JCJasamine Coles-Black

Jasamine Coles-Black

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jasamine Coles-Black has a total of 83 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Stereotactic Body Therapy for Urologic Cancers—What the Urologist Needs to Know

    by Jasamine Coles-Black, Adib Rahman, Shankar Siva, Joseph Ischia, Marlon Perera, Damien Bolton, Nathan Lawrentschuk

    Background: stereotactic ablative body radiotherapy (SABR) is a disruptive radiation therapy technique which is increasingly used for the treatment of urologic cancers. The aim of this narrative review is to provide an overview on the current landscape of SABR in urologic cancers and highlight advancements on the horizon. Methods: a narrative review of the contemporary role of SABR in urologic cancers is conducted. Results: in localised prostate cancer, SABR boasts excellent tumour control and biochemical control, with acceptable GU and GI toxicity. Its comparison to laparoscopic radical prostatectomy is currently ongoing. SABR appears to be practical for metastasis-directed therapy in metastatic prostate cancer, with good local control and a low toxicity profile, either alone or in combination with ADT. In localised RCC, SABR offers adequate local control with a modest impact on renal function in patients unfit for surgical management. Its role in metastatic RCC is much more established, where it has been shown to be superior to conventional radiotherapy. Emerging evidence suggests that SABR has a role in delaying systemic therapy whilst maintaining QOL and overall survival. Intriguingly, in metastatic prostate cancer and metastatic RCC, SABR results in a cytoreductive and immunomodulatory ‘abscopal effect’, a focus of current investigations. Conclusions: SABR has emerged as a safe, effective, and feasible treatment for urologic cancers. Urologists should be aware of its increasing use in localised prostate cancer and metastatic RCC, with good oncological outcomes combined with acceptable toxicity. In addition, SABR holds promise for both metastatic prostate cancer and localised RCC treatment in terms of toxicity and oncological outcomes.

  • Open Access

    ChatGPT and generative AI in urology and surgery—A narrative review

    by Shane Qin, Bodie Chislett, Joseph Ischia, Weranja Ranasinghe, Daswin de Silva, Jasamine Coles‐Black, Dixon Woon, Damien Bolton

    Introduction: ChatGPT (generative pre‐trained transformer [GPT]), developed by OpenAI, is a type of generative artificial intelligence (AI) that has been widely utilised since its public release. It orchestrates an advanced conversational intelligence, producing sophisticated responses to questions. ChatGPT has been successfully demonstrated across several applications in healthcare, including patient management, academic research and clinical trials. We aim to evaluate the different ways ChatGPT has been utilised in urology and more broadly in surgery.Methods: We conducted a literature search of the PubMed and Embase electronic databases for the purpose of writing a narrative review and identified relevant articles on ChatGPT in surgery from the years 2000 to 2023. A PRISMA flow chart was created to highlight the article selection process. The search terms ‘ChatGPT’ and ‘surgery’ were intentionally kept broad given the nascency of the field. Studies unrelated to these terms were excluded. Duplicates were removed.Results: Multiple papers have been published about novel uses of ChatGPT in surgery, ranging from assisting in administrative tasks including answering frequently asked questions, surgical consent, writing operation reports, discharge summaries, grants, journal article drafts, reviewing journal articles and medical education. AI and machine learning has also been extensively researched in surgery with respect to patient diagnosis and predicting outcomes. There are also several limitations with the software including artificial hallucination, bias, out‐of‐date information and patient confidentiality.Conclusion: The potential of ChatGPT and related generative AI models are vast, heralding the beginning of a new era where AI may eventually become integrated seamlessly into surgical practice. Concerns with this new technology must not be disregarded in the urge to hasten progression, and potential risks impacting patients' interests must be considered. Appropriate regulation and governance of this technology will be key to optimising the benefits and addressing the intricate challenges of healthcare delivery and equity.


