Agnès Tixier-Mita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Agnès Tixier-Mita has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Hiroshi Toshiyoshi
Institute of Industrial Science, The University of Tokyo
5 shared publicationsSatoshi Ihida
Institute of Industrial Science, The University of Tokyo, Tokyo, Japan
4 shared publications- Hiroshi Toshiyoshi
The University of Tokyo
3 shared publications Katsuhito Fujiu
The University of Tokyo
3 shared publications- Anne-Claire Eiler
The University of Tokyo
2 shared publications Junichi Sugita
The University of Tokyo
2 shared publications
Latest Publications
- 22 July 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (4) , 045036
Unsupervised machine learning-assisted multimodal characterization of cardiomyocytes on a thin-film-transistor microelectrode array (TFT-MEA)
Microelectrode arrays (MEAs) provide powerful platforms for large-scale in vitro cardiac tissue analysis. We present a machine learning (ML)-assisted framework for multimodal characterization of cardiomyocyte activity recorded using a transparent thin-film-transistor MEA, allowing simultaneous acquisition of electrophysiological and optical data. The features of both modalities were integrated, and unsupervised learning identified contraction patterns without prior labels. Reliability was assessed with supervised models and SHapley Additive Explanations to confirm feature importance and label consistency. Pharmacological validation with isoprenaline showed the expected increase in beating frequency, detected automatically by our pipeline. Multimodal feature correlations with emergent labels demonstrated that interpretable ML can extract biologically meaningful insights from complex datasets. While isoprenaline served as a proof-of-concept, the framework is applicable for detecting diverse drug- or disease-induced cardiac network changes. This approach enables scalable, label-free and automated assessment of cardiomyocytes networks for drug discovery, toxicity screening, and mechanistic studies.
- 22 July 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (4) , 045036
Unsupervised machine learning-assisted multimodal characterization of cardiomyocytes on a thin-film-transistor microelectrode array (TFT-MEA)
Microelectrode arrays (MEAs) provide powerful platforms for large-scale in vitro cardiac tissue analysis. We present a machine learning (ML)-assisted framework for multimodal characterization of cardiomyocyte activity recorded using a transparent thin-film-transistor MEA, allowing simultaneous acquisition of electrophysiological and optical data. The features of both modalities were integrated, and unsupervised learning identified contraction patterns without prior labels. Reliability was assessed with supervised models and SHapley Additive Explanations to confirm feature importance and label consistency. Pharmacological validation with isoprenaline showed the expected increase in beating frequency, detected automatically by our pipeline. Multimodal feature correlations with emergent labels demonstrated that interpretable ML can extract biologically meaningful insights from complex datasets. While isoprenaline served as a proof-of-concept, the framework is applicable for detecting diverse drug- or disease-induced cardiac network changes. This approach enables scalable, label-free and automated assessment of cardiomyocytes networks for drug discovery, toxicity screening, and mechanistic studies.
