Arun Kumar Singh
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Arun Kumar Singh has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Nitu Rani
R&D, Tata Steel Limited
9 shared publications G. Jha
Research and Development Division, Tata Steel, Jamshedpur-831001, India
4 shared publicationsN. Bandyopadhyay
TATA Steel Limited
3 shared publicationsAnkita Chauhan
National Institute of Technology
2 shared publicationsRishabh
2 shared publicationsS. Chakrabarti
2 shared publications
Latest Publications
- 20 April 2026
- Published by Taylor & Francis in Transactions of the IMF
- Vol. 104 (3) , 144-153
Poly(urea-formaldehyde) microcapsules with linseed oil: size reduction and performance optimisation for protective coatings on galvanised steel
- 20 April 2026
- Published by Taylor & Francis in Transactions of the IMF
- Vol. 104 (3) , 144-153
Poly(urea-formaldehyde) microcapsules with linseed oil: size reduction and performance optimisation for protective coatings on galvanised steel
- 16 February 2024
- Published by Taylor & Francis in Transactions of the IMF
- Vol. 102 (2) , 67-76
Self-healing properties of microencapsulated linseed oil-poly(urea formaldehyde) additives embedded polyester coating on Galvalume steel sheet
- 16 February 2024
- Published by Taylor & Francis in Transactions of the IMF
- Vol. 102 (2) , 67-76
Self-healing properties of microencapsulated linseed oil-poly(urea formaldehyde) additives embedded polyester coating on Galvalume steel sheet
- 4 May 2022
- Published by SAGE Publications in Surface Engineering
- Vol. 38 (5) , 499-506
Electrolytic cleaning study of cold rolled steel using scanning Kelvin probe
Oils and iron fines deposit on carbon steel during cold rolling and are removed by an electrolytic cleaning line (ECL). Sometimes localized contamination is observed on the ECL samples. No reliable tests are available for on-line measurement and the off-line tests demand samples with a large surface area. SKP addresses this issue effectively. SKP shows ∼390 mV potential difference between the clean and the uncleaned surface, with the cleaned surface potential being more positive. This indicates that the oil on the steel acts as a Lewis base, whereas the steel surface acts as a Lewis acid. Hence, the potential of the sample increases after cleaning. FTIR confirmed the absence of oil peaks on the cleaned samples. Deposition of an optimum thickness of the silicate layer is another important aspect of the ECL. It was measured by AES which displayed 2.3 nm of the silicate layer deposited on the cleaned steel surface.
- 4 May 2022
- Published by SAGE Publications in Surface Engineering
- Vol. 38 (5) , 499-506
Electrolytic cleaning study of cold rolled steel using scanning Kelvin probe
Oils and iron fines deposit on carbon steel during cold rolling and are removed by an electrolytic cleaning line (ECL). Sometimes localized contamination is observed on the ECL samples. No reliable tests are available for on-line measurement and the off-line tests demand samples with a large surface area. SKP addresses this issue effectively. SKP shows ∼390 mV potential difference between the clean and the uncleaned surface, with the cleaned surface potential being more positive. This indicates that the oil on the steel acts as a Lewis base, whereas the steel surface acts as a Lewis acid. Hence, the potential of the sample increases after cleaning. FTIR confirmed the absence of oil peaks on the cleaned samples. Deposition of an optimum thickness of the silicate layer is another important aspect of the ECL. It was measured by AES which displayed 2.3 nm of the silicate layer deposited on the cleaned steel surface.
- 4 April 2019
- Published by Wiley in Materials and Corrosion
- Vol. 70 (7) , 1162-1170
Scanning Kelvin probe study of steel/oil interfaces for corrosion evaluation
Rust preventive oil (RPO) provides temporary protection to steel during storage and transit. Premature failure occurs as surface defects due to inefficient RPO quality. Conventional corrosion tests like salt spray and cyclic corrosion provide minimum information about corrosion mechanism. We applied separately three RPO, named here as A–C, on bearing steels and their corrosion performance was examined by scanning Kelvin probe (SKP). The corrosion potential of samples lowered after oil application. It seems that oil film delayed oxygen reduction reaction. Later, oiled samples were exposed in salt spray test (SST) and again examined by SKP at different time interval. The SKP result showed that oiled sample A corrosion potential increased during SST exposure. Oil A might develop passivity on steel surface. It is also supported by least red rust formed on oiled sample A in SST. Fourier transform infrared spectroscopy, inductively coupled plasma and chemical analysis of oils were performed to interpret the SKP outcome. Oil A possesses low oxidation peak, low total acid number, and high total base number that signify higher corrosion resistant. Finally, SKP findings are in‐line with the conventional corrosion tests‐salt spray and condensation water tests.
