Mattia Beretta

Mattia Beretta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mattia Beretta has a total of 177 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

    by M. Adamič, M. Beretta, J. Camilleri, C. Capelli, M.A. Dobbs, T. Elleflot, B.K. Fujikawa, Yu.G. Kolomensky, D. Mayer, J. Montgomery, et al.

    The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

  • Open Access

    Improving the performance of cryogenic calorimeters with nonlinear multivariate noise cancellation algorithms

    by K. J. Vetter, M. Beretta, C. Capelli, F. Del Corso, E. V. Hansen, R. G. Huang, Yu. G. Kolomensky, L. Marini, I. Nutini, V. Singh, et al.

    State-of-the-art physics experiments require high-resolution, low-noise, and low-threshold detectors to achieve competitive scientific results. However, experimental environments invariably introduce sources of noise, such as electrical interference or microphonics. The sources of this environmental noise can often be monitored by adding specially designed “auxiliary devices” (e.g. microphones, accelerometers, seismometers, magnetometers, and antennae). A model can then be constructed to predict the detector noise based on the auxiliary device information, which can then be subtracted from the true detector signal. Here, we present a multivariate noise cancellation algorithm which can be used in a variety of settings to improve the performance of detectors using multiple auxiliary devices. To validate this approach, we apply it to simulated data to remove noise due to electromagnetic interference and microphonic vibrations. We then employ the algorithm to a cryogenic light detector in the laboratory and show an improvement in the detector performance. Finally, we motivate the use of nonlinear terms to better model vibrational contributions to the noise in thermal detectors. We show a further improvement in the performance of a particular channel of the CUORE detector when using the nonlinear algorithm in combination with optimal filtering techniques.


  • Open Access

    Measurement of 216Po half-life with the CUPID-0 experiment

    by O. Azzolini, J.W. Beeman, F. Bellini, M. Beretta, M. Biassoni, C. Brofferio, C. Bucci, S. Capelli, L. Cardani, P. Carniti, et al.


  • Open Access

    Measurement of $^{216}$Po half-life with the CUPID-0 experiment

    by O. Azzolini, J. W. Beeman, F. Bellini, M. Beretta, M. Biassoni, C. Brofferio, C. Bucci, S. Capelli, L. Cardani, P. Carniti, et al.

    Rare event physics demands very detailed background control, high-performance detectors, and custom analysis strategies. Cryogenic calorimeters combine all these ingredients very effectively, representing a promising tool for next-generation experiments. CUPID-0 is one of the most advanced examples of such a technique, having demonstrated its potential with several results obtained with limited exposure. In this paper, we present a further application. Exploiting the analysis of delayed coincidence, we can identify the signals caused by the $^{220}$Rn-$^{216}$Po decay sequence on an event-by-event basis. The analysis of these events allows us to extract the time differences between the two decays, leading to a new evaluation of $^{216}$ half-life, estimated as (143.3 $\pm$ 2.8) ms.

  • Open Access

    Development of Cryogenic Detectors for Neutrinoless Double Beta Decay Searches with CUORE and CUPID

    by Mattia Beretta, Lorenzo Pagnanini

    Searching for neutrinoless double beta decay is a top priority in particle and astroparticle physics, being the most sensitive test of lepton number violation and the only suitable process to probe the Majorana nature of neutrinos. In order to increase the experimental sensitivity for this particular search, ton-scale detectors operated at nearly zero-background conditions with a low keV energy resolution at the expected signal peak are required. In this scenario, cryogenic detectors have been proven effective in addressing many of these issues simultaneously. After long technical developments, the Cryogenic Underground Observatory for Rare Events (CUORE) experiment established the possibility to operate large-scale detectors based on this technology. Parallel studies pointed out that scintillating cryogenic detectors represent a suitable upgrade for the CUORE design, directed towards higher sensitivities. In this work, we review the recent development of cryogenic detectors, starting from the state-of-the-art and outlying the path toward next-generation experiments.


  • Open Access

    Search for double $\beta $-decay modes of $^{64}$Zn using purified zinc

    by F. Bellini, M. Beretta, L. Cardani, P. Carniti, N. Casali, E. Celi, D. Chiesa, M. Clemenza, I. Dafinei, S. Di Domizio, et al.

    The production of ultra-pure raw material is a crucial step to ensure the required background level in rare event searches. In this work, we establish an innovative technique developed to produce high-purity (99.999%) granular zinc. We demonstrate the effectiveness of the refining procedure by measuring the internal contaminations of the purified zinc with a high-purity germanium detector at the Laboratori Nazionali del Gran Sasso. The total activity of cosmogenic activated nuclides is measured at the level of a few mBq/kg, as well as limits on naturally occurring radionuclides are set to less than mBq/kg. The excellent radiopurity of the zinc sample allows us to search for electron capture with positron emission and neutrinoless double electron capture of $$^{64}$$ 64 Zn, setting the currently most stringent lower limits on their half-lives, $$T_{1/2}^{\varepsilon \beta ^+} > 2.7\times 10^{21}~\text {year}$$ T 1 / 2 ε β + > 2.7 × 10 21 year (90% CI), and $$T_{1/2}^{0\nu 2\varepsilon }> 2.6\times 10^{21}~\text {year}$$ T 1 / 2 0 ν 2 ε > 2.6 × 10 21 year (90% CI), respectively.


  • Open Access

    Development of Cryogenic Detectors for Neutrinoless Double Beta Decay Searches

    by Mattia Beretta, Lorenzo Pagnanini

    Searching for neutrinoless double beta decay is a top priority in particle and astroparticle physics, being the most sensitive test of lepton number violation and the only suitable process to probe the Majorana nature of neutrinos. In order to increase the experimental sensitivity for this particular search, ton-scale detectors operated at nearly zero-background conditions with a few keV energy resolution are required. In this scenario, cryogenic detectors have proven effective in addressing many of these issues simultaneously. After long technical developments, the CUORE experiment established the possibility to operate large scale detectors based on this technology. Parallel studies pointed out that scintillating cryogenic detectors represent a suitable upgrade for the CUORE design, directed towards higher sensitivities. In this work, we review the recent development of cryogenic detectors, starting from the status of the art and outlying the path toward next-generation experiments.


  • Monte Carlo simulation of particle detector data stream

    by M. Beretta, M. Biassoni, L. Gironi, M. Maino, M. Nastasi, L. Pagnanini, S. Pozzi


  • Efficient, fast and reabsorption-free perovskite nanocrystal-based sensitized plastic scintillators

    by Marina Gandini, Irene Villa, Mattia Beretta, Claudio Gotti, Muhammad Imran, Francesco Carulli, Eric Fantuzzi, Mauro Sassi, Matteo Zaffalon, Chiara Brofferio, et al.

    The urgency for affordable and reliable detectors for ionizing radiation in medical diagnostics, nuclear control and particle physics is generating growing demand for scintillator devices combining efficient scintillation, fast emission lifetime, high interaction probability with ionizing radiation and mitigated reabsorption losses in large-volume/high-density detectors. To date, the simultaneous achievement of all such features is still an open challenge. Here we realize this regime with poly(methyl methacrylate) nanocomposites embedding CsPbBr3 perovskite nanocrystals as sensitizers for a conjugated organic dye featuring a large Stokes shift and a fast emission lifetime in the red spectral region. Complete energy transfer from the nanocrystals to the dye under both X-rays and α-particle excitation results in highly stable radioluminescence with an efficiency comparable to that of commercial-grade inorganic and plastic scintillators; an ~3.4 ns emission lifetime, competitive with fast lanthanide scintillators; and reabsorption-free waveguiding for long optical distances.