  • Open Access

    The Effect of Clinical Face Shields on Aerosolized Particle Exposure

    by Ian Chao, Sarah Lee, Jason Brenker, Derrick Wong, Caitlin Low, Mathilde Desselle, Anne Bernard, Tuncay Alan, Zoe Keon-Cohen, Jasamine Coles-Black

    Background: Face shields protect healthcare workers (HCWs) from fluid and large droplet contamination. Their effect on smaller aerosolized particles is unknown. Materials & methods: An ultrasonic a... Plain language summary Face shields protect health workers from splash contamination. We do not know if they protect against smaller invisible aerosol drops that can carry diseases like coronavirus...

  • Inexpensive 3D Printed Trainer for Combined Retrograde Intrarenal Surgery and Percutaneous Nephrolithotomy

    by Jasamine Coles-Black, Harrison Tucker, Joseph Ischia, Maria Woodruff, David Webb, Damien Bolton

    Introduction: Percutaneous nephrolithotomy (PCNL) and retrograde intrarenal surgery (RIRS) are technically challenging endourologic procedures with a steep learning curve for trainees. 1 Teaching these skills has presented a demanding challenge for surgical educators, because of the lack of appropriate training simulators. 2 When both techniques are combined for complex stone cases, the difficulties in teaching the required psychomotor skills are compounded. To overcome these problems, we present the first combined RIRS PCNL training model. The trainer was developed using 3D printing technology, for Percutaneous Renal Surgery—A Practical Clinical Handbook 3 to update the models to teach combined RIRS PCNL. Open-source software 4 (3D Slicer, version 4.12; Harvard) was used to segment the renal parenchyma and collecting system using anonymized computed tomography data. This process took 1 hour. Further modifications were performed using open-source computer-aided design software (Tinkercad; AutoDesk, CA) for 30 minutes. The collecting system was contained within a negative space continuous with a 1.5 cm cylinder superiorly to allow for percutaneous renal access, and a hollow ureter inferiorly to allow for retrograde ureteroscopic access. The renal model was produced using a Photon Mono SE (Anycubic, Shenzhen, China) 3D printer and printed in 8 hours 12 minutes. A flesh-colored resin was chosen to replicate the endoscopic appearance of the collecting system, enhancing its realism. In addition, the model was printed using opaque material to blind the trainee to external cues when orientating the endoscopes. The RIRS PCNL training model was developed for under USD$3 per model and has been made available online as an appendix in this video publication. Results: Expert educators involved in the national training of RIRS PCNL were invited to trial the simulator to evaluate its suitability as a training tool, as demonstrated in the accompanying video. Surgical lubricant aerosol was applied to the collecting system to imitate the ureteral lumen when passing a flexible ureteroscope (Karl Storz Endoscopy, Tuttlingen, Germany). Postworkshop, the urologists concluded that the face validity of the 3D printed trainer was superior to commercially available alternatives and ideal for surgical skills training at Urological Society of Australia and New Zealand (USANZ) and other international training courses. Conclusions: Although the current urologic literature has predominantly focused on the uro-oncologic applications of 3D printing technologies, 5 we aimed to highlight the utility of 3D printed models for the training of complex and combined endourologic procedures, which has remained relatively unexplored. Using 3D printing, we have developed an inexpensive readily accessible combined RIRS PCNL training model that we have made freely available online. Future study will involve the development of additional models for the preoperative planning of complex PCNL procedures such as staghorn and caliceal diverticular calculi and further validation of the content and construct validity of the 3D printed simulators. No competing financial interests exist. Runtime of video: 6 mins 2 secs

  • Open Access

    3D printed patient-specific prostate cancer models to guide nerve-sparing robot-assisted radical prostatectomy: a systematic review

    by Jasamine Coles-Black, Sean Ong, Jiasian Teh, Paul Kearns, Joseph Ischia, Damien Bolton, Nathan Lawrentschuk

