Martino Alessandrini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Martino Alessandrini has a total of 144 co-authors. Here are the top co-authors by number of shared publications:
- Jan D'Hooge
Department of Cardiovascular sciences, KU Leuven, Leuven, Belgium
13 shared publications - Denis Friboulet
Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, F-69100, LYON, France
12 shared publications O. Bernard
CREATIS, Université Lyon 1, Lyon, France
12 shared publicationsOlivier Bernard
Université de Lyon; CREATIS; CNRS UMR5220; Inserm U1044; INSA-Lyon; Université Lyon 1, Lyon, France
9 shared publications- Herve Liebgott
CNRS, Inserm, CREATIS UMR 5220, INSA-Lyon, Universit Lyon 1, Lyon, France
8 shared publications - Maxime Sermesant
Centre Inria d’Université Côte d’Azur, Epione team, Sophia Antipolis
7 shared publications
Latest Publications
- Open Access
- 1 September 2024
- Published by Walter de Gruyter GmbH in Polish Journal of Medical Physics And Engineering
- Vol. 30 (3) , 161-168
Investigation of the impact of local properties of 3D data on the accuracy of block matching-based speckle tracking echocardiography
Introduction: Due to its simplicity, block-matching is a popular motion-tracking method used in speckle-tracking echocardiography. Improvement of its robustness and accuracy is thus of prime interest. Although it seems plausible that the quality of block matching-based tracking depends on the local properties of image data, and thus, it should be possible to assess in advance how well certain portions of the image data are suited for displacement estimation, the potential relationship has not been studied extensively. Material and methods: This study aimed to search for a relationship between selected features of echocardiographic data and the quality of local displacement estimation. The study used a 3D synthetic B-mode imaging sequence data with known ground truth. Frame-to-frame displacements were estimated for 9856 points in five different frame pairs with mean inter-frame displacements of 0.15, 0.87, 2, 3.02, and 3.84 mm. In each case, tracking errors were evaluated against thirteen grayscale image features, the displacement’s magnitudes, and the normalized cross-correlation (NCX) values. Additionally, a multi-variable regression model was applied to test the combined ability of the proposed features to predict tracking quality. Results: Median tracking error magnitudes were 0.06, 0.13, 0.28, 0.74, and 1.5 mm for each image pair. Weak correlation between errors and individual data features was found only in the case of 3 features: NCX (Pearson’s correlation coefficients in the range of −0.366 to −0.223), number of speckles within the kernel (−0.283, −0.282, and −0.214 for three lowest deformations) and mean of the 3D gradient (−0.252, −0.237 and −0.25). The regression model, however, provided significant prediction improvement with R2 exceeding 0.5. Conclusions: In conclusion, only a weak relationship between the individual investigated kernel features and tracking accuracy has been established, but their combined strength can be assessed as at least moderate.
- 1 September 2024
- Published by Walter de Gruyter GmbH in Polish Journal of Medical Physics And Engineering
- Vol. 30 (3) , 161-168
Open AccessInvestigation of the impact of local properties of 3D data on the accuracy of block matching-based speckle tracking echocardiography
Introduction: Due to its simplicity, block-matching is a popular motion-tracking method used in speckle-tracking echocardiography. Improvement of its robustness and accuracy is thus of prime interest. Although it seems plausible that the quality of block matching-based tracking depends on the local properties of image data, and thus, it should be possible to assess in advance how well certain portions of the image data are suited for displacement estimation, the potential relationship has not been studied extensively. Material and methods: This study aimed to search for a relationship between selected features of echocardiographic data and the quality of local displacement estimation. The study used a 3D synthetic B-mode imaging sequence data with known ground truth. Frame-to-frame displacements were estimated for 9856 points in five different frame pairs with mean inter-frame displacements of 0.15, 0.87, 2, 3.02, and 3.84 mm. In each case, tracking errors were evaluated against thirteen grayscale image features, the displacement’s magnitudes, and the normalized cross-correlation (NCX) values. Additionally, a multi-variable regression model was applied to test the combined ability of the proposed features to predict tracking quality. Results: Median tracking error magnitudes were 0.06, 0.13, 0.28, 0.74, and 1.5 mm for each image pair. Weak correlation between errors and individual data features was found only in the case of 3 features: NCX (Pearson’s correlation coefficients in the range of −0.366 to −0.223), number of speckles within the kernel (−0.283, −0.282, and −0.214 for three lowest deformations) and mean of the 3D gradient (−0.252, −0.237 and −0.25). The regression model, however, provided significant prediction improvement with R2 exceeding 0.5. Conclusions: In conclusion, only a weak relationship between the individual investigated kernel features and tracking accuracy has been established, but their combined strength can be assessed as at least moderate.
