Wenwen Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wenwen Zhang has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Qian Chen
School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
6 shared publications - Ruiqing He
Nanjing Institute of Technology
5 shared publications - Cong Ni
Nanjing Univ Sci & Technol, Adv Interdisciplinary Res Ctr Opt, Nanjing 210094, Peoples R China
3 shared publications Qian Chen
Nanjing Univ Sci & Technol, Adv Interdisciplinary Res Ctr Opt, Nanjing 210094, Peoples R China
3 shared publications- Weiji He
Jiangsu Key Laboratory of Spectral Imaging and Intelligence Sense, Nanjing University of Science and Technology, Nanjing, China
3 shared publications Yusen Li
3 shared publications
Latest Publications
- 15 June 2026
- Published by Optica Publishing Group in Photonics Research
- Vol. 14 (8) , 3523
Single-shot super-resolution imaging via a multi-aperture diffractive optical element array
Resolution is critical for modern imaging systems to accurately acquire fine spatial details and support subsequent visual analysis. In applications such as low-light imaging where large-pitch sensors are commonly adopted, sensor sampling capacity becomes the dominant resolution constraint, and enlarging the optical aperture alone cannot recover the high-frequency content lost to aliasing. Fusing multiple measurements can alleviate this limitation, but traditional methods require either sequential mechanical scanning or multi-camera arrays, sacrificing temporal resolution or system compactness. Inspired by the compact form and design flexibility of diffractive optical elements (DOEs), we propose a single-shot super-resolution imaging system based on a monolithically fabricated 4×4 DOE array with engineered sub-pixel displacements. Each sub-aperture of this DOE array captures a slightly shifted, complementary view of the scene. A multi-aperture texture super-resolution network (MATSR-Net) is designed to fuse this high-frequency information across sub-apertures. Experimental results from our prototype demonstrate a twofold increase in resolvable spatial frequency on the 1951 USAF target and achieve the angular resolution up to 0.625 mrad compared with a single sub-aperture DOE system. Furthermore, the proposed method also exhibits better imaging performance in low-light environments relative to single-aperture systems. Beyond super-resolution, the multi-aperture DOE framework offers potential for compact, single-shot multidimensional imaging by encoding optical information across sub-apertures.
- 15 June 2026
- Published by Optica Publishing Group in Photonics Research
- Vol. 14 (8) , 3523
Single-shot super-resolution imaging via a multi-aperture diffractive optical element array
Resolution is critical for modern imaging systems to accurately acquire fine spatial details and support subsequent visual analysis. In applications such as low-light imaging where large-pitch sensors are commonly adopted, sensor sampling capacity becomes the dominant resolution constraint, and enlarging the optical aperture alone cannot recover the high-frequency content lost to aliasing. Fusing multiple measurements can alleviate this limitation, but traditional methods require either sequential mechanical scanning or multi-camera arrays, sacrificing temporal resolution or system compactness. Inspired by the compact form and design flexibility of diffractive optical elements (DOEs), we propose a single-shot super-resolution imaging system based on a monolithically fabricated 4×4 DOE array with engineered sub-pixel displacements. Each sub-aperture of this DOE array captures a slightly shifted, complementary view of the scene. A multi-aperture texture super-resolution network (MATSR-Net) is designed to fuse this high-frequency information across sub-apertures. Experimental results from our prototype demonstrate a twofold increase in resolvable spatial frequency on the 1951 USAF target and achieve the angular resolution up to 0.625 mrad compared with a single sub-aperture DOE system. Furthermore, the proposed method also exhibits better imaging performance in low-light environments relative to single-aperture systems. Beyond super-resolution, the multi-aperture DOE framework offers potential for compact, single-shot multidimensional imaging by encoding optical information across sub-apertures.
- 6 January 2026
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 200
Spectrum aggregation method for spectral mismatch in high-speed MEMS micromirror scanning FMCW LiDAR
- 6 January 2026
- Published by Elsevier in Optics and Lasers in Engineering
- Vol. 200
Spectrum aggregation method for spectral mismatch in high-speed MEMS micromirror scanning FMCW LiDAR
- 18 February 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (4) , 8213-8224
Reconstruction method for Fourier single-pixel imaging by considering the distribution feature of Fourier spectra of images
The sparse sampling method based on Fourier single-pixel imaging technology has attracted a lot of attention, but there is a lack of a general reconstruction method for sparse sampling. To address this problem, a new reconstruction network is proposed with sparse sampling in Fourier domain. This method can achieve high-quality imaging with a low sampling rate and it can also suppress the ringing effect by predicting the frequency and spatial domain information. To preserve the image details, we consider the distribution of the Fourier spectra of images and design the two-dimensional mask and the loss function in the Fourier domain. Experiments show that when the image resolution is 256×256 and the sampling rate is as low as 8%, the reconstructed image can recover fine details of the object, and meanwhile suppress the ringing effect. More importantly, the reconstruction time of the proposed method is as low as 34ms, which is 4 orders of magnitude faster than the compressed sensing algorithm. This work can also be applied to other sparse sampling methods, which significantly promotes the process of practical application of single-pixel technology.
