Hashim Alhmoud
Hashim Alhmoud has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Mehmet Selim Hanay
Bilkent University
7 shared publications - Nicolas Hans Voelcker
Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Australia
5 shared publications Bahman Delalat
Future Ind. Inst., Univ. South. Aust., Mawson Lakes 5095, Australia
4 shared publications- Batuhan Emre Kaynak
Department of Mechanical Engineering, Bilkent University, 06800 Ankara, Turkey
4 shared publications - Roey Elnathan
Monash Institute of Pharmaceutical Sciences Monash University Parkville VIC 3052 Australia
4 shared publications Uzay Tefek
Department of Mechanical Engineering
4 shared publications
Latest Publications
- Open Access
- 18 March 2025
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 10 (3) , 1729-1735
Rapid Differentiation between Microplastic Particles Using Integrated Microwave Cytometry with 3D Electrodes
Rapid identification of microparticles in liquid is an important problem in environmental and biomedical applications such as microplastic detection in water sources and physiological fluids. Existing spectroscopic techniques are usually slow and not compatible with flow-through systems. Here we analyze single microparticles in the 10-24 μm range using a combination of two electronic sensors in the same microfluidic system: a microwave capacitive sensor and a resistive pulse sensor. Together, this integrated sensor system yields an electrical signature of the analyte particles for their differentiation. To simplify data analysis, 3D electrode arrangements were used instead of planar electrodes so that the generated signal is unaffected by the height of the particle in the microfluidic channel. With this platform, we were able to distinguish between polystyrene (PS) and polyethylene (PE) microparticles. We showcase the sensitivity and speed of this technique and discuss the implications for the future application of microwave cytometry technology in the environmental and biomedical fields.
- 18 March 2025
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 10 (3) , 1729-1735
Open AccessRapid Differentiation between Microplastic Particles Using Integrated Microwave Cytometry with 3D Electrodes
Rapid identification of microparticles in liquid is an important problem in environmental and biomedical applications such as microplastic detection in water sources and physiological fluids. Existing spectroscopic techniques are usually slow and not compatible with flow-through systems. Here we analyze single microparticles in the 10-24 μm range using a combination of two electronic sensors in the same microfluidic system: a microwave capacitive sensor and a resistive pulse sensor. Together, this integrated sensor system yields an electrical signature of the analyte particles for their differentiation. To simplify data analysis, 3D electrode arrangements were used instead of planar electrodes so that the generated signal is unaffected by the height of the particle in the microfluidic channel. With this platform, we were able to distinguish between polystyrene (PS) and polyethylene (PE) microparticles. We showcase the sensitivity and speed of this technique and discuss the implications for the future application of microwave cytometry technology in the environmental and biomedical fields.
- Open Access
- 7 February 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (7) , 7827-7834
Dielectric Detection of Single Nanoparticles Using a Microwave Resonator Integrated with a Nanopore
The characterization of individual nanoparticles in a liquid constitutes a critical challenge for the environmental, material, and biological sciences. To detect nanoparticles, electronic approaches are especially desirable owing to their compactness and lower costs. While electronic detection in the form of resistive-pulse sensing has enabled the acquisition of geometric properties of various analytes, impedimetric measurements to obtain dielectric signatures of nanoparticles have scarcely been reported. To explore this orthogonal sensing modality, we developed an impedimetric sensor based on a microwave resonator with a nanoscale sensing gap surrounding a nanopore built on a 220 nm silicon nitride membrane. The microwave resonator has a coplanar waveguide configuration with a resonance frequency of approximately 6.6 GHz. The approach of single nanoparticles near the sensing region and their translocation through the nanopores induced sudden changes in the impedance of the structure. The impedance changes, in turn, were picked up by the phase response of the microwave resonator. We worked with 100 and 50 nm polystyrene nanoparticles to observe single-particle events. Our current implementation was limited by the nonuniform electric field at the sensing region. This work provides a complementary sensing modality for nanoparticle characterization, where the dielectric response, rather than ionic current, determines the signal.
