Jiaywei Tsauo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jiaywei Tsauo has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Xiao Li
Department of Interventional Therapy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China
14 shared publications He Zhao
Department of Interventional Therapy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
9 shared publicationsTao Gong
Department of Interventional Therapy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
7 shared publicationsXiaowu Zhang
Department of Interventional Therapy, National Cancer Center, National Clinical Research Center, Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
7 shared publicationsJingui Li
Department of Interventional Therapy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
6 shared publications- Jung-Hoon Park
Department of Convergence Medicine Asan Medical Center University of Ulsan College of Medicine Seoul Republic of Korea
5 shared publications
Latest Publications
- Open Access
- 31 July 2025
- Published by Society of Gastrointestinal Intervention in International Journal of Gastrointestinal Intervention
- Vol. 14 (3) , 93-97
Embolization coils: Materials, designs, and future directions
Jiaywei Tsauo. Int J Gastrointest Interv 2025;14:93-7. https://doi.org/10.18528/ijgii250044
- 31 July 2025
- Published by Society of Gastrointestinal Intervention in International Journal of Gastrointestinal Intervention
- Vol. 14 (3) , 93-97
Open AccessEmbolization coils: Materials, designs, and future directions
Jiaywei Tsauo. Int J Gastrointest Interv 2025;14:93-7. https://doi.org/10.18528/ijgii250044
- Open Access
- 5 October 2024
- Published by Springer Nature in BMC Urology
- Vol. 24 (1) , 1-7
Safety and efficacy of thermo-expandable metallic stent in ureteral stricture following gynecological malignancy surgery and radiotherapy: a single center experience with 33 cases
The effectiveness of metallic stents in treating ureteral strictures following surgery and radiotherapy for gynecological tumors is currently uncertain. We aimed to investigate the efficacy and safety of thermo-expandable metallic stent (Memokath) in the treatment of ureteral stricture after radiotherapy for gynecological tumors. In this descriptive cross-sectional study, 27 patients with ureteral stricture were treated with Memokath stent after gynecological tumor radiotherapy with or without chemotherapy that was admitted to our hospital from August 2021 to August 2023. Clinical data on efficacy, safety, and complications during stent insertion and indwelling were analyzed. The successful insertion of thirty-three stents in twenty-seven patients studied. The stenosis length was 10.14 ± 6.76 cm, and the hospitalization was 4.43 ± 1.83 days. One patient has died from the primary disease carrying a patency stent. The Kaplan-Meier graph showed that the cumilative patency rate of patients with thermo-expandable metallic stent were 92.4% (SD = 5.2%) in eight months, 77.4% (9.1%) in 12 months and 67.7% (SD = 12%) in 29 months, while the cumilative survival rate was 87.5% (SD = 11.5%) in 29 months. The stent patency was 81.48% and later complications of stent indwelling were 5/27, including refractory urinary tract infection (UTI) in three cases, stent migration, and stent intolerance respectively. The creatinine levels, hydronephrosis degree, and glomerular filtration rate improved after the operation, and the first two indicators were statistically significant. Memokath stent is a safe and effective treatment for ureteral stricture after surgery and radiotherapy with or without chemotherapy for gynecological tumors.
- 5 October 2024
- Published by Springer Nature in BMC Urology
- Vol. 24 (1) , 1-7
Open AccessSafety and efficacy of thermo-expandable metallic stent in ureteral stricture following gynecological malignancy surgery and radiotherapy: a single center experience with 33 cases
The effectiveness of metallic stents in treating ureteral strictures following surgery and radiotherapy for gynecological tumors is currently uncertain. We aimed to investigate the efficacy and safety of thermo-expandable metallic stent (Memokath) in the treatment of ureteral stricture after radiotherapy for gynecological tumors. In this descriptive cross-sectional study, 27 patients with ureteral stricture were treated with Memokath stent after gynecological tumor radiotherapy with or without chemotherapy that was admitted to our hospital from August 2021 to August 2023. Clinical data on efficacy, safety, and complications during stent insertion and indwelling were analyzed. The successful insertion of thirty-three stents in twenty-seven patients studied. The stenosis length was 10.14 ± 6.76 cm, and the hospitalization was 4.43 ± 1.83 days. One patient has died from the primary disease carrying a patency stent. The Kaplan-Meier graph showed that the cumilative patency rate of patients with thermo-expandable metallic stent were 92.4% (SD = 5.2%) in eight months, 77.4% (9.1%) in 12 months and 67.7% (SD = 12%) in 29 months, while the cumilative survival rate was 87.5% (SD = 11.5%) in 29 months. The stent patency was 81.48% and later complications of stent indwelling were 5/27, including refractory urinary tract infection (UTI) in three cases, stent migration, and stent intolerance respectively. The creatinine levels, hydronephrosis degree, and glomerular filtration rate improved after the operation, and the first two indicators were statistically significant. Memokath stent is a safe and effective treatment for ureteral stricture after surgery and radiotherapy with or without chemotherapy for gynecological tumors.