- 18 February 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (4) , 8213-8224
Reconstruction method for Fourier single-pixel imaging by considering the distribution feature of Fourier spectra of images
The sparse sampling method based on Fourier single-pixel imaging technology has attracted a lot of attention, but there is a lack of a general reconstruction method for sparse sampling. To address this problem, a new reconstruction network is proposed with sparse sampling in Fourier domain. This method can achieve high-quality imaging with a low sampling rate and it can also suppress the ringing effect by predicting the frequency and spatial domain information. To preserve the image details, we consider the distribution of the Fourier spectra of images and design the two-dimensional mask and the loss function in the Fourier domain. Experiments show that when the image resolution is 256×256 and the sampling rate is as low as 8%, the reconstructed image can recover fine details of the object, and meanwhile suppress the ringing effect. More importantly, the reconstruction time of the proposed method is as low as 34ms, which is 4 orders of magnitude faster than the compressed sensing algorithm. This work can also be applied to other sparse sampling methods, which significantly promotes the process of practical application of single-pixel technology.
- 19 July 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (15) , 4170-4173
Address model mismatch and defocus in FZA lensless imaging via model-driven CycleGAN
Mask-based lensless imaging systems suffer from model mismatch and defocus. In this Letter, we propose a model-driven CycleGAN, MDGAN, to reconstruct objects within a long distance. MDGAN includes two translation cycles for objects and measurements respectively, each consisting of a forward propagation and a backward reconstruction module. The backward module resembles the Wiener-U-Net, and the forward module consists of the estimated image formation model of a Fresnel zone aperture camera (FZACam), followed by CNN to compensate for the model mismatch. By imposing cycle consistency, the backward module can adaptively match the actual depth-varying imaging process. We demonstrate that MDGAN based on either a simulated or calibrated imaging model produces a higher-quality image compared to existing methods. Thus, it can be applied to other mask-based systems.
- 19 July 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (15) , 4170-4173
Address model mismatch and defocus in FZA lensless imaging via model-driven CycleGAN
Mask-based lensless imaging systems suffer from model mismatch and defocus. In this Letter, we propose a model-driven CycleGAN, MDGAN, to reconstruct objects within a long distance. MDGAN includes two translation cycles for objects and measurements respectively, each consisting of a forward propagation and a backward reconstruction module. The backward module resembles the Wiener-U-Net, and the forward module consists of the estimated image formation model of a Fresnel zone aperture camera (FZACam), followed by CNN to compensate for the model mismatch. By imposing cycle consistency, the backward module can adaptively match the actual depth-varying imaging process. We demonstrate that MDGAN based on either a simulated or calibrated imaging model produces a higher-quality image compared to existing methods. Thus, it can be applied to other mask-based systems.
- 12 March 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (7) , 11323-11336
Extended depth of field for Fresnel zone aperture camera via fast passive depth estimation
The lensless camera with incoherent illumination has gained significant research interest for its thin and flexible structure. However, it faces challenges in resolving scenes with a wide depth of field (DoF) due to its depth-dependent point spread function (PSF). In this paper, we present a single-shot method for extending the DoF in Fresnel zone aperture (FZA) cameras at visible wavelengths through passive depth estimation. The improved ternary search method is utilized to determine the depth of targets rapidly by evaluating the sharpness of the back propagation reconstruction. Based on the depth estimation results, a set of reconstructed images focused on targets at varying depths are derived from the encoded image. After that, the DoF is extended through focus stacking. The experimental results demonstrate an 8-fold increase compared with the calibrated DoF at 130 mm depth. Moreover, our depth estimation method is five times faster than the traversal method, while maintaining the same level of accuracy. The proposed method facilitates the development of lensless imaging in practical applications such as photography, microscopy, and surveillance.
- 12 March 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (7) , 11323-11336
Extended depth of field for Fresnel zone aperture camera via fast passive depth estimation
The lensless camera with incoherent illumination has gained significant research interest for its thin and flexible structure. However, it faces challenges in resolving scenes with a wide depth of field (DoF) due to its depth-dependent point spread function (PSF). In this paper, we present a single-shot method for extending the DoF in Fresnel zone aperture (FZA) cameras at visible wavelengths through passive depth estimation. The improved ternary search method is utilized to determine the depth of targets rapidly by evaluating the sharpness of the back propagation reconstruction. Based on the depth estimation results, a set of reconstructed images focused on targets at varying depths are derived from the encoded image. After that, the DoF is extended through focus stacking. The experimental results demonstrate an 8-fold increase compared with the calibrated DoF at 130 mm depth. Moreover, our depth estimation method is five times faster than the traversal method, while maintaining the same level of accuracy. The proposed method facilitates the development of lensless imaging in practical applications such as photography, microscopy, and surveillance.