- 7 February 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (7) , 7827-7834
Open AccessDielectric Detection of Single Nanoparticles Using a Microwave Resonator Integrated with a Nanopore
The characterization of individual nanoparticles in a liquid constitutes a critical challenge for the environmental, material, and biological sciences. To detect nanoparticles, electronic approaches are especially desirable owing to their compactness and lower costs. While electronic detection in the form of resistive-pulse sensing has enabled the acquisition of geometric properties of various analytes, impedimetric measurements to obtain dielectric signatures of nanoparticles have scarcely been reported. To explore this orthogonal sensing modality, we developed an impedimetric sensor based on a microwave resonator with a nanoscale sensing gap surrounding a nanopore built on a 220 nm silicon nitride membrane. The microwave resonator has a coplanar waveguide configuration with a resonance frequency of approximately 6.6 GHz. The approach of single nanoparticles near the sensing region and their translocation through the nanopores induced sudden changes in the impedance of the structure. The impedance changes, in turn, were picked up by the phase response of the microwave resonator. We worked with 100 and 50 nm polystyrene nanoparticles to observe single-particle events. Our current implementation was limited by the nonuniform electric field at the sensing region. This work provides a complementary sensing modality for nanoparticle characterization, where the dielectric response, rather than ionic current, determines the signal.
- Open Access
- 15 October 2023
- Published by Wiley in Advanced Materials
- Vol. 35 (46) , e2304072
Permittivity‐Based Microparticle Classification by the Integration of Impedance Cytometry and Microwave Resonators
Permittivity of microscopic particles can be used as a classification parameter for applications in materials and environmental sciences. However, directly measuring the permittivity of individual microparticles has proven to be challenging due to the convoluting effect of particle size on capacitive signals. To overcome this challenge, a sensing platform is built to independently obtain both the geometric and electric size of a particle, by combining impedance cytometry and microwave resonant sensing in a microfluidic chip. This way the microwave signal, which contains both permittivity and size effects, can be normalized by the size information provided by impedance cytometry to yield an intensive parameter that depends only on permittivity. The technique allows to differentiate between polystyrene and soda lime glass microparticles—below 22 µm in diameter—with more than 94% accuracy, despite their similar sizes and electrical characteristics. Furthermore, it is shown that the same technique can be used to differentiate between normal healthy cells and fixed cells of the same geometric size. The technique offers a potential route for targeted applications such as environmental monitoring of microplastic pollution or quality control in pharmaceutical industry.
- 15 October 2023
- Published by Wiley in Advanced Materials
- Vol. 35 (46) , e2304072
Open AccessPermittivity‐Based Microparticle Classification by the Integration of Impedance Cytometry and Microwave Resonators
Permittivity of microscopic particles can be used as a classification parameter for applications in materials and environmental sciences. However, directly measuring the permittivity of individual microparticles has proven to be challenging due to the convoluting effect of particle size on capacitive signals. To overcome this challenge, a sensing platform is built to independently obtain both the geometric and electric size of a particle, by combining impedance cytometry and microwave resonant sensing in a microfluidic chip. This way the microwave signal, which contains both permittivity and size effects, can be normalized by the size information provided by impedance cytometry to yield an intensive parameter that depends only on permittivity. The technique allows to differentiate between polystyrene and soda lime glass microparticles—below 22 µm in diameter—with more than 94% accuracy, despite their similar sizes and electrical characteristics. Furthermore, it is shown that the same technique can be used to differentiate between normal healthy cells and fixed cells of the same geometric size. The technique offers a potential route for targeted applications such as environmental monitoring of microplastic pollution or quality control in pharmaceutical industry.
- 1 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (7) , 6517-6529
High-Resolution Dielectric Characterization of Single Cells and Microparticles Using Integrated Microfluidic Microwave Sensors
Microwave sensors can probe intrinsic material properties of analytes in a microfluidic channel at physiologically relevant ion concentrations. While microwave sensors have been used to detect single cells and microparticles in earlier studies, the synergistic use and comparative analysis of microwave sensors with optical microscopy for material classification and size tracking applications have been scarcely investigated so far. Here we combined microwave and optical sensing to differentiate microscale objects based on their dielectric properties. We designed and fabricated two types of planar sensor: a Coplanar Waveguide Resonator (CPW) and a Split-Ring Resonator (SRR). Both sensors possessed sensing electrodes with a narrow gap to detect single cells passing through a microfluidic channel integrated on the same chip. We also show that standalone microwave sensors can track the relative changes in cellular size in real-time. In sensing single 20-micron diameter polystyrene particles, Signal-to-Noise ratio values of approximately 100 for CPW and 70 for SRR sensors were obtained. These findings demonstrate that microwave sensing technology can serve as a complementary technique for single-cell biophysical experiments and microscale pollutant screening.
