Kevin Land
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kevin Land has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
- Suzanne Smith
Council for Scientific and Industrial Research (CSIR)
10 shared publications - Jan Gerrit Korvink
Institute of Microstructure Technology Karlsruhe Institute of Technology Eggenstein‐Leopoldshafen Germany
6 shared publications Louis Fourie
5 shared publicationsMesuli B. Mbanjwa
4 shared publicationsHao Chen
Materials Science and Manufacturing, Council for Scientific and Industrial Research, Pretoria, South Africa
3 shared publications- Trudi-Heleen Joubert
Department of Electrical, Electronic and Computer Engineering, University of Pretoria, Pretoria 0002, South Africa
3 shared publications
Latest Publications
- Open Access
- 14 January 2022
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- Vol. 12 (1) , 153-164
Nickel contamination analysis at cost-effective silver printed paper-based electrodes based on carbon black dimethylglyoxime ink as electrode modifier
Electrochemical detection of metal cations at paper-based sensors has been suggested as an attractive alternative to current spectroscopic and chromatographic detection techniques due to the ease of fabrication, disposable nature, and low cost. Herein, a novel carbon black (CB), dimethylglyoxime (DMG) ink is designed as an electrode modifier in conjunction with 3-electrode inkjet-printed paper substrates for use in the adsorptive stripping voltammetric electroanalysis of nickel cations in water samples. The developed method provides a novel, low-cost, rapid, and portable adsorptive stripping detection approach towards metal analysis in the absence of the commonly used toxic metallic films. The study demonstrated a novel approach to nickel detection at paper-based sensors and builds on previous work in the field of paper-based metal analysis by limiting the use of toxic metal films. The device sensitivity is improved by increasing the active surface area, electron transfer kinetics, and catalytic effects associated with non-conductive dimethylglyoxime films through CB nanoparticles for the first time and confirmed by electroanalysis. The first use of the CB-DMG ink allows for the selective preconcentration of analyte at the electrode surface without the use of toxic Mercury or Bismuth metallic films. Compared to similarly reported paper-based sensors, improved limits of detection (48 µg L-1), selectivity, and intermetallic interferences were achieved. The method was applied to the detection of nickel in water samples well below World Health Organization (WHO) standards.
- 14 January 2022
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- Vol. 12 (1) , 153-164
Open AccessNickel contamination analysis at cost-effective silver printed paper-based electrodes based on carbon black dimethylglyoxime ink as electrode modifier
Electrochemical detection of metal cations at paper-based sensors has been suggested as an attractive alternative to current spectroscopic and chromatographic detection techniques due to the ease of fabrication, disposable nature, and low cost. Herein, a novel carbon black (CB), dimethylglyoxime (DMG) ink is designed as an electrode modifier in conjunction with 3-electrode inkjet-printed paper substrates for use in the adsorptive stripping voltammetric electroanalysis of nickel cations in water samples. The developed method provides a novel, low-cost, rapid, and portable adsorptive stripping detection approach towards metal analysis in the absence of the commonly used toxic metallic films. The study demonstrated a novel approach to nickel detection at paper-based sensors and builds on previous work in the field of paper-based metal analysis by limiting the use of toxic metal films. The device sensitivity is improved by increasing the active surface area, electron transfer kinetics, and catalytic effects associated with non-conductive dimethylglyoxime films through CB nanoparticles for the first time and confirmed by electroanalysis. The first use of the CB-DMG ink allows for the selective preconcentration of analyte at the electrode surface without the use of toxic Mercury or Bismuth metallic films. Compared to similarly reported paper-based sensors, improved limits of detection (48 µg L-1), selectivity, and intermetallic interferences were achieved. The method was applied to the detection of nickel in water samples well below World Health Organization (WHO) standards.
- 28 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 265-268
Emerging Technology Solutions Towards REASSURED Point-of-Need Diagnostics
The need for effective point-of-need health and environmental diagnostics in low and middle income countries (LMICs) is more crucial than ever. This work explores emerging criteria and technologies to address the limitations of current point-of-need solutions. Local developments in South Africa towards this goal are highlighted, utilizing additive manufacturing technologies which combine paper-based diagnostic and printed electronic platforms. Establishment of a pipeline, from undergraduate engineering students and laboratory infrastructure to industry partners using a decentralized manufacturing approach are also discussed as a map for developing novel, low-cost solutions for improving the quality of life of those who need it most.
- 28 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 265-268
Emerging Technology Solutions Towards REASSURED Point-of-Need Diagnostics
The need for effective point-of-need health and environmental diagnostics in low and middle income countries (LMICs) is more crucial than ever. This work explores emerging criteria and technologies to address the limitations of current point-of-need solutions. Local developments in South Africa towards this goal are highlighted, utilizing additive manufacturing technologies which combine paper-based diagnostic and printed electronic platforms. Establishment of a pipeline, from undergraduate engineering students and laboratory infrastructure to industry partners using a decentralized manufacturing approach are also discussed as a map for developing novel, low-cost solutions for improving the quality of life of those who need it most.
