Paul Le Floch
Research Subjects
Paul Le Floch has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
- Jia Liu
John A. Paulson School of Engineering and Applied Sciences, Harvard University, Boston, MA, USA.
6 shared publications - Zhigang Suo
John A. Paulson School of Engineering and Applied Sciences, Harvard University, MA 02138, USA
4 shared publications - Boris Kozinsky
Harvard University
2 shared publications Hyunsu Park
Axoft, Inc., Cambridge, MA, USA
2 shared publicationsKewang Nan
2 shared publicationsQiang Li
School of Engineering and Applied Sciences Harvard University Boston MA 02134 USA
2 shared publications
Latest Publications
- Open Access
Clinical translation of ultrasoft Fleuron™ probes for stable, high-density, and bidirectional brain interfaces
Building brain foundation models to capture the underpinning neural dynamics of human behavior requires large functional neural datasets for training, which current implantable Brain-Computer Interfaces (iBCIs) cannot obtain due to the instability of rigid materials in the brain. How can we achieve high-density neural recordings with wide brain region access at single-neuron resolution, while maintaining long-term stability? In this study, we present a novel approach to overcome these trade-offs by introducing Fleuron, a family of ultrasoft, ultra-low-k dielectric materials compatible with thin-film scalable microfabrication techniques. We successfully integrate up to 1,024 channels within a single minimally invasive Fleuron depth electrode. The combination of the novel implant material and geometry enables single-unit level recordings for 18 months in rodent models, and achieves a large number of units detected per electrode across animals. 128-channel Fleuron probes, that cover 8× larger tissue volume than state-of-the-art polyimide counterparts, can track over 100 single-units over months. Stability in neural recordings correlates with reduced glial encapsulation compared to polyimide controls up to 9-month post-implantation. Fleuron probes are integrated with a low-power, mixed-signal ASIC to achieve over 1,000 channels electronic interfaces and can be safely implanted in depth using minimally invasive surgical techniques via a burr hole approach without requiring specialized robotics. Fleuron probes further create a unique contrast in clinical 3T MRI, allowing for post-operative position confirmation. Large-animal and ex vivo human tissue studies confirm safety and functionality in larger brains. Finally, Fleuron probes are used for the first time ever intraoperatively during planned resection surgeries, confirming in-human usability, and demonstrating the potential of the technology for clinical translation in iBCIs.
Open AccessClinical translation of ultrasoft Fleuron™ probes for stable, high-density, and bidirectional brain interfaces
Building brain foundation models to capture the underpinning neural dynamics of human behavior requires large functional neural datasets for training, which current implantable Brain-Computer Interfaces (iBCIs) cannot obtain due to the instability of rigid materials in the brain. How can we achieve high-density neural recordings with wide brain region access at single-neuron resolution, while maintaining long-term stability? In this study, we present a novel approach to overcome these trade-offs by introducing Fleuron, a family of ultrasoft, ultra-low-k dielectric materials compatible with thin-film scalable microfabrication techniques. We successfully integrate up to 1,024 channels within a single minimally invasive Fleuron depth electrode. The combination of the novel implant material and geometry enables single-unit level recordings for 18 months in rodent models, and achieves a large number of units detected per electrode across animals. 128-channel Fleuron probes, that cover 8× larger tissue volume than state-of-the-art polyimide counterparts, can track over 100 single-units over months. Stability in neural recordings correlates with reduced glial encapsulation compared to polyimide controls up to 9-month post-implantation. Fleuron probes are integrated with a low-power, mixed-signal ASIC to achieve over 1,000 channels electronic interfaces and can be safely implanted in depth using minimally invasive surgical techniques via a burr hole approach without requiring specialized robotics. Fleuron probes further create a unique contrast in clinical 3T MRI, allowing for post-operative position confirmation. Large-animal and ex vivo human tissue studies confirm safety and functionality in larger brains. Finally, Fleuron probes are used for the first time ever intraoperatively during planned resection surgeries, confirming in-human usability, and demonstrating the potential of the technology for clinical translation in iBCIs.