- 30 September 2024
- Published by Springer Nature in Artificial Life and Robotics
- Vol. 29 (4) , 473-478
A digital hardware system for real-time biorealistic stimulation on in vitro cardiomyocytes
- 30 September 2024
- Published by Springer Nature in Artificial Life and Robotics
- Vol. 29 (4) , 473-478
A digital hardware system for real-time biorealistic stimulation on in vitro cardiomyocytes
- Open Access
- 29 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 31 (5) , 802-812
Self-Deformable Flexible MEMS Tweezer Composed of Poly(Vinylidene Fluoride)/Ionic Liquid Gel for Electrical Measurements and Soft Gripping
We present a self-deformable flexible tweezer capable of simultaneous mechanical handling and electrical measurements. The tweezer has a soft cantilever with the dimensions 2 mm$\times$ 8 mm$\times$ 75-100$\mu$ m, and undergoes self-deformation. The device is shown to be successfully capable of detecting electrical signals by gently touching the surface and grasping a spherical bead. The device demonstrated the lowest working voltage (1.5 V$_{\text{DC}}$ ), force suitable for soft gripping, and curvature radius of 2 mm, that was one of the smallest values compared to that of similar state-of-the-art devices. The device was fabricated using a unique and highly reliable process that was specifically developed to produce flexible cantilevers with novel ionic polymer-metal composites (IPMCs). The materials used were poly(vinylidene fluoride-co-trifluoroethylene) (PVDF-TrFE) and an ionic liquid (IL). The PVDF-TrFE/IL gel was prepared using acetone as the solvent and the gel was coated with silver nanowires as the electrodes. The actuator with a length of 8 mm and containing 50 wt% IL yielded the largest bending displacement of 7 mm and minimum curvature radius of 2 mm at 1.5 V$_{\text{DC}}$ .2022-0026- 29 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 31 (5) , 802-812
Open AccessSelf-Deformable Flexible MEMS Tweezer Composed of Poly(Vinylidene Fluoride)/Ionic Liquid Gel for Electrical Measurements and Soft Gripping
We present a self-deformable flexible tweezer capable of simultaneous mechanical handling and electrical measurements. The tweezer has a soft cantilever with the dimensions 2 mm$\times$ 8 mm$\times$ 75-100$\mu$ m, and undergoes self-deformation. The device is shown to be successfully capable of detecting electrical signals by gently touching the surface and grasping a spherical bead. The device demonstrated the lowest working voltage (1.5 V$_{\text{DC}}$ ), force suitable for soft gripping, and curvature radius of 2 mm, that was one of the smallest values compared to that of similar state-of-the-art devices. The device was fabricated using a unique and highly reliable process that was specifically developed to produce flexible cantilevers with novel ionic polymer-metal composites (IPMCs). The materials used were poly(vinylidene fluoride-co-trifluoroethylene) (PVDF-TrFE) and an ionic liquid (IL). The PVDF-TrFE/IL gel was prepared using acetone as the solvent and the gel was coated with silver nanowires as the electrodes. The actuator with a length of 8 mm and containing 50 wt% IL yielded the largest bending displacement of 7 mm and minimum curvature radius of 2 mm at 1.5 V$_{\text{DC}}$ .2022-0026 - Open Access
- 21 June 2021
- Published by MDPI AG in Electrochem
- Vol. 2 (2) , 347-389
Developments of the Electroactive Materials for Non-Enzymatic Glucose Sensing and Their Mechanisms
A comprehensive review of the electroactive materials for non-enzymatic glucose sensing and sensing devices has been performed in this work. A general introduction for glucose sensing, a facile electrochemical technique for glucose detection, and explanations of fundamental mechanisms for the electro-oxidation of glucose via the electrochemical technique are conducted. The glucose sensing materials are classified into five major systems: (1) mono-metallic materials, (2) bi-metallic materials, (3) metallic-oxide compounds, (4) metallic-hydroxide materials, and (5) metal-metal derivatives. The performances of various systems within this decade have been compared and explained in terms of sensitivity, linear regime, the limit of detection (LOD), and detection potentials. Some promising materials and practicable methodologies for the further developments of glucose sensors have been proposed. Firstly, the atomic deposition of alloys is expected to enhance the selectivity, which is considered to be lacking in non-enzymatic glucose sensing. Secondly, by using the modification of the hydrophilicity of the metallic-oxides, a promoted current response from the electro-oxidation of glucose is expected. Lastly, by taking the advantage of the redistribution phenomenon of the oxide particles, the usage of the noble metals is foreseen to be reduced.
