Cheng-Yu Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Cheng-Yu Tang has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Yaow-Ming Chen
Department of Electrical Engineering, National Taiwan University, Taipei, Taiwan
9 shared publications Sheng-Yuan Ou
Department of Electrical Engineering, National Taipei University of Technology, Taiwan
5 shared publicationsYen-Fu Chen
3 shared publicationsYung-Ruei Chang
Atomic Energy Council, Institute of Nuclear Energy Research, Taoyuan, Taiwan
3 shared publicationsDa-De Shih
National Taipei University of Technology,Department of Electrical Engineering,Taipei,Taiwan
2 shared publicationsJia-He Jheng
Delta Electronics, Taoyuan, Taiwan
2 shared publications
Latest Publications
- 20 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (6) , 7261-7274
Dynamic Phase Current Compensation and DC-Link Voltage Ripple Mitigation Strategies for Three-Phase Neutral-Point-Clamped Grid-Tied Inverters Under Unbalanced Grid Voltages
This paper proposes dynamic phase current compensation and DC-link voltage mitigation strategies for three-phase four-wire neutral-point-clamped (NPC) grid-tied inverters under unbalanced grid voltages. When the grid fault occurs, the fault-phase voltage will diverge from its normal value. To achieve the reactive power compensation capability, the inverter should output reactive current on the fault phase. However, the unbalanced three-phase active/reactive power generates non-ideal harmonics and oscillations on the DC-link voltage, which might damage the DC-link capacitors. It is possible to increase the capacitance to suppress the ripple. However, the circuit size and cost will be increased. Therefore, this paper develops a dynamic phase current compensation (DPCC) strategy. This strategy will dynamically adjust the magnitude and phase angle of normal phase currents. Consequently, the harmonics and oscillations on the DC-link voltage can effectively be suppressed. The developed DPCC does not require additional circuits and components, and this strategy can be realized via the digital signal processor (DSP). Detailed theoretical analysis and mathematical derivations of the proposed strategy will be presented in this paper. Finally, a 5kVA prototype circuit with both computer simulations and hardware experiments demonstrates the performance and feasibility of the proposed DPCC. From the results, it can be confirmed that the maximum suppression rate of DC-link voltage ripple will be 83.17% with the proposed DPCC.
- 20 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (6) , 7261-7274
Dynamic Phase Current Compensation and DC-Link Voltage Ripple Mitigation Strategies for Three-Phase Neutral-Point-Clamped Grid-Tied Inverters Under Unbalanced Grid Voltages
This paper proposes dynamic phase current compensation and DC-link voltage mitigation strategies for three-phase four-wire neutral-point-clamped (NPC) grid-tied inverters under unbalanced grid voltages. When the grid fault occurs, the fault-phase voltage will diverge from its normal value. To achieve the reactive power compensation capability, the inverter should output reactive current on the fault phase. However, the unbalanced three-phase active/reactive power generates non-ideal harmonics and oscillations on the DC-link voltage, which might damage the DC-link capacitors. It is possible to increase the capacitance to suppress the ripple. However, the circuit size and cost will be increased. Therefore, this paper develops a dynamic phase current compensation (DPCC) strategy. This strategy will dynamically adjust the magnitude and phase angle of normal phase currents. Consequently, the harmonics and oscillations on the DC-link voltage can effectively be suppressed. The developed DPCC does not require additional circuits and components, and this strategy can be realized via the digital signal processor (DSP). Detailed theoretical analysis and mathematical derivations of the proposed strategy will be presented in this paper. Finally, a 5kVA prototype circuit with both computer simulations and hardware experiments demonstrates the performance and feasibility of the proposed DPCC. From the results, it can be confirmed that the maximum suppression rate of DC-link voltage ripple will be 83.17% with the proposed DPCC.
