CHCharmayne Mary Lee Hughes

Charmayne Mary Lee Hughes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Charmayne Mary Lee Hughes has a total of 43 co-authors. Here are the top co-authors by number of shared publications:

  • Moges Baye

    Department of Physiotherapy, University of Gondar, Gondar, Ethiopia

    3 shared publications
  • Xiaorong Zhang

    NeuroTech Lab, Health Equity Institute, San Francisco State University, San Francisco, CA, United States

    3 shared publications
  • Yan Zhang

    Age-Appropriate Human-Machine Systems, Institute of Psychology and Ergonomics, Technische Universität Berlin

    3 shared publications
  • Alexander Louie

    School of Engineering, San Francisco State University, San Francisco, CA, United States

    2 shared publications
  • Ali Pourhossein

    Age-Appropriate Human-Machine Systems, Institute of Psychology and Ergonomics, Technische Universität Berlin, 10623 Berlin, Germany

    2 shared publications
  • Amy Hintze

    Health Equity Institute San Francisco State University San Francisco, CA United States

    2 shared publications

Latest Publications

  • Open Access

    Design and Experimental Validation of a Synchronized Multi-Rate Wireless Sensor Network for Multimodal Physiological and Biomechanical Data Acquisition

    by Ali Pourhossein, Charmayne M. L. Hughes

    Reliable multimodal measurement requires coordinated acquisition of physiological and biomechanical signals operating at different sampling rates. A six-node wireless architecture was developed to support seven data streams: three surface electromyography (sEMG) signals (2 kHz each), photoplethysmography (PPG, 400 Hz configured), inertial measurements (416 Hz configured), and independent pinch- and grip-force streams (nominal 80-SPS HX711 mode; measured at 85.1 and 85.9 samples/s, respectively). An ESP32-S3 gateway uses a single ESP-NOW network for sensor-data delivery and continuous per-node clock compensation while preserving raw measurements, sample-level timing metadata, and end-to-end integrity diagnostics. Across three independent 30-min full-system recordings, pooled packet delivery and sample continuity were 99.987% and 99.988%, respectively. External common-input validation between two independent sEMG nodes yielded a drift-compensated timing mean absolute error of 0.0754 ms across 897 accepted events. A separate six-node GPIO reference-pulse test yielded a node-clock alignment mean absolute error of 0.3123 ms across 5319 matched events with 99.49% of events below 1 ms. Network-load and indoor distance tests further characterized communication robustness. These results demonstrate the feasibility and reliability of a unified wireless architecture that integrates heterogeneous multi-rate sensing, continuous clock-drift compensation, preservation of original sensor measurements, and comprehensive data-integrity monitoring for synchronized physiological and biomechanical data acquisition.

  • Open Access

    Comparative evaluation of deep learning models for three-class frailty assessment using gait metrics

    by Charmayne Mary Lee Hughes, Yan Zhang

    Background: Frailty assessment in older adults typically relies on subjective clinical tools that are time-consuming and require trained personnel, limiting their use in routine or large-scale screening. Wearable sensor-based gait analysis offers a promising objective alternative; however, comprehensive evaluations of deep learning models for multi-class frailty classification using structured gait metrics remain limited. Methods: This study evaluates multiple deep learning architectures for three-class frailty classification using structured gait features derived from a single wearable inertial measurement unit (IMU). Four architectures (Transformer, ShapeFormer, InceptionTime, and LSTM-CNN) were evaluated using the publicly available GSTRIDE dataset, comprising 163 older adults (non-frail: n = 65, pre-frail: n = 77, frail: n = 21). Eleven clinically interpretable stride-level gait variables, extracted from a single IMU, were used as model input. A 10-fold participant-level cross-validation scheme, matching the default configuration of the original implementation (cv_seed = 1), was applied to ensure robust performance estimation and prevent data leakage. Results: The four architectures yielded comparable mean accuracy under a unified protocol (ShapeFormer 73.1% ± 10.6%, Transformer 72.6% ± 6.0%, InceptionTime 70.5% ± 9.5%, LSTM-CNN 65.9% ± 9.8%). A Friedman omnibus test on the per-fold scores did not reject the null of equal performance (borderline on accuracy and macro-F1 ( p = 0.050 and 0.056 respectively), with no significant difference for macro-AUC [ p = 0.840]), indicating that the apparent ranking is within sampling variability. Performance was higher for non-frail and pre-frail individuals, while classification of frail individuals remained challenging across all models. Conclusion: Multi-class frailty classification using structured gait metrics from a single wearable sensor is feasible, though performance varies across models and frailty classes. Model stability and sensitivity to specific classes represent important trade-offs. Significance: These findings support the development of scalable, objective approaches to frailty assessment and underscore the importance of selecting models based on clinical priorities.