- 14 October 2020
- Published by Wiley in Electroanalysis
- Vol. 32 (12) , 3017-3031
Graphene‐AuNP Enhanced Inkjet‐printed Silver Nanoparticle Paper Electrodes for the Detection of Nickel(II)‐Dimethylglyoxime [Ni(dmgH2)] Complexes by Adsorptive Cathodic Stripping Voltammetry (AdCSV)
The development of low‐cost, disposable electrode materials has been at the forefront of sensor technology in recent decades. Paper, offers possibilities for multi‐functional, disposable and economically friendly sensing capabilities and has proved to be a suitable reagent storage and substrate material in paper‐based analytical devices (PADs). In this work, we report a simple inkjet printing procedure on photographic paper for the fabrication of single analyte electrochemical sensors. A three‐electrode system, consisting of a 3 mm diameter working electrode (WE), a counter electrode (CE) and a reference electrode (RE) were prepared by inkjet printing of silver conductive inks for comparison to common commercial screen printed electrode (SPE) brands. In a second step, carbon coating and modification of the working electrode surface with an electrochemically reduced graphene oxide, gold nanoparticle (ERGO‐AuNP) film, to improve electrode sensitivity and selectivity was employed. Improved electron‐transfer kinetics, increased active surface area and enhanced catalytic properties were achieved due to the ERGO‐AuNP layer inclusion. Electrical and topographical characterization of the printed layers was performed in the fabrication process. Printing of Ag−NP ink showed good resistivity (1.8–6.3 Ω) on photographic paper. The prepared printed paper‐based electrodes (PPE) offer a quantitative analysis of Ni(II), based on the accumulation of Ni(dmgH)2 complexes at the modified electrode surface by square‐wave adsorptive cathodic stripping voltammetry (SW‐AdCSV). This study offers the first investigation on the feasibility of adsorptive electrochemical sensing methods at porous cellulose paper‐based substrates. Instrumental parameters including deposition potential and deposition time were optimized for both electrochemical sensors. Improved sensitivities were achieved at the modified integrated electrodes over the unmodified derivate with a limit of detection (LOD) of 32.19 μg L−1 achieved for the ERGO‐AuNP−CC−Ag−PPE. This is well below the EPA and WHO standards of 0.1 mg L−1 or 0.1 ppm for Ni2+ in drinking water.
- 14 October 2020
- Published by Wiley in Electroanalysis
- Vol. 32 (12) , 3017-3031
Graphene‐AuNP Enhanced Inkjet‐printed Silver Nanoparticle Paper Electrodes for the Detection of Nickel(II)‐Dimethylglyoxime [Ni(dmgH2)] Complexes by Adsorptive Cathodic Stripping Voltammetry (AdCSV)
The development of low‐cost, disposable electrode materials has been at the forefront of sensor technology in recent decades. Paper, offers possibilities for multi‐functional, disposable and economically friendly sensing capabilities and has proved to be a suitable reagent storage and substrate material in paper‐based analytical devices (PADs). In this work, we report a simple inkjet printing procedure on photographic paper for the fabrication of single analyte electrochemical sensors. A three‐electrode system, consisting of a 3 mm diameter working electrode (WE), a counter electrode (CE) and a reference electrode (RE) were prepared by inkjet printing of silver conductive inks for comparison to common commercial screen printed electrode (SPE) brands. In a second step, carbon coating and modification of the working electrode surface with an electrochemically reduced graphene oxide, gold nanoparticle (ERGO‐AuNP) film, to improve electrode sensitivity and selectivity was employed. Improved electron‐transfer kinetics, increased active surface area and enhanced catalytic properties were achieved due to the ERGO‐AuNP layer inclusion. Electrical and topographical characterization of the printed layers was performed in the fabrication process. Printing of Ag−NP ink showed good resistivity (1.8–6.3 Ω) on photographic paper. The prepared printed paper‐based electrodes (PPE) offer a quantitative analysis of Ni(II), based on the accumulation of Ni(dmgH)2 complexes at the modified electrode surface by square‐wave adsorptive cathodic stripping voltammetry (SW‐AdCSV). This study offers the first investigation on the feasibility of adsorptive electrochemical sensing methods at porous cellulose paper‐based substrates. Instrumental parameters including deposition potential and deposition time were optimized for both electrochemical sensors. Improved sensitivities were achieved at the modified integrated electrodes over the unmodified derivate with a limit of detection (LOD) of 32.19 μg L−1 achieved for the ERGO‐AuNP−CC−Ag−PPE. This is well below the EPA and WHO standards of 0.1 mg L−1 or 0.1 ppm for Ni2+ in drinking water.
