Yang Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yang Xu has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Gangbing Song
University of Houston
3 shared publications Mingzhang Luo
Yangtze University, Jingzhou, Hubei, CHINA
2 shared publicationsChuang Hei
1 shared publicationGuofeng Du
Yangtze University, Jingzhou, China
1 shared publicationJia Chun Li
Guizhou University
1 shared publication- Jian Fu
College of Pharmacy, Guizhou University of Traditional Chinese Medicine, Guizhou Key Laboratory for Germplasm Innovation and Resource-Efficient Utilization of Dao-di Herbs, National Engineering Technology Research Center for Miao Medicine, Guiyang, 550025, China
1 shared publication
Latest Publications
- 6 June 2019
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 28 (7) , 075019
PZT transducer array enabled pipeline defect locating based on time-reversal method and matching pursuit de-noising
In the process of pipeline structural health monitoring, it is necessary to detect pipe defects as well as to locate the defect’s axial and circumferential positions. Axial locating of a pipeline defect can be achieved by identifying the defect reflection packets in the direct detected axial displacement time history signals. In practice, various kinds of noise are involved in the actual detection signal. Using the matching pursuit (MP) algorithm based on a custom over-complete waveform dictionary, the noisy detection signal can be effectively de-noised, and the defect’s axial position can be located. The time-reversal method used in a waveguide leads to temporal and spatial focusing, and this feature is used to locate the defect’s circumferential position in the pipeline. In this paper, a new pipeline defect locating approach based on the time-reversal method and MP de-noising is proposed. The integration of the finite element method (FEM) numerical simulation with experiment is utilized to locate the pipeline defect. The defect axial position L x is located by the direct detected signal obtained from the actual pipeline defect detection experiment, after MP de-noising. A defect-free FEM reference model is established, and it has the same geometric and material parameters as the actual pipeline. Re-generating the time reversed defect reflection and the converted mode signals in the reference model, the energy will focus on the L x position. After obtaining the maximum values of the axial displacement time history signals received from the reference model at the L x position, the polar coordinate map based on these maxima can be plotted. The defect circumferential position is located based on the maximum values on the map. The FEM numerical simulation and experimental results are performed in this research. The defect locating results agree well with the actual pipeline defects, in both the axial and the circumferential directions.
- 6 June 2019
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 28 (7) , 075019
PZT transducer array enabled pipeline defect locating based on time-reversal method and matching pursuit de-noising
In the process of pipeline structural health monitoring, it is necessary to detect pipe defects as well as to locate the defect’s axial and circumferential positions. Axial locating of a pipeline defect can be achieved by identifying the defect reflection packets in the direct detected axial displacement time history signals. In practice, various kinds of noise are involved in the actual detection signal. Using the matching pursuit (MP) algorithm based on a custom over-complete waveform dictionary, the noisy detection signal can be effectively de-noised, and the defect’s axial position can be located. The time-reversal method used in a waveguide leads to temporal and spatial focusing, and this feature is used to locate the defect’s circumferential position in the pipeline. In this paper, a new pipeline defect locating approach based on the time-reversal method and MP de-noising is proposed. The integration of the finite element method (FEM) numerical simulation with experiment is utilized to locate the pipeline defect. The defect axial position L x is located by the direct detected signal obtained from the actual pipeline defect detection experiment, after MP de-noising. A defect-free FEM reference model is established, and it has the same geometric and material parameters as the actual pipeline. Re-generating the time reversed defect reflection and the converted mode signals in the reference model, the energy will focus on the L x position. After obtaining the maximum values of the axial displacement time history signals received from the reference model at the L x position, the polar coordinate map based on these maxima can be plotted. The defect circumferential position is located based on the maximum values on the map. The FEM numerical simulation and experimental results are performed in this research. The defect locating results agree well with the actual pipeline defects, in both the axial and the circumferential directions.
- 23 February 2018
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 27 (3) , 035023
Quantitative evaluation of compactness of concrete-filled fiber-reinforced polymer tubes using piezoceramic transducers and time difference of arrival
Owing to its light weight and corrosion resistance, the concrete-filled fiber-reinforced polymer tube (CFFT) structure has a broad application prospect; the concrete compactness is key to the strength of CFFTs. To meet the urgent requirement of compactness monitoring of CFFTs, a quantitative method, which uses an array of four equally spaced piezoceramic patches and an ultrasonic time difference of arrival (TDOA) algorithm, is developed. Since the velocity of the ultrasonic wave propagation in fiber-reinforced polymer (FRP) material is about half of that in concrete material, the compactness condition of CFFT impacts the piezoceramic-induced wave propagation in the CFFT, and differentiates the TDOA for different receivers. An important condition is the half compactness, which can be judged by the Half Compactness Indicator (HCI) based on the TDOAs. To characterize the difference of stress wave propagation durations from the emitter to different receivers, which can be utilized to calculate the concrete infill compactness, the TDOA ratio (TDOAR) is introduced. An innovative algorithm is developed in this paper to estimate the compactness of the CFFT using HCI and TDOAR values. Analytical, numerical, and experimental studies based on a CFFT with seven different states of compactness (empty, 1/10, 1/3, 1/2, 2/3, 9/10, and full) are carried out in this research. Analyses demonstrate that there is a good agreement among the analytical, numerical, and experimental results of the proposed method, which employs a piezoceramic transducer array and the TDOAR for quantitative estimating the compactness of concrete infill in a CFFT.