- Open Access
- 3 April 2024
- Published by Springer Nature in European Radiology Experimental
- Vol. 8 (1) , 1-11
Local hyperthermia mediated by gold nanoparticle-integrated silicone-covered stent: feasibility and tissue response in a rat esophageal model
Background: To assess the feasibility and tissue response of using a gold nanoparticle (AuNP)-integrated silicone-covered self-expandable metal stent (SEMS) for local hyperthermia in a rat esophageal model. Methods: The study involved 42 Sprague–Dawley rats. Initially, 6 animals were subjected to near-infrared (NIR) laser irradiation (power output from 0.2 to 2.4 W) to assess the in vitro heating characteristics of the AuNP-integrated SEMS immediately after its placement. The surface temperature of the stented esophagus was then measured using an infrared thermal camera before euthanizing the animals. Subsequently, the remaining 36 animals were randomly divided into 4 groups of 9 each. Groups A and B received AuNP-integrated SEMS, while groups C and D received conventional SEMS. On day 14, groups A and C underwent NIR laser irradiation at a power output of 1.6 W for 2 min. By days 15 (3 animals per group) or 28 (6 animals per group), all groups were euthanized for gross, histological, and immunohistochemical analysis. Results: Under NIR laser irradiation, the surface temperature of the stented esophagus quickly increased to a steady-state level. The surface temperature of the stented esophagus increased proportionally with power outputs, being 47.3 ± 1.4 °C (mean ± standard deviation) at 1.6 W. Only group A attained full circumferential heating through all layers, from the epithelium to the muscularis propria, demonstrating marked apoptosis in these layers without noticeable necroptosis. Conclusions: Local hyperthermia using the AuNP-integrated silicone-covered SEMS was feasible and induced cell death through apoptosis in a rat esophageal model. Relevance statement: A gold nanoparticle-integrated silicone-covered self-expanding metal stent has been developed to mediate local hyperthermia. This approach holds potential for irreversibly damaging cancer cells, improving the sensitivity of cancer cells to therapies, and triggering systemic anticancer immune responses. Key points: • A gold nanoparticle-integrated silicone-covered self-expanding metal stent was placed in the rat esophagus. • Upon near-infrared laser irradiation, this stent quickly increased the temperature of the stented esophagus. • Local hyperthermia using this stent was feasible and resulted in cell death through apoptosis. Graphical
- 3 April 2024
- Published by Springer Nature in European Radiology Experimental
- Vol. 8 (1) , 1-11
Open AccessLocal hyperthermia mediated by gold nanoparticle-integrated silicone-covered stent: feasibility and tissue response in a rat esophageal model
Background: To assess the feasibility and tissue response of using a gold nanoparticle (AuNP)-integrated silicone-covered self-expandable metal stent (SEMS) for local hyperthermia in a rat esophageal model. Methods: The study involved 42 Sprague–Dawley rats. Initially, 6 animals were subjected to near-infrared (NIR) laser irradiation (power output from 0.2 to 2.4 W) to assess the in vitro heating characteristics of the AuNP-integrated SEMS immediately after its placement. The surface temperature of the stented esophagus was then measured using an infrared thermal camera before euthanizing the animals. Subsequently, the remaining 36 animals were randomly divided into 4 groups of 9 each. Groups A and B received AuNP-integrated SEMS, while groups C and D received conventional SEMS. On day 14, groups A and C underwent NIR laser irradiation at a power output of 1.6 W for 2 min. By days 15 (3 animals per group) or 28 (6 animals per group), all groups were euthanized for gross, histological, and immunohistochemical analysis. Results: Under NIR laser irradiation, the surface temperature of the stented esophagus quickly increased to a steady-state level. The surface temperature of the stented esophagus increased proportionally with power outputs, being 47.3 ± 1.4 °C (mean ± standard deviation) at 1.6 W. Only group A attained full circumferential heating through all layers, from the epithelium to the muscularis propria, demonstrating marked apoptosis in these layers without noticeable necroptosis. Conclusions: