Christina Öhrmalm
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christina Öhrmalm has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
- Jonas Blomberg
Department of Medical Sciences, Uppsala University, Uppsala, Sweden
7 shared publications Amal Elfaitouri
Section of Clinical Microbiology, Department of Medical Sciences, Uppsala University, Uppsala, Sweden
4 shared publicationsAli Sheikholvaezin
Section of Clinical Microbiology, Department of Medical Sciences, Uppsala University, Uppsala, Sweden
3 shared publicationsAnna Sjösten
Section of Clinical Microbiology, Department of Medical Sciences, Uppsala University, Uppsala, Sweden
3 shared publicationsFredrik Blomberg
Section of Clinical Microbiology, Department of Medical Sciences, Uppsala University, Uppsala, Sweden
3 shared publications- Kåre Bondeson
Uppsala University
3 shared publications
Latest Publications
- Open Access
Low Temperature and Low UV Indexes Correlated with Peaks of Influenza Virus Activity in Northern Europe during 2010–2018
With the increasing pace of global warming, it is important to understand the role of meteorological factors in influenza virus (IV) epidemics. In this study, we investigated the impact of temperature, UV index, humidity, wind speed, atmospheric pressure, and precipitation on IV activity in Norway, Sweden, Finland, Estonia, Latvia and Lithuania during 2010–2018. Both correlation and machine learning analyses revealed that low temperature and UV indexes were the most predictive meteorological factors for IV epidemics in Northern Europe. Our in vitro experiments confirmed that low temperature and UV radiation preserved IV infectivity. Associations between these meteorological factors and IV activity could improve surveillance and promote development of accurate predictive models for future influenza outbreaks in the region.
Open AccessLow Temperature and Low UV Indexes Correlated with Peaks of Influenza Virus Activity in Northern Europe during 2010–2018
With the increasing pace of global warming, it is important to understand the role of meteorological factors in influenza virus (IV) epidemics. In this study, we investigated the impact of temperature, UV index, humidity, wind speed, atmospheric pressure, and precipitation on IV activity in Norway, Sweden, Finland, Estonia, Latvia and Lithuania during 2010–2018. Both correlation and machine learning analyses revealed that low temperature and UV indexes were the most predictive meteorological factors for IV epidemics in Northern Europe. Our in vitro experiments confirmed that low temperature and UV radiation preserved IV infectivity. Associations between these meteorological factors and IV activity could improve surveillance and promote development of accurate predictive models for future influenza outbreaks in the region.
- 1 June 2018
- Published by Elsevier in Antiviral Research
- Vol. 154, 174-182
Novel activities of safe-in-human broad-spectrum antiviral agents
- 1 June 2018
- Published by Elsevier in Antiviral Research
- Vol. 154, 174-182
Novel activities of safe-in-human broad-spectrum antiviral agents
- 1 November 2016
- Published by Elsevier in Public Health
- Vol. 140, 221-227
Reassuringly low carriage of enteropathogens among healthy Swedish children in day care centres
- 1 November 2016
- Published by Elsevier in Public Health
- Vol. 140, 221-227
Reassuringly low carriage of enteropathogens among healthy Swedish children in day care centres
- Open Access
- 1 January 2016
- Published by Taylor & Francis in BioTechniques
- Vol. 60 (1) , 28-34
Development of Single-Tube Nested Real-Time PCR Assays with Long Internally Quenched Probes for Detection of Norovirus Genogroup II
The high sequence variation of RNA viruses necessitates use of degenerate primers and probes or multiple primers and probes in molecular diagnostic assays. We showed previously that PCR amplification in two rounds, first with long...
- 1 January 2016
- Published by Taylor & Francis in BioTechniques
- Vol. 60 (1) , 28-34
Open AccessDevelopment of Single-Tube Nested Real-Time PCR Assays with Long Internally Quenched Probes for Detection of Norovirus Genogroup II
The high sequence variation of RNA viruses necessitates use of degenerate primers and probes or multiple primers and probes in molecular diagnostic assays. We showed previously that PCR amplification in two rounds, first with long...
