DCDouglas W. Cromey

Douglas W. Cromey

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Douglas W. Cromey has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Comparison of Iron Oxide Particles and Silica Particles for Tracking Organ Recellularization

    by Joseph E. Kobes, George I. Georgiev, Anthony V. Louis, Isen A. Calderon, Eriko S. Yoshimaru, Louie M. Klemm, Douglas W. Cromey, Zain Khalpey, Mark D. Pagel

    Reseeding of decellularized organ scaffolds with a patient’s own cells has promise for eliminating graft versus host disease. This study investigated whether ultrasound imaging or magnetic resonance imaging (MRI) can track the reseeding of murine liver scaffolds with silica-labeled or iron-labeled liver hepatocytes. Mesoporous silica particles were created using the Stöber method, loaded with Alexa Flour 647 fluorophore, and conjugated with protamine sulfate, glutamine, and glycine. Fluorescent iron oxide particles were obtained from a commercial source. Liver cells from donor mice were loaded with the silica particles or iron oxide particles. Donor livers were decellularized and reperfused with silica-labeled or iron-labeled cells. The reseeded livers were longitudinally analyzed with ultrasound imaging and MRI. Liver biopsies were imaged with confocal microscopy and scanning electron microscopy. Ultrasound imaging had a detection limit of 0.28 mg/mL, while MRI had a lower detection limit of 0.08 mg/mL based on particle weight. The silica-loaded cells proliferated at a slower rate compared to iron-loaded cells. Ultrasound imaging, MRI, and confocal microscopy underestimated cell numbers relative to scanning electron microscopy. Ultrasound imaging had the greatest underestimation due to coarse resolution compared to the other imaging modalities. Despite this underestimation, both ultrasound imaging and MRI successfully tracked the longitudinal recellularization of liver scaffolds.


  • Open Access

    Digital Images Are Data: And Should Be Treated as Such

    by Douglas W. Cromey

    The scientific community has become very concerned about inappropriate image manipulation. In journals that check figures after acceptance, 20–25% of the papers contained at least one figure that did not comply with the journal’s instructions to authors. The scientific press continues to report a small, but steady stream of cases of fraudulent image manipulation. Inappropriate image manipulation taints the scientific record, damages trust within science, and degrades science’s reputation with the general public. Scientists can learn from historians and photojournalists, who have provided a number of examples of attempts to alter or misrepresent the historical record. Scientists must remember that digital images are numerically sampled data that represent the state of a specific sample when examined with a specific instrument. These data should be carefully managed. Changes made to the original data need to be tracked like the protocols used for other experimental procedures. To avoid pitfalls, unexpected artifacts, and unintentional misrepresentation of the image data, a number of image processing guidelines are offered.


  • Top Cited Papers

    Avoiding Twisted Pixels: Ethical Guidelines for the Appropriate Use and Manipulation of Scientific Digital Images

    by Douglas W. Cromey

    Digital imaging has provided scientists with new opportunities to acquire and manipulate data using techniques that were difficult or impossible to employ in the past. Because digital images are easier to manipulate than film images, new problems have emerged. One growing concern in the scientific community is that digital images are not being handled with sufficient care. The problem is twofold: (1) the very small, yet troubling, number of intentional falsifications that have been identified, and (2) the more common unintentional, inappropriate manipulation of images for publication. Journals and professional societies have begun to address the issue with specific digital imaging guidelines. Unfortunately, the guidelines provided often do not come with instructions to explain their importance. Thus they deal with what should or should not be done, but not the associated ‘why’ that is required for understanding the rules. This article proposes 12 guidelines for scientific digital image manipulation and discusses the technical reasons behind these guidelines. These guidelines can be incorporated into lab meetings and graduate student training in order to provoke discussion and begin to bring an end to the culture of “data beautification”.


  • The Darkroom is Closed. Introducing Digital Image Ethics to a New Generation.

    by D Cromey

    Extended abstract of a paper presented at Microscopy and Microanalysis 2009 in Richmond, Virginia, USA, July 26 – July 30, 2009

  • Arsenite and monomethylarsonous acid generate oxidative stress response in human bladder cell culture

    by K.E. Eblin, M.E. Bowen, D.W. Cromey, T.G. Bredfeldt, E.A. Mash, S.S. Lau, A.J. Gandolfi


  • Morphological and functional alterations in human proximal tubular cell line induced by low level inorganic arsenic: evidence for targeting of mitochondria and initiated apoptosis

    by Marjorie A. Peraza, Douglas W. Cromey, Barb Carolus, Dean E. Carter, A. Jay Gandolfi