- 9 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1330-1335
A Single-Phase Totem-Pole Converter with Four Quadrants Active and Reactive Power Control by Using the Direct-Quadrature Control
A single-phase totem pole converter with four quadrants of active and reactive power flow control is designed and implemented in this paper. This converter consists of a DC side and an AC side. When energy is supplied from the DC side to the AC side, it operates in a DC-AC grid-tied mode. When energy is supplied from the AC side to the DC side, it functions as a Power Factor Corrector (PFC). In addition, the converter can provide reactive power to the grid to realize the low-voltage ride-through (LVRT) function during grid fault scenarios. This converter utilizes Clarke and Park transformations to convert the AC components into DC components. Besides, the proportional-integral (PI) controller is adopted to regulate the active and reactive power as well as to achieve the four quadrants power flow control. The circuit specifications are with 400V dc on the DC side and 110Vac/220Vac on the AC side. The rated apparent power is 500VA. Finally, the developed circuit and control strategies are first verified via the PLECS simulation software. The digital signal processor (DSP) TMS320F28379D made by Texas Instruments is utilized to achieve the hardware circuit validation.
- 9 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1330-1335
A Single-Phase Totem-Pole Converter with Four Quadrants Active and Reactive Power Control by Using the Direct-Quadrature Control
A single-phase totem pole converter with four quadrants of active and reactive power flow control is designed and implemented in this paper. This converter consists of a DC side and an AC side. When energy is supplied from the DC side to the AC side, it operates in a DC-AC grid-tied mode. When energy is supplied from the AC side to the DC side, it functions as a Power Factor Corrector (PFC). In addition, the converter can provide reactive power to the grid to realize the low-voltage ride-through (LVRT) function during grid fault scenarios. This converter utilizes Clarke and Park transformations to convert the AC components into DC components. Besides, the proportional-integral (PI) controller is adopted to regulate the active and reactive power as well as to achieve the four quadrants power flow control. The circuit specifications are with 400V dc on the DC side and 110Vac/220Vac on the AC side. The rated apparent power is 500VA. Finally, the developed circuit and control strategies are first verified via the PLECS simulation software. The digital signal processor (DSP) TMS320F28379D made by Texas Instruments is utilized to achieve the hardware circuit validation.
- 20 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A Multi-Port Converter with Multi-Directional Power Flow Control Strategies for PV Power and Energy Storage Systems
In this paper, a multi-port converter (MPC) integrated with multi-directional power flow control (MDPFC) strategies is proposed. Compare to individual converter structures, the proposed MPC can decrease the circuit cost and complexity in multi power source applications. In the meantime, the PV power is considered for the proposed MPC while the MPPT function is realized. In order to overcome the unpredictable PV characteristics and load conditions, the battery module is adopted. In order to regulate the energy between the PV array, the battery and the load, the MDPFC strategies are developed in this paper. Moreover, the MDPFC can realized by the digital signal processor (DSP) without adding extra circuit and components. Compare to existed circuit topologies, the developed MPC and MDPFC can achieve the maximum energy utilization with only one inductor and limited circuit components. Finally, a 500W prototype hardware circuit will be implemented to verify the performance and feasibility of the proposed MPC. From the experimental validations, the peak circuit efficiency and the full-load efficiency are 97.22% and 96.3%, respectively.
- 20 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A Multi-Port Converter with Multi-Directional Power Flow Control Strategies for PV Power and Energy Storage Systems
In this paper, a multi-port converter (MPC) integrated with multi-directional power flow control (MDPFC) strategies is proposed. Compare to individual converter structures, the proposed MPC can decrease the circuit cost and complexity in multi power source applications. In the meantime, the PV power is considered for the proposed MPC while the MPPT function is realized. In order to overcome the unpredictable PV characteristics and load conditions, the battery module is adopted. In order to regulate the energy between the PV array, the battery and the load, the MDPFC strategies are developed in this paper. Moreover, the MDPFC can realized by the digital signal processor (DSP) without adding extra circuit and components. Compare to existed circuit topologies, the developed MPC and MDPFC can achieve the maximum energy utilization with only one inductor and limited circuit components. Finally, a 500W prototype hardware circuit will be implemented to verify the performance and feasibility of the proposed MPC. From the experimental validations, the peak circuit efficiency and the full-load efficiency are 97.22% and 96.3%, respectively.
