ZAZakaria Aboulbanine

Zakaria Aboulbanine

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zakaria Aboulbanine has a total of 60 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    First high peak and average power THz SASE FEL in operation

    by Mikhail Krasilnikov, Zakaria Aboulbanine, Gowri Adhikari, Namra Aftab, Aida Asoyan, Prach Boonpornprasert, Hakob Davtyan, Georgi Georgiev, James Good, Anna Grebinyk, et al.

    Advanced experiments using THz pump and X-ray probe pulses at modern free-electron lasers (FELs) like the European X-ray FEL require a frequency-tunable (from 0.1 THz to 30 THz), high-power (> 10 microjoule), narrow-band (~ 1–2%) THz source maintaining the repetition rate and pulse structure of the X-ray pulses. This paper reports the first results from a THz source, that is based on a self-amplified spontaneous emission (SASE) FEL operating with a central wavelength of 100 micrometers. The THz SASE FEL prototype is currently under development at the Photo Injector Test facility at DESY in Zeuthen (PITZ) and uses the same type of electron source as the European XFEL photo injector. The first proof-of-principle experiments were done at PITZ using an LCLS-I undulator to generate high-power, high-repetition-rate THz SASE FEL radiation. Electron bunches with a beam energy of ~ 17 MeV and a bunch charge of up to several nC are used to generate THz pulses with a pulse energy of several tens of microjoules. For example, for an electron beam with a charge of ~ 2.4 nC, 65 microjoules were measured at a central wavelength of 100 micrometers. These proof-of-principle experiments pave the way for a tunable, high-repetition-rate THz source providing pulses with energies in the millijoule range.


  • Impact of the anode tilt on photon emission spectrum and temperature rise in an x-ray tube

    by Hassan Ou Hadda, Mustapha Zerfaoui, Karim Bahhous, Zakaria Aboulbanine, Samir Didi, Abdeslem Rrhioua, Dikra Bakari

    In radiology, the photon fluence and the energy spectrum generated from an x-ray tube may depend on the anode tilt angle. In this contribution, a Monte Carlo investigation is performed to quantify this effect by modeling an x-ray tube based on published data Bujila R. et al (2020 Physica. Med. 75 44–54). The GATE simulation code is used for this purpose. The calculations have moreover confirmed this dependence; the tilt of the anode could be used to increase the photon fluence. The thermal analysis has shown that the hot spot size is dependent as well on the anode tilt angle. The thermal focus temperature (ΔT) decreases when the anode tilt angle increases. Finally, by moving the acquisition angle from 293°–337° to 248°–292° and changing the anode tilt angle from 8° to 28°, the photon fluence can be increased by 55%.


  • Open Access

    Analysis of photoinjector transverse phase space in action and phase coordinates

    by Houjun Qian, Mikhail Krasilnikov, Zakaria Aboulbanine, Gowri Adhikari, Namra Aftab, Prach Boonpornpras, Georgi Georgiev, James Good, Matthias Gross, Christian Koschitzki, et al.

    Photoinjectors are the main high brightness electron sources for x-ray free electron lasers (XFELs). Photoinjector emittance reduction is one of the key knobs for improving XFEL lasing, so precise emittance measurement is critical. It is well known that rms emittance is very sensitive to low intensity tails of particle distributions in the phase space, whose measurement depends on the signal to noise ratio and image processing procedures. Such sensitivities make the interpretations of beam transverse brightness challenging, leading to different emittance definitions to reduce the impact of tail particles. In this paper, transverse phase space is analyzed in action and phase coordinates for both analytical models and experiments, which gives a more intuitive way to calculate the beam core brightness.


  • Open Access

    Slice energy spread measurement in the low energy photoinjector

    by Houjun Qian, Mikhail Krasilnikov, Anusorn Lueangaramwong, Xiangkun Li, Osip Lishilin, Zakaria Aboulbanine, Gowri Adhikari, Namra Aftab, Prach Boonpornprasert, Georgi Georgiev, et al.

    Slice energy spread is one of the key parameters in free electron laser optimizations, but its accurate measurement is not straightforward. Two recent studies from high energy (>= 100 MeV) photoinjectors at SwissFEL and European x-ray free electron laser (XFEL) have reported much higher slice energy spread than expected at their XFEL working points (200-250 pC). In this paper, a new method for measuring slice energy spread at lower beam energy (similar to 20 MeV) is proposed and demonstrated at the PhotoInjector Test facility at DESY Zeuthen, and the results for 250 pC are much lower than those measured at high energy injectors.


