Jovan Trifunovic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jovan Trifunovic has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Miomir Kostic
Faculty of Electrical Engineering, University of Belgrade, Belgrade, Serbia
3 shared publications - Nedzad Hadziefendic
Faculty of Electrical Engineering, University of Belgrade, 11000 Belgrade, Serbia
3 shared publications - Doroteja Zarev
University of Belgrade: Belgrade, RS
1 shared publication - Jelena Stojković Terzić
University of Belgrade - School of Electrical Engineering: Belgrade, Central Serbia, RS
1 shared publication Katedra za elektroenergetske sisteme Univerzitet u Beogradu – Elektrotehnički fakultet
1 shared publicationKatedra za energetske pretvarače i pogone Univerzitet u Beogradu – Elektrotehnički fakultet
1 shared publication
Latest Publications
- 19 September 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (10) , 418
Influence of the backfill materials quantity used for grounding resistance reduction on the potential distribution at the ground surface during an earth fault
- 19 September 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (10) , 418
Influence of the backfill materials quantity used for grounding resistance reduction on the potential distribution at the ground surface during an earth fault
- 1 January 2025
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. XXVII (2) , 8-14
Optimal Placement and Sizing of Solar Power Plant for Voltage Stability Improvement
This paper addresses the problem of determining the optimal location and capacity of solar power plants in distribution networks to improve voltage stability. Key voltage-related indicators, such as voltage stability and power losses, were analysed on standard IEEE 69 network to identify the optimal location for connecting a solar power plant. The growing deployment of distributed energy resources highlights the importance of proper sizing and positioning of these sources, as improperly located or oversized solar power plants can lead to voltage rise, reverse power flows, and system performance degradation. The purpose of this analysis is to assess how solar power plants, which will be potentially connected to the network, affect voltage stability in distribution networks with limited hosting capacity for renewable energy sources. These issues are particularly significant in cases where the installed capacity of solar power plants awaiting connection exceeds the hosting capacity of the observed part of the distribution network, raising the question of connection prioritization.
- 1 January 2025
- Published by University Library in Kragujevac in Energija Ekonomija Ekologija
- Vol. XXVII (2) , 8-14
Optimal Placement and Sizing of Solar Power Plant for Voltage Stability Improvement
This paper addresses the problem of determining the optimal location and capacity of solar power plants in distribution networks to improve voltage stability. Key voltage-related indicators, such as voltage stability and power losses, were analysed on standard IEEE 69 network to identify the optimal location for connecting a solar power plant. The growing deployment of distributed energy resources highlights the importance of proper sizing and positioning of these sources, as improperly located or oversized solar power plants can lead to voltage rise, reverse power flows, and system performance degradation. The purpose of this analysis is to assess how solar power plants, which will be potentially connected to the network, affect voltage stability in distribution networks with limited hosting capacity for renewable energy sources. These issues are particularly significant in cases where the installed capacity of solar power plants awaiting connection exceeds the hosting capacity of the observed part of the distribution network, raising the question of connection prioritization.
- Open Access
- 1 January 2022
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Tehnika
- Vol. 77 (2) , 215-222
Improvement of the standardized procedure for verifying the quality of low-voltage electrical installations
Periodic verification of the quality of low-voltage electrical installations is very important from the point of view of safety of people in the building from electric shock and initial fire caused by failures of low-voltage electrical installations (usually poor electrical contact). The standardized procedure for verifying the quality of electrical installations by electrical measurements involves checking which can determine with certainty only whether the protection system by automatic shutdown of the power supply in case of failure is effective or not. However, this check can only detect some poor electrical contacts in the circuit that are potential causes of fire. The paper provides an overview of research results conducted within the project of the Ministry of Education, Science and Technological Development of the Republic of Serbia (project record number 36018), on the basis of which the correction of the existing procedure of periodical verification of the quality of electrical installations is proposed. The proposed correction, which was developed based on the experience gained by performing periodical verification of the quality of electrical installations in the field, as well as analysis of measurement results obtained experimentally in laboratory conditions, allows poor electrical contacts to be detected in a timely manner.
- 1 January 2022
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Tehnika
- Vol. 77 (2) , 215-222
Open AccessImprovement of the standardized procedure for verifying the quality of low-voltage electrical installations
Periodic verification of the quality of low-voltage electrical installations is very important from the point of view of safety of people in the building from electric shock and initial fire caused by failures of low-voltage electrical installations (usually poor electrical contact). The standardized procedure for verifying the quality of electrical installations by electrical measurements involves checking which can determine with certainty only whether the protection system by automatic shutdown of the power supply in case of failure is effective or not. However, this check can only detect some poor electrical contacts in the circuit that are potential causes of fire. The paper provides an overview of research results conducted within the project of the Ministry of Education, Science and Technological Development of the Republic of Serbia (project record number 36018), on the basis of which the correction of the existing procedure of periodical verification of the quality of electrical installations is proposed. The proposed correction, which was developed based on the experience gained by performing periodical verification of the quality of electrical installations in the field, as well as analysis of measurement results obtained experimentally in laboratory conditions, allows poor electrical contacts to be detected in a timely manner.