- 5 March 2021
- Published by Springer Nature
- p. 552-565
SAFFIRE: System for Autonomous Feature Filtering and Intelligent ROI Estimation
- 5 March 2021
- Published by Springer Nature
- p. 552-565
SAFFIRE: System for Autonomous Feature Filtering and Intelligent ROI Estimation
- 1 October 2019
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 142 (1)
A Proof of Concept for Computational Fluid Dynamic Analysis of the Left Atrium in Atrial Fibrillation on a Patient-Specific Basis
Atrial fibrillation (AF) is associated with a fivefold increase in the risk of cerebrovascular events, being responsible of 15–18% of all strokes. The morphological and functional remodeling of the left atrium (LA) caused by AF favors blood stasis and, consequently, stroke risk. In this context, several clinical studies suggest that the stroke risk stratification could be improved by using hemodynamic information on the LA and the left atrial appendage (LAA). The goal of this study was to develop a personalized computational fluid dynamics (CFD) model of the LA which could clarify the hemodynamic implications of AF on a patient-specific basis. In this paper, we present the developed model and its application to two AF patients as a preliminary advancement toward an optimized stroke risk stratification pipeline.
- 1 October 2019
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 142 (1)
A Proof of Concept for Computational Fluid Dynamic Analysis of the Left Atrium in Atrial Fibrillation on a Patient-Specific Basis
Atrial fibrillation (AF) is associated with a fivefold increase in the risk of cerebrovascular events, being responsible of 15–18% of all strokes. The morphological and functional remodeling of the left atrium (LA) caused by AF favors blood stasis and, consequently, stroke risk. In this context, several clinical studies suggest that the stroke risk stratification could be improved by using hemodynamic information on the LA and the left atrial appendage (LAA). The goal of this study was to develop a personalized computational fluid dynamics (CFD) model of the LA which could clarify the hemodynamic implications of AF on a patient-specific basis. In this paper, we present the developed model and its application to two AF patients as a preliminary advancement toward an optimized stroke risk stratification pipeline.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 22 (2) , 503-515
Statistical Shape Modeling of the Left Ventricle: Myocardial Infarct Classification Challenge
Statistical shape modeling is a powerful tool for visualizing and quantifying geometric and functional patterns of the heart. After myocardial infarction (MI), the left ventricle typically remodels in response to physiological challenges. Several methods have been proposed in the literature to describe statistical shape changes. Which method best characterizes the left ventricular remodeling after MI is an open research question. A better descriptor of remodeling is expected to provide a more accurate evaluation of disease status in MI patients. We therefore designed a challenge to test shape characterization in MI given a set of three-dimensional left ventricular surface points. The training set comprised 100 MI patients, and 100 asymptomatic volunteers (AV). The challenge was initiated in 2015 at the Statistical Atlases and Computational Models of the Heart workshop, in conjunction with the MICCAI conference. The training set with labels was provided to participants, who were asked to submit the likelihood of MI from a different (validation) set of 200 cases (100 AV and 100 MI). Sensitivity, specificity, accuracy, and area under the receiver operating characteristic curve were used as the outcome measures. The goals of this challenge were to 1) establish a common dataset for evaluating statistical shape modeling algorithms in MI, and 2) test whether statistical shape modeling provides additional information characterizing MI patients over standard clinical measures. Eleven groups with a wide variety of classification and feature extraction approaches participated in this challenge. All methods achieved excellent classification results with accuracy ranges from 0.83 to 0.98. The areas under the receiver operating characteristic curves were all above 0.90. Four methods showed significantly higher performance than standard clinical measures. The dataset and software for evaluation are available from the Cardiac Atlas Project website. 11 http://www.cardiacatlas.org.