    The kidney is a known target organ for arsenic and is critical for both arsenic biotransformation and elimination. Previous studies have demonstrated that at high doses (ppm) inorganic arsenic is toxic to mitochondria primarily by affecting cellular respiration. However, the effect of inorganic arsenic on mitochondria after low level exposures is not known, particularly in the kidney. Thus the functional and morphological effects of low level inorganic arsenic were investigated in a human proximal tubular cell line, HK‐2. Mitochondrial function was assessed at subcytotoxic concentrations of arsenite (≤ 10 µm) by examining the alteration of the mitochondrial membrane potential using MitoTracker Red, a mitochondrion selective dye. In a subset of cells, subcytotoxic arsenite led to mitochondrial membrane depolarization, which could subsequently lead to permeability transition and apoptosis. Subcytotoxic arsenite also induced translocation of phosphatidylserine, indicative of early‐stage apoptosis. To confirm whether subcytotoxic arsenite induces cellular and/or mitochondrial morphological alterations consistent with initiated apoptosis, HK‐2 cells were evaluated with transmission electron microscopy. Classic morphology of apoptosis was not observed with subcytotoxic arsenite exposures; however, evidence of necrotic changes in the cytoplasmic structure and mitochondrial morphology were apparent. Therefore, based on depolarization of mitochondria and the externalization of phosphatidylserine, HK‐2 cells appear to initiate apoptosis following subcytotoxic arsenite insult, but morphological changes indicate that HK‐2 cells fail to complete apoptosis and ultimately undergo necrosis. Therefore, subcytotoxic arsenite can be sufficiently toxic to mitochondria that they lose their ability to keep the cell on course for apoptotic cell death. Copyright © 2006 John Wiley & Sons, Ltd.


  • Programmed cell death of the normal human neutrophil: An in vitro model of senescence

    by Claire M. Payne, Lewis Glasser, Marc E. Tischler, Deborah Wyckoff, Douglas Cromey, Roger Fiederlein, Oliver Bohnert

    The present study provides experimental data which indicate that the neutrophil is ideal for studying programmed cell death or apoptosis in vitro. Neutrophils can be obtained from human peripheral blood in large numbers with minimal experimental manipulation and are easily separated from other leukocytes, providing nearly pure cell suspensions. The neutrophil life span in vitro is sufficiently short to allow observations to be made within eight hours after experimental manipulation. Neutrophils can also be easily maintained in serum‐free, chemically defined media which can be systematically altered, thereby defining specific variables that influence the apoptotic process. Since the neutrophils do not need an exogenous trigger to undergo programmed cell death, it is also an excellent model to study senescence. It was determined from this study that neutrophils undergo apoptosis most efficiently at 37°C, a temperature requirement for physiologic cell death. Neutrophils undergo apoptosis at a slightly faster rate and maintain membrane integrity better when incubated in a tissue culture medium (e.g., RPMI 1640) compared with a balanced salt solution (e.g., HBBB). Cycloheximide, an inhibitor of protein synthesis, was shown to accelerate apoptosis in a dose‐dependent manner. The presence of Zn++ significantly decreased the rate of apoptosis, whereas the presence of Ca++ and Mg++ had no apparent effect. These studies indicate that the process of senescence, culminating in cell death, is subject to modulation by a variety of agents and experimental conditions. In addition, the ultrastructural features of neutrophils undergoing programmed cell death in vitro were compared in detail to those occurring in vivo and were found to be comparable.


  • An Image Analysis Workstation Designed for Multiple Users: Application of Quantitative Digital Imaging Techniques to Electron Microscopy

    by Claire M. Payne, Douglas W. Cromey

    The purpose of the present study is to describe the setup of an image analysis workstation designed for multiple users, and to show the application of digital imaging techniques to the analysis of electron microscopic images. The image analysis system consists of a conventional light microscope mounted on a table-top, vibration-free platform, a light box for viewing negatives, two separate video cameras, a switch box, a video monitor, a digitizing tablet, a computer, and mor-phometric software packages. The system can quantitate the amount that each of the 256 gray levels contributes to the image, perform morpho-metric analysis (eg, shape and size) on individual gray level-defined subimages, and perform statistical analysis. Each operator has access to his or her own data and program setups through the use of 21.4-Mb removable Bernoulli cartridges. This setup for multiple users prevents the cluttering of the hard drive of the computer and avoids the possibility of accidentally removing the stored data of another user. The quantitative capabilities of the digital imaging system is demonstrated using an image of a normal lymphocyte and an apoptotic cell (ie, a cell which has undergone programmed cell death), both captured on the same electron microscopic negative. A comparison of the histograms of nuclear densities determined for these two cells reveals subtleties in gray level distribution not appreciated by the naked eye.


  • A Multidisciplinary Approach to the Diagnosis of Cutaneous T-Cell Lymphomas

    by Claire M. Payne, Thomas M. Grogan, Catherine M. Spier, Charles G. Bjore, Lynne C. Richter, Douglas W. Cromey, Catherine S. Rangel

    The cutaneous T-cell lymphomas (CTCLs) comprise a spectrum of non-Hodgkin lymphomas with a predilection for the skin. This heterogeneous group of CTCLs include the prototypic CTCL mycosis fun-goides (MF) and the recently described Ki-1 + lymphomas. MF is notoriously difficult to diagnose in its early stages. The histologic appearance of early MF is indistinguishable from that of chronic dermatitis. The limitations of light microscopy in the diagnosis of the CTCLs have led to the development of other diagnostic laboratory techniques. The best approach to the diagnosis of the CTCLs is a multi-disciplinary one and should include ultrastructural morphometry, immunophenotyping, immunogeno-typing, and histologic evaluation whenever possible. It is the purpose of this overview to point out the strengths and weaknesses of each of these techniques and, together with clinical input, to provide a comprehensive and rational approach to patient care.