- 23 February 2018
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 27 (3) , 035023
Quantitative evaluation of compactness of concrete-filled fiber-reinforced polymer tubes using piezoceramic transducers and time difference of arrival
Owing to its light weight and corrosion resistance, the concrete-filled fiber-reinforced polymer tube (CFFT) structure has a broad application prospect; the concrete compactness is key to the strength of CFFTs. To meet the urgent requirement of compactness monitoring of CFFTs, a quantitative method, which uses an array of four equally spaced piezoceramic patches and an ultrasonic time difference of arrival (TDOA) algorithm, is developed. Since the velocity of the ultrasonic wave propagation in fiber-reinforced polymer (FRP) material is about half of that in concrete material, the compactness condition of CFFT impacts the piezoceramic-induced wave propagation in the CFFT, and differentiates the TDOA for different receivers. An important condition is the half compactness, which can be judged by the Half Compactness Indicator (HCI) based on the TDOAs. To characterize the difference of stress wave propagation durations from the emitter to different receivers, which can be utilized to calculate the concrete infill compactness, the TDOA ratio (TDOAR) is introduced. An innovative algorithm is developed in this paper to estimate the compactness of the CFFT using HCI and TDOAR values. Analytical, numerical, and experimental studies based on a CFFT with seven different states of compactness (empty, 1/10, 1/3, 1/2, 2/3, 9/10, and full) are carried out in this research. Analyses demonstrate that there is a good agreement among the analytical, numerical, and experimental results of the proposed method, which employs a piezoceramic transducer array and the TDOAR for quantitative estimating the compactness of concrete infill in a CFFT.
- Open Access
ECG Signal De-noising and Baseline Wander Correction Based on CEEMDAN and Wavelet Threshold
A novel electrocardiogram (ECG) signal de-noising and baseline wander correction method based on complete ensemble empirical mode decomposition with adaptive noise (CEEMDAN) and wavelet threshold is proposed. Although CEEMDAN is based on empirical mode decomposition (EMD), it represents a significant improvement of the original EMD by overcoming the mode-mixing problem. However, there has been no previous study on using CEEMDAN to de-noise ECG signals, to the authors’ best knowledge. In the proposed method, the original noisy ECG signal is decomposed into a series of intrinsic mode functions (IMFs) sorted from high to low frequency by CEEMDAN. Each IMF is then analyzed by the autocorrelation method to find out the first few high frequency IMFs containing random noise, and these IMFs should be de-noised by the wavelet threshold. The zero-crossing rate (ZCR) of all IMFs, including final residue, are computed, and the IMFs with ZCR less than a certain value are removed. Finally, the remaining IMFs are reconstructed to obtain the clean ECG signal. The proposed algorithm is validated through experiments using the MIT–BIH ECG databases, and the results show that the random noise in the ECG signal can be effectively suppressed, and at the same time the baseline wander can be corrected efficiently.
Open AccessECG Signal De-noising and Baseline Wander Correction Based on CEEMDAN and Wavelet Threshold
A novel electrocardiogram (ECG) signal de-noising and baseline wander correction method based on complete ensemble empirical mode decomposition with adaptive noise (CEEMDAN) and wavelet threshold is proposed. Although CEEMDAN is based on empirical mode decomposition (EMD), it represents a significant improvement of the original EMD by overcoming the mode-mixing problem. However, there has been no previous study on using CEEMDAN to de-noise ECG signals, to the authors’ best knowledge. In the proposed method, the original noisy ECG signal is decomposed into a series of intrinsic mode functions (IMFs) sorted from high to low frequency by CEEMDAN. Each IMF is then analyzed by the autocorrelation method to find out the first few high frequency IMFs containing random noise, and these IMFs should be de-noised by the wavelet threshold. The zero-crossing rate (ZCR) of all IMFs, including final residue, are computed, and the IMFs with ZCR less than a certain value are removed. Finally, the remaining IMFs are reconstructed to obtain the clean ECG signal. The proposed algorithm is validated through experiments using the MIT–BIH ECG databases, and the results show that the random noise in the ECG signal can be effectively suppressed, and at the same time the baseline wander can be corrected efficiently.
- 28 March 2011
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 52-54, 1692-1697
Heat Conduction Structural Topology Optimization Based on RAMP
Based on topology optimization techniques of structural mechanics, an effective method for solving the structural design problems of heat transfer is presented in this paper. The topology optimization model of heat conduction is then constructed and the corresponding Optimization Criteria based on density approach is inferred to solve the optimal heat conduction equation of temperature field. A Filtering technique is employed in density field to eliminate numerical instabilities in the process of topology optimization. Some numerical examples are presented to demonstrate the accuracy and the applicability of the present method, theory and algorithm. This research provides a new idea and an access to the structural topology optimization design of temperature field, and is of good engineering application value.
- 28 March 2011
- Published by Trans Tech Publications, Ltd. in Applied Mechanics and Materials
- Vol. 52-54, 1692-1697
Heat Conduction Structural Topology Optimization Based on RAMP
Based on topology optimization techniques of structural mechanics, an effective method for solving the structural design problems of heat transfer is presented in this paper. The topology optimization model of heat conduction is then constructed and the corresponding Optimization Criteria based on density approach is inferred to solve the optimal heat conduction equation of temperature field. A Filtering technique is employed in density field to eliminate numerical instabilities in the process of topology optimization. Some numerical examples are presented to demonstrate the accuracy and the applicability of the present method, theory and algorithm. This research provides a new idea and an access to the structural topology optimization design of temperature field, and is of good engineering application value.