- 14 February 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (5) , 7307-7317
Vector-guided Fourier single-pixel imaging
The Fourier single-pixel imaging technique exhibits great potential for compressive imaging. However, the utilization of low sampling ratio can introduce unwanted ringing artifacts, thereby compromising the fidelity of reconstructed image detail. To address this issue, Vector guided Fourier single-pixel imaging (V-FSI) has been proposed. We analyze the statistical properties in the edge vector field derived from images with low sampling ratio. Based on this information, a tailored sampling map is designed to acquire the significant high-frequency components for image reconstruction. Experimental results demonstrate the remarkable effectiveness of the proposed V-FSI method in enhancing image quality. Notably, V-FSI exhibits exceptional capabilities in perceiving and preserving the details of the objects, particularly for objects characterized by pronounced periodicity and directionality.
- 14 February 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (5) , 7307-7317
Vector-guided Fourier single-pixel imaging
The Fourier single-pixel imaging technique exhibits great potential for compressive imaging. However, the utilization of low sampling ratio can introduce unwanted ringing artifacts, thereby compromising the fidelity of reconstructed image detail. To address this issue, Vector guided Fourier single-pixel imaging (V-FSI) has been proposed. We analyze the statistical properties in the edge vector field derived from images with low sampling ratio. Based on this information, a tailored sampling map is designed to acquire the significant high-frequency components for image reconstruction. Experimental results demonstrate the remarkable effectiveness of the proposed V-FSI method in enhancing image quality. Notably, V-FSI exhibits exceptional capabilities in perceiving and preserving the details of the objects, particularly for objects characterized by pronounced periodicity and directionality.
- 18 October 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (22) , 36021-36037
Adaptive Fourier single pixel imaging based on the radial correlation in the Fourier domain
Fourier single-pixel imaging (FSI) can directly measure the Fourier coefficients of an object and reconstruct its image, and the technique has attracted attention recently. However, with the current spectrum sampling methods of FSI it is difficult to balance image details and noise suppression within a limited sampling number and a short reconstruction time. To address this problem, the method of adaptive Fourier single-pixel imaging (A-FSI) is proposed to measure the coefficients of the key spectra adaptively. First we examine radial correlation between low-frequency and high-frequency components in the Fourier domain. Based on this correlation, we estimate the positions of significant high-frequency components through the chosen low-frequency components, measure the corresponding Fourier coefficients and form the image. Importantly, the proposed A-FSI only uses the inverse Fourier transform for reconstruction, which is much faster than the algorithm of compressed sensing under the given conditions. Both the simulations and experiments show that the proposed method can keep details of the image and reduce the noise of reconstruction at same time with a limited sampling number and a short reconstruction time. This technology can promote the practical development of single-pixel imaging.
- 18 October 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (22) , 36021-36037
Adaptive Fourier single pixel imaging based on the radial correlation in the Fourier domain
Fourier single-pixel imaging (FSI) can directly measure the Fourier coefficients of an object and reconstruct its image, and the technique has attracted attention recently. However, with the current spectrum sampling methods of FSI it is difficult to balance image details and noise suppression within a limited sampling number and a short reconstruction time. To address this problem, the method of adaptive Fourier single-pixel imaging (A-FSI) is proposed to measure the coefficients of the key spectra adaptively. First we examine radial correlation between low-frequency and high-frequency components in the Fourier domain. Based on this correlation, we estimate the positions of significant high-frequency components through the chosen low-frequency components, measure the corresponding Fourier coefficients and form the image. Importantly, the proposed A-FSI only uses the inverse Fourier transform for reconstruction, which is much faster than the algorithm of compressed sensing under the given conditions. Both the simulations and experiments show that the proposed method can keep details of the image and reduce the noise of reconstruction at same time with a limited sampling number and a short reconstruction time. This technology can promote the practical development of single-pixel imaging.
- 12 March 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11434, 114340U-58
Research and implementation of color night vision imaging system based on FPGA and CMOS
Introduces a real-time color imaging system can be operated at night and uses a low-cost, simple and convenient CMOS sensor. In this imaging system, the sensor is driven by the FPGA, the differential data output by the sensor is decoded by the FPGA, and a series of image processing algorithms are implemented in the hardware description language through FPGA programming to improve the imaging quality of the system at night. The main problems solved by this imaging system are as follows: (1) For night time light energy is weak, and after adding an IR cut filter, the sensor can capture the problem of insufficient light. This paper proposes an imaging method without an IR cut filter. This method requires a color correction algorithm in the FPGA to correct the color distortion caused by the transmission of near-infrared light. (2) The problem of low contrast and insufficient color saturation for night time imaging results. This paper combines the gamma correction algorithm and the defogging algorithm to propose a method that can effectively improve the image color saturation. The combination of the two algorithms can improve the brightness of the nighttime image and make the image more vivid. (3) When imaging a single color sensor at night, the details and brightness of the captured object still do not meet the needs of the human eye. In this paper, a mono and color dual-camera system is used to improve imaging quality. In this system, two sensors are simultaneously imaged, so that the imaging results retain both the color information of the color sensor and the clarity of the mono sensor.