Local hyperthermia using the AuNP-integrated silicone-covered SEMS was feasible and induced cell death through apoptosis in a rat esophageal model. Relevance statement: A gold nanoparticle-integrated silicone-covered self-expanding metal stent has been developed to mediate local hyperthermia. This approach holds potential for irreversibly damaging cancer cells, improving the sensitivity of cancer cells to therapies, and triggering systemic anticancer immune responses. Key points: • A gold nanoparticle-integrated silicone-covered self-expanding metal stent was placed in the rat esophagus. • Upon near-infrared laser irradiation, this stent quickly increased the temperature of the stented esophagus. • Local hyperthermia using this stent was feasible and resulted in cell death through apoptosis. Graphical
- Open Access
- 19 February 2024
- Published by Springer Nature in European Radiology Experimental
- Vol. 8 (1) , 1-12
Characteristics of four commonly used self-expanding biliary stents: an in vitro study
Background: Knowledge of the characteristics of self-expanding metal stents (SEMSs) is essential during selection process to ensure the best therapeutic outcomes for patients with malignant biliary obstruction. The aim of this study was to evaluate the characteristics of four commonly used SEMSs. Methods: This in vitro study analyzed the radial force (RF), crush resistance (CR), axial force (AF), conformability, surface quality, foreshortening, and radiopacity of the following SEMSs: uncovered Wallflex™, EGIS single bare, Zilver 635®, and E-Luminexx™. Two samples of each SEMS type were included in this study, all having identical specifications with a diameter of 10 mm and a length of 6 cm. One sample from each type was analyzed for surface quality, followed by CR, conformability, and foreshortening. The other sample was analyzed for radiopacity, followed by RF and AF. Results: The uncovered Wallflex™ exhibited low RF, high CR, high AF, good conformability, poor surface quality, high foreshortening, and good radiopacity. The EGIS single bare demonstrated high RF, high CR, low AF, moderate conformability, good surface quality, high foreshortening, and poor radiopacity. The Zilver 635® displayed moderate RF, low CR, low AF, moderate conformability, moderate surface quality, no foreshortening, and good radiopacity. The E-Luminexx™ showed high RF, moderate CR, high AF, poor conformability, poor surface quality, no foreshortening, and good radiopacity. Conclusions: There was considerable variation in the characteristics among the four evaluated SEMSs. These characteristics should be carefully considered during selection to ensure optimal therapeutic outcomes for patients. Relevance statement: The selection of self-expanding metal stents for treating malignant biliary obstruction requires careful consideration of various characteristics, including their radial force, crush resistance, axial force, conformability, surface quality, foreshortening, and radiopacity. Key points: • The characteristics of self-expanding metal stents (SEMSs) can vary considerably. • Specific situations may warrant the use of SEMSs with particular characteristics over others. • Characteristics of SEMSs must be considered during selection for optimal outcomes. Graphical
- 19 February 2024
- Published by Springer Nature in European Radiology Experimental
- Vol. 8 (1) , 1-12
Open AccessCharacteristics of four commonly used self-expanding biliary stents: an in vitro study
Background: Knowledge of the characteristics of self-expanding metal stents (SEMSs) is essential during selection process to ensure the best therapeutic outcomes for patients with malignant biliary obstruction. The aim of this study was to evaluate the characteristics of four commonly used SEMSs. Methods: This in vitro study analyzed the radial force (RF), crush resistance (CR), axial force (AF), conformability, surface quality, foreshortening, and radiopacity of the following SEMSs: uncovered Wallflex™, EGIS single bare, Zilver 635®, and E-Luminexx™. Two samples of each SEMS type were included in this study, all having identical specifications with a diameter of 10 mm and a length of 6 cm. One sample from each type was analyzed for surface quality, followed by CR, conformability, and foreshortening. The other sample was analyzed for radiopacity, followed by RF and