- 20 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 194-198
The DC-Link Voltage Double Line Frequency Ripple Reduction for AC-DC Converters
This paper proposes a control method of reducing the dc-link voltage double line frequency ripple in AC-DC converters. The proposed method utilizes variable duty cycle control, allowing for a reduction in the dc-link capacitance, thereby decreasing the size and cost of the converter. Additionally, the proposed control method eliminates the need for a current sensor, which is typically required in conventional harmonic input current injection techniques. This paper provides detailed mathematical analyses and design procedures for a boost PFC converter with the proposed control method. Furthermore, computer simulation and experimental results are included to validate the effectiveness and performance of the proposed control method.
- 20 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 194-198
The DC-Link Voltage Double Line Frequency Ripple Reduction for AC-DC Converters
This paper proposes a control method of reducing the dc-link voltage double line frequency ripple in AC-DC converters. The proposed method utilizes variable duty cycle control, allowing for a reduction in the dc-link capacitance, thereby decreasing the size and cost of the converter. Additionally, the proposed control method eliminates the need for a current sensor, which is typically required in conventional harmonic input current injection techniques. This paper provides detailed mathematical analyses and design procedures for a boost PFC converter with the proposed control method. Furthermore, computer simulation and experimental results are included to validate the effectiveness and performance of the proposed control method.
- 20 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Optimal Planar Transformer Design Considerations for GaN-Based High Frequency Isolated Converters
This paper proposes the optimal planar transformer design considerations for GaN-based high frequency isolated converters. Main considerations to design the optimal planar transformer can be highlighted as: (1) Materials and separation distance of insulating layers. (2) The interwinding and intra-winding capacitances. (3) The sequences of insulating layer. (4) The winding coverage. In this paper, four planar transformers with different insulating layer materials, sequences and winding coverages are developed and compared. The electromagnetic simulation software will be included for analysis. Besides, an active clamp flyback (ACF) converter with the zero-voltage switching (ZVS) feature will be designed and implemented for validations. Comprehensive analysis and comparisons of the four developed planar transformers will be presented. With the proposed analysis and optimal design, the voltage spike of switches can be eliminated with 2.49%. The circuit efficiency can be improved with 8.82%, whereas the maximum circuit efficiency with the proposed optimal planar transformer will be 92.64%.
- 20 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Optimal Planar Transformer Design Considerations for GaN-Based High Frequency Isolated Converters
This paper proposes the optimal planar transformer design considerations for GaN-based high frequency isolated converters. Main considerations to design the optimal planar transformer can be highlighted as: (1) Materials and separation distance of insulating layers. (2) The interwinding and intra-winding capacitances. (3) The sequences of insulating layer. (4) The winding coverage. In this paper, four planar transformers with different insulating layer materials, sequences and winding coverages are developed and compared. The electromagnetic simulation software will be included for analysis. Besides, an active clamp flyback (ACF) converter with the zero-voltage switching (ZVS) feature will be designed and implemented for validations. Comprehensive analysis and comparisons of the four developed planar transformers will be presented. With the proposed analysis and optimal design, the voltage spike of switches can be eliminated with 2.49%. The circuit efficiency can be improved with 8.82%, whereas the maximum circuit efficiency with the proposed optimal planar transformer will be 92.64%.
- Open Access
- 30 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 121162-121172
A Synchronization Shift Phase-Locked Loop Strategy for Three-Phase Grid-Tied Inverters Under Unbalanced Grid Voltage Scenarios
The phase-locked loop (PLL) is one of the most commonly used approaches for the inverter to achieve grid-connected operation. However, when unbalanced grid voltages occur, the double-line frequency oscillation exists in the system. With the conventional PLL method, the synchronous reference frame (SRF) voltage will be oscillated because of the double-line frequency oscillation. As a result, the electrical angle of the grid cannot be estimated accurately. Moreover, inverter output currents will be distorted and the current total harmonic distortion (iTHD) will be increased. To solve this issue, an enhanced synchronization shift phase-locked loop (SSPLL) strategy is proposed in this paper. With the proposed SSPLL, the inherent double-line frequency oscillation in the control loop can be eliminated. Therefore, the electrical angle of the grid can precisely be calculated, whereas the current THD can be suppressed. The developed SSPLL can be realized by the digital signal processor (DSP) without adding extra circuits and components. Comprehensive theoretical analysis and mathematical derivations of the SSPLL are also revealed. Eventually, both simulation and experimental results obtained from a 5kVA prototype circuit will be presented to verify the performance and feasibility of the proposed SSPLL. Compare to conventional PLL methods, a maximum 65.22% improvement of current THD and a maximum 51.2% improvement of the controller execution time can be achieved with the proposed strategy.
