CWC. R. Wu

C. R. Wu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


C. R. Wu has a total of 74 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Improved high-performance fully non-inductive discharge by optimizing the fast-ion confinement on EAST

    by J. Huang, J.P. Qian, A.M. Garofalo, X.Z. Gong, C.R. Wu, J.F. Chang, J. Zhang, H.F. Du, M.Q. Wu, B.L. Hao, et al.


  • Modeling study of the onset density for divertor detachment on EAST

    by X. J. Liu, L. Wang, G. Z. Deng, J. C. Xu, J. B. Liu, S. L. Gao, C. R. Wu, J. Huang, L. Zhang, G. Q. Li, et al.

    The onset density of detachment for L-mode discharges on Experimental Advanced Superconductiong Tokamamak has been studied using the SOLPS code. The effect of divertor closure on the onset density has been assessed by modifying the location of the strike point on a divertor plate. The modeling shows qualitative agreement with experiments in the density threshold. It is found that increasing divertor closure by moving the strike point close to the “V” corner can effectively trap neutrals in a localized region near the plasma strike point and then lower the density threshold of detachment. The influence of plasma current (Ip) on the onset density has also been investigated. The simulation shows that with Ip increased, divertor detachment was achieved at a relatively low normalized density due to the increase in Greenwald density (nG). In addition, the effect of the power across the scrape-off-layer (PSOL) and the radiation fraction on the detachment density threshold has also been studied. The detachment density increases significantly with PSOL as expected, and it can be approximately scaled by PSOL5/7, which is in accordance with the basic two-point model. It is also found that the detachment density can be reduced remarkably through increasing impurity radiative loss.


  • Performance of fast-ion loss diagnostic on EAST

    by C. R. Wu, J. Huang, J. F. Chang, J. Zhang, R. J. Zhou, Z. Xu, W. Gao, M. Isobe, K. Ogawa, S. Y. Lin, et al.

    The scintillator-based detector for fast-ion loss measurements has been installed on EAST. To obtain high temporal resolution for fast-ion loss diagnostics, fast photomultiplier tube systems have been developed which can supply the complementary measurements to the previous image system with good energy and pitch resolution by using a CCD camera. By applying the rotatable platform, the prompt losses of beam-ions can be measured in normal and reverse magnetic field. The thick-target bremsstrahlung occurring in the stainless steel shield with energetic electrons can produce X-rays, which will strike on the scintillator based detector. To understand this interference on fast-ion loss signals, the effects of energetic electrons on the scintillator-based detector are studied, including runaway electrons in the plasma ramping-up phase and fast electrons accelerated by the lower hybrid wave.


  • Fast ion D-alpha measurements using a bandpass-filtered system on EAST

    by J. Zhang, J. Huang, J. F. Chang, C. R. Wu, W. W. Heidbrink, M. Salewski, B. Madsen, Y. B. Zhu, M. G. von Hellermann, W. Gao, et al.

    Based on the charge exchange reaction between fast ions and a neutral beam, fast ion features can be inferred from the spectrum of Doppler-shifted Balmer-alpha light from energetic hydrogenic atoms. In order to study the interaction between instabilities and fast-ion transport, recently we extended the fast ion D-alpha (FIDA) measurements by using a combination of a bandpass filter and a photomultiplier tube (PMT) (f-FIDA). A bandpass filter selects the desired spectral band from 651 nm to 654 nm before detection by the PMT. Preliminary data from the EAST tokamak show that the active signals have been detected from reneutralized beam ions along the vertical and tangential viewing geometries. The details will be presented in this paper to primarily address the specifications and performance of f-FIDA hardware components and preliminary FIDA measurements.


  • Open Access

    Fast-ion Dα spectrum diagnostic in the EAST

    by Y. M. Hou, C. R. Wu, J. Huang, W. W. Heidbrink, M. G. von Hellermann, Z. Xu, Z. Jin, J. F. Chang, Y. B. Zhu, W. Gao, et al.

    In toroidal magnetic fusion devices, fast-ion D-alpha diagnostic (FIDA) is a powerful method to study the fast-ion feature. The fast-ion characteristics can be inferred from the Doppler shifted spectrum of Dα light according to charge exchange recombination process between fast ions and probe beam. Since conceptual design presented in the last HTPD conference, significant progress has been made to apply FIDA systems on the Experimental Advanced Superconducting Tokamak (EAST). Both co-current and counter-current neutral beam injectors are available, and each can deliver 2-4 MW beam power with 50-80 keV beam energy. Presently, two sets of high throughput spectrometer systems have been installed on EAST, allowing to capture passing and trapped fast-ion characteristics simultaneously, using Kaiser HoloSpec transmission grating spectrometer and Bunkoukeiki FLP-200 volume phase holographic spectrometer coupled with Princeton Instruments ProEM 1024B eXcelon and Andor DU-888 iXon3 1024 CCD camera, respectively. This paper will present the details of the hardware descriptions and experimental spectrum.