- Top Cited Papers
- 22 December 2023
- Published by Springer Nature in Nature Nanotechnology
- Vol. 19 (3) , 319-329
3D spatiotemporally scalable in vivo neural probes based on fluorinated elastomers
Electronic devices for recording neural activity in the nervous system need to be scalable across large spatial and temporal scales while also providing millisecond and single-cell spatiotemporal resolution. However, existing high-resolution neural recording devices cannot achieve simultaneous scalability on both spatial and temporal levels due to a trade-off between sensor density and mechanical flexibility. Here we introduce a three-dimensional (3D) stacking implantable electronic platform, based on perfluorinated dielectric elastomers and tissue-level soft multilayer electrodes, that enables spatiotemporally scalable single-cell neural electrophysiology in the nervous system. Our elastomers exhibit stable dielectric performance for over a year in physiological solutions and are 10,000 times softer than conventional plastic dielectrics. By leveraging these unique characteristics we develop the packaging of lithographed nanometre-thick electrode arrays in a 3D configuration with a cross-sectional density of 7.6 electrodes per 100 µm2. The resulting 3D integrated multilayer soft electrode array retains tissue-level flexibility, reducing chronic immune responses in mouse neural tissues, and demonstrates the ability to reliably track electrical activity in the mouse brain or spinal cord over months without disrupting animal behaviour.
- 22 December 2023
- Published by Springer Nature in Nature Nanotechnology
- Vol. 19 (3) , 319-329
Top Cited Papers3D spatiotemporally scalable in vivo neural probes based on fluorinated elastomers
Electronic devices for recording neural activity in the nervous system need to be scalable across large spatial and temporal scales while also providing millisecond and single-cell spatiotemporal resolution. However, existing high-resolution neural recording devices cannot achieve simultaneous scalability on both spatial and temporal levels due to a trade-off between sensor density and mechanical flexibility. Here we introduce a three-dimensional (3D) stacking implantable electronic platform, based on perfluorinated dielectric elastomers and tissue-level soft multilayer electrodes, that enables spatiotemporally scalable single-cell neural electrophysiology in the nervous system. Our elastomers exhibit stable dielectric performance for over a year in physiological solutions and are 10,000 times softer than conventional plastic dielectrics. By leveraging these unique characteristics we develop the packaging of lithographed nanometre-thick electrode arrays in a 3D configuration with a cross-sectional density of 7.6 electrodes per 100 µm2. The resulting 3D integrated multilayer soft electrode array retains tissue-level flexibility, reducing chronic immune responses in mouse neural tissues, and demonstrates the ability to reliably track electrical activity in the mouse brain or spinal cord over months without disrupting animal behaviour.
- 30 March 2023
- Published by Wiley in Advanced Healthcare Materials
- Vol. 12 (17) , e2202661
Pure Conducting Polymer Hydrogels Increase Signal‐to‐Noise of Cutaneous Electrodes by Lowering Skin Interface Impedance
Cutaneous electrodes are routinely used for noninvasive electrophysiological sensing of signals from the brain, the heart, and the neuromuscular system. These bioelectronic signals propagate as ionic charge from their sources to the skin–electrode interface where they are then sensed as electronic charge by the instrumentation. However, these signals suffer from low signal‐to‐noise ratio arising from the high impedance at the tissue‐to‐electrode contact interface. This paper reports that soft conductive polymer hydrogels made purely of poly(3,4‐ethylenedioxy‐thiophene) doped with poly(styrene sulfonate) present nearly an order of magnitude decrease in the skin–electrode contact impedance (88%, 82%, and 77% at 10, 100, and 1 kHz, respectively) when compared to clinical electrodes in an ex vivo model that isolates the bioelectrochemical features of a single skin–electrode contact. Integrating these pure soft conductive polymer blocks into an adhesive wearable sensor enables high fidelity bioelectronic signals with higher signal‐to‐noise ratio (average 2.1 dB increase, max 3.4 dB increase) when compared to clinical electrodes across all subjects. The utility of these electrodes is demonstrated in a neural interface application. The conductive polymer hydrogels enable electromyogram‐based velocity control of a robotic arm to complete a pick and place task. This work provides a basis for the characterization and use of conductive polymer hydrogels to better couple human and machine.