- 1 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 22 (2) , 503-515
Statistical Shape Modeling of the Left Ventricle: Myocardial Infarct Classification Challenge
Statistical shape modeling is a powerful tool for visualizing and quantifying geometric and functional patterns of the heart. After myocardial infarction (MI), the left ventricle typically remodels in response to physiological challenges. Several methods have been proposed in the literature to describe statistical shape changes. Which method best characterizes the left ventricular remodeling after MI is an open research question. A better descriptor of remodeling is expected to provide a more accurate evaluation of disease status in MI patients. We therefore designed a challenge to test shape characterization in MI given a set of three-dimensional left ventricular surface points. The training set comprised 100 MI patients, and 100 asymptomatic volunteers (AV). The challenge was initiated in 2015 at the Statistical Atlases and Computational Models of the Heart workshop, in conjunction with the MICCAI conference. The training set with labels was provided to participants, who were asked to submit the likelihood of MI from a different (validation) set of 200 cases (100 AV and 100 MI). Sensitivity, specificity, accuracy, and area under the receiver operating characteristic curve were used as the outcome measures. The goals of this challenge were to 1) establish a common dataset for evaluating statistical shape modeling algorithms in MI, and 2) test whether statistical shape modeling provides additional information characterizing MI patients over standard clinical measures. Eleven groups with a wide variety of classification and feature extraction approaches participated in this challenge. All methods achieved excellent classification results with accuracy ranges from 0.83 to 0.98. The areas under the receiver operating characteristic curves were all above 0.90. Four methods showed significantly higher performance than standard clinical measures. The dataset and software for evaluation are available from the Cardiac Atlas Project website. 11 http://www.cardiacatlas.org.
- 22 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 65 (3) , 411-422
Realistic Vendor-Specific Synthetic Ultrasound Data for Quality Assurance of 2-D Speckle Tracking Echocardiography: Simulation Pipeline and Open Access Database
Two dimensional (2D) echocardiography is the modality of choice in the clinic for the diagnosis of cardiac disease. Hereto, speckle tracking (ST) packages complement visual assessment by the cardiologist by providing quantitative diagnostic markers of global and regional cardiac function (e.g. displacement, strain, strain-rate). Yet, the reported high vendordependency between the outputs of different ST packages raises clinical concern and hampers the widespread dissemination of the ST technology. In part, this is due to the lack of a solid commonly accepted quality assurance pipeline for ST packages. Recently, we have developed a framework to benchmark ST algorithms for three dimensional (3D) echocardiography by using realistic simulated volumetric echocardiographic recordings. Yet, 3D echocardiography remains an emerging technology while the compelling clinical concern is, so far, directed to the standardization of 2D ST only. By building upon our previous work, we present therefore in this paper a pipeline to generate realistic synthetic sequences for 2D ST algorithms. Hereto, the synthetic cardiac motion is obtained from a complex electro-mechanical heart model while realistic vendor-specific texture is obtained by sampling a real clinical ultrasound recording. By modifying the parameters in our pipeline, we generated an open access library of 105 synthetic sequences encompassing i) healthy and ischemic motion patterns, ii) most common apical probe orientations iii) vendor specific image quality from 7 different systems. Ground truth deformation is also provided to allow performance analysis. The application of the provided data-set is also demonstrated in the bench-marking of a recent academic ST algorithm.
- 22 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 65 (3) , 411-422
Realistic Vendor-Specific Synthetic Ultrasound Data for Quality Assurance of 2-D Speckle Tracking Echocardiography: Simulation Pipeline and Open Access Database
Two dimensional (2D) echocardiography is the modality of choice in the clinic for the diagnosis of cardiac disease. Hereto, speckle tracking (ST) packages complement visual assessment by the cardiologist by providing quantitative diagnostic markers of global and regional cardiac function (e.g. displacement, strain, strain-rate). Yet, the reported high vendordependency between the outputs of different ST packages raises clinical concern and hampers the widespread dissemination of the ST technology. In part, this is due to the lack of a solid commonly accepted quality assurance pipeline for ST packages. Recently, we have developed a framework to benchmark ST algorithms for three dimensional (3D) echocardiography by using realistic simulated volumetric echocardiographic recordings. Yet, 3D echocardiography remains an emerging technology while the compelling clinical concern is, so far, directed to the standardization of 2D ST only. By building upon our previous work, we present therefore in this paper a pipeline to generate realistic synthetic sequences for 2D ST algorithms. Hereto, the synthetic cardiac motion is obtained from a complex electro-mechanical heart model while realistic vendor-specific texture is obtained by sampling a real clinical ultrasound recording. By modifying the parameters in our pipeline, we generated an open access library of 105 synthetic sequences encompassing i) healthy and ischemic motion patterns, ii) most common apical probe orientations iii) vendor specific image quality from 7 different systems. Ground truth deformation is also provided to allow performance analysis. The application of the provided data-set is also demonstrated in the bench-marking of a recent academic ST algorithm.