  • Scintillator-based fast ion loss measurements in the EAST

    by J. F. Chang, M. Isobe, K. Ogawa, J. Huang, C. R. Wu, Z. Xu, Z. Jin, S. Y. Lin, L. Q. Hu, East Team

    A new scintillator-based fast ion loss detector (FILD) has been installed on Experimental Advanced Superconducting Tokamak (EAST) to investigate the fast ion loss behavior in high performance plasma with neutral beam injection (NBI) and ion cyclotron resonance heating (ICRH). A two dimensional 40 mm × 40 mm scintillator-coated (ZnS:Ag) stainless plate is mounted in the front of the detector, capturing the escaping fast ions. Photons from the scintillator plate are imaged with a Phantom V2010 CCD camera. The lost fast ions can be measured with the pitch angle from 60° to 120° and the gyroradius from 10 mm to 180 mm. This paper will describe the details of FILD diagnostic on EAST and describe preliminary measurements during NBI and ICRH heating.


  • Measurement of the deuterium Balmer series line emission on EAST

    by C. R. Wu, J. Huang, W. Gao, Z. Xu, J. F. Chang, Y. M. Hou, Z. Jin, J. C. Xu, Y. M. Duan, P. F. Zhang, et al.

    Volume recombination plays an important role towards plasma detachment for magnetically confined fusion devices. High quantum number states of the Balmer series of deuterium are used to study recombination. On EAST (Experimental Advanced Superconducting Tokamak), two visible spectroscopic measurements are applied for the upper/lower divertor with 13 channels, respectively. Both systems are coupled with Princeton Instruments ProEM EMCCD 1024B camera: one is equipped on an Acton SP2750 spectrometer, which has a high spectral resolution ∼0.0049 nm with 2400 gr/mm grating to measure the Dα(Hα) spectral line and with 1200 gr/mm grating to measure deuterium molecular Fulcher band emissions and another is equipped on IsoPlane SCT320 using 600 gr/mm to measure high-n Balmer series emission lines, allowing us to study volume recombination on EAST and to obtain the related line averaged plasma parameters (Te, ne) during EAST detached phases. This paper will present the details of the measurements and the characteristics of deuterium Balmer series line emissions during density ramp-up L-mode USN plasma on EAST.


  • Open Access

    Validation of fast-ion D-alpha spectrum measurements during EAST neutral-beam heated plasmas

    by J. Huang, W. W. Heidbrink, M. G. von Hellermann, L. Stagner, C. R. Wu, Y. M. Hou, J. F. Chang, S. Y. Ding, Y. J. Chen, Y. B. Zhu, et al.

    To investigate the fast ion behavior, a fast ion D-alpha (FIDA) diagnostic system has been installed on EAST. Fast ion features can be inferred from the Doppler shifted spectrum of Balmer-alpha light from energetic hydrogenic atoms. This paper will focus on the validation of FIDA measurements performed using MHD-quiescent discharges in 2015 campaign. Two codes have been applied to calculate the Dα spectrum: one is a Monte Carlo code, Fortran 90 version FIDASIM, and the other is an analytical code, Simulation of Spectra (SOS). The predicted SOS fast-ion spectrum agrees well with the measurement; however, the level of fast-ion part from FIDASIM is lower. The discrepancy is possibly due to the difference between FIDASIM and SOS velocity distribution function. The details will be presented in the paper to primarily address comparisons of predicted and observed spectrum shapes/amplitudes.


  • Filterscope diagnostic system on the Experimental Advanced Superconducting Tokamak (EAST)

    by Z. Xu, Z. W. Wu, W. Gao, Y. J. Chen, C. R. Wu, L. Zhang, J. Huang, J. F. Chang, X. J. Yao, P. F. Zhang, et al.

    A filterscope diagnostic system has been mounted to observe the line emission and visible bremsstrahlung emission from plasma on the experimental advanced superconducting tokamak during the 2014 campaign. By this diagnostic system, multiple wavelengths including Dα (656.1 nm), Dγ (433.9 nm), He ii (468.5 nm), Li i (670.8 nm), Li ii (548.3 nm), C iii (465.0 nm), O ii (441.5 nm), Mo i (386.4 nm), W i (400.9 nm), and visible bremsstrahlung radiation (538.0 nm) are monitored with corresponding wavelength filters. All these multi-channel signals are digitized at up to 200 kHz simultaneously. This diagnostic plays a crucial role in studying edge localized modes and H-mode plasmas, due to the high temporal resolution and spatial resolution that have been designed into it.