DMDarya Mozhayeva

Darya Mozhayeva

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Darya Mozhayeva has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Carsten Engelhard

    Department of Chemistry and Biology and Research Center of Micro- and Nanochemistry and (Bio)Technology (Cμ), University of Siegen, Siegen, Germany

    7 shared publications
  • Anna Beasley

    Research Group of Ecology and Behavioural Biology, Institute of Biology, Department of Chemistry-Biology, University of Siegen, Adolf-Reichwein-Strasse 2, Siegen, 57076, Germany

    1 shared publication
  • Antje Vennemann

    IBE R&D Institute for Lung Health gGmbH, 48149 Münster, Germany

    1 shared publication
  • Bastian T. F. Spelz

    Analytical Chemistry, Department of Chemistry-Biology, University of Siegen, Adolf-Reichwein-Strasse 2, 57076 Siegen, Germany

    1 shared publication
  • Benedikt Steinhoff

    Physical Chemistry I, Department of Chemistry-Biology, University of Siegen, Adolf-Reichwein-Strasse 2, 57076 Siegen, Germany

    1 shared publication
  • Benjamin Butz

    University of Siegen

    1 shared publication

Latest Publications

  • Calibration Strategy to Size and Localize Multi-Shaped Nanoparticles in Tissue Sections Using LA–spICP–MS

    by Svenja B. Seiffert, Matthias Elinkmann, Erik Niehaves, Antje Vennemann, Darya Mozhayeva, Sabrina Kröger, Martin Wiemann, Uwe Karst

    In the field of nanotoxicology, the detection and size characterization of nanoparticles (NPs) in biological tissues become increasingly important. To gain information on both particle size and particle distribution in histological sections, laser ablation and single particle inductively coupled plasma-mass spectrometry (LA-spICP-MS) was used in combination with a liquid calibration of dissolved metal standards via a pneumatic nebulizer. In the first step, the particle size distribution of Ag NPs embedded in matrix-matched gelatine standards introduced via LA was compared with that of Ag NPs in a suspension and nebulizer-based ICP-MS. The data show that the particles remained intact by the ablation process as confirmed by transmission electron microscopy. Moreover, the optimized method was applied to CeO2 NPs that are highly relevant for (eco-)toxicological research but, unlike Ag NPs, are multi-shaped and have a broad particle size distribution. Upon analyzing the particle size distribution of CeO2 NPs in cryosections of rat spleen, CeO2 NPs were found to remain unchanged in size over 3 h, 3 d, and 3 weeks post-intratracheal instillation, with the fraction of smaller particles reaching the spleen first. Overall, LA-spICP-MS combined with a calibration based on dissolved metal standards is a powerful tool to simultaneously localize and size NPs in histological sections in the absence of particle standards.


  • CE Coupled to ICP-MS and Single Particle ICP-MS for Nanoparticle Analysis

    by Darya Mozhayeva, Carsten Engelhard

    Capillary electrophoresis (CE) can be used for the separation of nanoparticles (NPs). Coupling of CE to inductively coupled plasma mass spectrometry (ICP-MS) or single particle (sp)-ICP-MS enhances the analytical performance and capabilities of the method compared to CE with a standard detector (ultraviolet visible spectroscopy), in particular for trace analysis of metals or metal-containing compounds. spICP-MS is a method for NP analysis, where a standard ICP-MS setup is used with fast time-resolved detection in order to obtain information on individual NPs. Here we describe a method for the separation and detection of silver and gold NPs using CE-ICP-MS and CE-spICP-MS with reversed electrode polarity stacking mode (REPSM) for online preconcentration. CE-spICP-MS allows obtaining the average size, size distribution, elemental composition, and particle number concentration (PNC) of NPs in addition to a CE separation profile in a single run. Moreover, CE-spICP-MS can be used in some cases to separate NPs with different coatings. Key words Nanomaterials Single particle ICP-MS spICP-MS MEKC SDS Micelles Microsecond time resolution Transient detection


  • Investigation of the Fate of Silver and Titanium Dioxide Nanoparticles in Model Wastewater Effluents via Selected Area Electron Diffraction

    by Benedikt Steinhoff, Julian Müller, Darya Mozhayeva, Bastian T. F. Spelz, Carsten Engelhard, Benjamin Butz, Holger Schönherr