- 30 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 121162-121172
Open AccessA Synchronization Shift Phase-Locked Loop Strategy for Three-Phase Grid-Tied Inverters Under Unbalanced Grid Voltage Scenarios
The phase-locked loop (PLL) is one of the most commonly used approaches for the inverter to achieve grid-connected operation. However, when unbalanced grid voltages occur, the double-line frequency oscillation exists in the system. With the conventional PLL method, the synchronous reference frame (SRF) voltage will be oscillated because of the double-line frequency oscillation. As a result, the electrical angle of the grid cannot be estimated accurately. Moreover, inverter output currents will be distorted and the current total harmonic distortion (iTHD) will be increased. To solve this issue, an enhanced synchronization shift phase-locked loop (SSPLL) strategy is proposed in this paper. With the proposed SSPLL, the inherent double-line frequency oscillation in the control loop can be eliminated. Therefore, the electrical angle of the grid can precisely be calculated, whereas the current THD can be suppressed. The developed SSPLL can be realized by the digital signal processor (DSP) without adding extra circuits and components. Comprehensive theoretical analysis and mathematical derivations of the SSPLL are also revealed. Eventually, both simulation and experimental results obtained from a 5kVA prototype circuit will be presented to verify the performance and feasibility of the proposed SSPLL. Compare to conventional PLL methods, a maximum 65.22% improvement of current THD and a maximum 51.2% improvement of the controller execution time can be achieved with the proposed strategy.
- 15 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (11) , 13587-13593
A Dynamic Smooth Transition Control Integrated With Hybrid Modulation for Wide Output Voltage Range Bidirectional CLLC Resonant Converters
The objective of this letter is to propose a dynamic smooth transition control (DSTC) integrated with hybrid modulation for wide output voltage range bidirectional CLLC resonant converters. Traditionally, the pulse frequency modulation (PFM) technique is adopted for CLLC resonant converters. However, under the low output voltage and light load condition, the PFM control might be failed because of the parasitic effect under high-frequency operation. To solve this issue, the phase-shift modulation (PSM) can be included to achieve wide output voltage range and full load operation. Therefore, the hybrid modulation integrated with PFM and PSM is utilized in this letter. Moreover, in order to suppress the voltage fluctuation and to reduce the response time during the mode switching transient, a DSTC is proposed in this letter. The proposed control can be implemented by the digital signal processor without adding extra circuit and components. Finally, a 2-kW prototype CLLC resonant converter is built to verify the performance and feasibility of the proposed circuit and control strategy. Experimental results show that the peak circuit conversion efficiency is 96.7%, whereas the improvement of the voltage fluctuation and the transient response time during the mode switching are equal to 50% and 42%, respectively.
- 15 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (11) , 13587-13593
A Dynamic Smooth Transition Control Integrated With Hybrid Modulation for Wide Output Voltage Range Bidirectional CLLC Resonant Converters
The objective of this letter is to propose a dynamic smooth transition control (DSTC) integrated with hybrid modulation for wide output voltage range bidirectional CLLC resonant converters. Traditionally, the pulse frequency modulation (PFM) technique is adopted for CLLC resonant converters. However, under the low output voltage and light load condition, the PFM control might be failed because of the parasitic effect under high-frequency operation. To solve this issue, the phase-shift modulation (PSM) can be included to achieve wide output voltage range and full load operation. Therefore, the hybrid modulation integrated with PFM and PSM is utilized in this letter. Moreover, in order to suppress the voltage fluctuation and to reduce the response time during the mode switching transient, a DSTC is proposed in this letter. The proposed control can be implemented by the digital signal processor without adding extra circuit and components. Finally, a 2-kW prototype CLLC resonant converter is built to verify the performance and feasibility of the proposed circuit and control strategy. Experimental results show that the peak circuit conversion efficiency is 96.7%, whereas the improvement of the voltage fluctuation and the transient response time during the mode switching are equal to 50% and 42%, respectively.