- 1 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (7) , 6517-6529
High-Resolution Dielectric Characterization of Single Cells and Microparticles Using Integrated Microfluidic Microwave Sensors
Microwave sensors can probe intrinsic material properties of analytes in a microfluidic channel at physiologically relevant ion concentrations. While microwave sensors have been used to detect single cells and microparticles in earlier studies, the synergistic use and comparative analysis of microwave sensors with optical microscopy for material classification and size tracking applications have been scarcely investigated so far. Here we combined microwave and optical sensing to differentiate microscale objects based on their dielectric properties. We designed and fabricated two types of planar sensor: a Coplanar Waveguide Resonator (CPW) and a Split-Ring Resonator (SRR). Both sensors possessed sensing electrodes with a narrow gap to detect single cells passing through a microfluidic channel integrated on the same chip. We also show that standalone microwave sensors can track the relative changes in cellular size in real-time. In sensing single 20-micron diameter polystyrene particles, Signal-to-Noise ratio values of approximately 100 for CPW and 70 for SRR sensors were obtained. These findings demonstrate that microwave sensing technology can serve as a complementary technique for single-cell biophysical experiments and microscale pollutant screening.
- 25 November 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (4) , 714-726
Leveraging the elastic deformability of polydimethylsiloxane microfluidic channels for efficient intracellular delivery
Controllable constrictions in PDMS microchannels were achieved by applying external mechanical force to facilitate cell membrane permeation and intracellular delivery.
- 25 November 2022
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 23 (4) , 714-726
Leveraging the elastic deformability of polydimethylsiloxane microfluidic channels for efficient intracellular delivery
Controllable constrictions in PDMS microchannels were achieved by applying external mechanical force to facilitate cell membrane permeation and intracellular delivery.
- Open Access
Leveraging the Elastic Deformability of Polydimethylsiloxane Microfluidic Channels for Efficient Intracellular Delivery
With the rapid development of microfluidic based cell therapeutics systems, the need arises for compact, modular, and microfluidics-compatible intracellular delivery platforms with small footprints and minimal operational requirements. Physical deformation of cells passing through a constriction in a microfluidic channel has been shown to create transient membrane perturbations that allow passive diffusion of materials from the outside to the interior of the cell. This mechanical approach to intracellular delivery is simple to implement and fits the criteria outlined above. However, available microfluidic platforms that operate through this mechanism are traditionally constructed from rigid channels with fixed dimensions that suffer from irreversible clogging and incompatibility with larger size distributions of cells. Here we report a flexible and elastically deformable microfluidic channel, and we leverage this elasticity to dynamically generate temporary constrictions with any given size within the channel width parameters. Additionally, clogging is prevented by increasing the size of the constriction to allow clogs to pass. By tuning the size of the constriction appropriately, we show the successful delivery of GFP-coding plasmids to the interior of three mammalian cell lines and fluorescent gold nanoparticles to HEK293 FT cells all while maintaining a high cell viability rate. This development will no doubt lead to miniaturized intracellular delivery microfluidic components that can be easily integrated into larger lab-on-a-chip systems in future cell modification devices.
Open AccessLeveraging the Elastic Deformability of Polydimethylsiloxane Microfluidic Channels for Efficient Intracellular Delivery
With the rapid development of microfluidic based cell therapeutics systems, the need arises for compact, modular, and microfluidics-compatible intracellular delivery platforms with small footprints and minimal operational requirements. Physical deformation of cells passing through a constriction in a microfluidic channel has been shown to create transient membrane perturbations that allow passive diffusion of materials from the outside to the interior of the cell. This mechanical approach to intracellular delivery is simple to implement and fits the criteria outlined above. However, available microfluidic platforms that operate through this mechanism are traditionally constructed from rigid channels with fixed dimensions that suffer from irreversible clogging and incompatibility with larger size distributions of cells. Here we report a flexible and elastically deformable microfluidic channel, and we leverage this elasticity to dynamically generate temporary constrictions with any given size within the channel width parameters. Additionally, clogging is prevented by increasing the size of the constriction to allow clogs to pass. By tuning the size of the constriction appropriately, we show the successful delivery of GFP-coding plasmids to the interior of three mammalian cell lines and fluorescent gold nanoparticles to HEK293 FT cells all while maintaining a high cell viability rate. This development will no doubt lead to miniaturized intracellular delivery microfluidic components that can be easily integrated into larger lab-on-a-chip systems in future cell modification devices.
