AIAlla Ivanyshyn

Alla Ivanyshyn

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alla Ivanyshyn has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Compact Microcontroller-Based LED-Driven Photoelectric System for Accurate Photoresponse Mapping Compatible with Internet of Things

    by Bohdan Sus, Alexey Kozynets, Sergii Litvinenko, Alla Ivanyshyn, Tetiana Bubela, Mikołaj Skowron, Krzysztof Przystupa

    A compact LED (light emission diode)-based illumination unit controlled by a microcontroller was developed for recombination-type silicon sensor structures. The system employs an 8 × 8 LED matrix that provides programmable spatial excitation patterns across a 2.2 × 2.2 mm sensor surface. Its operation is based on changes in the silicon surface recombination properties upon analyte interaction, producing photocurrent variations of 10–50 nA depending on the dipole moment. Compared with conventional laser-based systems, the proposed LED illumination significantly reduces cost, complexity, and power consumption while maintaining sufficient optical intensity for reliable photoresponse detection. The embedded controller enables precise timing, synchronization with the photocurrent acquisition unit, and flexible adaptation for various biological fluid analyses. This implementation demonstrates a scalable and cost-efficient alternative to stationary LBIC setups and supports integration into portable or IoT-compatible diagnostic systems. For comparative screening, the LED array was used instead of the focused laser beam typically employed in LBIC (laser beam-induced current) measurements. This paper substantially reduced the peak optical intensity at the sample surface, minimizing local thermal heating critical for enzyme-based or plasma samples sensitive to temperature fluctuations. Photocurrent mapping reveals charge-state modification of recombination centers at the SiOx/Si interface under optical excitation. Further optimization is expected for compact or simplified configurations, particularly those aimed at portable applications and automated physiological monitoring systems.

  • Open Access

    Risk Assessment of the Functioning of Cyber-Physical Monitoring Systems

    by Tetiana Bubela, Joanna Michalowska, Nataliya Hots, Vasyl Yatsuk, Oleh Seheda, Alla Ivanyshyn, Bohdan Sus, Aleksey Kozynets

    An assessment of the risks of the functioning of cyber-physical systems was carried out. It is proposed to divide them into information risks and metrological risks, since the cyber-physical system is an information and measurement system. Classification features are proposed and risks are structured as an information and measurement system. The Risk Analysis & Management Method (CRAMM) was used to assess the information risks of the cyber-physical systems. According to the results of its use on the example of the cyber-physical soil monitoring system, the levels of vulnerabilities and their weighting effects were identified and calculated, on the basis of which the levels of information risk were calculated. It was established that the highest risk in the studied system is associated with information distortion and failures in the communication network. Corrective actions to reduce them were proposed. The assessment of metrological risks was carried out using the principles of ISO 31000:2018, according to which the probability of occurrence of the event and the severity of the consequences of its occurrence for the soil monitoring system were assessed. For the final formation of the assessment, a matrix of metrological risks was proposed, according to which all metrological risks of the studied system had low and medium levels. It has been established that the methods proposed by the authors can be applied to cyber-physical systems of other purposes.


  • Open Access

    Method for Correcting Error Due to Self-Heating of Resistance Temperature Detectors Suitable for Metrology in Industry 4.0

    by Jiyun Li, Hongxing Pei, Orest Kochan, Chunzhi Wang, Roman Kochan, Alla Ivanyshyn

    This study contributes to improving the accuracy of temperature measurements with a platinum resistance temperature detector (RTD) by proposing techniques to mitigate the error due to self-heating by the operating current. An assessment of the measurement errors of the platinum RTD was carried out to study ways to improve their accuracy. High accuracy can be achieved by individual calibration using a voltage divider circuit to measure resistance, the substitution method, and the transitional measure. It was shown that each of these approaches offers potential improvements in the accuracy of temperature measurements using RTDs. However, one of the genuine limitations is the error due to heating the RTD by the operating current. To address this, both linear and nonlinear methods for correcting the error due to heating by the operating current were studied. This paper examines how these methods can be applied to mitigate the influence of self-heating on measurement accuracy. Moreover, the residual errors associated with these methods of correction were estimated. The analysis showed that while these methods can reduce the errors significantly, there remain limitations below which it is not possible to mitigate the error.


  • Open Access

    ROOT SURFACE TEMPERATURE MEASUREMENT DURING ROOT CANAL OBTURATION

    by Les Hotra, Oksana Boyko, Igor Helzhynskyy, Hryhorii Barylo, Pylyp Skoropad, Alla Ivanyshyn, Olena Basalkevych

    Prolonged exposure to elevated temperatures exceeding 47°C, which can occur during root canal obturation, can cause damage of both dental and bone tissues. In order to study the temperature distribution on the surface of the tooth root a temperature measuring device with cold-junction compensation is proposed. For in vitro measurement of the temperature distribution on the surface of the tooth, 8 thermocouples placed in direct contact with the cementum of the tooth were used. In order to eliminate the cold-junction temperature variations, the temperature equilibration device and RTD were used. The suggested linear approximation for the thermocouples' conversion function provides a nonlinearity relative error of less than 0.05% for K-type thermocouples and 0.07% for J-type thermocouples over the temperature range from 20 to 60°C.

  • Intelligent Expert Systems Application for Structuring Educational Materials to Enhance the Quality of Learning Outcomes

    by Alla Ivanyshyn, Tetiana Zahorodniuk, Valentyna Maliarenko, Bohdan Sus, Sergiy Zagorodnyuk, Oleksandr Bauzha, Oksana Boyko

    Application of intelligent expert systems for structuring and automation of laboratory activities in the educational process has been analysed. It is shown that combination of teaching materials with cross-references and transitions by the means of expert systems allows educators to make optimal decisions on time, set priorities and prepare more effective laboratory classes. The implementation of expert systems for classification sections of academic disciplines in both engineering and technical sciences and humanities has been discussed. An algorithm for making decisions by an expert system, where the main emphasis is given to laboratory tasks and work with laboratory equipment, is proposed. It is shown how to develop a new expert system which can help university educators prepare remote laboratory work, and also to use of virtual simulators or effective practical training. The proposed expert systems can be used for classifying thematic sections of a wide range of disciplines, including natural sciences, engineering, and humanities. They can be used for preparing new courses and training new educators in different areas. Thus expert systems are described as high-scale software units without restrictions on the depth of the question tree and the number of logical branches of the classifier.


  • EUROPEAN AND INTERNATIONAL principles FOR QUALITY MANAGEMENT IN EDUCATION USING INTELLIGENT TECHNOLOGIES

    by Alla Ivanyshyn

    The article compares the international and European requirements for institutions of higher education. General international principles of quality management were also considered and adapted to institutions of higher education. The main requirements for the quality management system (QMS) of a higher education institution (HEI) following international and European standards,) as well as the advantages and main requirements for the implementation of the quality management of educational services, as a tool for managing the processes of providing educational services and improving their quality.