AF. Results: The uncovered Wallflex™ exhibited low RF, high CR, high AF, good conformability, poor surface quality, high foreshortening, and good radiopacity. The EGIS single bare demonstrated high RF, high CR, low AF, moderate conformability, good surface quality, high foreshortening, and poor radiopacity. The Zilver 635® displayed moderate RF, low CR, low AF, moderate conformability, moderate surface quality, no foreshortening, and good radiopacity. The E-Luminexx™ showed high RF, moderate CR, high AF, poor conformability, poor surface quality, no foreshortening, and good radiopacity. Conclusions: There was considerable variation in the characteristics among the four evaluated SEMSs. These characteristics should be carefully considered during selection to ensure optimal therapeutic outcomes for patients. Relevance statement: The selection of self-expanding metal stents for treating malignant biliary obstruction requires careful consideration of various characteristics, including their radial force, crush resistance, axial force, conformability, surface quality, foreshortening, and radiopacity. Key points: • The characteristics of self-expanding metal stents (SEMSs) can vary considerably. • Specific situations may warrant the use of SEMSs with particular characteristics over others. • Characteristics of SEMSs must be considered during selection for optimal outcomes. Graphical
- 1 March 2022
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 10 (2) , 463-468.e2
Comparison of the in vitro clot-capturing efficiencies of commercially available retrievable inferior vena cava filters
- 1 March 2022
- Published by Elsevier in Journal of Vascular Surgery: Venous and Lymphatic Disorders
- Vol. 10 (2) , 463-468.e2
Comparison of the in vitro clot-capturing efficiencies of commercially available retrievable inferior vena cava filters
- Open Access
- 30 April 2021
- Published by Society of Gastrointestinal Intervention in International Journal of Gastrointestinal Intervention
- Vol. 10 (2) , 63-66
Fluoroscopy-guided gastrojejunostomy: A work in progress
Jingui Li, Tao Gong, and Jiaywei Tsauo. Int J Gastrointest Interv 2021;10:63-6. https://doi.org/10.18528/ijgii210002
- 30 April 2021
- Published by Society of Gastrointestinal Intervention in International Journal of Gastrointestinal Intervention
- Vol. 10 (2) , 63-66
Open AccessFluoroscopy-guided gastrojejunostomy: A work in progress
Jingui Li, Tao Gong, and Jiaywei Tsauo. Int J Gastrointest Interv 2021;10:63-6. https://doi.org/10.18528/ijgii210002
- 4 January 2021
- Published by Springer Nature in Surgical Endoscopy
- Vol. 36 (1) , 66-74
Silver nanoparticle-coated self-expandable metallic stent suppresses tissue hyperplasia in a rat esophageal model
Background To evaluate the efficacy of a silver nanoparticle (AgNP)-coated self-expandable metallic stent (SEMS) for suppressing tissue hyperplasia in a rat esophageal model. Methods Twenty-four male Sprague-Dawley rats were randomly assigned to four groups. Animals in group A underwent uncoated SEMS placement, whereas animals in groups B, C, and D underwent 6, 12, and 24 mg/mL AgNP-coated SEMS placement, respectively. All animals were euthanized 4 weeks after SEMS placement, and a gross examination and histological analyses were performed. Results All rats achieved technical success and survived until the end of the study. The gross examination showed moderate to severe tissue hyperplasia in 5 rats in group A and 2 rats in group B. In contrast, no animals in groups C and D had moderate or severe tissue hyperplasia. The gross examination revealed no complications. The percentage of granulation tissue area, number of epithelial layers, thickness of submucosal fibrosis, percentage of connective tissue area, inflammatory cell infiltration grade, degree of collagen deposition, and degrees of Ki67, TUNEL, and α-SMA-positive deposition were significantly lower in groups C and D than in group A (all p < 0.05). However, only the percentage of granulation tissue area, number of epithelial layers, thickness of submucosal fibrosis, and percentage of connective tissue area were significantly lower in group B than in group A (all p < 0.05). No histological parameters were significantly different between group D and group C (all p > 0.05). Conclusion AgNP-coated SEMSs suppressed tissue hyperplasia in a rat esophageal model.