- 16 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (1) , 27-33
An Active Power Ripple Mitigation Strategy for Three-Phase Grid-Tied Inverters Under Unbalanced Grid Voltages
This letter proposes an active power ripple mitigation strategy for the three-phase three-wire grid-tied inverter. Under the unbalanced grid voltage scenarios, the double-line frequency oscillation will have occurred on the inverter output power and the dc-link voltage. Traditionally, the three-phase four-wire or the three-phase four-leg topology could be adopted to deal with this issue. Besides, the negative and the zero-sequence current component can be controlled to cancel out the power ripple. However, the circuit cost and control complexity might be increased. Therefore, a virtual phase-current regulation (VPCR) method is developed by adding compensation to the current feedback of the fault voltage. The compensation value is consistent with the voltage drop ratio, which can effectively offset the actual power ripple. The main feature of the VPCR is its simplicity, whereas it can be realized via the digital signal processor without adding extra circuit components. Theoretical analysis and mathematical derivations of the VPCR will also be revealed. Finally, a 3 kW prototype circuit with both simulation and experimental results verify the performance and feasibility of the proposed strategy. The experimental results show that the output power ripple can be eliminated with 64.3% via the proposed VPCR.
- 16 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (1) , 27-33
An Active Power Ripple Mitigation Strategy for Three-Phase Grid-Tied Inverters Under Unbalanced Grid Voltages
This letter proposes an active power ripple mitigation strategy for the three-phase three-wire grid-tied inverter. Under the unbalanced grid voltage scenarios, the double-line frequency oscillation will have occurred on the inverter output power and the dc-link voltage. Traditionally, the three-phase four-wire or the three-phase four-leg topology could be adopted to deal with this issue. Besides, the negative and the zero-sequence current component can be controlled to cancel out the power ripple. However, the circuit cost and control complexity might be increased. Therefore, a virtual phase-current regulation (VPCR) method is developed by adding compensation to the current feedback of the fault voltage. The compensation value is consistent with the voltage drop ratio, which can effectively offset the actual power ripple. The main feature of the VPCR is its simplicity, whereas it can be realized via the digital signal processor without adding extra circuit components. Theoretical analysis and mathematical derivations of the VPCR will also be revealed. Finally, a 3 kW prototype circuit with both simulation and experimental results verify the performance and feasibility of the proposed strategy. The experimental results show that the output power ripple can be eliminated with 64.3% via the proposed VPCR.
- 29 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (9) , 10281-10289
An Active Clamp Flyback Converter With High Precision Primary-Side Regulation Strategy
The active clamp flyback (ACF) converter has been widely adopted because of the feature of isolation, soft-switching, and high conversion efficiency. On the other hand, due to the characteristic of the circuit cost reduction and the fast control response, the primary-side regulation (PSR) has become a popular control method for isolated power converters. However, high precision PSR strategies for ACF converters are not exposed. Therefore, the aim of this article is to propose a high precision PSR strategy for the ACF converter. Relations between the primary-side current and the secondary-side current are analyzed and derived. Both of the continuous conduction mode operation and the discontinuous conduction mode operation will be considered. The output voltage control mode or the output current control mode can be selected via the proposed strategy. In addition, a secondary-side losses compensation (SSLC) strategy is developed to deal with the non-ideal circuit characteristics as well as to enhance the control accuracy. Operational principles and thorough mathematical derivations will also be revealed. Finally, both simulation and experimental results obtained from a 100 W prototype circuit demonstrate the performance and feasibility of the proposed PSR and SSLC strategy. Validations show that the control accuracy of the output voltage and the output current are 98.54% and 98.42%, respectively.
