techno-Economic Approach

    by Ahmad Abuyahya, Eyad A. Feilat, Anas Abuzayed

    This study presents a comprehensive techno-economic assessment to optimize a hybrid renewable energy system for green hydrogen production in Jordan. Using the Hybrid Optimization Model for Electric Renewables (HOMERs) and System Advisor Model (SAM) software, this study evaluates multiple cost projections for 2030 technology costs. Key parameters such as capital cost, efficiency, and lifetime are varied extensively. Highlighted results show a wide range in the Levelized Cost of Hydrogen (LCOH), reaching 1.59 to 3.49 USD/kg, and the Levelized Cost of Energy (LCOE) from 0.0072 to 0.0301 USD/kWh. Furthermore, Net Present Value (NPV) spans from USD 424 to 927 million, depending on the scenario and sensitivity case. Technically, the system’s optimized capacities vary significantly. PV ranges from 203 to 457 MW, wind capacities range from 0 to 220 MW, and electrolyzers range from 192 to 346 MW, demonstrating the flexibility required to meet different cost and performance assumptions. The study’s broad relevance extends to developing countries with grid constraints, where off-grid green hydrogen production is feasible. Its framework can be adapted globally, offering valuable insights.


  • Maximum Power Point Tracking Technique Using Combined Incremental Conductance and Owl Search Algorithm

    by Sara N. Altamimi, Eyad A. Feilat, Dia Abu Al Nadi

    This paper aims to develop a new maximum power point tracking technique to obtain the maximum possible power from photovoltaic modules. The technique is based on combining the conventional incremental conductance technique along with the Owl search optimization algorithm. The new proposed technique also aims to simultaneously increase the tracking speed and mitigate the inherent drawbacks of the conventional incremental conductance technique, in particular the maximum power point settling time which is highly affected by the operating duty cycle. The performance of the proposed technique is examined through several Matlab/Simulink simulation case studies under various irradiance and temperature conditions. Basically, three case studies are investigated including the response of the system under standard temperature conditions, step-change in environment temperature and step-changes in irradiance. The simulation results reveal that the proposed technique provides faster tracking time, less oscillation, and higher efficiency as compared to the response of the conventional incremental conductance technique.


  • New Distance Protection Scheme for PV Microgrids

    by Fadi M. AlAlamat, Eyad A. Feilat, Mohammed A. Haj-Ahmed

    The fault current in a PV-integrated microgrid (PV-MG) has a relatively low value and an unpredictable phase angle, making current-measurement based fault detection techniques highly unreliable. This paper investigates the ability of conventional distance protection to detect and allocate balanced (LLL-G) faults on MG feeders emanating a PV inverter (PVI). Different PVI grid-support settings are investigated. PSCAD simulations show that conventional distance protection can reliably detect solid LLL-G faults on feeders emanating from PVIs. In the case of non-solid faults, however, conventional distance relays fail due to the unpredictable phase angle between the PVI fault current and the grid fault current infeed. Subsequently, the study proposes a novel high-frequency current injection (HFCI) distance protection scheme capable of accurately detecting faults regardless of fault resistance. PSCAD simulations prove the speed and reliability of the proposed HFCI distance scheme in both grid-connected and islanded modes of operation for both solid and non-solid faults.


  • Total Leakage Current Decomposition of Surge Arresters Using Discrete Fourier Transform

    by Eyad A. Feilat, Dalia Abu-Eideh, Ibrahim A. Metwally

    Overvoltage surge arresters (SAs) are subjected to degradation due to continuous operation, moisture ingress, and increasing heating conditions. Catastrophic failures of SAs can be avoided by assessing their performance using either online monitoring or offline testing techniques. This paper presents an efficient offline experimental technique for harmonic components extraction of leakage currents of SAs by decomposing the total leakage current (TLC) into its capacitive and resistive components. The technique aims to extract the third harmonic resistive current, which is considered an important indicator for assessing the degradation level of SAs, using discrete Fourier transform (DFT). In this work, diagnosis of three 33 kV, 10 kA SAs, namely polymer zinc oxide (ZnO), silicon rubber ZnO, and porcelain silicon carbide (SiC) distribution class SAs is presented. The experimental results show the capability of the proposed technique for diagnosing both ZnO and SiC arresters.