- 4 January 2022
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 16 (3) , 3821-3833
Atmospheric Pressure Mass Spectrometry of Single Viruses and Nanoparticles by Nanoelectromechanical Systems
Mass spectrometry of intact nanoparticles and viruses can serve as a potent characterization tool for material science and biophysics. Inaccessible by widespread commercial techniques, the mass of single nanoparticles and viruses (>10MDa) can be readily measured by nanoelectromechanical systems (NEMS)-based mass spectrometry, where charged and isolated analyte particles are generated by electrospray ionization (ESI) in air and transported onto the NEMS resonator for capture and detection. However, the applicability of NEMS as a practical solution is hindered by their miniscule surface area, which results in poor limit-of-detection and low capture efficiency values. Another hindrance is the necessity to house the NEMS inside complex vacuum systems, which is required in part to focus analytes toward the miniscule detection surface of the NEMS. Here, we overcome both limitations by integrating an ion lens onto the NEMS chip. The ion lens is composed of a polymer layer, which charges up by receiving part of the ions incoming from the ESI tip and consequently starts to focus the analytes toward an open window aligned with the active area of the NEMS electrostatically. With this integrated system, we have detected the mass of gold and polystyrene nanoparticles under ambient conditions and with two orders-of-magnitude improvement in capture efficiency compared to the state-of-the-art. We then applied this technology to obtain the mass spectrum of SARS-CoV-2 and BoHV-1 virions. With the increase in analytical throughput, the simplicity of the overall setup, and the operation capability under ambient conditions, the technique demonstrates that NEMS mass spectrometry can be deployed for mass detection of engineered nanoparticles and biological samples efficiently.
- 4 January 2022
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 16 (3) , 3821-3833
Atmospheric Pressure Mass Spectrometry of Single Viruses and Nanoparticles by Nanoelectromechanical Systems
Mass spectrometry of intact nanoparticles and viruses can serve as a potent characterization tool for material science and biophysics. Inaccessible by widespread commercial techniques, the mass of single nanoparticles and viruses (>10MDa) can be readily measured by nanoelectromechanical systems (NEMS)-based mass spectrometry, where charged and isolated analyte particles are generated by electrospray ionization (ESI) in air and transported onto the NEMS resonator for capture and detection. However, the applicability of NEMS as a practical solution is hindered by their miniscule surface area, which results in poor limit-of-detection and low capture efficiency values. Another hindrance is the necessity to house the NEMS inside complex vacuum systems, which is required in part to focus analytes toward the miniscule detection surface of the NEMS. Here, we overcome both limitations by integrating an ion lens onto the NEMS chip. The ion lens is composed of a polymer layer, which charges up by receiving part of the ions incoming from the ESI tip and consequently starts to focus the analytes toward an open window aligned with the active area of the NEMS electrostatically. With this integrated system, we have detected the mass of gold and polystyrene nanoparticles under ambient conditions and with two orders-of-magnitude improvement in capture efficiency compared to the state-of-the-art. We then applied this technology to obtain the mass spectrum of SARS-CoV-2 and BoHV-1 virions. With the increase in analytical throughput, the simplicity of the overall setup, and the operation capability under ambient conditions, the technique demonstrates that NEMS mass spectrometry can be deployed for mass detection of engineered nanoparticles and biological samples efficiently.
- 1 July 2021
- Published by Elsevier in Progress in Materials Science
- Vol. 120
Reprint of: A MACEing silicon: Towards single-step etching of defined porous nanostructures for biomedicine
- 1 July 2021
- Published by Elsevier in Progress in Materials Science
- Vol. 120
Reprint of: A MACEing silicon: Towards single-step etching of defined porous nanostructures for biomedicine
- 1 February 2021
- Published by Elsevier in Progress in Materials Science
- Vol. 116
A MACEing silicon: Towards single-step etching of defined porous nanostructures for biomedicine
- 1 February 2021
- Published by Elsevier in Progress in Materials Science
- Vol. 116
A MACEing silicon: Towards single-step etching of defined porous nanostructures for biomedicine
- 8 September 2016
- Published by Wiley in ChemInform
- Vol. 47 (39)
ChemInform Abstract: Antibacterial Properties of Silver Dendrite Decorated Silicon Nanowires.
Silicon nanowires decorated with silver dendrites are prepared by etching Si wafers with aqueous solutions of HF and AgNO3 (25 °C, 30—90 min).
- 8 September 2016
- Published by Wiley in ChemInform
- Vol. 47 (39)
ChemInform Abstract: Antibacterial Properties of Silver Dendrite Decorated Silicon Nanowires.
Silicon nanowires decorated with silver dendrites are prepared by etching Si wafers with aqueous solutions of HF and AgNO3 (25 °C, 30—90 min).