A. Nuri Ozcivan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
A. Nuri Ozcivan has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
M. Tsuda
Tohoku University
5 shared publicationsT. Hamajima
Tohoku University
5 shared publicationsN. Hu
Tohoku University
4 shared publicationsT. Yagai
Tohoku University
4 shared publicationsM. Toda
Tohoku University
3 shared publicationsS. Soeda
Graduate School of Engineering, Department of Electrical and Communications Engineering, Tohoku University, 6-6-05 Aramakiaza Aoba, Aoba-ku, Sendai-shi, Miyagi-ken 980-8579, Japan
3 shared publications
Latest Publications
- Open Access
- 25 January 2011
- Published by Wiley in Electronics and Communications in Japan
- Vol. 94 (2) , 51-58
Balanced three‐phase distribution experiment of a triaxial HTS cable
- 25 January 2011
- Published by Wiley in Electronics and Communications in Japan
- Vol. 94 (2) , 51-58
Open AccessBalanced three‐phase distribution experiment of a triaxial HTS cable
- 25 September 2010
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 24 (1-2) , 975-980
AC Loss of a Multi-Layer per Phase Tri-Axial HTS Cable with Balanced Current Distribution
- 25 September 2010
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 24 (1-2) , 975-980
AC Loss of a Multi-Layer per Phase Tri-Axial HTS Cable with Balanced Current Distribution
- 16 May 2010
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 470 (20) , 1584-1587
Design of HTS tri-axial cable in steady-state operation
- 16 May 2010
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 470 (20) , 1584-1587
Design of HTS tri-axial cable in steady-state operation
- 29 March 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 20 (3) , 1288-1291
Fault Current Analysis in a Tri-Axial HTS Cable
Tri-axial cable has been rapidly developed recently because of the advantages such as more compact structure, small leakage field, and low heat and AC losses. One the other hand, it causes an inherent imbalanced three-phase currents distribution due to the different radii of concentric layers. In our previous research, it is demonstrated that a proposed tri-axial cable composed of two longitudinal sections with adjusted twist pitches can transmit balanced three-phase currents. However, before the cable can be installed in a real grid, the heat reliability of the cable in steady-state operation and fault condition should be ensured. The heat balance calculation of the tri-axial cable in steady state under the balanced current distribution allows us to estimate thermal parameters of the cable such as inlet and outlet temperatures, pressure drop and operation temperature. When a phase current suddenly changes under fault conditions, the remaining phase currents become large because of mutual inductances between fault and sound phases. Simulation of the typical fault suggests the copper stabilizer amount on the HTS tape for stability and safety. It is found that copper of 2 mm in thickness keeps the cable temperature under 110 K.
- 29 March 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 20 (3) , 1288-1291
Fault Current Analysis in a Tri-Axial HTS Cable
Tri-axial cable has been rapidly developed recently because of the advantages such as more compact structure, small leakage field, and low heat and AC losses. One the other hand, it causes an inherent imbalanced three-phase currents distribution due to the different radii of concentric layers. In our previous research, it is demonstrated that a proposed tri-axial cable composed of two longitudinal sections with adjusted twist pitches can transmit balanced three-phase currents. However, before the cable can be installed in a real grid, the heat reliability of the cable in steady-state operation and fault condition should be ensured. The heat balance calculation of the tri-axial cable in steady state under the balanced current distribution allows us to estimate thermal parameters of the cable such as inlet and outlet temperatures, pressure drop and operation temperature. When a phase current suddenly changes under fault conditions, the remaining phase currents become large because of mutual inductances between fault and sound phases. Simulation of the typical fault suggests the copper stabilizer amount on the HTS tape for stability and safety. It is found that copper of 2 mm in thickness keeps the cable temperature under 110 K.