- 4 April 2019
- Published by Wiley in Materials and Corrosion
- Vol. 70 (7) , 1162-1170
Scanning Kelvin probe study of steel/oil interfaces for corrosion evaluation
Rust preventive oil (RPO) provides temporary protection to steel during storage and transit. Premature failure occurs as surface defects due to inefficient RPO quality. Conventional corrosion tests like salt spray and cyclic corrosion provide minimum information about corrosion mechanism. We applied separately three RPO, named here as A–C, on bearing steels and their corrosion performance was examined by scanning Kelvin probe (SKP). The corrosion potential of samples lowered after oil application. It seems that oil film delayed oxygen reduction reaction. Later, oiled samples were exposed in salt spray test (SST) and again examined by SKP at different time interval. The SKP result showed that oiled sample A corrosion potential increased during SST exposure. Oil A might develop passivity on steel surface. It is also supported by least red rust formed on oiled sample A in SST. Fourier transform infrared spectroscopy, inductively coupled plasma and chemical analysis of oils were performed to interpret the SKP outcome. Oil A possesses low oxidation peak, low total acid number, and high total base number that signify higher corrosion resistant. Finally, SKP findings are in‐line with the conventional corrosion tests‐salt spray and condensation water tests.
- 4 May 2017
- Published by Taylor & Francis in Transactions of the IMF
- Vol. 95 (3) , 165-172
Preparation and characterisation of acrylic–polyurethane-based waterborne anticorrosion coating on galvanised steel
Four water-based organic composite coating solutions were prepared and applied on galvanised sheet samples producing a transparent film of about 5-µm thickness. Their corrosion performances were examined by Tafel polarisation, EIS, salt spray and cyclic corrosion tests. The primary coating formulation contained an acrylic emulsion and polyurethane dispersion mixture together with additives. The corrosion resistance properties of the primary formulation were enhanced by adding nano-ZnO particles, and further improved by adding corrosion inhibitors such as zinc phosphate and sodium phosphate. The final formulation on galvanised samples showed 720 h of salt spray resistance and 90 cycles of cyclic corrosion resistance, SAE J2334. The Tafel and EIS studies indicate that the coating possesses barrier protection properties. The electrolyte penetrates through the coating within 24 h but progress of corrosion depends upon the coating adhesion and its compactness, that is improved significantly by adding nano-ZnO and corrosion inhibitor to the coating formulation.
- 4 May 2017
- Published by Taylor & Francis in Transactions of the IMF
- Vol. 95 (3) , 165-172
Preparation and characterisation of acrylic–polyurethane-based waterborne anticorrosion coating on galvanised steel
Four water-based organic composite coating solutions were prepared and applied on galvanised sheet samples producing a transparent film of about 5-µm thickness. Their corrosion performances were examined by Tafel polarisation, EIS, salt spray and cyclic corrosion tests. The primary coating formulation contained an acrylic emulsion and polyurethane dispersion mixture together with additives. The corrosion resistance properties of the primary formulation were enhanced by adding nano-ZnO particles, and further improved by adding corrosion inhibitors such as zinc phosphate and sodium phosphate. The final formulation on galvanised samples showed 720 h of salt spray resistance and 90 cycles of cyclic corrosion resistance, SAE J2334. The Tafel and EIS studies indicate that the coating possesses barrier protection properties. The electrolyte penetrates through the coating within 24 h but progress of corrosion depends upon the coating adhesion and its compactness, that is improved significantly by adding nano-ZnO and corrosion inhibitor to the coating formulation.