- Open Access
- 2 September 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 19 (19) , 3344-3353
Wireless colorimetric readout to enable resource-limited point-of-care
A low-cost, automated wireless result readout device for point-of-care diagnostics in resource-limited clinics in Southern Africa.
- 2 September 2019
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 19 (19) , 3344-3353
Open AccessWireless colorimetric readout to enable resource-limited point-of-care
A low-cost, automated wireless result readout device for point-of-care diagnostics in resource-limited clinics in Southern Africa.
- Top Cited Papers
- 13 December 2018
- Published by Springer Nature in Nature Microbiology
- Vol. 4 (1) , 46-54
REASSURED diagnostics to inform disease control strategies, strengthen health systems and improve patient outcomes
Lack of access to quality diagnostics remains a major contributor to health burden in resource-limited settings. It has been more than 10 years since ASSURED (affordable, sensitive, specific, user-friendly, rapid, equipment-free, delivered) was coined to describe the ideal test to meet the needs of the developing world. Since its initial publication, technological innovations have led to the development of diagnostics that address the ASSURED criteria, but challenges remain. From this perspective, we assess factors contributing to the success and failure of ASSURED diagnostics, lessons learnt in the implementation of ASSURED tests over the past decade, and highlight additional conditions that should be considered in addressing point-of-care needs. With rapid advances in digital technology and mobile health (m-health), future diagnostics should incorporate these elements to give us REASSURED diagnostic systems that can inform disease control strategies in real-time, strengthen the efficiency of health care systems and improve patient outcomes.
- 13 December 2018
- Published by Springer Nature in Nature Microbiology
- Vol. 4 (1) , 46-54
Top Cited PapersREASSURED diagnostics to inform disease control strategies, strengthen health systems and improve patient outcomes
Lack of access to quality diagnostics remains a major contributor to health burden in resource-limited settings. It has been more than 10 years since ASSURED (affordable, sensitive, specific, user-friendly, rapid, equipment-free, delivered) was coined to describe the ideal test to meet the needs of the developing world. Since its initial publication, technological innovations have led to the development of diagnostics that address the ASSURED criteria, but challenges remain. From this perspective, we assess factors contributing to the success and failure of ASSURED diagnostics, lessons learnt in the implementation of ASSURED tests over the past decade, and highlight additional conditions that should be considered in addressing point-of-care needs. With rapid advances in digital technology and mobile health (m-health), future diagnostics should incorporate these elements to give us REASSURED diagnostic systems that can inform disease control strategies in real-time, strengthen the efficiency of health care systems and improve patient outcomes.
- Open Access
- 3 October 2018
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 8 (59) , 34012-34034
The potential of paper-based diagnostics to meet the ASSURED criteria
A review of printed functionalities towards integrated paper-based diagnostics that fully meet the ASSURED principles.
- 3 October 2018
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 8 (59) , 34012-34034
Open AccessThe potential of paper-based diagnostics to meet the ASSURED criteria
A review of printed functionalities towards integrated paper-based diagnostics that fully meet the ASSURED principles.
- 1 June 2018
- Published by Elsevier in Process Biochemistry
- Vol. 69, 75-81
Production of self-immobilised enzyme microspheres using microfluidics
- 1 June 2018
- Published by Elsevier in Process Biochemistry
- Vol. 69, 75-81
Production of self-immobilised enzyme microspheres using microfluidics
- 1 September 2017
- Published by AIP Publishing in Biomicrofluidics
- Vol. 11 (5) , 054101
Novel functionalities of hybrid paper-polymer centrifugal devices for assay performance enhancement
The presented work demonstrates novel functionalities of hybrid paper-polymer centrifugal devices for assay performance enhancement that leverage the advantages of both paper-based and centrifugal microfluidic platforms. The fluid flow is manipulated by balancing the capillary force of paper inserts with the centrifugal force generated by disc rotation to enhance the signal of a colorimetric lateral flow immunoassay for pathogenic E. coli. Low-cost centrifugation for pre-concentration of bacteria was demonstrated by sample sedimentation at high rotational speeds before supernatant removal by a paper insert via capillary force after deceleration. The live bacteria capture efficiency of the device was similar to a commercial centrifuge. This pre-concentrated sample when combined with gold nanoparticle immunoconjugate probes resulted in a detection limit that is 10× lower than a non-concentrated sample for a lateral flow immunoassay. Signal enhancement was also demonstrated through rotational speed variation to prevent the flow for on-device incubation and to reduce the flow rate, thus increasing the sample residence time for the improved capture of gold nanoparticle-bacteria complexes in an integrated paper microfluidic assay. Finally, multiple sequential steps including sample pre-concentration, filtration, incubation, target capture by an integrated paper microfluidic assay, silver enhancement and quenching, and index matching were completed within a single device. The detection limit was 105 colony forming units per ml, a 100× improvement over a similar paper-based lateral flow assay. The techniques utilize the advantages of paper-based microfluidic devices, while facilitating additional functionalities with a centrifugal microfluidic platform for detection performance enhancement in a low-cost, automated platform amenable to point-of-care environments.