  • Open Access

    Bursting the bubble: data leakage and inflated deep learning accuracy in multivariate time-series frailty classification

    by Charmayne Mary Lee Hughes, Yan Zhang

    Background: Accurate prediction of frailty in older adults is crucial for preventing adverse outcomes, yet distinguishing frail, pre-frail, and non-frail states remains challenging. A recent study applied InceptionTime to the GSTRIDE dataset and reported near-perfect multi-class frailty prediction (>98% accuracy), exceeding values typically observed in comparable studies. Methods: We conducted a methodological re-evaluation and replication of this pipeline to assess the robustness of reported performance. Corrections included subject-wise data partitioning, feature scaling within training folds, and non-overlapping sliding time windows applied separately to each subset to prevent potential leakage. Results: Reimplementation of the original pipeline reproduced the previously reported high accuracy. After applying the corrected framework, overall recall and precision decreased (50.9 and 52.3%, respectively), providing a more conservative, data-specific estimate of model generalizability. Per-class analysis indicated reductions across all categories, with Frail-class recall dropping to 21.4%, highlighting the particular challenge of identifying high-risk individuals. Conclusion: The findings suggest that methodological factors, such as data leakage, likely contributed to the previously reported high performance. Under rigorous controls, frailty prediction is challenging, particularly for the frail class, underscoring the need for careful evaluation of model generalizability. Significance: This study illustrates the importance of transparent, methodologically sound pipelines in clinical AI research. By providing a reproducible framework for frailty prediction, we aim to support future studies in obtaining realistic performance estimates and developing clinically meaningful models.


  • Open Access

    Development and Bench-to-Human Feasibility Evaluation of a Wireless Pinch-and-Grip Dynamometer

    by Ali Pourhossein, Mohamed Mehdi Ouerghi, Elisabeth Kuborn, Doguhan Tasdemir, Viktor Warwas, Charmayne Mary Lee Hughes


  • Open Access

    Understanding Intimate Partner Violence Through Police Crime Data: Descriptive and Temporal Insights

    by Charmayne Mary Lee Hughes

    Police crime reports are a critical but often underutilized source of information for understanding intimate partner violence (IPV). They provide systematic, population-level data on when, where, and how IPV incidents occur, complementing surveys and clinical studies. This study provides a descriptive analysis of IPV crime reports in Los Angeles (January 2020–December 2023) and models temporal trends using Seasonal Autoregressive Integrated Moving Average (SARIMA). Results showed that a total of 74,776 IPV-related incidents were reported to the LAPD in the four-year period, averaging 51.22 incidents per day (SD = 10.84). Most incidents occurred in residential settings (71.9%), followed by public spaces (18.2%) and transportation settings (6.5%). Females accounted for the majority of incidents (77.35%) compared to males (22.65%), and Physical IPV was the most frequently reported subtype (77.0%). Of these Physical IPV reports, most incidents did not involve a weapon (83.82%), while the use of firearms, bladed weapons, blunt objects, and improvised implements was relatively uncommon. Temporal modeling using SARIMA indicated that month-to-month variation was dominated by stable seasonal and autoregressive dynamics, with no evidence of a distinct pandemic-specific shift in call volume. By integrating descriptive and temporal analyses, the study offers actionable insights for public health, law enforcement, and community organizations working to prevent and respond to IPV.