- Open Access
- 4 November 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (11) , e111874
Detection of Rotavirus Using Padlock Probes and Rolling Circle Amplification
Rotavirus infections are one of the most common reasons for hospitalizations due to gastrointestinal diseases. Rotavirus is often diagnosed by latex agglutination assay, chromatography immunoassay, or by electron microscopy, which are all quite insensitive. Reverse transcription polymerase chain reaction, on the other hand, is very sensitive to variations at the genomic level. We developed a novel assay based on a set of 58 different padlock probes with a detection limit of 1,000 copies. Twenty-two patient samples were analyzed and the assay showed high concordance with a PCR-based assay. In summary, we present a new assay for sensitive and variation tolerant detection of rotavirus.
- 4 November 2014
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (11) , e111874
Open AccessDetection of Rotavirus Using Padlock Probes and Rolling Circle Amplification
Rotavirus infections are one of the most common reasons for hospitalizations due to gastrointestinal diseases. Rotavirus is often diagnosed by latex agglutination assay, chromatography immunoassay, or by electron microscopy, which are all quite insensitive. Reverse transcription polymerase chain reaction, on the other hand, is very sensitive to variations at the genomic level. We developed a novel assay based on a set of 58 different padlock probes with a detection limit of 1,000 copies. Twenty-two patient samples were analyzed and the assay showed high concordance with a PCR-based assay. In summary, we present a new assay for sensitive and variation tolerant detection of rotavirus.
- Open Access
- 1 October 2012
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 50 (10) , 3208-3215
Variation-Tolerant Capture and Multiplex Detection of Nucleic Acids: Application to Detection of Microbes
In contrast to ordinary PCRs, which have a limited multiplex capacity and often return false-negative results due to target variation or inhibition, our new detection strategy, VOCMA ( v ariation-t o lerant c apture m ultiplex a ssay), allows variation-tolerant, target-specific capture and detection of many nucleic acids in one test. Here we demonstrate the use of a single-tube, dual-step amplification strategy that overcomes the usual limitations of PCR multiplexing, allowing at least a 22-plex format with retained sensitivity. Variation tolerance was achieved using long primers and probes designed to withstand variation at known sites and a judicious mix of degeneration and universal bases. We tested VOCMA in situations where enrichment from a large sample volume with high sensitivity and multiplexity is important (sepsis; streptococci, enterococci, and staphylococci, several enterobacteria, candida, and the most important antibiotic resistance genes) and where variation tolerance and high multiplexity is important (gastroenteritis; astrovirus, adenovirus, rotavirus, norovirus genogroups I and II, and sapovirus, as well as enteroviruses, which are not associated with gastroenteritis). Detection sensitivities of 10 to 1,000 copies per reaction were achieved for many targets. VOCMA is a highly multiplex, variation-tolerant, general purpose nucleic acid detection concept. It is a specific and sensitive method for simultaneous detection of nucleic acids from viruses, bacteria, fungi, and protozoa, as well as host nucleic acid, in the same test. It can be run on an ordinary PCR and a Luminex machine and is suitable for both clinical diagnoses and microbial surveillance.
- 1 October 2012
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 50 (10) , 3208-3215
Open AccessVariation-Tolerant Capture and Multiplex Detection of Nucleic Acids: Application to Detection of Microbes
In contrast to ordinary PCRs, which have a limited multiplex capacity and often return false-negative results due to target variation or inhibition, our new detection strategy, VOCMA ( v ariation-t o lerant c apture m ultiplex a ssay), allows variation-tolerant, target-specific capture and detection of many nucleic acids in one test. Here we demonstrate the use of a single-tube, dual-step amplification strategy that overcomes the usual limitations of PCR multiplexing, allowing at least a 22-plex format with retained sensitivity. Variation tolerance was achieved using long primers and probes designed to withstand variation at known sites and a judicious mix of degeneration and universal bases. We tested VOCMA in situations where enrichment from a large sample volume with high sensitivity and multiplexity is important (sepsis; streptococci, enterococci, and staphylococci, several enterobacteria, candida, and the most important antibiotic resistance genes) and where variation tolerance and high multiplexity is important (gastroenteritis; astrovirus, adenovirus, rotavirus, norovirus genogroups I and II, and sapovirus, as well as enteroviruses, which are not associated with gastroenteritis). Detection sensitivities of 10 to 1,000 copies per reaction were achieved for many targets. VOCMA is a highly multiplex, variation-tolerant, general purpose nucleic acid detection concept. It is a specific and sensitive method for simultaneous detection of nucleic acids from viruses, bacteria, fungi, and protozoa, as well as host nucleic acid, in the same test. It can be run on an ordinary PCR and a Luminex machine and is suitable for both clinical diagnoses and microbial surveillance.
