Rafael Leiva-Garcia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rafael Leiva-Garcia has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Jose García Antón
Universitat Politècnica de València
14 shared publications - María José Muñoz Portero
Ingeniería Electroquímica y Corrosión (IEC), Instituto Universitario de Seguridad Industrial, Radiofísica y Medioambiental (ISIRYM), Universitat Politècnica de València, C/Camino de Vera s/n, 46022 Valencia, Spain
8 shared publications R. Akid
4 shared publications- Rita Sánchez-Tovar
Department of Chemical Engineering (ETSE), Universitat de València, Av. Universitat s/n, 46100 Burjassot-Valencia, Spain
4 shared publications - Ramon Manuel Fernández-Domene
Department of Chemical Engineering (ETSE), Universitat de València, Av. Universitat s/n, 46100 Burjassot-Valencia, Spain
3 shared publications - Ariadna García‐Herraiz
Special Patient Unit Department of Stomatology University of Valencia Valencia Spain
2 shared publications
Latest Publications
- 10 June 2020
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 12 (27) , 30833-30846
Smart Functionalization of Ceramic-Coated AZ31 Magnesium Alloy
Providing materials with smart functionalities such as self-healing properties is primarily a domain for organic materials, although their applicability is restricted to mild environments and loads because of poor thermal and mechanical properties. This work seeks to achieve the active functionalities obtained in organic materials but in ceramics, which are much more heat resistant and robust. Ceramic coatings were produced by plasma electrolytic oxidation (PEO), which is an environmentally friendly technique that offers an alternative to potentially carcinogenic treatments used widely in the automotive and aircraft industries to protect light alloys against corrosion. The active functionalization was achieved by incorporating corrosion inhibitors encapsulated into halloysite nanotubes (HNTs) into the PEO coatings. This allowed controlled release of active agents when detecting environmental pH changes associated with the corrosion initiation of the metal substrate. Three corrosion inhibitors—vanadate, molybdate salts, and 8-hydroxyquinoline (8-HQ)—were assessed within the PEO–HNT system and demonstrated considerable improvements in the corrosion resistance by decreasing the kinetics of both anodic and cathodic reactions. For immersion times up to 72 h, vanadate offered a consistently higher corrosion resistance, which was followed by molybdate, whereas the positive effect of 8-HQ was time-limited. The improvement in corrosion resistance was associated with the combined enhancement of the barrier and active protection properties of ceramic coatings. All coatings containing corrosion inhibitors were capable of providing self-healing to small scratches, whereas only vanadate could partially restore a more severe damage.
- 10 June 2020
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 12 (27) , 30833-30846
Smart Functionalization of Ceramic-Coated AZ31 Magnesium Alloy
Providing materials with smart functionalities such as self-healing properties is primarily a domain for organic materials, although their applicability is restricted to mild environments and loads because of poor thermal and mechanical properties. This work seeks to achieve the active functionalities obtained in organic materials but in ceramics, which are much more heat resistant and robust. Ceramic coatings were produced by plasma electrolytic oxidation (PEO), which is an environmentally friendly technique that offers an alternative to potentially carcinogenic treatments used widely in the automotive and aircraft industries to protect light alloys against corrosion. The active functionalization was achieved by incorporating corrosion inhibitors encapsulated into halloysite nanotubes (HNTs) into the PEO coatings. This allowed controlled release of active agents when detecting environmental pH changes associated with the corrosion initiation of the metal substrate. Three corrosion inhibitors—vanadate, molybdate salts, and 8-hydroxyquinoline (8-HQ)—were assessed within the PEO–HNT system and demonstrated considerable improvements in the corrosion resistance by decreasing the kinetics of both anodic and cathodic reactions. For immersion times up to 72 h, vanadate offered a consistently higher corrosion resistance, which was followed by molybdate, whereas the positive effect of 8-HQ was time-limited. The improvement in corrosion resistance was associated with the combined enhancement of the barrier and active protection properties of ceramic coatings. All coatings containing corrosion inhibitors were capable of providing self-healing to small scratches, whereas only vanadate could partially restore a more severe damage.
- 1 June 2018
- Published by Elsevier in Theoretical and Applied Fracture Mechanics
- Vol. 95, 253-260
Strain evolution around corrosion pits under fatigue loading
- 1 June 2018
- Published by Elsevier in Theoretical and Applied Fracture Mechanics
- Vol. 95, 253-260
Strain evolution around corrosion pits under fatigue loading
- Open Access
- 1 June 2018
- Published by Elsevier in Corrosion Science
- Vol. 137, 83-97
Simulation of stress-assisted localised corrosion using a cellular automaton finite element approach
- 1 June 2018
- Published by Elsevier in Corrosion Science
- Vol. 137, 83-97
Open AccessSimulation of stress-assisted localised corrosion using a cellular automaton finite element approach
- 1 January 2018
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 249, 1113-1124
Effectiveness of O -bridged cationic gemini surfactants as corrosion inhibitors for stainless steel in 3 M HCl: Experimental and theoretical studies
- 1 January 2018
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 249, 1113-1124
Effectiveness of O -bridged cationic gemini surfactants as corrosion inhibitors for stainless steel in 3 M HCl: Experimental and theoretical studies
- 1 December 2017
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 247, 6-13
Efficiency of cationic gemini surfactants with 3-azamethylpentamethylene spacer as corrosion inhibitors for stainless steel in hydrochloric acid
- 1 December 2017
- Published by Elsevier in Journal of Molecular Liquids
- Vol. 247, 6-13
Efficiency of cationic gemini surfactants with 3-azamethylpentamethylene spacer as corrosion inhibitors for stainless steel in hydrochloric acid
- 16 February 2017
- Published by Wiley in Journal of Clinical Periodontology
- Vol. 44 (5) , 548-555
Post‐extraction mesio‐distal gap reduction assessment by confocal laser scanning microscopy – a clinical 3‐month follow‐up study
Aim: The aim of this 3‐month follow‐up study is to quantify the reduction in the mesio‐distal gap dimension (MDGD) that occurs after tooth extraction through image analysis of three‐dimensional images obtained with the confocal laser scanning microscopy (CLSM) technique.Materials and Methods: Following tooth extraction, impressions of 79 patients 1 month and 72 patients 3 months after tooth extraction were obtained. Cast models were processed by CLSM, and MDGD changes between time points were measured.Results: The mean mesio‐distal gap reduction 1 month after tooth extraction was 343.4 μm and 3 months after tooth extraction was 672.3 μm. The daily mean gap reduction rate during the first term (between baseline and 1 month post‐extraction measurements) was 10.3 μm/day and during the second term (between 1 and 3 months) was 5.4 μm/day.Conclusions: The mesio‐distal gap reduction is higher during the first month following the extraction and continues in time, but to a lesser extent. When the inter‐dental contacts were absent, the mesio‐distal gap reduction is lower. When a molar tooth is extracted or the distal tooth to the edentulous space does not occlude with an antagonist, the mesio‐distal gap reduction is larger. The consideration of mesio‐distal gap dimension changes can help improve dental treatment planning.