  • Open Access

    A comparative analysis of binary and multi-class classification machine learning algorithms to detect current frailty status using the English longitudinal study of ageing (ELSA)

    by Charmayne Mary Lee Hughes, Yan Zhang, Ali Pourhossein, Terezia Jurasova

    Background: Physical frailty is a pressing public health issue that significantly increases the risk of disability, hospitalization, and mortality. Early and accurate detection of frailty is essential for timely intervention, reducing its widespread impact on healthcare systems, social support networks, and economic stability.Objective: This study aimed to classify frailty status into binary (frail vs. non-frail) and multi-class (frail vs. pre-frail vs. non-frail) categories. The goal was to detect and classify frailty status at a specific point in time. Model development and internal validation were conducted using data from wave 8 of the English Longitudinal Study of Ageing (ELSA), with external validation using wave 6 data to assess model generalizability.Methods: Nine classification algorithms, including Logistic Regression, Random Forest, K-nearest Neighbor, Gradient Boosting, AdaBoost, XGBoost, LightGBM, CatBoost, and Multi-Layer Perceptron, were evaluated and their performance compared.Results: CatBoost demonstrated the best overall performance in binary classification, achieving high recall (0.951), balanced accuracy (0.928), and the lowest Brier score (0.049) on the internal validation set, and maintaining strong performance externally with a recall of 0.950, balanced accuracy of 0.913, and F1-score of 0.951. Multi-class classification was more challenging, with Gradient Boosting emerging as the top model, achieving the highest recall (0.666) and precision (0.663) on the external validation set, with a strong F1-score (0.664) and reasonable calibration (Brier Score = 0.223).Conclusion: Machine learning algorithms show promise for the detection of current frailty status, particularly in binary classification. However, distinguishing between frailty subcategories remains challenging, highlighting the need for improved models and feature selection strategies to enhance multi-class classification accuracy.


  • Open Access

    The detection and prediction of surgical site infections using multi-modal sensors and machine learning: Results in an animal model

    by Charmayne Mary Lee Hughes, Andrew Jeffers, Arun Sethuraman, Michael Klum, Milly Tan, Valerie Tan

    Introduction: Surgical Site Infection (SSI) is a common healthcare-associated infection that imposes a considerable clinical and economic burden on healthcare systems. Advances in wearable sensors and digital technologies have unlocked the potential for the early detection and diagnosis of SSI, which can help reduce this healthcare burden and lower SSI-associated mortality rates.Methods: In this study, we evaluated the ability of a multi-modal bio-signal system to predict current and developing superficial incisional infection in a porcine model infected with Methicillin Susceptible Staphylococcus Aureus (MSSA) using a bagged, stacked, and balanced ensemble logistic regression machine learning model.Results: Results demonstrated that the expression levels of individual biomarkers (i.e., peri-wound tissue oxygen saturation, temperature, and bioimpedance) differed between non-infected and infected wounds across the study period, with cross-correlation analysis indicating that a change in bio-signal expression occurred 24 to 31 hours before this change was reflected by clinical wound scoring methods employed by trained veterinarians. Moreover, the multi-modal ensemble model indicated acceptable discriminability to detect the presence of a current superficial incisional SSI (AUC = 0.77), to predict an SSI 24 hours in advance of veterinarian-based SSI diagnosis (AUC = 0.80), and to predict an SSI 48 hours in advance of veterinarian-based SSI diagnosis (AUC = 0.74).Discussion: In sum, the results of the current study indicate that non-invasive multi-modal sensor and signal analysis systems have the potential to detect and predict superficial incisional SSIs in porcine subjects under experimental conditions.


  • Open Access

    Accuracy and Validity of a Single Inertial Measurement Unit-Based System to Determine Upper Limb Kinematics for Medically Underserved Populations