- Open Access
- 1 September 2012
- Published by American Society for Microbiology in Clinical and Vaccine Immunology
- Vol. 19 (9) , 1399-1410
No Evidence for Xenotropic Murine Leukemia-Related Virus Infection in Sweden Using Internally Controlled Multiepitope Suspension Array Serology
Many syndromes have a large number of differential diagnoses, a situation which calls for multiplex diagnostic systems. Myalgic encephalomyelitis (ME), also named chronic fatigue syndrome (CFS), is a common disease of unknown etiology. A mouse retrovirus, xenotropic murine leukemia-related virus (XMRV), was found in ME/CFS patients and blood donors, but this was not corroborated. However, the paucity of serological investigations on XMRV in humans prompted us to develop a serological assay which cover many aspects of XMRV antigenicity. It is a novel suspension array method, using a multiplex IgG assay with nine recombinant proteins from the env and gag genes of XMRV and 38 peptides based on known epitopes of vertebrate gammaretroviruses. IgG antibodies were sought in 520 blood donors and 85 ME/CFS patients and in positive- and negative-control sera from animals. We found no differences in seroreactivity between blood donors and ME/CFS patients for any of the antigens. This did not support an association between ME/CFS and XMRV infection. The multiplex serological system had several advantages: (i) biotinylated protein G allowed us to run both human and animal sera, which is essential because of a lack of XMRV-positive humans; (ii) a novel quality control was a pan-peptide positive-control rabbit serum; and (iii) synthetic XMRV Gag peptides with degenerate positions covering most of the variation of murine leukemia-like viruses did not give higher background than nondegenerate analogs. The principle may be used for creation of variant tolerant peptide serologies. Thus, our system allows rational large-scale serological assays with built-in quality control.
- 1 September 2012
- Published by American Society for Microbiology in Clinical and Vaccine Immunology
- Vol. 19 (9) , 1399-1410
Open AccessNo Evidence for Xenotropic Murine Leukemia-Related Virus Infection in Sweden Using Internally Controlled Multiepitope Suspension Array Serology
Many syndromes have a large number of differential diagnoses, a situation which calls for multiplex diagnostic systems. Myalgic encephalomyelitis (ME), also named chronic fatigue syndrome (CFS), is a common disease of unknown etiology. A mouse retrovirus, xenotropic murine leukemia-related virus (XMRV), was found in ME/CFS patients and blood donors, but this was not corroborated. However, the paucity of serological investigations on XMRV in humans prompted us to develop a serological assay which cover many aspects of XMRV antigenicity. It is a novel suspension array method, using a multiplex IgG assay with nine recombinant proteins from the env and gag genes of XMRV and 38 peptides based on known epitopes of vertebrate gammaretroviruses. IgG antibodies were sought in 520 blood donors and 85 ME/CFS patients and in positive- and negative-control sera from animals. We found no differences in seroreactivity between blood donors and ME/CFS patients for any of the antigens. This did not support an association between ME/CFS and XMRV infection. The multiplex serological system had several advantages: (i) biotinylated protein G allowed us to run both human and animal sera, which is essential because of a lack of XMRV-positive humans; (ii) a novel quality control was a pan-peptide positive-control rabbit serum; and (iii) synthetic XMRV Gag peptides with degenerate positions covering most of the variation of murine leukemia-like viruses did not give higher background than nondegenerate analogs. The principle may be used for creation of variant tolerant peptide serologies. Thus, our system allows rational large-scale serological assays with built-in quality control.