- 4 January 2021
- Published by Springer Nature in Surgical Endoscopy
- Vol. 36 (1) , 66-74
Silver nanoparticle-coated self-expandable metallic stent suppresses tissue hyperplasia in a rat esophageal model
Background To evaluate the efficacy of a silver nanoparticle (AgNP)-coated self-expandable metallic stent (SEMS) for suppressing tissue hyperplasia in a rat esophageal model. Methods Twenty-four male Sprague-Dawley rats were randomly assigned to four groups. Animals in group A underwent uncoated SEMS placement, whereas animals in groups B, C, and D underwent 6, 12, and 24 mg/mL AgNP-coated SEMS placement, respectively. All animals were euthanized 4 weeks after SEMS placement, and a gross examination and histological analyses were performed. Results All rats achieved technical success and survived until the end of the study. The gross examination showed moderate to severe tissue hyperplasia in 5 rats in group A and 2 rats in group B. In contrast, no animals in groups C and D had moderate or severe tissue hyperplasia. The gross examination revealed no complications. The percentage of granulation tissue area, number of epithelial layers, thickness of submucosal fibrosis, percentage of connective tissue area, inflammatory cell infiltration grade, degree of collagen deposition, and degrees of Ki67, TUNEL, and α-SMA-positive deposition were significantly lower in groups C and D than in group A (all p < 0.05). However, only the percentage of granulation tissue area, number of epithelial layers, thickness of submucosal fibrosis, and percentage of connective tissue area were significantly lower in group B than in group A (all p < 0.05). No histological parameters were significantly different between group D and group C (all p > 0.05). Conclusion AgNP-coated SEMSs suppressed tissue hyperplasia in a rat esophageal model.
- 10 July 2020
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 43 (11) , 1687-1694
Fluoroscopy-Guided Gastrojejunostomy Creation with Lumen-Apposing Metal Stent in a Porcine Model
Purpose To evaluate the technical feasibility of fluoroscopy-guided gastrojejunostomy creation in a porcine model. Methods Eight domestic female pigs (median, 15.6 kg; range, 14.5–16.3 kg) were included in this study. The proximal jejunum was punctured from the stomach using a Rösch–Uchida Transjugular Liver Access Set through the mouth, and a lumen-apposing metal stent was placed across the puncture tract between the stomach and the proximal jejunum. All animals were euthanized 6 weeks after the procedure. Results The fistulous tract creation and stent insertion with confirmed patency were successful in eight animals, rendering a technical success rate of 100%. Gross inspection showed a matured and patent fistulous tract between the stomach and the proximal jejunum in seven animals. In one animal, the colon between the stomach and the proximal jejunum was inadvertently punctured followed by migration of the stent from the stomach into the colon after the procedure to form a delayed jejunocolostomy. A stent migration and an inadvertent traversing the tail of pancreas by the stent were observed in another two animals without signs of bleeding, infection, or pancreatitis. All animals survived until the end of this study without change in their behavior or appetite. Histological analysis showed that all the fistulous tracts had matured with continuity of submucosal, muscular, and serosal layers, and without destruction of epithelial layers. Conclusions Fluoroscopy-guided gastrojejunostomy creation is technically feasible in a porcine model but requires refinement of the targeting technique to avoid transgression of nontarget organs.