- Open Access
- 1 January 2016
- Published by Iron and Steel Institute of Japan in ISIJ International
- Vol. 56 (8) , 1470-1479
Optimized Cr Concentration in Reinforcement Steel for High Corrosion Resistance in Simulated Pore Solution by Electrochemical and Cyclic Corrosion Tests
Nine samples of low-carbon steel were prepared by varying composition of Cr and Mn. The weight% of Cr and Mn in samples are 0.2Cr, 0.5Cr and 5Cr, and 0.5Mn, 1.0Mn and 1.5Mn respectively. The electrochemical tests such as corrosion potential, EIS, Linear polarization and Cyclic polarization were conducted on samples in simulated pore solution with and without the presence of 3.5% NaCl. Separately, samples were exposed to wet-dry corrosion test and their corrosion products were examined by XRD and FTIR. Further, oxidised surface was studied by SEM/EDS. The samples show passive behaviour in chloride free pore solution but passivity breaks after chloride addition. Even, 5Cr containing steels could not hold passive characteristic in chloride medium. In wet-dry corrosion test, 5Cr containing steels develop loose and voluminous corrosion products which is highly detrimental for rebar application. On the contrary, the lower Cr containing steels, 0.2Cr and 0.5Cr, produce thin and adherent rust in wetdry corrosion test. In electrochemical test, these steel samples too transfer from passive to active state after chloride ion addition in pore solution but their behaviour is superior. More particularly, two steel chemistry 0.2Cr, 0.5Mn and 0.5Cr, 1.5Mn show a sign of repassivation and pitting resistance respectively.
- 1 January 2016
- Published by Iron and Steel Institute of Japan in ISIJ International
- Vol. 56 (8) , 1470-1479
Open AccessOptimized Cr Concentration in Reinforcement Steel for High Corrosion Resistance in Simulated Pore Solution by Electrochemical and Cyclic Corrosion Tests
Nine samples of low-carbon steel were prepared by varying composition of Cr and Mn. The weight% of Cr and Mn in samples are 0.2Cr, 0.5Cr and 5Cr, and 0.5Mn, 1.0Mn and 1.5Mn respectively. The electrochemical tests such as corrosion potential, EIS, Linear polarization and Cyclic polarization were conducted on samples in simulated pore solution with and without the presence of 3.5% NaCl. Separately, samples were exposed to wet-dry corrosion test and their corrosion products were examined by XRD and FTIR. Further, oxidised surface was studied by SEM/EDS. The samples show passive behaviour in chloride free pore solution but passivity breaks after chloride addition. Even, 5Cr containing steels could not hold passive characteristic in chloride medium. In wet-dry corrosion test, 5Cr containing steels develop loose and voluminous corrosion products which is highly detrimental for rebar application. On the contrary, the lower Cr containing steels, 0.2Cr and 0.5Cr, produce thin and adherent rust in wetdry corrosion test. In electrochemical test, these steel samples too transfer from passive to active state after chloride ion addition in pore solution but their behaviour is superior. More particularly, two steel chemistry 0.2Cr, 0.5Mn and 0.5Cr, 1.5Mn show a sign of repassivation and pitting resistance respectively.
- 19 December 2013
- Published by Taylor & Francis in Transactions of the IMF
- Vol. 92 (3) , 153-160
Study of role of phosphate coating properties on electrophoretic paint performance by EIS and simulated corrosion tests
- 19 December 2013
- Published by Taylor & Francis in Transactions of the IMF
- Vol. 92 (3) , 153-160
Study of role of phosphate coating properties on electrophoretic paint performance by EIS and simulated corrosion tests
- 15 June 2013
- Published by Science Alert in International Journal of Agricultural Research
- Vol. 8 (3) , 137-148
Stability Analysis of Flowering and Yield Traits to High Temperature Stress Adopting Different Planting Dates in Rice (O. sativa L.)
- 15 June 2013
- Published by Science Alert in International Journal of Agricultural Research
- Vol. 8 (3) , 137-148
Stability Analysis of Flowering and Yield Traits to High Temperature Stress Adopting Different Planting Dates in Rice (O. sativa L.)
- 6 March 2012
- Published by Springer Nature in Journal of Coatings Technology and Research
- Vol. 9 (5) , 629-636
Optimization of phosphate coating properties on steel sheet for superior paint performance
- 6 March 2012
- Published by Springer Nature in Journal of Coatings Technology and Research
- Vol. 9 (5) , 629-636
Optimization of phosphate coating properties on steel sheet for superior paint performance
- 1 April 2006
- Published by Elsevier in Surface and Coatings Technology
- Vol. 200 (14-15) , 4312-4319
Corrosion behaviour of galvannealed steel sheet
- 1 April 2006
- Published by Elsevier in Surface and Coatings Technology
- Vol. 200 (14-15) , 4312-4319
Corrosion behaviour of galvannealed steel sheet