    by Charmayne Mary Lee Hughes, Bao Tran, Amir Modan, Xiaorong Zhang

    Stroke is one of the leading causes of death and disability worldwide, with a disproportionate burden represented by low- and middle-income countries (LMICs). To improve post-stroke outcomes in LMICs, researchers have sought to leverage emerging technologies that overcome traditional barriers associated with stroke management. One such technology, inertial measurement units (IMUs), exhibit great potential as a low-cost, portable means to evaluate and monitor patient progress during decentralized rehabilitation protocols. As such, the aim of the present study was to determine the ability of a low-cost single IMU sensor-based wearable system (named the T’ena sensor) to reliably and accurately assess movement quality and efficiency in physically and neurologically healthy adults. Upper limb movement kinematics measured by the T’ena sensor were compared to the gold standard reference system during three functional tasks, and root mean square errors, Pearson’s correlation coefficients, intraclass correlation coefficients, and the Bland Altman method were used to compare kinematic variables of interest between the two systems for absolute accuracy and equivalency. The T’ena sensor and the gold standard reference system were significantly correlated for all tasks and measures (rrange = 0.648—0.947), although less so for the Finger to Nose task (rrange = 0.648—0.894). Results demonstrate that single IMU systems are a valid, reliable, and objective method by which to measure movement kinematics during functional tasks. Context-appropriate enabling technologies specifically designed to address barriers to quality health services in LMICs can accelerate progress towards the United Nations Sustainable Development Goal 3.


  • Open Access

    The mPOWERED Electronic Learning System for Intimate Partner Violence Education: Mixed Methods Usability Study

    by Charmayne Hughes, Elaine A Musselman, Lilia Walsh, Tatiana Mariscal, Sam Warner, Amy Hintze, Neela Rashidi, Chloe Gordon-Murer, Tiana Tanha, Fahrial Licudo, et al.

    Background: Nurse practitioners are a common resource for victims of intimate partner violence (IPV) presenting to health care settings. However, they often have inadequate knowledge about IPV and lack self-efficacy and confidence to be able to screen for IPV and communicate effectively with patients. Objective: The aim of this study was to develop and test the usability of a blended learning system aimed at educating nurse practitioner students on topics related to IPV (ie, the mPOWERED system [Health Equity Institute]). Methods: Development of the mPOWERED system involved usability testing with 7 nurse educators (NEs) and 18 nurse practitioner students. Users were asked to complete usability testing using a speak-aloud procedure and then complete a satisfaction and usability questionnaire. Results: Overall, the mPOWERED system was deemed to have high usability and was positively evaluated by both NEs and nurse practitioner students. Respondents provided critical feedback that will be used to improve the system. Conclusions: By including target end users in the design and evaluation of the mPOWERED system, we have developed a blended IPV learning system that can easily be integrated into health care education. Larger-scale evaluation of the pedagogical impact of this system is underway.


  • Open Access

    Quantitative Assessment of Upper Limb Motor Function in Ethiopian Acquired Brain Injured Patients Using a Low-Cost Wearable Sensor

    by Charmayne M. L. Hughes, Moges Baye, Chloe Gordon-Murer, Alexander Louie, Selena Sun, Gashaw Jember Belay, Xiaorong Zhang

    Acquired brain injuries place a significant burden on sub-Saharan African rehabilitation clinicians and health care facilities. While wearable sensors have the potential to alleviate these issues, many are beyond the financial capabilities of the majority of African persons and clinics. To bridge this gap, we have developed a low-cost wrist-worn sensor (the outREACH sensor) capable of accurately measuring upper limb movement kinematics. In this study we evaluated the extent to which the outREACH sensor is sensitive to the hand performing the task (unimpaired, impaired) and level of impairment (mild, moderate) in 14 Ethiopian persons with acquired brain injury (mean age = 51.6 ± 12.2 years, 1 female, 13 male). Participants performed an object manipulation task with both the impaired and the unimpaired limb, and reaching performance was measured using standard kinematic measures (i.e., movement time, spectral arc length, peak velocity, peak acceleration, mean velocity, mean acceleration). Overall, movements were smoother and faster when performed by the patient's unimpaired limb. In contrast, maximum velocity did not differ between the two limbs. Moreover, the outREACH sensor was sensitive to differences in performance-based upper limb impairment. Fugl-Meyer assessment for upper extremity scores were significantly correlated with movement time, spectral arc length, and peak velocity. Upper limb movement kinematics can be accurately measured using the outREACH sensor. The outREACH sensor can be a valuable addition to standardized clinical measures that provides rehabilitation clinicians with information regarding initial upper limb impairment level and changes in function across the rehabilitation lifespan.