- Open Access
- 1 December 2011
- Published by Elsevier in Protein Expression and Purification
- Vol. 80 (2) , 176-184
Rational recombinant XMRV antigen preparation and bead coupling for multiplex serology in a suspension array
- 1 December 2011
- Published by Elsevier in Protein Expression and Purification
- Vol. 80 (2) , 176-184
Open AccessRational recombinant XMRV antigen preparation and bead coupling for multiplex serology in a suspension array
- Open Access
- 12 October 2011
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 6 (10) , e24602
Murine Gammaretrovirus Group G3 Was Not Found in Swedish Patients with Myalgic Encephalomyelitis/Chronic Fatigue Syndrome and Fibromyalgia
The recent report of gammaretroviruses of probable murine origin in humans, called xenotropic murine retrovirus related virus (XMRV) and human murine leukemia virus related virus (HMRV), necessitated a bioinformatic search for this virus in genomes of the mouse and other vertebrates, and by PCR in humans. Three major groups of murine endogenous gammaretroviruses were identified. The third group encompassed both exogenous and endogenous Murine Leukemia Viruses (MLVs), and most XMRV/HMRV sequences reported from patients suffering from myalgic encephalomyelitis/chronic fatigue syndrome (ME/CFS). Two sensitive real-time PCRs for this group were developed. The predicted and observed amplification range for these and three published XMRV/HMRV PCRs demonstrated conspicuous differences between some of them, partly explainable by a recombinatorial origin of XMRV. Three reverse transcription real-time PCRs (RTQPCRs), directed against conserved and not overlapping stretches of env, gag and integrase (INT) sequences of XMRV/HMRV were used on human samples. White blood cells from 78 patients suffering from ME/CFS, of which 30 patients also fulfilled the diagnostic criteria for fibromyalgia (ME/CFS/FM) and in 7 patients with fibromyalgia (FM) only, all from the Gothenburg area of Sweden. As controls we analyzed 168 sera from Uppsala blood donors. We controlled for presence and amplifiability of nucleic acid and for mouse DNA contamination. To score as positive, a sample had to react with several of the XMRV/HMRV PCRs. None of the samples gave PCR reactions which fulfilled the positivity criteria. XMRV/HMRV like proviruses occur in the third murine gammaretrovirus group, characterized here. PCRs developed by us, and others, approximately cover this group, except for the INT RTQPCR, which is rather strictly XMRV specific. Using such PCRs, XMRV/HMRV could not be detected in PBMC and plasma samples from Swedish patients suffering from ME/CFS/FM, and in sera from Swedish blood donors.
- 12 October 2011
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 6 (10) , e24602
Open AccessMurine Gammaretrovirus Group G3 Was Not Found in Swedish Patients with Myalgic Encephalomyelitis/Chronic Fatigue Syndrome and Fibromyalgia
The recent report of gammaretroviruses of probable murine origin in humans, called xenotropic murine retrovirus related virus (XMRV) and human murine leukemia virus related virus (HMRV), necessitated a bioinformatic search for this virus in genomes of the mouse and other vertebrates, and by PCR in humans. Three major groups of murine endogenous gammaretroviruses were identified. The third group encompassed both exogenous and endogenous Murine Leukemia Viruses (MLVs), and most XMRV/HMRV sequences reported from patients suffering from myalgic encephalomyelitis/chronic fatigue syndrome (ME/CFS). Two sensitive real-time PCRs for this group were developed. The predicted and observed amplification range for these and three published XMRV/HMRV PCRs demonstrated conspicuous differences between some of them, partly explainable by a recombinatorial origin of XMRV. Three reverse transcription real-time PCRs (RTQPCRs), directed against conserved and not overlapping stretches of env, gag and integrase (INT) sequences of XMRV/HMRV were used on human samples. White blood cells from 78 patients suffering from ME/CFS, of which 30 patients also fulfilled the diagnostic criteria for fibromyalgia (ME/CFS/FM) and in 7 patients with fibromyalgia (FM) only, all from the Gothenburg area of Sweden. As controls we analyzed 168 sera from Uppsala blood donors. We controlled for presence and amplifiability of nucleic acid and for mouse DNA contamination. To score as positive, a sample had to react with several of the XMRV/HMRV PCRs. None of the samples gave PCR reactions which fulfilled the positivity criteria. XMRV/HMRV like proviruses occur in the third murine gammaretrovirus group, characterized here. PCRs developed by us, and others, approximately cover this group, except for the INT RTQPCR, which is rather strictly XMRV specific. Using such PCRs, XMRV/HMRV could not be detected in PBMC and plasma samples from Swedish patients suffering from ME/CFS/FM, and in sera from Swedish blood donors.