- 12 March 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11434, 114340U-58
Research and implementation of color night vision imaging system based on FPGA and CMOS
Introduces a real-time color imaging system can be operated at night and uses a low-cost, simple and convenient CMOS sensor. In this imaging system, the sensor is driven by the FPGA, the differential data output by the sensor is decoded by the FPGA, and a series of image processing algorithms are implemented in the hardware description language through FPGA programming to improve the imaging quality of the system at night. The main problems solved by this imaging system are as follows: (1) For night time light energy is weak, and after adding an IR cut filter, the sensor can capture the problem of insufficient light. This paper proposes an imaging method without an IR cut filter. This method requires a color correction algorithm in the FPGA to correct the color distortion caused by the transmission of near-infrared light. (2) The problem of low contrast and insufficient color saturation for night time imaging results. This paper combines the gamma correction algorithm and the defogging algorithm to propose a method that can effectively improve the image color saturation. The combination of the two algorithms can improve the brightness of the nighttime image and make the image more vivid. (3) When imaging a single color sensor at night, the details and brightness of the captured object still do not meet the needs of the human eye. In this paper, a mono and color dual-camera system is used to improve imaging quality. In this system, two sensors are simultaneously imaged, so that the imaging results retain both the color information of the color sensor and the clarity of the mono sensor.
- 18 September 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (20) , 27862-27872
Adaptive compressed 3D ghost imaging based on the variation of surface normals
Three-dimensional (3D) imaging can be reconstructed by a computational ghost imaging system with single pixel detectors based on a photometric stereo, but the requirement of large measurements and long imaging times are obstacles to its development. Also, the compressibility of the target’s surface normals has not been fully studied, which causes the waste in sampling efficiency in single-pixel imaging. In this paper, we propose a method to adaptively measure the object’s 3D information based on surface normals. In the proposed method, the regions of object’s surface are illuminated by patterns of different spatial resolutions according to the variation of surface normals. The experimental results demonstrate that our proposed scheme can reduce measurements and preserve the quality of the formed 3D image.
- 18 September 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (20) , 27862-27872
Adaptive compressed 3D ghost imaging based on the variation of surface normals
Three-dimensional (3D) imaging can be reconstructed by a computational ghost imaging system with single pixel detectors based on a photometric stereo, but the requirement of large measurements and long imaging times are obstacles to its development. Also, the compressibility of the target’s surface normals has not been fully studied, which causes the waste in sampling efficiency in single-pixel imaging. In this paper, we propose a method to adaptively measure the object’s 3D information based on surface normals. In the proposed method, the regions of object’s surface are illuminated by patterns of different spatial resolutions according to the variation of surface normals. The experimental results demonstrate that our proposed scheme can reduce measurements and preserve the quality of the formed 3D image.
- Open Access
- 25 January 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (3) , 2344-2353
Improving the noise immunity of 3D computational ghost imaging
Computational ghost imaging (CGI) can build a three-dimensional (3D) image using the reconstructed shading images. However, it could be easily affected by the noise accumulated in the 3D reconstruction. More importantly, the selection of initial growing position will also affect the quality of the formed 3D image significantly. In this paper, we apply the technique of sub-pixel displacement to achieve smooth shading images in noisy environments and propose a method for selecting the optimal initial growing position to preserve the stereo feature of the object. We demonstrate that the surfaces of the reconstructed 3D images are more accurate using our proposed method as compared to the ones achieved by previously used methods. Our research would promote the development of 3D imaging using CGI in noisy environments.
- 25 January 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (3) , 2344-2353
Open AccessImproving the noise immunity of 3D computational ghost imaging
Computational ghost imaging (CGI) can build a three-dimensional (3D) image using the reconstructed shading images. However, it could be easily affected by the noise accumulated in the 3D reconstruction. More importantly, the selection of initial growing position will also affect the quality of the formed 3D image significantly. In this paper, we apply the technique of sub-pixel displacement to achieve smooth shading images in noisy environments and propose a method for selecting the optimal initial growing position to preserve the stereo feature of the object. We demonstrate that the surfaces of the reconstructed 3D images are more accurate using our proposed method as compared to the ones achieved by previously used methods. Our research would promote the development of 3D imaging using CGI in noisy environments.