- 21 June 2021
- Published by MDPI AG in Electrochem
- Vol. 2 (2) , 347-389
Open AccessDevelopments of the Electroactive Materials for Non-Enzymatic Glucose Sensing and Their Mechanisms
A comprehensive review of the electroactive materials for non-enzymatic glucose sensing and sensing devices has been performed in this work. A general introduction for glucose sensing, a facile electrochemical technique for glucose detection, and explanations of fundamental mechanisms for the electro-oxidation of glucose via the electrochemical technique are conducted. The glucose sensing materials are classified into five major systems: (1) mono-metallic materials, (2) bi-metallic materials, (3) metallic-oxide compounds, (4) metallic-hydroxide materials, and (5) metal-metal derivatives. The performances of various systems within this decade have been compared and explained in terms of sensitivity, linear regime, the limit of detection (LOD), and detection potentials. Some promising materials and practicable methodologies for the further developments of glucose sensors have been proposed. Firstly, the atomic deposition of alloys is expected to enhance the selectivity, which is considered to be lacking in non-enzymatic glucose sensing. Secondly, by using the modification of the hydrophilicity of the metallic-oxides, a promoted current response from the electro-oxidation of glucose is expected. Lastly, by taking the advantage of the redistribution phenomenon of the oxide particles, the usage of the noble metals is foreseen to be reduced.
- Open Access
- 22 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 68 (4) , 2041-2048
Application of a Thin-Film Transistor Array for Cellular-Resolution Electrophysiology and Electrochemistry
The constant development and improvement of microelectromechanical systems (MEMS) have been given a great opportunity to develop new reliable microsystems devices for biomedical research. This article presents a locally addressable 2-D arrayed indium-tin oxide microelectrode platform with integrated thin-film transistors (TFTs) for biological and chemical sensing. Microelectrode arrays (MEAs) using TFT have the advantage of being transparent with a high density of microelectrodes on a large surface. In vitro 2-D electrical measurements on 28 parallel-connected lines selected from a 22 500 MEA were successfully performed with heart cells for the first time. Observation of cell contraction was performed simultaneously with an inverted microscope. Voltammetry and amperometry measurements were also demonstrated using the transparent microelectrodes as working electrodes and an integrated Ag/AgCl reference electrode. Due to its unique features, we believe that the TFT platform can provide more understanding of the key communication between heart cells, and large-scale cardiovascular and nervous systems. As a result, the platform offers unique access to versatile lab-on-a-chip devices that integrate many measurement techniques on one chip for the study of cell cultures, tissues, and organoids.
- 22 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 68 (4) , 2041-2048
Open AccessApplication of a Thin-Film Transistor Array for Cellular-Resolution Electrophysiology and Electrochemistry
The constant development and improvement of microelectromechanical systems (MEMS) have been given a great opportunity to develop new reliable microsystems devices for biomedical research. This article presents a locally addressable 2-D arrayed indium-tin oxide microelectrode platform with integrated thin-film transistors (TFTs) for biological and chemical sensing. Microelectrode arrays (MEAs) using TFT have the advantage of being transparent with a high density of microelectrodes on a large surface. In vitro 2-D electrical measurements on 28 parallel-connected lines selected from a 22 500 MEA were successfully performed with heart cells for the first time. Observation of cell contraction was performed simultaneously with an inverted microscope. Voltammetry and amperometry measurements were also demonstrated using the transparent microelectrodes as working electrodes and an integrated Ag/AgCl reference electrode. Due to its unique features, we believe that the TFT platform can provide more understanding of the key communication between heart cells, and large-scale cardiovascular and nervous systems. As a result, the platform offers unique access to versatile lab-on-a-chip devices that integrate many measurement techniques on one chip for the study of cell cultures, tissues, and organoids.