- 12 September 2009
- Published by Elsevier in Cryogenics
- Vol. 49 (12) , 714-718
Investigation on AC loss of a high temperature superconducting tri-axial cable depending on twist pitches
- 12 September 2009
- Published by Elsevier in Cryogenics
- Vol. 49 (12) , 714-718
Investigation on AC loss of a high temperature superconducting tri-axial cable depending on twist pitches
- 1 August 2009
- Published by Elsevier in Cryogenics
- Vol. 49 (8) , 398-401
Experimental results of tri-axial HTS cable
- 1 August 2009
- Published by Elsevier in Cryogenics
- Vol. 49 (8) , 398-401
Experimental results of tri-axial HTS cable
- 23 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 19 (3) , 1748-1751
Balanced Three-Phase Distributions of Tri-Axial Cable for Transmission Line
High Temperature Superconducting (HTS) cables have been intensively developed because of low loss and compactness, compared with conventional copper cables. A tri-axial cable composed of three concentric phases has been studied, because it has advantages such as reduced amount of HTS tapes and low heat-in-leak, compared with the three single-phase cables. However, there is an inherent imbalance in the three-phase distribution in the tri-axial cable due to differences in radii of the three-phase layers. We proposed a theory to obtain the balanced three-phase distribution for the tri-axial cable by treating two longitudinal cable sections together and adjusting all twist pitches. We derived a generalized formula as functions of winding pitches satisfying the balanced distribution. We designed and fabricated a short HTS tri-axial cable composed of 1 layer/phase to verify the proposed theory. The test results demonstrated that the theory is right for an equivalent impedance circuit model. The theory should be applied to the unbalanced three phase distributions caused by fabrication errors and inherent imbalance of capacitances in the tri-axial cable. We calculate the unbalanced three phase currents and voltages in steady state, and resolve them into symmetrical components to evaluate an imbalance ratio, which is defined as zero-sequence or negative-sequence to positive-sequence component. It is found that the fabrication errors of twist pitch and radius cause the imbalance ratios less than 1%, and the unbalanced capacitances of the cable of 10 km in length cause imbalance ratios of about 1%.
- 23 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 19 (3) , 1748-1751
Balanced Three-Phase Distributions of Tri-Axial Cable for Transmission Line
High Temperature Superconducting (HTS) cables have been intensively developed because of low loss and compactness, compared with conventional copper cables. A tri-axial cable composed of three concentric phases has been studied, because it has advantages such as reduced amount of HTS tapes and low heat-in-leak, compared with the three single-phase cables. However, there is an inherent imbalance in the three-phase distribution in the tri-axial cable due to differences in radii of the three-phase layers. We proposed a theory to obtain the balanced three-phase distribution for the tri-axial cable by treating two longitudinal cable sections together and adjusting all twist pitches. We derived a generalized formula as functions of winding pitches satisfying the balanced distribution. We designed and fabricated a short HTS tri-axial cable composed of 1 layer/phase to verify the proposed theory. The test results demonstrated that the theory is right for an equivalent impedance circuit model. The theory should be applied to the unbalanced three phase distributions caused by fabrication errors and inherent imbalance of capacitances in the tri-axial cable. We calculate the unbalanced three phase currents and voltages in steady state, and resolve them into symmetrical components to evaluate an imbalance ratio, which is defined as zero-sequence or negative-sequence to positive-sequence component. It is found that the fabrication errors of twist pitch and radius cause the imbalance ratios less than 1%, and the unbalanced capacitances of the cable of 10 km in length cause imbalance ratios of about 1%.
- 1 September 2008
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 468 (15-20) , 2033-2036
AC loss in a tri-axial HTS cable with balanced current distribution
- 1 September 2008
- Published by Elsevier in Physica C: Superconductivity and its Applications
- Vol. 468 (15-20) , 2033-2036
AC loss in a tri-axial HTS cable with balanced current distribution
- 1 February 2008
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 97
AC losses of a tri-axial superconducting cable with balanced three-phase current distributions
- 1 February 2008
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 97
AC losses of a tri-axial superconducting cable with balanced three-phase current distributions