- 30 March 2023
- Published by Wiley in Advanced Healthcare Materials
- Vol. 12 (17) , e2202661
Pure Conducting Polymer Hydrogels Increase Signal‐to‐Noise of Cutaneous Electrodes by Lowering Skin Interface Impedance
Cutaneous electrodes are routinely used for noninvasive electrophysiological sensing of signals from the brain, the heart, and the neuromuscular system. These bioelectronic signals propagate as ionic charge from their sources to the skin–electrode interface where they are then sensed as electronic charge by the instrumentation. However, these signals suffer from low signal‐to‐noise ratio arising from the high impedance at the tissue‐to‐electrode contact interface. This paper reports that soft conductive polymer hydrogels made purely of poly(3,4‐ethylenedioxy‐thiophene) doped with poly(styrene sulfonate) present nearly an order of magnitude decrease in the skin–electrode contact impedance (88%, 82%, and 77% at 10, 100, and 1 kHz, respectively) when compared to clinical electrodes in an ex vivo model that isolates the bioelectrochemical features of a single skin–electrode contact. Integrating these pure soft conductive polymer blocks into an adhesive wearable sensor enables high fidelity bioelectronic signals with higher signal‐to‐noise ratio (average 2.1 dB increase, max 3.4 dB increase) when compared to clinical electrodes across all subjects. The utility of these electrodes is demonstrated in a neural interface application. The conductive polymer hydrogels enable electromyogram‐based velocity control of a robotic arm to complete a pick and place task. This work provides a basis for the characterization and use of conductive polymer hydrogels to better couple human and machine.
- Top Cited Papers
- 6 February 2022
- Published by Wiley in Advanced Materials
- Vol. 34 (11) , 2106829-e2106829
Stretchable Mesh Nanoelectronics for 3D Single‐Cell Chronic Electrophysiology from Developing Brain Organoids
Human induced pluripotent stem cell derived brain organoids have shown great potential for studies of human brain development and neurological disorders. However, quantifying the evolution of the electrical properties of brain organoids during development is currently limited by the measurement techniques, which cannot provide long‐term stable 3D bioelectrical interfaces with developing brain organoids. Here, a cyborg brain organoid platform is reported, in which “tissue‐like” stretchable mesh nanoelectronics are designed to match the mechanical properties of brain organoids and to be folded by the organogenetic process of progenitor or stem cells, distributing stretchable electrode arrays across the 3D organoids. The tissue‐wide integrated stretchable electrode arrays show no interruption to brain organoid development, adapt to the volume and morphological changes during brain organoid organogenesis, and provide long‐term stable electrical contacts with neurons within brain organoids during development. The seamless and noninvasive coupling of electrodes to neurons enables long‐term stable, continuous recording and captures the emergence of single‐cell action potentials from early‐stage brain organoid development.
- 6 February 2022
- Published by Wiley in Advanced Materials
- Vol. 34 (11) , 2106829-e2106829
Top Cited PapersStretchable Mesh Nanoelectronics for 3D Single‐Cell Chronic Electrophysiology from Developing Brain Organoids
Human induced pluripotent stem cell derived brain organoids have shown great potential for studies of human brain development and neurological disorders. However, quantifying the evolution of the electrical properties of brain organoids during development is currently limited by the measurement techniques, which cannot provide long‐term stable 3D bioelectrical interfaces with developing brain organoids. Here, a cyborg brain organoid platform is reported, in which “tissue‐like” stretchable mesh nanoelectronics are designed to match the mechanical properties of brain organoids and to be folded by the organogenetic process of progenitor or stem cells, distributing stretchable electrode arrays across the 3D organoids. The tissue‐wide integrated stretchable electrode arrays show no interruption to brain organoid development, adapt to the volume and morphological changes during brain organoid organogenesis, and provide long‐term stable electrical contacts with neurons within brain organoids during development. The seamless and noninvasive coupling of electrodes to neurons enables long‐term stable, continuous recording and captures the emergence of single‐cell action potentials from early‐stage brain organoid development.