    The increasing use of manufactured nanomaterials (MNMs) and their inevitable release into the environment, especially via wastewater treatment plants (WWTPs), poses a potential threat for aquatic organisms. The characterization of MNMs with analytical tools to comprehend their fate and effect on the ecosystem is hence of great importance for environmental risk assessment. We herein report, for the first time, the investigation of physicochemical transformation processes during artificial wastewater treatment of silver (Ag-NPs) and titanium dioxide nanoparticles (TiO2-NPs) via selected area electron diffraction (SAED). TiO2-NPs with an anatase/rutile ratio of ∼80/20 were found to not undergo any physicochemical transformation, as shown via previous energy-dispersive X-ray analysis (EDX) elemental mapping and crystal structure analysis via SAED. In contrast, Ag-NPs were colocalized with substantial amounts of sulfur (Ag/S ratio of 1.9), indicating the formation of Ag2S. SAED ultimately proved the complete transformation of face-centered cubic (fcc) Ag-NPs into monoclinic Ag2S-NPs. The size distribution of both nanomaterials remained virtually unchanged. Our investigations show that cloud point extraction of NPs and their subsequent crystal structure analysis via SAED is another valuable approach toward the comprehensive investigation of wastewater-borne MNMs. However, the extraction procedure needs optimization for environmentally low NP concentrations.


  • Open Access

    Defective defence in Daphnia daughters: silver nanoparticles inhibit anti-predator defence in offspring but not in maternal Daphnia magna

    by Sarah Hartmann, Anna Beasley, Darya Mozhayeva, Carsten Engelhard, Klaudia Witte

    One major environmental problem of our time are emerging contaminants in the aquatic environment. While nanoparticles exhibit attractive features such as antimicrobial properties in the case of silver nanoparticles (AgNPs), earlier studies suggest that NPs are not completely filtered out at wastewater treatment plants and may therefore be continuously introduced into the aquatic environment. Although adverse effects of AgNPs on aquatic organisms have been extensively studied, there is still a lack of knowledge on how this chemical stressor interacts with natural cues on the maternal and subsequent generation of aquatic organisms. We tested whether AgNPs (NM-300K, 14.9 ± 2.4 nm, concentration range: 2.5 µg/L – 20 µg/L) affect the kairomone-induced adaptive anti-predator defence mechanism in maternal Daphnia and their offspring. While maternal Daphnia developed typical anti-predator defence mechanisms when exposed to kairomones and AgNPs, their offspring could not develop such adaptive defensive traits. The lack of this defence mechanism in offspring could have dramatic negative consequences (e.g. reduced Daphnia population) for the entire complex food web in the aquatic ecosystem. For a realistic risk assessment, it is extremely important to test combinations of chemical stressors because aquatic organisms are exposed to several natural and artificial chemical stressors at the same time.


  • Top Cited Papers
    Open Access

    A critical review of single particle inductively coupled plasma mass spectrometry – A step towards an ideal method for nanomaterial characterization

    by Darya Mozhayeva, Carsten Engelhard

    Single particle inductively coupled plasma mass spectrometry (spICP-MS or SP-ICP-MS depending on the author) is becoming an important tool for the characterization of nanoparticles (NPs). The method allows to determine size, size distribution, and particle number concentrations of NPs in suspensions after a mere few minutes of measurement. This review is modeled after the concept of “an ideal method for atomic spectroscopy” introduced by Gary M. Hieftje in his publication dedicated to Howard Malmstadt.1 This review discusses the instrumental developments in spICP-MS of recent years step-by-step, from the sample introduction system to the detector. The authors identify necessary improvements and suggest directions for further developments which have the potential to bring the method closer to “an ideal method for atomic spectroscopy”. The review also discusses literature on coupling spICP-MS to separation and fractionation techniques including capillary electrophoresis (CE), field flow fractionation (FFF), and differential mobility analysis (DMA). The second part of the review is dedicated to applications of spICP-MS. Key steps in sample preparation and selected instrumental conditions that were used in the published literature are summarized in tabular form. Most frequently, spICP-MS is used for silver (Ag), gold (Au), and titanium dioxide (TiO2) nanomaterials analysis. Data acquisition was typically performed with millisecond dwell times in the past while a time resolution of hundreds of microseconds has been used more often in the last five years. The table may serve as a guide to choose an experimental procedure depending on the matrix that is present in the sample under investigation.