  • Maximum Power Point Tracking Technique Using Combined Perturb & Observe and Owl Search Algorithms

    by Alaa F. Farhan, Eyad A. Feilat, Ahmed S. Al-Salaymeh

    Maximum power point tracking (MPPT) techniques are employed to improve the efficiency of photovoltaic (PV) systems by maximizing the amount of power generated from the PV modules. The tracking technique becomes more challenging under non-steady irradiance and temperature conditions. Perturb and Observe (P&O) algorithm is one of the widely used tracking techniques. However, P&O tracking algorithm suffers from some drawbacks such as sustained oscillation around the MPP. This paper presents a new technique to track the MPP under steady and non-steady irradiation and temperature conditions. The proposed technique combines the P&O method with the Owl Search Algorithm (OSA). The proposed MPPT technique is simulated using Matlab/Simulink environment. Three case studies including start-up and step variation of irradiation and temperature are investigated. The proposed technique is compared with P&O technique. The simulation results show that the developed technique presents fast response and efficient maximum power tracking.


  • Estimation of Synchronizing and Damping Torque Coefficients Using Deep Learning

    by Ahmad Hammoudeh, Mohammad I. Al Saaideh, Eyad A. Feilat, Hamza Mubarak

    This paper presents a deep learning based approach for small-signal stability of a single machine connected to infinite bus. The proposed approach is based on an optimal estimation of the synchronizing and damping torque coefficients of the synchronous generator by optimal measurement of the operating conditions including the voltage, real power and reactive power. The proposed approach in this paper is to train deep neural networks to estimate the synchronizing and damping torque coefficients for all examples that the power system may encounter. Hence, a large dataset of more than 310,000 examples is created to cover the full range of the possible operation conditions. The performance of deep neural networks based approach is compared with that of other neural networks reported in the literature. Simulations results show that the proposed approach is robust and training the neural network over a wide range of operating conditions yield fast, yet accurate estimation of the torque coefficients.


  • Lightning Impulse Parameter Estimation Using Nonlinear Least Squares Algorithm

    by Mohammad I. Al Saaideh, Eyad A. Feilat, Dia I. Abu-Al-Nadi, Amer S. Al-Hinai

    This paper presents a new technique based on nonlinear least square (NLSQ) algorithm for estimating the mean curve and parameters of the standard lightning impulse (LI) waveform as required by IEC 60 and IEEE Std. 4. The proposed NLSQ technique is applied to analytical LI waveforms to estimate the mean curve of the impulse using a bi-exponential model after removing high frequency components from the simulated (measured) impulse. The effectiveness of the proposed technique is assessed by conducting several cases of LI impulse waveforms with front and tail oscillations and LI waveform with overshoot. The results of the NLSQ technique are compared with those obtained by the particle swarm optimization (PSO) algorithm. The simulation results show that the proposed NLSQ technique is robust and effective in estimating the peak value, front and tail times of the impulse waveform accurately.


  • Open Access

    Lifetime Assessment of Electrical Insulation

    by Eyad A. Feilat

    In this chapter, a review of the Weibull probability distribution, probability ranking, and the Weibull graphical estimation technique is presented. A review of single-stress and multiple-stress life models of electrical insulation is also introduced. The chapter also describes the graphical, linear and multiple linear regression techniques used in estimating the parameters of the aging models. The application of maximum likelihood estimation technique for estimating the parameters of combined life models of electrical insulation is illustrated.


  • Comprehensive Protection Schemes for Different Types of Wind Generators

    by Mohammed A. Haj-Ahmed, Eyad A. Feilat, Hussam J. Khasawneh, Ahmad Fares Abdelhadi, Ala'A Awwad

    The fault characteristics for different types of wind generators are studied in this paper. Three types of wind generators are simulated within a microgrid that has the ability to connect and disconnect to a main grid. Types 1, 3, and 4 wind generators are simulated in both connected and islanded modes using MATLAB/SIMULINK software. The attributes of the current and voltage waveforms for each type at the time of the fault are detected. The simulation results show that each type of the wind generators contribute to the fault current in a way differs from the other type due to its configuration. The attributes of the fault characteristics reveals that careful design of the protection schemes that protect the system should be considered and special requirements on fault ride through capabilities are needed. Adequate protection schemes that suit the three types of the wind generators are proposed for islanded and grid-connected modes.