- 15 May 2020
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 20 (6) , 4580-4587
Stretchable Electrets: Nanoparticle–Elastomer Composites
Manipulating charges is fundamental to numerous systems, and this ability is achieved through materials of diverse characteristics. This ability is achieved through materials of diverse characteristics. Electrets are dielectrics that trap charges or dipoles. Applications include electrophotography, microphones, air filters and energy harvesters. To trap charges or dipoles for a long time, electrets are commonly made of hard dielectrics. Stretchable dielectrics are short-lived electrets. The two properties—longevity and stretchability—conflict; existing electrets struggle to attain both. This work describes an approach to developing stretchable electrets. Nanoparticles of hard electret are immobilized in a matrix of dielectric elastomer. The composite divides the labor of two functions: the particles trap charges with longevity, and the matrix enables stretchability. The design considerably broadens the choice of materials to enable stretchable electrets. Silica nanoparticles in polydimethylsiloxane elastomer, achieve charge density ~ 4 × 10-5 Cm-2 and lifetime beyond 60 days. Long-lived, stretchable electrets open extensive opportunities.
- 15 May 2020
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 20 (6) , 4580-4587
Stretchable Electrets: Nanoparticle–Elastomer Composites
Manipulating charges is fundamental to numerous systems, and this ability is achieved through materials of diverse characteristics. This ability is achieved through materials of diverse characteristics. Electrets are dielectrics that trap charges or dipoles. Applications include electrophotography, microphones, air filters and energy harvesters. To trap charges or dipoles for a long time, electrets are commonly made of hard dielectrics. Stretchable dielectrics are short-lived electrets. The two properties—longevity and stretchability—conflict; existing electrets struggle to attain both. This work describes an approach to developing stretchable electrets. Nanoparticles of hard electret are immobilized in a matrix of dielectric elastomer. The composite divides the labor of two functions: the particles trap charges with longevity, and the matrix enables stretchability. The design considerably broadens the choice of materials to enable stretchable electrets. Silica nanoparticles in polydimethylsiloxane elastomer, achieve charge density ~ 4 × 10-5 Cm-2 and lifetime beyond 60 days. Long-lived, stretchable electrets open extensive opportunities.
- 27 November 2019
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 20 (1) , 224-233
Fundamental Limits to the Electrochemical Impedance Stability of Dielectric Elastomers in Bioelectronics
Incorporation of elastomers into bioelectronics that reduces the mechanical mismatch between electronics and biological systems could potentially improve the long-term electronics-tissue interface. However, the chronic stability of elastomers in physiological conditions has not been systematically studied. Here, using electrochemical impedance spectrum, we find that the electrochemical impedance of dielectric elastomers degrades over time in physiological environments. Both experimental and computational results reveal that this phenomenon is due to the diffusion of ions from the physiological solution into elastomers over time. Their conductivity increases by six orders of magnitude, up to 10-8 S/m. When the passivated conductors are also composed of intrinsically stretchable materials, higher leakage currents can be detected. Scaling analyses suggest fundamental limitations to the electrical performances of interconnects made of stretchable materials.
- 27 November 2019
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 20 (1) , 224-233
Fundamental Limits to the Electrochemical Impedance Stability of Dielectric Elastomers in Bioelectronics
Incorporation of elastomers into bioelectronics that reduces the mechanical mismatch between electronics and biological systems could potentially improve the long-term electronics-tissue interface. However, the chronic stability of elastomers in physiological conditions has not been systematically studied. Here, using electrochemical impedance spectrum, we find that the electrochemical impedance of dielectric elastomers degrades over time in physiological environments. Both experimental and computational results reveal that this phenomenon is due to the diffusion of ions from the physiological solution into elastomers over time. Their conductivity increases by six orders of magnitude, up to 10-8 S/m. When the passivated conductors are also composed of intrinsically stretchable materials, higher leakage currents can be detected. Scaling analyses suggest fundamental limitations to the electrical performances of interconnects made of stretchable materials.