- 1 September 2017
- Published by AIP Publishing in Biomicrofluidics
- Vol. 11 (5) , 054101
Novel functionalities of hybrid paper-polymer centrifugal devices for assay performance enhancement
The presented work demonstrates novel functionalities of hybrid paper-polymer centrifugal devices for assay performance enhancement that leverage the advantages of both paper-based and centrifugal microfluidic platforms. The fluid flow is manipulated by balancing the capillary force of paper inserts with the centrifugal force generated by disc rotation to enhance the signal of a colorimetric lateral flow immunoassay for pathogenic E. coli. Low-cost centrifugation for pre-concentration of bacteria was demonstrated by sample sedimentation at high rotational speeds before supernatant removal by a paper insert via capillary force after deceleration. The live bacteria capture efficiency of the device was similar to a commercial centrifuge. This pre-concentrated sample when combined with gold nanoparticle immunoconjugate probes resulted in a detection limit that is 10× lower than a non-concentrated sample for a lateral flow immunoassay. Signal enhancement was also demonstrated through rotational speed variation to prevent the flow for on-device incubation and to reduce the flow rate, thus increasing the sample residence time for the improved capture of gold nanoparticle-bacteria complexes in an integrated paper microfluidic assay. Finally, multiple sequential steps including sample pre-concentration, filtration, incubation, target capture by an integrated paper microfluidic assay, silver enhancement and quenching, and index matching were completed within a single device. The detection limit was 105 colony forming units per ml, a 100× improvement over a similar paper-based lateral flow assay. The techniques utilize the advantages of paper-based microfluidic devices, while facilitating additional functionalities with a centrifugal microfluidic platform for detection performance enhancement in a low-cost, automated platform amenable to point-of-care environments.
- Open Access
- 29 January 2016
- Published by MDPI AG in Micromachines
- Vol. 7 (2) , 22
CD-Based Microfluidics for Primary Care in Extreme Point-of-Care Settings
We review the utility of centrifugal microfluidic technologies applied to point-of-care diagnosis in extremely under-resourced environments. The various challenges faced in these settings are showcased, using areas in India and Africa as examples. Measures for the ability of integrated devices to effectively address point-of-care challenges are highlighted, and centrifugal, often termed CD-based microfluidic technologies, technologies are presented as a promising platform to address these challenges. We describe the advantages of centrifugal liquid handling, as well as the ability of a standard CD player to perform a number of common laboratory tests, fulfilling the role of an integrated lab-on-a-CD. Innovative centrifugal approaches for point-of-care in extremely resource-poor settings are highlighted, including sensing and detection strategies, smart power sources and biomimetic inspiration for environmental control. The evolution of centrifugal microfluidics, along with examples of commercial and advanced prototype centrifugal microfluidic systems, is presented, illustrating the success of deployment at the point-of-care. A close fit of emerging centrifugal systems to address a critical panel of tests for under-resourced clinic settings, formulated by medical experts, is demonstrated. This emphasizes the potential of centrifugal microfluidic technologies to be applied effectively to extremely challenging point-of-care scenarios and in playing a role in improving primary care in resource-limited settings across the developing world.
- 29 January 2016
- Published by MDPI AG in Micromachines
- Vol. 7 (2) , 22
Open AccessCD-Based Microfluidics for Primary Care in Extreme Point-of-Care Settings
We review the utility of centrifugal microfluidic technologies applied to point-of-care diagnosis in extremely under-resourced environments. The various challenges faced in these settings are showcased, using areas in India and Africa as examples. Measures for the ability of integrated devices to effectively address point-of-care challenges are highlighted, and centrifugal, often termed CD-based microfluidic technologies, technologies are presented as a promising platform to address these challenges. We describe the advantages of centrifugal liquid handling, as well as the ability of a standard CD player to perform a number of common laboratory tests, fulfilling the role of an integrated lab-on-a-CD. Innovative centrifugal approaches for point-of-care in extremely resource-poor settings are highlighted, including sensing and detection strategies, smart power sources and biomimetic inspiration for environmental control. The evolution of centrifugal microfluidics, along with examples of commercial and advanced prototype centrifugal microfluidic systems, is presented, illustrating the success of deployment at the point-of-care. A close fit of emerging centrifugal systems to address a critical panel of tests for under-resourced clinic settings, formulated by medical experts, is demonstrated. This emphasizes the potential of centrifugal microfluidic technologies to be applied effectively to extremely challenging point-of-care scenarios and in playing a role in improving primary care in resource-limited settings across the developing world.