- 21 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 9 (1) , 129-137
Detection of Poor Contacts in Low-Voltage Electrical Installations
- 21 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 9 (1) , 129-137
Detection of Poor Contacts in Low-Voltage Electrical Installations
- 4 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 8 (11) , 1905-1913
Effects of a Reduced Torque on Heating of Electrical Contacts in Plugs and Receptacles
Thermal effects of poor electrical contacts caused by a reduced torque on the wire screw terminal connections in plugs and receptacles were experimentally investigated. By changing the torque, poor connections caused by environmental vibrations or negligence by the installer were simulated. Various types and cross-sectional areas of the copper wires, as well as loads and their duration, were tested. The influence of these parameters on the contact temperature and electrical resistance, the occurrence of a hot spot, and the establishment of a series electric arc were analyzed in detail. It was shown that the poor contact degradation was caused by a constant rise of the contact resistance (caused by a growth of oxides on the contact area). It was also shown that a significant decrease in the contact temperature only slightly influences the contact resistance. However, each repetition of the heating process causes a rise of both the contact resistance and contact temperature. The research results represent an important step in developing a method for detecting poor contacts in low-voltage electrical installations by measuring the earth fault loop impedance.
- 4 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 8 (11) , 1905-1913
Effects of a Reduced Torque on Heating of Electrical Contacts in Plugs and Receptacles
Thermal effects of poor electrical contacts caused by a reduced torque on the wire screw terminal connections in plugs and receptacles were experimentally investigated. By changing the torque, poor connections caused by environmental vibrations or negligence by the installer were simulated. Various types and cross-sectional areas of the copper wires, as well as loads and their duration, were tested. The influence of these parameters on the contact temperature and electrical resistance, the occurrence of a hot spot, and the establishment of a series electric arc were analyzed in detail. It was shown that the poor contact degradation was caused by a constant rise of the contact resistance (caused by a growth of oxides on the contact area). It was also shown that a significant decrease in the contact temperature only slightly influences the contact resistance. However, each repetition of the heating process causes a rise of both the contact resistance and contact temperature. The research results represent an important step in developing a method for detecting poor contacts in low-voltage electrical installations by measuring the earth fault loop impedance.
- Open Access
- 1 January 2018
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2018, 1-9
A Mathematical Method for Determining Optimal Quantity of Backfill Materials Used for Grounding Resistance Reduction
During installation of grounding system, which represents a significant part of any electrical power system, various backfill materials are used for grounding resistance reduction. The general mathematical method for determining an optimal quantity of backfill materials used for grounding resistance reduction, based on the mathematical tools, 3D FEM modeling, numerical analysis of the obtained results, and the “knee” of the curve concept, as well as on the engineering analysis based on the designer’s experience, is developed and offered in this paper. The proposed method has been tested by applying it to a square loop enveloped by a backfill material and buried in a 2-layer soil. The results obtained by the presented method showed a good correlation with the experimentally obtained data from literature. The proposed method can help the designers to avoid the saturation areas in order to maximize efficiency of backfill material usage.
- 1 January 2018
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2018, 1-9
Open AccessA Mathematical Method for Determining Optimal Quantity of Backfill Materials Used for Grounding Resistance Reduction
During installation of grounding system, which represents a significant part of any electrical power system, various backfill materials are used for grounding resistance reduction. The general mathematical method for determining an optimal quantity of backfill materials used for grounding resistance reduction, based on the mathematical tools, 3D FEM modeling, numerical analysis of the obtained results, and the “knee” of the curve concept, as well as on the engineering analysis based on the designer’s experience, is developed and offered in this paper. The proposed method has been tested by applying it to a square loop enveloped by a backfill material and buried in a 2-layer soil. The results obtained by the presented method showed a good correlation with the experimentally obtained data from literature. The proposed method can help the designers to avoid the saturation areas in order to maximize efficiency of backfill material usage.
- 30 November 2013
- Published by Springer Nature in Electrical Engineering
- Vol. 96 (3) , 255-265
Analysis of influence of imperfect contact between grounding electrodes and surrounding soil on electrical properties of grounding loops
- 30 November 2013
- Published by Springer Nature in Electrical Engineering
- Vol. 96 (3) , 255-265
Analysis of influence of imperfect contact between grounding electrodes and surrounding soil on electrical properties of grounding loops
- Open Access
- 1 December 2012
- Published by Walter de Gruyter GmbH in Journal of Electrical Engineering
- Vol. 63 (6) , 373-379
The algorithm for determination of necessary characteristics of backfill materials used for grounding resistances of grounding loops reduction
Various backfill materials are used with the aim to reduce grounding resistance of grounding systems to the desired values. The algorithm for determination of a proper combination of features a backfill material needs to possess in order to successfully perform this task is developed and presented. It is based on the numerical analysis of the results obtained with finite-element method modelling of the considered grounding system, surrounding soil, backfill material and imperfect contact. As an example, the developed algorithm is applied on two grounding loops (one conventional and the other backfilled with bentonite suspension) embedded in a two-layer soil. The results obtained with the application of the proposed algorithm can be used as guidance for the researchers who are looking for new suitable low cost backfill materials.
- 1 December 2012
- Published by Walter de Gruyter GmbH in Journal of Electrical Engineering
- Vol. 63 (6) , 373-379
Open AccessThe algorithm for determination of necessary characteristics of backfill materials used for grounding resistances of grounding loops reduction
Various backfill materials are used with the aim to reduce grounding resistance of grounding systems to the desired values. The algorithm for determination of a proper combination of features a backfill material needs to possess in order to successfully perform this task is developed and presented. It is based on the numerical analysis of the results obtained with finite-element method modelling of the considered grounding system, surrounding soil, backfill material and imperfect contact. As an example, the developed algorithm is applied on two grounding loops (one conventional and the other backfilled with bentonite suspension) embedded in a two-layer soil. The results obtained with the application of the proposed algorithm can be used as guidance for the researchers who are looking for new suitable low cost backfill materials.