- Top Cited Papers
- 26 July 2019
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 19 (8) , 5781-5789
Cyborg Organoids: Implantation of Nanoelectronics via Organogenesis for Tissue-Wide Electrophysiology
Tissue-wide electrophysiology with single-cell and millisecond spatiotemporal resolution is critical for heart and brain studies. Issues arise, however, from the invasive, localized implantation of electronics that destroys well-connected cellular networks within matured organs. Here, we report the creation of cyborg organoids: the three-dimensional (3D) assembly of soft, stretchable mesh nanoelectronics across the entire organoid by the cell–cell attraction forces from 2D-to-3D tissue reconfiguration during organogenesis. We demonstrate that stretchable mesh nanoelectronics can migrate with and grow into the initial 2D cell layers to form the 3D organoid structure with minimal impact on tissue growth and differentiation. The intimate contact between the dispersed nanoelectronics and cells enables us to chronically and systematically observe the evolution, propagation, and synchronization of the bursting dynamics in human cardiac organoids through their entire organogenesis.
- 26 July 2019
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 19 (8) , 5781-5789
Top Cited PapersCyborg Organoids: Implantation of Nanoelectronics via Organogenesis for Tissue-Wide Electrophysiology
Tissue-wide electrophysiology with single-cell and millisecond spatiotemporal resolution is critical for heart and brain studies. Issues arise, however, from the invasive, localized implantation of electronics that destroys well-connected cellular networks within matured organs. Here, we report the creation of cyborg organoids: the three-dimensional (3D) assembly of soft, stretchable mesh nanoelectronics across the entire organoid by the cell–cell attraction forces from 2D-to-3D tissue reconfiguration during organogenesis. We demonstrate that stretchable mesh nanoelectronics can migrate with and grow into the initial 2D cell layers to form the 3D organoid structure with minimal impact on tissue growth and differentiation. The intimate contact between the dispersed nanoelectronics and cells enables us to chronically and systematically observe the evolution, propagation, and synchronization of the bursting dynamics in human cardiac organoids through their entire organogenesis.
- 17 July 2018
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 10 (32) , 27333-27343
Stretchable Seal
Many stretchable electronic devices require stretchable hermetic seals. However, stretchability and permeability are inextricably linked at the molecular level: stretchable, low-permeability materials do not exit. We collect data for permeation of water and oxygen in many materials and describe the scaling relations for both flat and wrinkled seals. Whereas flat seals struggle to fulfill the simultaneous requirements of stretchability, low stiffness and low transmissibility, wrinkled seals can fulfill them readily. We further explore the behavior of wrinkled seals under cyclic stretch using aluminum, polyethylene and silica films on elastomer substrates. The wrinkled aluminum develops fatigue cracks after a small number of cycles, but the wrinkled polyethylene and silica maintain low transmissibility after 10,000 cycles of tensile strain.
- 17 July 2018
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 10 (32) , 27333-27343
Stretchable Seal
Many stretchable electronic devices require stretchable hermetic seals. However, stretchability and permeability are inextricably linked at the molecular level: stretchable, low-permeability materials do not exit. We collect data for permeation of water and oxygen in many materials and describe the scaling relations for both flat and wrinkled seals. Whereas flat seals struggle to fulfill the simultaneous requirements of stretchability, low stiffness and low transmissibility, wrinkled seals can fulfill them readily. We further explore the behavior of wrinkled seals under cyclic stretch using aluminum, polyethylene and silica films on elastomer substrates. The wrinkled aluminum develops fatigue cracks after a small number of cycles, but the wrinkled polyethylene and silica maintain low transmissibility after 10,000 cycles of tensile strain.