- 29 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (9) , 10281-10289
An Active Clamp Flyback Converter With High Precision Primary-Side Regulation Strategy
The active clamp flyback (ACF) converter has been widely adopted because of the feature of isolation, soft-switching, and high conversion efficiency. On the other hand, due to the characteristic of the circuit cost reduction and the fast control response, the primary-side regulation (PSR) has become a popular control method for isolated power converters. However, high precision PSR strategies for ACF converters are not exposed. Therefore, the aim of this article is to propose a high precision PSR strategy for the ACF converter. Relations between the primary-side current and the secondary-side current are analyzed and derived. Both of the continuous conduction mode operation and the discontinuous conduction mode operation will be considered. The output voltage control mode or the output current control mode can be selected via the proposed strategy. In addition, a secondary-side losses compensation (SSLC) strategy is developed to deal with the non-ideal circuit characteristics as well as to enhance the control accuracy. Operational principles and thorough mathematical derivations will also be revealed. Finally, both simulation and experimental results obtained from a 100 W prototype circuit demonstrate the performance and feasibility of the proposed PSR and SSLC strategy. Validations show that the control accuracy of the output voltage and the output current are 98.54% and 98.42%, respectively.
- 7 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (1) , 944-954
An Optimal Frequency-Modulated Hybrid MPPT Algorithm for the LLC Resonant Converter in PV Power Applications
The maximum power point tracking (MPPT) is an essential function of the PV power system to achieve the maximum PV power utilization. Traditionally, the MPPT can be realized by a duty cycle modulated dc–dc converter. However, if the LLC resonant converter is considered for the PV power system, the frequency-modulated MPPT algorithm should be adopted. Several strategies such as the frequency-based perturbation and observation (P&O) method and the center point iteration (CPI) method were proposed for the LLC resonant converter. However, with the conventional P&O method, there will be a tradeoff between the tracking speed and the oscillation phenomenon. Besides, the CPI method is unable to maintain the maximum power output under varying environmental conditions. In view of this, an optimal frequency-modulated hybrid MPPT algorithm is proposed in this article. First, the proposed frequency-modulated impedance-matching (FMIM) method is developed to track an optimal operation point under present environmental conditions. Then, the P&O concept will be utilized to ensure maximum power harvesting from the PV array. On the other hand, the operation point calculated via the FMIM is very close to the real MPP. Therefore, the perturbation amount of the P&O method can be minimized to avoid the oscillation around the maximum power point. Operational principles and thorough mathematical derivations are also developed. Finally, both simulation results and hardware verifications obtained from a 500-W prototype circuit demonstrate the performance and feasibility of the proposed MPPT.
- 7 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (1) , 944-954
An Optimal Frequency-Modulated Hybrid MPPT Algorithm for the LLC Resonant Converter in PV Power Applications
The maximum power point tracking (MPPT) is an essential function of the PV power system to achieve the maximum PV power utilization. Traditionally, the MPPT can be realized by a duty cycle modulated dc–dc converter. However, if the LLC resonant converter is considered for the PV power system, the frequency-modulated MPPT algorithm should be adopted. Several strategies such as the frequency-based perturbation and observation (P&O) method and the center point iteration (CPI) method were proposed for the LLC resonant converter. However, with the conventional P&O method, there will be a tradeoff between the tracking speed and the oscillation phenomenon. Besides, the CPI method is unable to maintain the maximum power output under varying environmental conditions. In view of this, an optimal frequency-modulated hybrid MPPT algorithm is proposed in this article. First, the proposed frequency-modulated impedance-matching (FMIM) method is developed to track an optimal operation point under present environmental conditions. Then, the P&O concept will be utilized to ensure maximum power harvesting from the PV array. On the other hand, the operation point calculated via the FMIM is very close to the real MPP. Therefore, the perturbation amount of the P&O method can be minimized to avoid the oscillation around the maximum power point. Operational principles and thorough mathematical derivations are also developed. Finally, both simulation results and hardware verifications obtained from a 500-W prototype circuit demonstrate the performance and feasibility of the proposed MPPT.