- 3 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 35 (8) , 1915-1926
Detailed Evaluation of Five 3D Speckle Tracking Algorithms Using Synthetic Echocardiographic Recordings
A plethora of techniques for cardiac deformation imaging with 3D ultrasound, typically referred to as 3D speckle tracking techniques, are available from academia and industry. Although the benefits of single methods over alternative ones have been reported in separate publications, the intrinsic differences in the data and definitions used makes it hard to compare the relative performance of different solutions. To address this issue, we have recently proposed a framework to simulate realistic 3D echocardiographic recordings and used it to generate a common set of ground-truth data for 3D speckle tracking algorithms, which was made available online. The aim of this study was therefore to use the newly developed database to contrast non-commercial speckle tracking solutions from research groups with leading expertise in the field. The five techniques involved cover the most representative families of existing approaches, namely block-matching, radio-frequency tracking, optical flow and elastic image registration. The techniques were contrasted in terms of tracking and strain accuracy. The feasibility of the obtained strain measurements to diagnose pathology was also tested for ischemia and dyssynchrony.
- 3 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 35 (8) , 1915-1926
Detailed Evaluation of Five 3D Speckle Tracking Algorithms Using Synthetic Echocardiographic Recordings
A plethora of techniques for cardiac deformation imaging with 3D ultrasound, typically referred to as 3D speckle tracking techniques, are available from academia and industry. Although the benefits of single methods over alternative ones have been reported in separate publications, the intrinsic differences in the data and definitions used makes it hard to compare the relative performance of different solutions. To address this issue, we have recently proposed a framework to simulate realistic 3D echocardiographic recordings and used it to generate a common set of ground-truth data for 3D speckle tracking algorithms, which was made available online. The aim of this study was therefore to use the newly developed database to contrast non-commercial speckle tracking solutions from research groups with leading expertise in the field. The five techniques involved cover the most representative families of existing approaches, namely block-matching, radio-frequency tracking, optical flow and elastic image registration. The techniques were contrasted in terms of tracking and strain accuracy. The feasibility of the obtained strain measurements to diagnose pathology was also tested for ischemia and dyssynchrony.
- Open Access
- 5 October 2015
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 48 (1) , 98-105
Semi-automatic outlining of levator hiatus
- 5 October 2015
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 48 (1) , 98-105
Open AccessSemi-automatic outlining of levator hiatus
- 27 January 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 34 (7) , 1436-1451
A Pipeline for the Generation of Realistic 3D Synthetic Echocardiographic Sequences: Methodology and Open-Access Database
Quantification of cardiac deformation and strain with 3D ultrasound takes considerable research efforts. Nevertheless, a widespread use of these techniques in clinical practice is still held back due to the lack of a solid verification process to quantify and compare performance. In this context, the use of fully synthetic sequences has become an established tool for initial in silico evaluation. Nevertheless, the realism of existing simulation techniques is still too limited to represent reliable benchmarking data. Moreover, the fact that different centers typically make use of in-house developed simulation pipelines makes a fair comparison difficult. In this context, this paper introduces a novel pipeline for the generation of synthetic 3D cardiac ultrasound image sequences. State-of-the art solutions in the fields of electromechanical modeling and ultrasound simulation are combined within an original framework that exploits a real ultrasound recording to learn and simulate realistic speckle textures. The simulated images show typical artifacts that make motion tracking in ultrasound challenging. The ground-truth displacement field is available voxelwise and is fully controlled by the electromechanical model. By progressively modifying mechanical and ultrasound parameters, the sensitivity of 3D strain algorithms to pathology and image properties can be evaluated. The proposed pipeline is used to generate an initial library of 8 sequences including healthy and pathological cases, which is made freely accessible to the research community via our project web-page.
- 27 January 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 34 (7) , 1436-1451
A Pipeline for the Generation of Realistic 3D Synthetic Echocardiographic Sequences: Methodology and Open-Access Database
Quantification of cardiac deformation and strain with 3D ultrasound takes considerable research efforts. Nevertheless, a widespread use of these techniques in clinical practice is still held back due to the lack of a solid verification process to quantify and compare performance. In this context, the use of fully synthetic sequences has become an established tool for initial in silico evaluation. Nevertheless, the realism of existing simulation techniques is still too limited to represent reliable benchmarking data. Moreover, the fact that different centers typically make use of in-house developed simulation pipelines makes a fair comparison difficult. In this context, this paper introduces a novel pipeline for the generation of synthetic 3D cardiac ultrasound image sequences. State-of-the art solutions in the fields of electromechanical modeling and ultrasound simulation are combined within an original framework that exploits a real ultrasound recording to learn and simulate realistic speckle textures. The simulated images show typical artifacts that make motion tracking in ultrasound challenging. The ground-truth displacement field is available voxelwise and is fully controlled by the electromechanical model. By progressively modifying mechanical and ultrasound parameters, the sensitivity of 3D strain algorithms to pathology and image properties can be evaluated. The proposed pipeline is used to generate an initial library of 8 sequences including healthy and pathological cases, which is made freely accessible to the research community via our project web-page.