- 16 February 2017
- Published by Wiley in Journal of Clinical Periodontology
- Vol. 44 (5) , 548-555
Post‐extraction mesio‐distal gap reduction assessment by confocal laser scanning microscopy – a clinical 3‐month follow‐up study
Aim: The aim of this 3‐month follow‐up study is to quantify the reduction in the mesio‐distal gap dimension (MDGD) that occurs after tooth extraction through image analysis of three‐dimensional images obtained with the confocal laser scanning microscopy (CLSM) technique.Materials and Methods: Following tooth extraction, impressions of 79 patients 1 month and 72 patients 3 months after tooth extraction were obtained. Cast models were processed by CLSM, and MDGD changes between time points were measured.Results: The mean mesio‐distal gap reduction 1 month after tooth extraction was 343.4 μm and 3 months after tooth extraction was 672.3 μm. The daily mean gap reduction rate during the first term (between baseline and 1 month post‐extraction measurements) was 10.3 μm/day and during the second term (between 1 and 3 months) was 5.4 μm/day.Conclusions: The mesio‐distal gap reduction is higher during the first month following the extraction and continues in time, but to a lesser extent. When the inter‐dental contacts were absent, the mesio‐distal gap reduction is lower. When a molar tooth is extracted or the distal tooth to the edentulous space does not occlude with an antagonist, the mesio‐distal gap reduction is larger. The consideration of mesio‐distal gap dimension changes can help improve dental treatment planning.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 705-710
Design of an FPGA-based eddy current instrument for the detection of corrosion pits
This paper presents a method for pitting corrosion detection using a custom developed instrument based on the eddy current testing principle. Previously, eddy current testing has been used in NDT applications where large features such as cracks are detected. However, for pitting corrosion of a size of the order of 0.1mm remains a challenge. In this paper we discuss the development of a highly integrated, Field Programmable Gate Array (FPGA)-based digital single-frequency eddy current instrument, which has high sensitivity and is capable of detecting corrosion pits in metallic plates. Pits with controlled size were created by a micro-capillary technique operating under galvanostatic control. Experimental results show that pits created with sizes of order of 100-450 μm depth can be reliably detected and there is a good correlation between the size of the pit and the amplitude of the signal from the instrument.
- 1 May 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 705-710
Design of an FPGA-based eddy current instrument for the detection of corrosion pits
This paper presents a method for pitting corrosion detection using a custom developed instrument based on the eddy current testing principle. Previously, eddy current testing has been used in NDT applications where large features such as cracks are detected. However, for pitting corrosion of a size of the order of 0.1mm remains a challenge. In this paper we discuss the development of a highly integrated, Field Programmable Gate Array (FPGA)-based digital single-frequency eddy current instrument, which has high sensitivity and is capable of detecting corrosion pits in metallic plates. Pits with controlled size were created by a micro-capillary technique operating under galvanostatic control. Experimental results show that pits created with sizes of order of 100-450 μm depth can be reliably detected and there is a good correlation between the size of the pit and the amplitude of the signal from the instrument.
- 1 May 2015
- Published by Elsevier in Corrosion Science
- Vol. 94, 327-341
Study of the sensitisation process of a duplex stainless steel (UNS 1.4462) by means of confocal microscopy and localised electrochemical techniques
- 1 May 2015
- Published by Elsevier in Corrosion Science
- Vol. 94, 327-341
Study of the sensitisation process of a duplex stainless steel (UNS 1.4462) by means of confocal microscopy and localised electrochemical techniques
- Open Access
- 17 February 2015
- Published by Wiley in Materials and Corrosion
- Vol. 66 (11) , 1279-1289
Comparison of the effect of non-polluted and underwater-volcano-polluted seawater on the corrosion resistance of different stainless steels
- 17 February 2015
- Published by Wiley in Materials and Corrosion
- Vol. 66 (11) , 1279-1289
Open AccessComparison of the effect of non-polluted and underwater-volcano-polluted seawater on the corrosion resistance of different stainless steels
- 1 February 2015
- Published by Elsevier in Thin Solid Films
- Vol. 576, 1-10
Characterization of thermal oxide films formed on a duplex stainless steel by means of confocal-Raman microscopy and electrochemical techniques
- 1 February 2015
- Published by Elsevier in Thin Solid Films
- Vol. 576, 1-10
Characterization of thermal oxide films formed on a duplex stainless steel by means of confocal-Raman microscopy and electrochemical techniques