- 10 July 2020
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 43 (11) , 1687-1694
Fluoroscopy-Guided Gastrojejunostomy Creation with Lumen-Apposing Metal Stent in a Porcine Model
Purpose To evaluate the technical feasibility of fluoroscopy-guided gastrojejunostomy creation in a porcine model. Methods Eight domestic female pigs (median, 15.6 kg; range, 14.5–16.3 kg) were included in this study. The proximal jejunum was punctured from the stomach using a Rösch–Uchida Transjugular Liver Access Set through the mouth, and a lumen-apposing metal stent was placed across the puncture tract between the stomach and the proximal jejunum. All animals were euthanized 6 weeks after the procedure. Results The fistulous tract creation and stent insertion with confirmed patency were successful in eight animals, rendering a technical success rate of 100%. Gross inspection showed a matured and patent fistulous tract between the stomach and the proximal jejunum in seven animals. In one animal, the colon between the stomach and the proximal jejunum was inadvertently punctured followed by migration of the stent from the stomach into the colon after the procedure to form a delayed jejunocolostomy. A stent migration and an inadvertent traversing the tail of pancreas by the stent were observed in another two animals without signs of bleeding, infection, or pancreatitis. All animals survived until the end of this study without change in their behavior or appetite. Histological analysis showed that all the fistulous tracts had matured with continuity of submucosal, muscular, and serosal layers, and without destruction of epithelial layers. Conclusions Fluoroscopy-guided gastrojejunostomy creation is technically feasible in a porcine model but requires refinement of the targeting technique to avoid transgression of nontarget organs.
- 31 March 2020
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 43 (9) , 1285-1293
Systemic Therapy Plus Thermal Ablation Versus Systemic Therapy Alone for Oligometastatic Liver Metastases from Non-small Cell Lung Cancer
Purpose This study assessed and compared the efficacy and long-term outcomes of systemic therapy plus image-guided thermal ablation versus systemic therapy alone for oligometastatic liver metastases (LMs) from non-small cell lung cancer (NSCLC). Materials and Methods This retrospective study was approved by the institutional review board. Written informed consent was waived due to the retrospective design. From November 2012 to December 2017, 61 patients (mean age 59.0 years; 35 males) with oligometastatic LMs from NSCLC (≤ 5 metastatic lesions) who received systemic therapy with (n = 21, group A) or without (n = 40, group B) thermal ablation were analyzed. Progression-free survival (PFS) and overall survival (OS) were estimated by Kaplan–Meier curves. Results The demographic and clinical characteristics were not significantly different between the groups (all P ≥ .05). In total, 28 LMs were entirely ablated, rendering a technical success rate of 100%, without major complications. The overall 6-month response rate was significantly higher in group A than in group B [57.1% (12/21) vs. 26.3% (10/38); P = .026]. The median PFS in group A was significantly longer than in group B [11.0 (95% CI 7.9–16.2) months vs. 5.2 (95% CI 3.7–7.9) months; P = .001]. However, the median OS was not significantly different [27.7 (95% CI 20.6–44.4) months vs. 17.7 (95% CI 14.5–27.5) months; P = .152]. Conclusion Systemic therapy plus thermal ablation may prolong PFS but not OS in oligometastatic LMs from NSCLC.
- 31 March 2020
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 43 (9) , 1285-1293
Systemic Therapy Plus Thermal Ablation Versus Systemic Therapy Alone for Oligometastatic Liver Metastases from Non-small Cell Lung Cancer
Purpose This study assessed and compared the efficacy and long-term outcomes of systemic therapy plus image-guided thermal ablation versus systemic therapy alone for oligometastatic liver metastases (LMs) from non-small cell lung cancer (NSCLC). Materials and Methods This retrospective study was approved by the institutional review board. Written informed consent was waived due to the retrospective design. From November 2012 to December 2017, 61 patients (mean age 59.0 years; 35 males) with oligometastatic LMs from NSCLC (≤ 5 metastatic lesions) who received systemic therapy with (n = 21, group A) or without (n = 40, group B) thermal ablation were analyzed. Progression-free survival (PFS) and overall survival (OS) were estimated by Kaplan–Meier curves. Results The demographic and clinical characteristics were not significantly different between the groups (all P ≥ .05). In total, 28 LMs were entirely ablated, rendering a technical success rate of 100%, without major complications. The overall 6-month response rate was significantly higher in group A than in group B [57.1% (12/21) vs. 26.3% (10/38); P = .026]. The median PFS in group A was significantly longer than in group B [11.0 (95% CI 7.9–16.2) months vs. 5.2 (95% CI 3.7–7.9) months; P = .001]. However, the median OS was not significantly different [27.7 (95% CI 20.6–44.4) months vs. 17.7 (95% CI 14.5–27.5) months; P = .152]. Conclusion Systemic therapy plus thermal ablation may prolong PFS but not OS in oligometastatic LMs from NSCLC.