    Precise knowledge of each patient’s index cancer and surrounding anatomy is required for nerve-sparing robot-assisted radical prostatectomy (NS-RARP). Complementary to this, 3D printing has proven its utility in improving the visualisation of complex anatomy. This is the first systematic review to critically assess the potential of 3D printed patient-specific prostate cancer models in improving visualisation and the practice of NS-RARP. A literature search of PubMed and OVID Medline databases was performed using the terms “3D Printing”, “Robot Assisted Radical Prostatectomy” and related index terms as per the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Eight articles were included; six were identified via database searches, to which a further two articles were located via a snowballing approach. Eight papers were identified for review. There were five prospective single centre studies, one case series, one technical report and one letter to the editor. Of these articles, five publications (62.5%) reported on the utility of 3D printed models for NS-RARP planning. Two publications (25%) utilised 3D printed prostate models for simulation and training, and two publications (25%) used the models for patient engagement. Despite the nascency of the field, 3D printed models are emerging in the uro-oncological literature as a useful tool in visualising complex anatomy. This has proven useful in NS-RARP for preoperative planning, simulation and patient engagement. However, best practice guidelines, the future regulatory landscape, and health economic considerations need to be addressed before this synergy of new technologies is ready for the mainstream.


  • On-Demand Manufacturing of Inexpensive 3D Printed Meatal Dilators During Supply Chain Disruptions

    by Jasamine Coles-Black, Ian Chao, Joseph Ischia, Nathan Lawrentschuk, Dennis Gyomber, Damien Bolton

  • Open Access

    3D Printed Patient-Specific Complex Hip Arthroplasty Models Streamline the Preoperative Surgical Workflow: A Pilot Study

    by Michael Jiang, Jasamine Coles-Black, Gordon Chen, Matthew Alexander, Jason Chuen, Andrew Hardidge

    Introduction: Surgical planning for complex total hip arthroplasty (THA) often presents a challenge. Definitive plans can be difficult to decide upon, requiring unnecessary equipment to be ordered and a long theatre list booked. We present a pilot study utilising patient-specific 3D printed models as a method of streamlining the pre-operative planning process.Methods: Complex patients presenting for THA were referred to the research team. Patient-specific 3D models were created from routine Computed Tomography (CT) imaging. Simulated surgery was performed to guide prosthesis selection, sizing and the surgical plan.Results: Seven patients were referred for this pilot study, presenting with complex conditions with atypical anatomy. Surgical plans provided by the 3D models were more detailed and accurate when compared to 2D CT and X ray imaging. Streamlined equipment selection was of great benefit, with augments avoided post simulation in three cases. The ability to tackle complex surgical problems outside of the operating theatre also flagged potential complications, while also providing teaching opportunities in a low risk environment.Conclusion: This study demonstrated that 3D printed models can improve the surgical plan and streamline operative logistics. Further studies investigating the optimal 3D printing material and workflow, along with cost-benefit analyses are required before this process is ready for routine use.


  • Utility of 3D printed abdominal aortic aneurysm phantoms: a systematic review

    by Jasamine Coles‐Black, Damien Bolton, Domenic Robinson, Jason Chuen

    Background 3D printed (3DP) abdominal aortic aneurysm (AAA) phantoms are emerging in the literature as an adjunct for the visualization of complex anatomy, particularly for presurgical device selection and simulation. This is the first systematic review to provide a comprehensive overview of 3DP for endovascular aneurysm repair (EVAR) planning and intervention, evaluating the readiness of current levels of technology for mainstream implementation. Methods A systematic literature search of PubMed and MEDLINE was performed as per PRISMA guidelines using the terms ‘3D Printing’, ‘AAA’ OR ‘EVAR’ and related index terms, and further relevant articles were appraised via a snowballing approach. Our last search was conducted on 14 November 2020. Results Twenty‐five articles were identified for critical analysis, with 14 cases or technical reports. Nineteen publications utilized 3DP AAA phantoms to aid presurgical decision making, device selection and design. Four publications explored the utility of 3DP phantoms as EVAR trainers, and one publication examined the technology as a tool for patient education. Flexible, transparent phantoms were deemed most useful; however, the cost and availability of higher end machines limited accessibility. Conclusion 3DP phantoms have been used in EVAR to facilitate visualization of complex patient anatomy, appropriate device selection, in predicting navigational difficulties and the shape and position of endograft after deployment. These phantoms show promise in reducing known complications such as endoleak, stent graft occlusion and migration; however, larger scale prospective studies are required to validate its impacts on patient outcomes and cost savings to the healthcare system.