  • Open Access

    A quantitative nanoparticle extraction method for microsecond time resolved single-particle ICP-MS data in the presence of a high background

    by Darya Mozhayeva, Carsten Engelhard

    The detection of nanoparticles (NPs) in the presence of a high background (BG) is challenging in single particle inductively coupled plasma mass spectrometry (SP-ICP-MS) and leads to inaccurate quantification. In this study, we report a data processing procedure for the deconvolution of SP-ICP-MS data and its application to quantification of both the Ag NP size distribution (20 to 100 nm Ag NPs) and the concentration of dissolved silver ions (Ag+ up to 7.5 μg L−1) in mixtures using Poisson statistics to determine thresholds to identify the beginning and end of NP signal events. SP-ICP-MS with a microsecond time resolution data acquisition system (μsDAQ) and conventional pneumatic nebulization was used for the detection of Ag NPs in the presence of a significant concentration of ionic BG (107Ag+ up to 1 000 000 cps). In contrast to conventional three times standard deviation of the BG (3 × SDBG) decision criterion (normal distribution), our NP ion cloud extraction mechanism from the μsDAQ is based on setting thresholds to determine the beginning and the end of an ion cloud using Poisson statistics, which is suitable for the low count data. The algorithm was applied here for the flagging and detection of Ag NPs in the presence of Ag+. Critical level (false positive probability was set to 5%) and detection limit (false positive and false negative probabilities were set to 5%) based on Poisson distributions were implemented to determine the thresholds. A range of different sets of NP ion cloud extraction conditions were tested to verify the calculated thresholds and to obtain optimal extraction conditions at different BGs (Ag+ concentration). The method can be universally applied for the detection of different elements with SP-ICP-MS.


  • Separation of Silver Nanoparticles with Different Coatings by Capillary Electrophoresis Coupled to ICP-MS in Single Particle Mode

    by Darya Mozhayeva, Carsten Engelhard

    The possibility of separating mixtures of Ag nanoparticles (NPs) with similar sizes but different surface coatings using capillary electrophoresis coupled to single particle inductively coupled mass-spectrometry (CE-SP-ICP-MS) was investigated. In two-component mixtures, it was possible to separate 40 nm sized polyvinylpirrolidone (PVP)- and citrate-coated NPs, 40 nm sized polyethylene glycol (PEG)- and citrate-coated NPs, and 60 nm sized PVP- and citrate-coated NPs. The separation of a more complex mixture containing NPs with the different coatings and sizes was successful, and each component, namely, 20, 40, and 60 nm sized citrate-coated and 40 and 60 nm sized PVP-coated NPs, could be distinguished. The theoretically expected migration order was confirmed by experimental results with selected Ag NPs. On the basis of the experimental observations, a separation mechanism that considers the effect of stable vs displaceable coatings during NP migration in CE is suggested. The ICP-MS was equipped with a prototype data acquisition system (μsDAQ) that provided 5 μs time resolution.


  • Implementation of Online Preconcentration and Microsecond Time Resolution to Capillary Electrophoresis Single Particle Inductively Coupled Plasma Mass Spectrometry (CE-SP-ICP-MS) and Its Application in Silver Nanoparticle Analysis

    by Darya Mozhayeva, Ingo Strenge, Carsten Engelhard

    Capillary electrophoresis (CE) coupled to single particle inductively coupled plasma mass-spectrometry (SP-ICP-MS) was used for the first time with a prototype data acquisition (μsDAQ) system that features 5 μs time resolution (100% duty cycle) to separate and quantify mixtures of silver nanoparticles (Ag NPs). Additionally, an online preconcentration technique, reversed electrode polarity stacking mode (REPSM), was applied for Ag NPs analysis with CE-SP-ICP-MS for the first time. After optimization, best results were achieved using a injection time of 110 s and a constant pressure of 50 mbar in hydrodynamic injection mode. It was possible to detect 14.3 ± 1.5× more 20 nm sized, 21.0 ± 4.2× more 40 nm sized, and 27.7 ± 4.9× more 60 nm sized Ag NPs compared to the standard injection time of only 3 s. The effect of applied voltage on the NPs separation was studied, and a CE separation at 20 kV was found to be optimal for the present setup. The capability of CE-SP-ICP-MS for quantification of particle number concentration was investigated, and detection limits in the submicrogram-per-liter range were achieved. The possibility to separate 20, 40, and 60 nm sized Ag NPs simultaneously present in a mixture was demonstrated over a broad concentration range.