  • Experimental validation of a linac head Geant4 model under a grid computing environment

    by Samir Didi, Karim Bahhous, Mustapha Zerfaoui, Zakaria Aboulbanine, Hassan Ouhadda, Abdellah Halimi

    Background and purpose . This work aims to present the strategy to simulate a clinical linear accelerator based on the geometry provided by the manufacturer and summarize the corresponding experimental validation. Simulations were performed with the Geant4 Monte Carlo code under a grid computing environment. The objective of this contribution is reproducing therapeutic dose distributions in a water phantom with an accuracy less than 2%. Materials and methods. A Geant4 Monte Carlo model of an Elekta Synergy linear accelerator has been established, the simulations were launched in a large grid computing platform. Dose distributions are calculated for a 6 MV photon beam with treatment fields ranging from 5 × 5 cm 2 to 20 × 20 cm 2 at a source—surface distance of 100 cm. Results. A high degree of agreement is achieved between the simulation results and the measured data, with dose differences of about 1.03% and 1.96% for the percentage depth dose curves and lateral dose profiles, respectively. This agreement is evaluated by the gamma index comparisons. Over 98% of the points for all simulations meet the restrictive acceptability criteria of 2%/2 mm. Conclusion. We have demonstrated the possibility to establish an accurate linac head Monte Carlo model for dose distribution simulations and quality assurance. Percentage depth dose curves and beam quality indices are in perfect agreement with the measured data with an accuracy of better than 2%.


  • A theoretical multileaf collimator model for fast Monte Carlo dose calculation of linac 6/10 MV photon beams

    by Zakaria Aboulbanine, Naïma El Khayati

    A complete linac photon beam Monte Carlo dose calculation, even on a fast computer, requires generally a substantial computation time. The existing approaches developed to improve the efficiency are mainly based on the use of variance reduction techniques, phase space sources or virtual source models. The collimation of the simulated photon beam, involving particle transport through the multileaf collimator, considerably increases the calculation time especially for intensity modulation radiation therapy, where multiple small and medium field shapes are taking place. In this paper an improvement of a previous model will aim to significantly enhance the calculation efficiency for fast intensity modulation computations mainly by the use of an analytical collimator. The linac photon beam and multileaf collimator model is controlled by several parameters, such as, the geometrical dimensions of the primary collimator, the flattening filter and the number of leaves of the linac’s collimator. The model uses only correlated energy spectra and particle fluence distributions derived from the International Atomic Energy Agency phase space files of Elekta Precise Varian TrueBeam.


  • Validation of a virtual source model of medical linac for Monte Carlo dose calculation using multi-threaded Geant4

    by Zakaria Aboulbanine, Naïma El Khayati

    The use of phase space in medical linear accelerator Monte Carlo (MC) simulations significantly improves the execution time and leads to results comparable to those obtained from full calculations. The classical representation of phase space stores directly the information of millions of particles, producing bulky files. This paper presents a virtual source model (VSM) based on a reconstruction algorithm, taking as input a compressed file of roughly 800 kb derived from phase space data freely available in the International Atomic Energy Agency (IAEA) database. This VSM includes two main components; primary and scattered particle sources, with a specific reconstruction method developed for each. Energy spectra and other relevant variables were extracted from IAEA phase space and stored in the input description data file for both sources. The VSM was validated for three photon beams: Elekta Precise 6 MV/10 MV and a Varian TrueBeam 6 MV. Extensive calculations in water and comparisons between dose distributions of the VSM and IAEA phase space were performed to estimate the VSM precision. The Geant4 MC toolkit in multi-threaded mode ( Geant4-[mt] ) was used for fast dose calculations and optimized memory use. Four field configurations were chosen for dose calculation validation to test field size and symmetry effects, , , and for squared fields, and for an asymmetric rectangular field. Good agreement in terms of formalism, for 3%/3 mm and 2%/3 mm criteria, for each evaluated radiation field and photon beam was obtained within a computation time of 60 h on a single WorkStation for a 3 mm voxel matrix. Analyzing the VSM’s precision in high dose gradient regions, using the distance to agreement concept (DTA), showed also satisfactory results. In all investigated cases, the mean DTA was less than 1 mm in build-up and penumbra regions. In regards to calculation efficiency, the event processing speed is six times faster using Geant4-[mt] compared to sequential Geant4 , when running the same simulation code for both. The developed VSM for 6 MV/10 MV beams widely used, is a general concept easy to adapt in order to reconstruct comparable beam qualities for various linac configurations, facilitating its integration for MC treatment planning purposes.


  • Open Access

    Numerical Study of Beam Dynamics in PITZ Bunch Compressor

    by Anusorn Lueangaramwong, Zakaria Aboulbanine, Gowri Adhikari, Namra Aftab, Prach Boonpornprasert, Natthawut Chaisueb, Georgi Georgiev, James Good, Matthias Groß, Christian Koschitzki, et al.

  • Open Access

    Matching of a Space-Charge Dominated Beam into the Undulator of the THz SASE FEL at PITZ

    by Xiangkun Li, Zakaria Aboulbanine, Gowri Adhikari, Namra Aftab, Zohrab Amirkhanyan, Prach Boonpornprasert, Maria Elena Castro Carballo, Natthawut Chaisueb, Georgi Georgiev, James Good, et al.