- Open Access
- 22 July 2019
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 14 (9) , 1280-1288
2D Dielectrophoresis using an active matrix array made by thin‐film‐transistor technology
New types of devices made using thin‐film‐transistor (TFT) technology were used in this article for dielectrophoresis purpose with microbeads, yeast cells, and HepG2 cells. That technology allows obtaining centimeter size transparent substrates covered with a large and dense array of 100 µm microelectrodes individually controllable. The purpose of these devices is the development of platforms for various applications on cells and cells culture, like manipulation, sensing, monitoring, or stimulation on the same device. Dielectrophoresis is one of the applications and is a key target for precise patterning and 2D displacement of cells on the device. In this article, 2D results of dielectrophoresis with microbeads and yeast cells and device programming are described. Then, application to mammal HepG2 liver cells shows the possibility of cells patterning with such devices. © 2019 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
- 22 July 2019
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 14 (9) , 1280-1288
Open Access2D Dielectrophoresis using an active matrix array made by thin‐film‐transistor technology
New types of devices made using thin‐film‐transistor (TFT) technology were used in this article for dielectrophoresis purpose with microbeads, yeast cells, and HepG2 cells. That technology allows obtaining centimeter size transparent substrates covered with a large and dense array of 100 µm microelectrodes individually controllable. The purpose of these devices is the development of platforms for various applications on cells and cells culture, like manipulation, sensing, monitoring, or stimulation on the same device. Dielectrophoresis is one of the applications and is a key target for precise patterning and 2D displacement of cells on the device. In this article, 2D results of dielectrophoresis with microbeads and yeast cells and device programming are described. Then, application to mammal HepG2 liver cells shows the possibility of cells patterning with such devices. © 2019 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
- 23 November 2016
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 28 (1) , 1-11
In vitro cyto-biocompatibility study of thin-film transistors substrates using an organotypic culture method
Thin-Film-Transistors Liquid-Crystal Display has become a standard in the field of displays. However, the structure of these devices presents interest not only in that field, but also for biomedical applications. One of the key components, called here TFT substrate, is a glass substrate with a dense and large array of thousands of transparent micro-electrodes that can be considered as a large scale multi-electrode array(s). Multi-electrode array(s) are widely used for in vitro electrical investigations on neurons and brain, allowing excitation, registration, and recording of their activity. However, the range of application of conventional multi-electrode array(s) is usually limited to some tens of cells in a homogeneous cell culture, because of a small area, small number and a low density of the micro-electrodes. TFT substrates do not have these limitations and the authors are currently studying the possibility to use TFT substrates as new tools for in vitro electrical investigation on tissues and organoids. In this respect, experiments to determine the cyto-biocompatibility of TFT substrates with tissues were conducted and are presented in this study. The investigation was performed using an organotypic culture method with explants of brain and liver tissues of chick embryos. The results in term of morphology, cell migration, cell density and adhesion were compared with the results from Thermanox®, a conventional plastic for cell culture, and with polydimethylsiloxane, a hydrophobic silicone. The results with TFT substrates showed similar results as for the Thermanox®, despite the TFT hydrophobicity. TFT substrates have a weak cell adhesion and promote cell migration similarly to Thermanox®. It could be concluded that the TFT substrates are cyto-biocompatible with the two studied organs.
- 23 November 2016
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 28 (1) , 1-11
In vitro cyto-biocompatibility study of thin-film transistors substrates using an organotypic culture method
Thin-Film-Transistors Liquid-Crystal Display has become a standard in the field of displays. However, the structure of these devices presents interest not only in that field, but also for biomedical applications. One of the key components, called here TFT substrate, is a glass substrate with a dense and large array of thousands of transparent micro-electrodes that can be considered as a large scale multi-electrode array(s). Multi-electrode array(s) are widely used for in vitro electrical investigations on neurons and brain, allowing excitation, registration, and recording of their activity. However, the range of application of conventional multi-electrode array(s) is usually limited to some tens of cells in a homogeneous cell culture, because of a small area, small number and a low density of the micro-electrodes. TFT substrates do not have these limitations and the authors are currently studying the possibility to use TFT substrates as new tools for in vitro electrical investigation on tissues and organoids. In this respect, experiments to determine the cyto-biocompatibility of TFT substrates with tissues were conducted and are presented in this study. The investigation was performed using an organotypic culture method with explants of brain and liver tissues of chick embryos. The results in term of morphology, cell migration, cell density and adhesion were compared with the results from Thermanox®, a conventional plastic for cell culture, and with polydimethylsiloxane, a hydrophobic silicone. The results with TFT substrates showed similar results as for the Thermanox®, despite the TFT hydrophobicity. TFT substrates have a weak cell adhesion and promote cell migration similarly to Thermanox®. It could be concluded that the TFT substrates are cyto-biocompatible with the two studied organs.