- Open Access
- 4 September 2011
- Published by Hindawi Limited in Advances in Virology
- Vol. 2011, 1-20
Phylogeny-Directed Search for Murine Leukemia Virus-Like Retroviruses in Vertebrate Genomes and in Patients Suffering from Myalgic Encephalomyelitis/Chronic Fatigue Syndrome and Prostate Cancer
Gammaretrovirus-like sequences occur in most vertebrate genomes. Murine Leukemia Virus (MLV) like retroviruses (MLLVs) are a subset, which may be pathogenic and spread cross-species. Retroviruses highly similar to MLLVs (xenotropic murine retrovirus related virus (XMRV) and Human Mouse retrovirus-like RetroViruses (HMRVs)) reported from patients suffering from prostate cancer (PC) and myalgic encephalomyelitis/chronic fatigue syndrome (ME/CFS) raise the possibility that also humans have been infected. Structurally intact, potentially infectious MLLVs occur in the genomes of some mammals, especially mouse. Mouse MLLVs contain three major groups. One, MERV G3, contained MLVs and XMRV/HMRV. Its presence in mouse DNA, and the abundance of xenotropic MLVs in biologicals, is a source of false positivity. Theoretically, XMRV/HMRV could be one of several MLLV transspecies infections. MLLV pathobiology and diversity indicate optimal strategies for investigating XMRV/HMRV in humans and raise ethical concerns. The alternatives that XMRV/HMRV may give a hard-to-detect “stealth” infection, or that XMRV/HMRV never reached humans, have to be considered.
- 4 September 2011
- Published by Hindawi Limited in Advances in Virology
- Vol. 2011, 1-20
Open AccessPhylogeny-Directed Search for Murine Leukemia Virus-Like Retroviruses in Vertebrate Genomes and in Patients Suffering from Myalgic Encephalomyelitis/Chronic Fatigue Syndrome and Prostate Cancer
Gammaretrovirus-like sequences occur in most vertebrate genomes. Murine Leukemia Virus (MLV) like retroviruses (MLLVs) are a subset, which may be pathogenic and spread cross-species. Retroviruses highly similar to MLLVs (xenotropic murine retrovirus related virus (XMRV) and Human Mouse retrovirus-like RetroViruses (HMRVs)) reported from patients suffering from prostate cancer (PC) and myalgic encephalomyelitis/chronic fatigue syndrome (ME/CFS) raise the possibility that also humans have been infected. Structurally intact, potentially infectious MLLVs occur in the genomes of some mammals, especially mouse. Mouse MLLVs contain three major groups. One, MERV G3, contained MLVs and XMRV/HMRV. Its presence in mouse DNA, and the abundance of xenotropic MLVs in biologicals, is a source of false positivity. Theoretically, XMRV/HMRV could be one of several MLLV transspecies infections. MLLV pathobiology and diversity indicate optimal strategies for investigating XMRV/HMRV in humans and raise ethical concerns. The alternatives that XMRV/HMRV may give a hard-to-detect “stealth” infection, or that XMRV/HMRV never reached humans, have to be considered.